Loading...
HomeMy WebLinkAboutProduct Approval MIAMI-EaADE MIAMI-DADE COUNTY Cramm PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 2088 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OAwww .minmfdade.gov/economy Sun-Tek Manufacturing,Inc. 10303 General Drive IL AV Orlando,Florida 32824 FILE COPY SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve"the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Sun-Tek Tubular kylight APPROVAL DOCUMENT: Drawing Ltio.22001,titled"21", 14"&10"Tube Light/Tubular Skylights", sheets 1 through 7 of 7,prepared by Sun-trek Manufacturing,Inc.,dated 10/14/2011,signed and sealed by James D.Wells,Jr.,P.E.,on 05/04/2015,bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shaft be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Bu ilding Official. This NOA revises NOA#11-0601.05 and consists of this page 1 and evidence submitted pages E-1 &E-2 as well as approval document mentioned above. The submitted documentation was reviewed by H my A.Makar,P.E.,M.S. NOA No 154513.06 MIAMMADECOUPITY Expiration Date: 05/26/2018 l J0 5 Zd S Approval Date: 11/05/2015 l I Page 1 San-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAI,#09-0422.01. A. DRAWINGS L Drawing No. TL 22001, titled "21", 14"&10" Tube Light/Tubular Skylights'; sheets 1 through 7 of 7,prepared by Sun-Tek Industries, Inc., dated 02112109, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. Test reports on 1)Air Inf�Itration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, loading per FBC TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Testper FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 24113.2.1, TAS 202-94 along with marked-up drawings and installation diagram of 21"Tube Aluminum Skylights,prepared by National Certified Testing Laboratories, Test Report No.210- 3520-01, dated 03104109, signed and sealed by Gerard J. Ferrara, P.E. C. CALCULATIONS 1. Anchor calculations prepared by J&L Wells Consulting, LLC, dated 04114109,signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE L Miami Dade Building Code Compliance Office MCCO) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 08-0305.02, issued to SABIC Innovative Plastics,for. their Lexan Sheet Products, approved on 04124108 and expiring on 07117113. 2. Notice of Acceptance No. OS-0907.03, issued to Palram Americas, Inc., for their Corrugated and Flat Polycarbonate Panels, approved on 08131106 and expiring on 0112212011. F. STATEMENTS 1. Code compliance statement issued by J&L Wells Consulting, LLC, dated 04114109, signed and sealed by James D. Wells, Jr., P.E. Hel A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No 15-0513.06 Expiration Date: 05126/2018 Approval Date: 11/05/2015 E-1 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.05 A. DRAWINGS 1. Drawing No. 22001, titled "21'; 14" &10" Tube Light/Tubular Skylights", sheets 1 through 7 of 7,prepared by Sun-Tek Manufacturing, Inc., dated 1011412011, signed and sealed by James D. Wells, Jr.,P_R, on.10/14/2011: B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. 3. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 22001, titled. "21", 14" &10"Tube Light/Tubular Skylights", sheets 1 through 7 of 7,prepared by Sun-Tek Manufacturing, Inc., dated 1011412011, signed and sealed by James D. Wells, Jr., P.E., on 0510412015. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. FBC,2014 Edition Code compliance statement issued by J&L Wells Consulting, LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E. H&My A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No 15-0513.06 Expiration Date: 05126/2018 Approval Date: 11/05/2015 E-2 PART NAME: EXTERIOR DOME METRO DADE PLAN VIEW ISHEET 1 OF 25.625 DRAWN BY: -L. B. REED 0 a a N ,080 PLOYCARBO N UJ O ' 21 " SUN—TEK TUBLAR SKYLIGHT N (12) — X10 X 2 PAN HEAD SCREW LO (12) — 1/8 X 3/16 — 1/4" GRIP LO N ALL ALUMINUM LARGE FLANGE RIVET Engineer ofRww ; IN 00 James D.Wells,Jr.,1.E. 00 Professional Engineer No.5361( 0 AL WELLS CONSULTING LLC. 1453 Arblum Circle Oviedo, PL 32763 (407)496-5489 -.-__--- — ---- _ CerdQew of Audiwizadon No:27162 o CURB TO DECK MOUNTING REQUIREMENTS inrr. 7RTNAIME: EXTERIOR DOME METRO DADE PLAN VIEW ISHEET 2 OF DRAWN BY: L. B. REED 18.625 o ' 0 a �i .080 POL' N Trj LO 14" SUN—TEK TLIBLAR SKYLIGHT N (12) — #10 X 2 PAN HEAD SCREW 00 (12) — 1/8" X 3/16 — 1/4" GRIP ALL ALUMINUM LARGE FLANGE RIVET Engiaeer of Record; James A Weng,Jr.,EE. LO Professional Engineer No, N T MA 4_ J&L WELLS CONSULTIN4 1453 Arbitas Circle Oviedo, PL 32765 (407)496-5499 Cwdfioste of Awilso&a tpa No.i o CURB TO DECK MOUNTING REQUIREMENTS o NOTE: _ N SHLN ALL ROOFING DH CHAPTER 15, 2014 EDITION 114ETAILS " (3)2PER 2SIDE 12 TOTALS ALLCOMP YWITH 171 ^m[t A 1711 111 nlAln r%nnr_ - - -- - -- -- --- PART NAME; EXTERIOR DOME METRO DADE PLAN VIE SHEET 3 OF DRAWN BY: L. B. REED 14,625 0 0 N .080 F N_ M N 10" SUN-TEK TUBLAR SKYLIGHT N (12) - #10 X 2 PAN HEAD SCREW (12) - 1/8" X 3/16 " - 1/4" GRIP ALL ALUMINUM LARGE FLANGE RIVET N Engineer of Recon M James A Wells,Jr Professional Bn& JBtL WBi,LS 0 1453 AMU= N Oviedo, PL 3 NOTE:- CURB TO DECK MOUNTING REQUIREMENTS (407)496"541 (1) ALL ROOFING DETAILS #-10 X 2-1/2" DECK SCREWS C09ft0e of A SHALL COMPLY WITH CHAPTER 15, 2014 EDITION 10" (3) PER SIDE 12 TOTAL OF THE FLORIDA BUILDING CODE POSITIVE DESIGN LOAD 65 PSF (2) 4" MINIMUM DISTANCE FROM ANGLE LIP NEGATIVE DESIGN LOAD 65 PSF rn DnnC Cl IDCArC IC Crll? C4.III%lrNI C AP RI 111 T - I IP POOP tinkrcn Yrc-r noroci nor i r, ocr PART NAME: DECO RING ISHEET 7 IDRAWN BY: S RYAN 0.060 REF, (6X) (D .080 POLYCARBONATE DOME .031 R, X .031 HIGH 0.500 .030 POLYCARBONATE INNER REF. ALUMINUM LIGHTING SHEET STI-275 DECO RING RTV SILICONE SEALANT FLAT HORIZONTAL RETAINER .020 GALV. SUN-TEK ST 1000 SEALANT #lOX2 PHS #lOX 2-1/2 DECK SCREW ROOFING FELT FLASHING BY OTHERS 0 0 LL_ IN ACCORDANCE WITH NBCA Lr) Ld 2X6 CURB MINMIUM O] 4" HEIGHT ";t C?I CL 4 Lo ,MIN. i.11 EMBEDMENT + Af 4" MINIMUM 0 C; SHINGLES (I HEIGHT (2) Lo Lo L_ r- REF. ROOF DECK MIN. 5/8 EMBEDMENT ILA (2x) 5/8 MINMtuN 0, SUN-TEX ST 1000 SEALANT PART NAME; CM DOME SHEET 5 OF 7 DRAWN BY: S RYAN .080 POLYCARBONATE DOME .080 POLYCARBONATE nf orn w �s 0 0 1 .875 1 .875 -� - 21 .00 �— 25.25 i 0 torn 21 " TUBULAR SKYLIGHT DOME 10 " T .080 POLYCARBONATE DOME cnw .o N W 0 o 1 .875 DOM z—� .PALRAI PART INSTALLATION DESCRIPTION SHEET 6 OF 7 I DRAWN BY: L. Q. REED (D.080 POLYCARBONATE DOME C, @-030 POLYCARBONATE INNER QDOME FASTENERS ITEM PART NAME DISCRIPTION -- VENDOR - 1 EXTERIOR DOME .080 POLYCARBONATE DOME SEE DOME MATERIAL_ 2 SEALING TAPE DUCT TAPE 2" VENTURE TAPE 3 ELBOWS MIRO 4 ALANOD 4 CONNECTOR MIRO 4 ALANOD 5 LENS RING ASSEMBLY INTERIOR DOME 6 #10 PHS X 2" FASTENERS EXTERIOR DOME MERIT FASTENER 7 * -L6 X1,Z2"HEX TEK TUBE FASTENERS MERIT FASTENER . 8 #10 X2-1/2" DECK SCREWS CURB ANCHORS MERIT FASTENER 9 1/8 X3/16" GRIP ALUM. DECO RING FASTENER Mc MASTER-CARR LARGE FLANGE RIVET 10 .020 GALV. TUBE RETAINER . 11 DECO RING EXTRUSION 112 INNER PANEL 1 .030 POLYCARBONATE INNER ----- THIS APPROVAL IS LIMITED TO THE DOME AND THE ATTACHMENT TO THE JOINT SEALING TAPE STRUCTURE AND THE ROOF. ALL OTHERS ARE NOT PART OF THIS APPROVAL. HIGH- REFLECTIVE ALUMINUM ELBOW DOME SPECIFICATIONS LENS RING ASSEMBLY 91 " DOMF HEIGHT 9" PART NAME: TUBE RETAINERS ISHEET 7 OF 7 DR N BY: L. B. REED it 24.500 0 0 LO 0 o - Lq 't X21 2�0 clq 13.500- 21 " TUBULAR it SKYLIGHT 0 10" TUBUL/ L SKYLIGHT of 0.2 �7iarzo�s Florida Building Code Online tr i-. i aN rt. 4^0 BCIS Home I La In User Re - - •r ' �j�,d'��q;��r';,�1�• g glstratlon j HotTopl6 � Submit Surcharge i Stats Facts Publications FOC Staff i BC1S Site Map '• Links i Search ! Busines F Product Approval Professital USER:Public User Product Approval Menu>Product or Aoolicatlon Search>Application List>Application Detail . FL# FL7006-119 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer IKO Industrles, Ltd Address/Phone/Email 40 Hansen Road South Brampton,NON-US L6W 3H4 (708)496-2800 Ext 200 rmetz001@tam pabay.rr.com Authorized Signature Robert Metz rmetzOOI@tampabay.rr.com Technical Representative Bob Metz Address/Phone/Email REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727.) 776-5261 rmetz0010tam pa bay,m com Quality Assurance Representative Don Shaw Address/Phone/Email IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579-6706 don.shaw(c@iko.com Category Roofing ' Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency FM Approvals-CER Validated By Locke Bowden Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 modified to 110 mph. 2009 ASTM D3462 2009 ASTM D7158 Class H 2008 ASTM E108 2007 Equivalence of Product Standards Certified By MtpsJ/www.floridabwiding.org(pr/pr app dfl aspx7param=wGEVXQwtDgse7mYBd2b3KBmXtoZLhNVX122Np17DJ1EMail 1/3 7/812016 Florida Building Code Online Product Approval Method Method I Option A Date Submitted 06/28/2015 Date validated 06/30/2015 Date Pending FBC Approval Date Approved 07/06/2015 Summary of Products Ft.# Model,Number or Name Description 7006.1 Cambridge, Cambridge HD and CRC Laminated architectural Fiberglass asphalt shingle Biltmore AR manufactured at IKOs Kankakee,IL; Hawkesbury,Ont.; Wilmington,DE, Sylacauga,AL and Toronto,Ont. plants Limits of Use Certificatlon Agency Certificate Approved for use in HVHZ.,Yes E700 as C..CAC FM Letter-ASTM d3161 letter- 4-15- Approved for use outside HVHZ:Yes 2915f Impact Resistant:N/A &70Q6 R9 C CAC FM Letter-ASTM d3462 letter-5 6 Design Pressure:N/A 15,odf Other: ELZO06 R9 C CAC FM Letter-ASTM E 108 letter- 5 3 15 nd Quality Assurance Contract Expiration Date 12/3112020 Installation Instructions FL7006 R9 11 IKO-133-02-01-Letter-Installation Instructions for FBC FL7006.pdf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.2 kip and Ridge 12 Cap fiberglass This is a 12'x 12"fiberglass asphalt shingle used to cover shingles the hip and/or ridge of an asphalt shingle roof system I manufactured in Toronto,Ont.and Brampton, Ontario Umits of Use Certification Agency Certificate Approved for use In HVHZ:Yes FL7006 R9 C,CAC FM Letter-ASTM d3161 leder-. 4-15- Approved for use outside HVHZ:Yes 2015 2df Impact Resistant:N/A FL7006 R9 C CAC FM Letter-A5-TM d3462 letter-5 Design Pressure:N/A 15� other: F7 7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3 15 P4 Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL7006 T9 11 Hip and Ridge Can.Shingle Installation Instructions.pd FL7006 R9 11 IKO-133-Q2-01 Letter-Installation Instructions for FBC FL7006.od Verified By: Duc T Nguyen PE 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 7006.3 Leading Edge Plus Asphalt Shingle One piece Fiberglass asphalt shingle used as a starter strip at Starter Strip the bottom of a roof system manufactured in Brampton and Hawkesbury,Ontario plants Limas of Use Certification Agency Certificate Approved for use In HVHZ:Yes FI 006 119 C -CAC EM Letter-ASTM d3161 letter- 4-15- Approved for use outside HVHZ:Yes 2015 nd Impact Resistant:N/A Ft R9 C CAC FM Letter-ASTM d3462 letter- 5 Design Pressure.N/A 1 Other. FI R9, C CAC FM Letter-ASTM E 108 letter- S 3 15 pd Quality Assurance Contract Expiration Date IZ/31/2020 Installation Instructions FI R9 TI IKO-133-02-01 Letter- installation Instructions for FBC FL7006.2d E17006 R9 11 Roofing-Products-Leadina-Fdop,-PIU5= Application-EN.f 1).vdf Verified By: Duc T Nguyen Pr=65034 Created by Independent Third Party; No Evaluation Reports Created by Independent Third Party; �70015.4 Marathon 25 AR,CRC Superglass 3 tab fiberglass asphalt shingle manufactured at IK httpsIMrww.floridabLdidirxg.org/priprapp_�N.aspx?param=wGEVXQwtDqse7mYBd2b3K6mXtoZLhNV)022Npi7UJlED/.3d 213 7/8/2016 Florida Building Code Online M25AR Brampton,Ontario, Hawkesbury Ont.,Toronto,Ont.; Sylacauga,AL and Kanakakee,IL plants Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15- Approved for use outside HVHZ:Yes 2015 .Ddf Impact Resistant: N/A EL7006 R9CCAC FM Letter-ASTM d3462 letter-5 6 Design Pressure:N/A IS.odf other: FL7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3 15 pdf Quality Assurance Contract Expiration Date 12/20/2020 Installation Instructions FL7006 R9 II IKO-133-02-01 Letter-Installation Instructions for FBC FL7006.ndf Verified By: Duc T Nguyen 65034 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: ' Bach Ne�:t Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/g0 employer.copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees Iloensed under chapter 455,F.S.must provide the Department with an small address If they fiave one:The smalls provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dldc bjM_. Product Approval Accepts: Credit•Card' . Safe httpsl/www.gridaWIcing.orgtpr/pr app fl.aspx'tparam=wGEVXQwtDgse7mYBd2b3K6mXtaZLhNVX[22Npl7GJlEa/o3d 3!3 < FM Aipprovals- FM Approvals Membfr of ito r.:v c:om l Grvu; 1151 Boston-Providence Turnpike P.O.Box 9102 Norwood,MA 02062 USA T:781762 4300 F:781 762 9375 www.fmapprovals.com May 3,2015 Mr.Donald Shaw IKO Industries,Ltd. 40 Hansen Road South Brampton,Ontario L6W 3H4 Canada Customer ID: 1000000686 Subject: IKO Industries Ltd.'s FM Approved asphalt roof shingles Dear Mr. Shaw, This letter is being written following in regards to your recent inquire regarding verification of the ASTM D3161 testing of IKO Industries Ltd's asphalt roof shingles. TKO's shingles that are FM Approved have been tested in accordance with ASTM D3161(reports 3040947 and 3038510). FMA roved roducts: I :itiulustes°Ltd::'.;; Crowne Slate,Cambridge;Hip&Ridge 12,Marathon 25 AR,Marathon Ultra AR,Cambridge At,Leading Edge Plus,Cambridge HD,Marathon . 25,Hi &Rid a Plus, as with AnnourZone o£;Col bradw. Biltmore,Hip&Ridge 12(CRC),Superglass 25 M AR,Superglass Ultra AR, CRC Hip&Ridge Plus Please be advised that shingles noted above tested to previous versions of ASTM D3161 continue to meet the test criteria of the current version of ASTM D3161. If you have any questions please do not hesitate to contact me. Very truly yours, David L.Alves Phillip J. Smith Senior Engineer-Materials Group Principal Engineer-AVP FM Approvals FM Approvals 1151 Boston-Providence Turnpike Norwood,MA 02062 T:781 255 4856 E:david.alves@fmapprovals:com €X FM FM US �aPllov® a�rawl� CONSTRUCTION MATERIALS TECHNOLOGIES March 30, 2015 IKO Industries, Ltd 120 Hay Rd. Wilmington, DE 19809 Re: FBC FL7006 Sir(s), .PRI Construction Materials Technologies has completed a technical review and attached sealed shingle instructions in compliance the 2014 Florida Building Code. This review was completed based on the receipt of following evidence from IKO Industries, Ltd: 1) 'IKO Shingle Application Instructions—3-Tab Shingles (EN-3Tab_Appins_BAGXEFS-2012-11 reformatted 2013-02-rev07/13-Florida) 2) IKO Laminated Shingles Application Instructions (EN-Laminated,,Appins_8TTEFS-2012-04—reformatted 2013-02-rev07/13-Florida) 3) IKO Hip and Ridge 12 Application Instructions (EN-HipandRidgel2 3HRTri-2013-08 reformatted 2013-08) 4) IKO Leading Edge Plus Shingle Application Instructions (EN-3LEP-Tri-2012-06_reformatted 2013-03) 5) ASTM D3161 Test Report(FM Approvals Project No.3040947) The attached instructions should be used in conjunction with the published manufacturer's application instructions and applicable code. In the event the instructions conflict, these instructions shall govern. Statement of Independence:PRI Construction Materials Technologies and/or Duc T.Nguyen,FL P.E.do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. Al- Signed: , �, Signed: �. c Brad Grzybo ski Due T.N Managing D rector Florida Re re Professional Engineer P.E.Number:65034 Date: April 30, 2015 Date: April 30;2015 Attachments: A) IKO Shingle Application Instructions-3-Tab B) IKO Laminated Shingles Application Instructions C) IKO Hip and Ridge 12 Application Instructions D) IKO Leading Edge Plus Application Instructions IKO-133-02-01 PRI Conshxldon Materials Technatogies,LLC.8412 Badger Drive Tampa,FL 33010 Tel:813.8215777 Fax:813.621-5840 e-mail:materialstesting@pdcmt.rnm WehSite:htlpJhwvw.pricmLcam IKO Installation Instructions for Asphalt Shingles Page 2 of 5 IKO Shingle Application Instructions — 3-Tab Shingles (ASTM D3161, Class F—IKO Marathon 25 AR and CRC Superglass M25AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC. UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code requirements, the first sheet overlapping the save protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved underlayments in accordance with the qualified application instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of underlayment laid parallel to the eaves,-with 2"horizontal laps and 4"and laps_ Apply metal drip edges on top of any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt edge,approx. l"and 13"from each end and 112"above each cutout. Drive nails straight so that nail head is 'flush with, but not cutting into shingle surface. . NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight.'" EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8". STEEP SLOPES. 1.172" t-irr SEALING STRIP �.... ` .— a NAILS NAILS DO NOT NAIL ltIT0 OR ABOVE THE•SEALING STRIP PRI Construction Wedels Technologies,I.I.C.8412 Badger Drive Tampa,FL 33610 Tel:813821-5777 Fax:813.8215840 e-maB:matedalstesdng@pdcml.com WebSite:httP:l/wrvw.Pdcmtcom IKO Installation Instructions for Asphalt Shingles Page 3 of 5 IKO Laminated Shingles Application Instructions (ASTM D3161, Class F—Cambridge,Cambridge HD, and CRC Biltmore AR) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC. UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is less than 4" per foot down to 2" per foot, use 2 layers of undedayment conforming to building code requirements, the first sheet overlapping the-eave protection by 19",followed by full 36"widths overlapping each preceding course by 19"or other Approved undedayments in accordance with the qualified application instructions. For areas where the roof slope is 4° per foot or greater, cover the deck with one ply of undedayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top of.any underlay along rake edges and directly to the deck along eaves in accordance with building code requirements. NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long ' enough to penetrate through plywood or 3/4"into boards. Use 4 nails'per shingle placed in the nail line 7-3/8" below the top edge, approx. 1"and 13"in from each end. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(600)or more,use 6 nails per shingle placed as shown below. Ensure that no nail-is within 2"of a joint/cutout of the underlying shingle. Seal down each shingle at time of application with three 1"diameter(approx,size and thickness of a quarter)spots of asphalt plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle. Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the heat of direct sunlight. EXPOSURE: Installed shingles shall have a maximum average exposure of 5-7/8". NAILING-;STEEP SLOPES APPEECATION t se�six nails as shown. NAIL LINE .NAILS CEMENT PROPERAPPLICATION REQUIRES WAT THE NAILS PENTRATE BOTH T4JE OVERLAY ANP ONDgRLAY PORTIONS OFTHE SH.INGLI= PRI Construction Materials Technol4les,U.C.6412 Badger Drive Tampa,FL 33610 Tel:813-621-5777 Fax:813.621-"840 a-mail:materialstasting@pricmt.com Website,httpJMnvw.pdcxatcwm IKO Installation Instructions for Asphalt Shingles Page 4 of 5 IKO Hip and Ridge 12 Application Instructions (ASTM D3161, Class F--IKO Hip and Ridge 12) NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are designed for a 51/8"(130 mm)exposure.(For a neater appearance,the top of each side of each piece has been factorytrimmed on a 1"(25 mm)taper(see drawing).Bend each piece overthe hip or ridge,and nail 5 5/8" (143 mm)above the butt edge 1" (25 mm) in from each edge, exposing each piece 5 1/8" (130 mm). Apply hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieces starting at the end opposite to the prevailing wind direction and continue to the other end. Note:To obtain a three-dimensional effect,(which is recommended,but not required),apply hip and ridge shingles double thickness bystacking 2 .pieces on top of one another,the lower piece extending about 3/4"(19 mm)further than the top piece(see diagram).The final shingle should be set in cement,and the exposed nail heads of the final shingle should be covered with cement.Prior to application in cold weather,storing the shingles in a heated area will allow for easier bending. NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEYARE DESIGNED FOR USEAS HIP AND RIDGE SHINGLES ONLY,AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS.WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS.-REVIEW ALL APPLICABLE BUILDING CODES,-MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. 374• f fo mm) ' (e9 mn; TOM our 9110• � 1130 mnl) �� 6 am na.mm1 PRI Consh icWn Materials Tachrwlogles,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813.821.5777 Fax:813-821.5840 e-mail:matmielstesting@prlcmt.com WebSite:http:f/www.pricmt.cam IKO Installation Instructions for Asphalt Shingles Page 5 of 5 IKO Leading Edge Plus Application Instructions (ASTM D3161, Class F—IKO Leading Edge Plus) NOTE: THESE INSTRUCTIONS SHALL 'BE USED IN. CONJUCTION WITH IKO'S PUBLISHED APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION CONFLICT,THESE INSTRUCTIONS WILL GOVERN. 1. Apply any underlayment,eave protection,valley flashings, or drip edges to roof deck as required. 2. Each 39 3/8"x 131/4"(1000 mm x 336 mm)IKO Leading Edge Plus strip is perforated lengthwise for separation into two(2)shingles.Take one IKO Leading Edge Plus strip and fold flat at perforation to separate. 3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 mm x 168 mm)and remove approximately 20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up,with the factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with nails located 3"to 4"(75 mrh to 100 mm)from the eave edge and•1"(25 mm)in from each end. 4. Take the leftover 20"(500 mm)piece shingle.Rotate the piece and align it vertically up the rake edge with the factory installed sealant adjacent to the outer edge of the roof.The shingle should overhang the rake edge by a nominal 1/4"(6 mm)minimum.Fasten the shingle to the roof deck with fasteners located 3"to 4"(75 mm to 100 mm)from the rake edge and 1"(25 mm) In from each end. 5. Repeat Steps 3—4 for the right lower comer of the roof deck. NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"(9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20 mm)into boards. Use 4 nails per shingle placed 3"to 4"(75 mm to 100 mm)from the eave edge and approximately 1"and 13"(25 mm and 330 mm)in from each and. 6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum.Fasten the shingles to the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge,4 nails per shingle. 7. Apply roof shingles as per the instructions printed on each product's package. Make certain the first course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way, the sealant on the IKO Leading Edge Plus shingles will adhere to the first-courte field shingles and help keep them from lifting in high winds. PRI ConstrucUun Materials Technol4es,LLC, 6412 Badger Drive Tempa,FL 33810 Tel:813.621STTT Fax:813.8215840 a-ms9:materlalstestlng@prlcmtcom WebSite:http:lhvwm.priantcom Florida Building Code Online http://www.floridabuilding.org/pr/pl�-appiti-aspx'lparam=;'Al(iEVX..- 0. INN 4R.-, BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts PublIcatlons FSC Staff SCIS Site Ma Bus*ines5 PrbdUA Pro s s i 6"n."a USER:PetublicpprovalUser >EMdkKtRLAaWt41gn5earth>A pi)ratlist>App 1:1 n DOW FL# FL2569-R11 ........ ........ .... ...... Application Type Revision Code Version 2014 Application Status Approyed Comments Archived Product Manufacturer Soprema,Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memathieu@s.oprema.cb Authorized Signature Marc-Etienne Mathieu memathieu@sqprema.ca Technical Representative Marc-Etienne Mathieu Address/phone/Email 1688 Jean-Berchmans-Michaud Drummondviller NON-US 00000 (819)478-2400 Ext 3327 memathieu@spprem.a.ca Quality Assurance Representative. Jean-Francois Cate, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect o Florida Professional Engineer. Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W. Knezevich, K of 3 1/5/2016 3:08 PM Florida Building Code Online http://www-floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX... *� Validation Checklist-Hardcopy Received Certificate of Independence FL2 1211 CE�1 zQ?5 Oi CCTi Nieminxa,gdf Referenced Standard and Year(of Standard) Standard ASTM D1970 ASTM D6163 ASTM D6164 FM 4474 FRSA/TRI April 2012 (04-12) TAS 103 TAS 110 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/21/2015 Date Approved 12/15/2015 Summary of Products FL# Model,Number or Description Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ:No FL2569 R11 II 2015 10 FINAL F4 SOPREMA CA UNDEIRLAYP Approved for use outside R11.pd HVHZ:YesVerified By: Robert Niemineri, P.E. PE-59166 Impact Resistant:N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-90 Evaluation Reports Other: 1.)Refer to ER Section 5 for EL2569 R11 AE 2)15 10 FINAL. ER SOPREMA CA UNQQ1L_AY Limits of Use.2.)The design pressure Rll.pd noted herein pertains to underiayment Created by Independent Third Party: Yes systems•used beneath adhesive-set tile- systems.Refer to ER Section 5.6.4 for details. • :Bade �Next� .. Contact Us,:1946, North Monroe Stme Tallahassee FL 32199 PhUne'850-487-1824 The State of Florida is an AA/EEO employer.C„,^.vrlahr. 2n07 ofa Stat 'ot Florida.::FrhMQLStatement:;Accessi 9b statement;:a Under Florida law,email addresses are pubiic records.If you do not want your e-malladdress released In response to a pubec-records req of 3 1%5/2016 3:08 PMI Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl,aspx?paratn=wGEVX..: electronic man to this entity.Instead,contact the offlce by phone or by traditional mall.If you have any quesmns,pLase contact 850.487. Section 455.275(1),Florida Statutes,effecthre October 1,2012,5cengees licensed under Chapter455,F.S.must proVide the Department wl they have one.The emalfs provided may be used for official communication vilth the licensee.However email addresses are public record,D supply a personal address,please provide the Department with an emall address which can be made available to the public,lb determine if yo Chapter 455,F.S.,please click here. Product Approval Accepts.- Off" ccepts:x scc.RtriYc� ;•� . •r of 1/5/201.6 3:08 PM EXTERIOR RESEARCH&DESIGN,LLC. . ` _ Certificate of Atitlhorization 1419503 UNIT#13 i �� 353 CHRISTIAN ERD OX OXFORD, 06478 PHONE:(203j 262-9245 FAX:(203)262-9243 LUATI EEVAON REPORT Inc. Evaluation Report S18010.06.09-R9 VLUATI 1640 rue Haggerty' FL2569-R13 Drummondville,Qu6bec J2C 5P8 Date of Issuance:06/15/2009 Canada Revision 9:10/12/2015 SCOPE! This Evaluation Report.is issued under Rule 61G20-3 and the applicable rules and regulations governing the.use of construction materials inthe State of.Florida,The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. If the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in"its entirety, INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its-distributors and shall be available for inspection at the job site.at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: 1 tits:nreay,� Ftn 1%,ON �1'A��. Thefautmile.sealappearMgwasauthorized byRobert Nleminen, Robert J.M.Nieminen,P.E. fi"'�Fr' e,�.,� P.F,�1n/12/MT This does not serve as an elaetionioallvsi9ned Florida Registration No.59166,Florida DCA ANE1983 i,h qlO+l Ati- tfi`: document.S(gned,sealed hordcoplas have baen transmitted tothe ProduetApproval Admintsteatorand tothanamadrJlam tom'' CEimFICATIONOFINDEPENDENCE: 1. Trinityl ER0 does not have, not does it intend to acquire.or will it acquite, a financial interest In any company Manufacturing or distributing products it evaluates. •2. Trinityl ERD Is not owned,operated or controlled by any company manufacturing or distributing products>t evaluates. 3. Robert Nleminen,P.E,does not have nor will acquire,a financial interest in any company manufacturing or distributing products'for which the.evaluatlon reports are being issued. 4. Robert Nleminen,P.E.does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the product. 5. This Is a building code evaluation. Neither Trinityl ERD nor Rpbert Nieminen, P.E.are,in any way,the.Designer of Record for any project on which this Evaluation Report,-or previous versions thereof,is/was used for permitting or degign guidance unless retained specifically for that purpose. P TKIN I -v r ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category. Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the follomilng sections of the Florida Building Code through testing in accordance with the following"Standards. Compliance is-subject to the installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS: Section Property Standard Year 1504.3,1 Wind Resistance FM 4474 2004 1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009 1507.2.9.2,1507.4.5.1, 1507.5.3,1507.7-3 1507.11.2 Physical Properties ASTM D6163 2006 1507.11.2 Physical Properties ASTM D6164 2005, 15216.*5.2.1 Physical Properties TAS 103 1995 TAS'110 Accelerated Weathering TAS 110 2000 1$07.3,.3 Installation Practice FRSAITRI April 2012(04-12) 2012 3. REFERENCES: faft Examination Reference Date ERD(T MO49) ASTM D1970/TAS 110 2968.05.04-2 015/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05;.2 05/17/2005 ERD(T5176049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007 ERD(TST6049) TAS 103/TAS IIG 57120AA.07-2 11/02/2007 ERD(TM049) ASTM D1970/TAS 110 S13190-02.09-RI 04/01/2020 ERD(TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-RI 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/0512010 ERD(TST6049) ASTM 131970 537210.11.11 11/09/2011 ERD(M6049) ASTM D1970 540540.02.13-1 02,/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/1312015 ERD(TST6049) Accelerated Weathering 5OPC-SC8520.14 04/17/20-15 M-D(CER1592)' HVHZ Compliance 09-1005.02 11/04/2010 M-D(CER1592) HVHZ Compliance 13-0530.02 11/2712014 ICC-ES(EVL2396) 2012,2009 and 2006 113C Compliance ESR-1524 10/01/2914 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/203.3 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015 UL,LLC(QUA9625) Quality Control ServlceConflrmation Exp.10/i.6/203.7 4. PROD=DEscRipTiow 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SSS mocitfied bitumen roof underlayment 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen 'roof Onderlayment available in two widths;36 and 45 Inch. 4.3 RIESISTO SA SMOOTH PLY 40 Is a self-adhering, woven polyethylene surfaced,SBS modified bitumen roof underlayment;available in 3.3,ft x 65 ft rolls. Exterior Research and Design,ELC. Evaluation Report 518010.06.09-R9 Certificate of.Aaftarizatidn#9503 J112569-R11 Revision 9:10/12/2015 Page 2 of 7 i TRINITY'ERD 4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4:5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.7 Lastobond. 195 is a self-adhering, glass-mat reinforced,, sand-surfaced, SBS modified bitumen roof underlayment. 4.8 Lastobond is a self-adhering; glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment. 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment. 4.10 Lastobond Smooth Seal HT'is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment. 4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SSS modified .bitumen roof underlayment,with a 36-inch sheet width. .4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self;.adhering,glass-mat reinforced,sand-surfaced,SBS- modified BSmodified bitumen roof underlayment,with a 36-inch sheet width. 4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, 513S modified bitumen roof underlayment,with a 44-inch sheet width. . 4.14 Colphene FR GR is a seif-adhering, fiberglass reinforced, granule surfaced, SBS modified bitumen roof underlayment. 4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof underlayment. 5: UMITATIONS: 5.1 This is a building code evaluation. Neither Trinityl.ERD nor RAbert Nieminen, P.E. are, in any way, the Designer of Record for any project•on which this Evaluation Report, or,previous-versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this.report; refer to current Approved Roofing Materials Directory for fire ratings-of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering: 5.5 Allowable roof covers applied atop the underlayments are follows: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Nail-Ori Foam-On Metal Wood Shakes& slate Shingles Tile Tile Shingles Lastobond TU HT Yes Yes Yes . Yes Yes Yes See 5.5:1 Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes RESISTO SA SMOOTH PLY 40 Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes Lastobond/Lastobond 195 Yes No No No Yes Yes Exterior Research and Design,LLC. Evaluation Report$18010.06.09-R9 .15ertfflcate0JAathdr1:0don M03 FL2569-R1i ... Revislon 9:10/12/2015 Page 3 of 7 `'E RED TABLE 1: ROOF COVER OPTIONS Asphalt Nail-On Foam-On Wood Shakes& underlayment Shingles Tile Tile Metal Shingles Slate Lastobond ECO /RESiSTO 1_61236,Grip-Rite Eave&Valley Yes. No No No Yes Yes Protector/RESISTO L81244 Lastobond Smooth Seal HT Yes No No Yes Yes Yes Yes Colphene FR GR Yes Yes See 55.1 No. Yes Yes Unilay(e) Yes Yes Yes Na No No Batten Only See 5.5.1 5.5.1 "Foam-On Tile" is limited to.use of the following adhesives unless tensile adhesion/long term aging data from an accredited testing laboratory is provided. Underlayment Adhesive(s) Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical Tile6ondT""Roof Tile Adhesive(FL717) Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: . Lastoband Shield, Lastoband Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond, Lastobond 195,.Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector,RESISTO L81244 or Lastobond Smooth Seal HT applied to: D Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. D Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond to-Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond,. Lastobond 195, Lastobond ECO, RESISTO LB1236, Grlp-Rite Eave & Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied-to.: > Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems-(Lastobond TU HT only),insulation attachment shall be designed by.a qualified design professional and installed based on testing of the insulatlon/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. Exterior Research and Design,LLC Evaluation Report 51$010.06.09-119 Cardficatc ofAuthorh ertka 119503 FL2569-R11 Revision 9':10/12/2015 Page 4 of 7 ' � 5.6.3 Bond to Mechanlcallv Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro' HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector,RESISTO LB124.4,Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM 0226,Type I or 11 felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof-coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TR.I April 2012(04-12). .5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Aprrlications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems;where the underiayment forms part of the load-path. The following wind uplift limitations apply to underiayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable,wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6:4:1 Maximum Design Pressure=-45.0 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)Elastocol Stick or Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.2 Maximum Desien Pressure=-67.5 ri Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: Elastocol600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-Inch o.c.at the 4-inch laps and.6-inch o.c.in three,equally spaced rows in the center of the sheet. Underlaymerit: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.4 Maximum Design Pressure=-90:0 psf Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Underlayment: Unilay(e) mechanically attached with 5oprafix Polymer Batten Bar (PB6) or Soprafix Metal Batten Bar(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c.within the 5- inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air welding techniques. 5.7 Exposure Limitations: Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave & i Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HTS shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer-than 180-days.after installation. Exterior Research and Design,LLC. Evaluation Report S18010,06.09-R9 CertWeate afAuthorkatioa#9503 F1.2569-1111 Revision 9.i0/12/201s. Page of 7 R1N1TY_ :ERS: 6. INSTALLATION: '6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject#o the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or Elastoco1'600c(if applicable). 6.3 Lastobond TU HT Lastobond Shield Lastobond Pro HT-N,RESiSTO SA SMOOTH PLY 40,_Lastobatid Shield HT; Lastoband Pro HT-S,Lastobond Lastobond 195 Lastobond Eco Lastobond Smooth Seal HT.RESISTO L81236 Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR: 6.3.1 Shall be installed In compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applicatl6ns: While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 6000 if the-final roof cover is not slated for'Installation within.24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release.film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight.•Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- Inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12,Soprema recommends back-nailing in the overlap area-at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction: For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR onlvl: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table I-herein, using the instructions'noted above as a guideline. For foam-on tile applications, reference is-made to Section•5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tiie slippage and/or damage to the underlayment. Unila e : 6.4.1 Non-Tile Applications or Nail-On Battened Tile Applications: Reference is made to Table 1 herein and FRSA%TRI April 2012(04-12)Installation Manual(if applicable). Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope, mechanically attach the S-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap- nails spaced 36-inch o-c. Apply the second course in a water-shedding manner with self-adhering side- laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All overgranule end-laps shall be sealed using either heat-welding or hot air.welding techniques. Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-119 .CerdficM ofAurh"katlon#9503 F.L2569-01 Revision 9:10/22/20155 Page 6 of 7 T -TY!ESRDRINI Tile(if applicable)shall be loaded and staged in a manner that prevents tile slippage and/or damage to the. underlayment'. 6.4.1 Loam-On Tile Applications: Reference is made to FRSA/TRI April 2012(04-12) Installation Manual, Table I herein and Section 5.6.4.4 herein. Apply sheet parallel to the roof edge and, starting- at the eave with the selvedge-edge upslope, mechanically.attach the 5-inch wide selvedge-edge-to the wood deck Soprafix Polymer lymer Batten Bar(PBB)or Sopraflx Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-Inch o.c. Apply the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2:-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either-heat-welding or hot air welding techniques. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the undedayment. 7. BUI WING PERMIT REQUIREMENTS: As required by the Building official or Authority Having Jurisdiction in order to properly evaluate the installation of this.product. MAWFAcruaws PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under,Rule 61G20-3 QA requirements. 9. QUALITY-AssuRANCE ENTITY: UL,LLC,—QUA9625;(314)578-3406;k.chancellor@us.ul.com END OF EVALUATION REPORT- WOW Research and Design,I.I.C. Evaluatlon.Report$19010.06.09-Re CertdkWepfAuthvr1xoU*n.#9503 FLU69-R11 Revision 9:10/12/2015 Page Tof 7 SCIS Home i Log In 1 User Registration Hot Topics Submit Surcharge j Stats&Facts Publications i FBC Staff 3 BCIS Site Map' Links i Search arida Product Approval .USER:Public User . y Product Approval Menu>Product or Application Search>Application List>Application Detail { FL# FL2847-R8 Application Type Revision Code Version 2014 Application Status Applied For Comments Archived 171 Product Manufacturer Lomanco,Inc Address/Phone/Email 2101 West Main Street Jacksonville,AR 72076 (501)982-6511 acarter@lomanco.com Authorized Signature Andrew Carter acarter@lomanco.com Technical Representative Andrew Carter Address/Phone/Email 2101 West Main Street Jacksonville,AR 72076 (501)982-6511 Ext 361 acarter@lomanco.com Quality Assurance Representative Andrew Carter Address/Phone/Email 2101 West Main Street Jacksonville,AR 72078 (501)982-6511 Ext 361 acarter@lomanco.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Miami-Dade BCCO-EVL Quality Assurance Entity Miami-Dade BCCO-QUA Quality Assurance Contract Expiration Date 09/04/2018 Validated By Miami-Dade BCCO-VAL Certificate of Independence Referenced Standard and Year(of Standard) Standard Year Miami-Dade TAS 100(A) 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option C Date Submitted 08/16/2016 Date Validated Summary of Products FL* Model,Number or Name Description 2847.1 Lo-OmniRidge LOR9-4 Gun Nailable 4'Ridge Vent for 9"Cap Shingles Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 R8 II 1-0119-4 13070110.Ddf Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FL2847 R8 AE LOR9-4 13070110.odf ventilation.2.Omni Roll Ridge Vent shall not be installed on roof hips.3.Omni Roll Ridge Vent shall not be connected at ridge intersection,nor within 12"of any side wall or roof protrusion,with a ventilation slot clearance of 12"from such obstructions.5.Omni Roll Ridge Vent shall not be Installed on roof mean heights greater than 33 feet. 2847.2 Lo-OmniRoll LOP-30 30'Gun Nailable Shingle Over Ridge Vent Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 R8 II LOR-30 13070111.odf Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other: 1.Refer to applicable building codes for required FL2847 R8 AE LOR-30 13070111.Ddf ventilation.2.OmniRidge Vent shall not be installed on roof mean heights greater than 33 feet. 2847.3 OmniRidge OR-4 4'Shingle Over Ridge Vent Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2847 R8 II Lomanco OR-4-NOA 16051027.Ddf Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL Impact Resistant:N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:1.Refer to applicable building codes for required FL2847 R8 AE Lomanco OR-4-NOA 16051027.odf ventilation.2.OmniRidge Vent shall not be installed on roof mean heights greater than 33 feet. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: