503 x:' FL* FL2847-118
Application Type Revision
Code Version 2014 i
Application Status Applied For
i
Comments
Archived q
Product Manufacturer Lomanco,Inc
Address/Phone/Email 2101 West Main Street
Jacksonville,AR 72076
(501)982-6511
acarter@lomanco.com
Authorized Signature Andrew Carter
acarter@lomanco.com
I -
Technical Representative Andrew Carter
Address/Phone/Email 2101 West Main Street a
Jacksonville,AR 72076
(501)982-6511 Ext 361
acarter@lomanco.com
Quality Assurance Representative Andrew Carter
Address/Phone/Email 2101 West Main Street
Jacksonville,AR 72078
(501)982-6511 Ext 361
acarter@lomanco.com I
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Product Evaluation Entity
u
Evaluation Entity Miami-Dade BCCO-EVL jf
Quality Assurance Entity Miami-Dade BCCO-QUA
Quality Assurance Contract Expiration Date 09/04/2018
Validated By Miami-Dade BCCO-VAL l
i
Certificate of Independence i
Referenced Standard and Year(of Standard) Standardr
iyea
Miami-Dade TAS 100(A) j 1995
I
Equivalence of Product Standards
Certified By
Sections from the Code
i
i
Product Approval Method Method 1 Option C
I
i
i
f
i
I
Date Submitted 08/16/2016
Date Validated
Summary of Products
FL# Model,Number or Name Description
2847.1 Lo-OmniRidge LOR9-4 Gun Nailable 4'Ridge Vent for 9"Cap Shingles
Limits of Use Installation Instructions j
Approved for use in HVHZ:Yes FL2847 R8 II LOR9-4 13070110.Ddf
Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL
Impact Resistant:N/A Created by Independent Tlilird Party:
Design Pressure,N/A Evaluation Reports
Other:1.Refer to applicable building codes for required FL2847 RS AE LOR9-4 13070110.odf
ventilation.2.Omni Roll Ridge Vent shall not be installed on
roof hips.3.Omni Roll Ridge Vent shall not be connected at
ridge intersection,nor within 12"of any side wall or roof
protrusion,with a ventilation slot clearance of 12"from such
obstructions.5.Omni Roll Ridge Vent shall not be installed
on roof mean heights greater than 33 feet.
a
2847.2 Lo-OmniRoll LOP-30 30'Gun Nailable Shingle Over Ridge Vent
Limits of Use Installation Instructions]
Approved for use in HVHZ:Yes FL2847 R8 II LOR-30 13070111.odf
Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL
Impact Resistant:N/A Created by Independent.T"Ird Party:
Design Pressure:N/A Evaluation Reports
Other:1.Refer to applicable building codes for required FL2847 R8 AE LOR-30 13070111.Ddf
ventilation.2.OmniRidge Vent shall not be installed on roof i
mean heights greater than 33 feet.
2847.3 OmnlRldge OR-4 4'Shingle Over Ridge Vent
Limits of Use Installation Instructions)
Approved for use in HVHZ:Yes FL2847 R8 II Lomanco OR-4-NOA 46051027.Ddf
Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL
Impact Resistant.N/A Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other: 1.Refer to applicable building codes for required FL2847 RS At: LD27.Ddf
ventilation.2.OmniRidge Vent shall not be installed on roof
mean heights greater than 33 feet.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovrloht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to alpublic-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact850.487.1395.*Pursuant to section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public recard.On.do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine If you aFe a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
' Safe
I
f
i
t
� it
Florida Building Code Online http://ivww.floridabuilding.org/pr/,pxapp -1AUEVX.--
dtl.aspx?pararn=
PubucatiDns Fsc staff Ems site Ma
8CIS Home Log In User Registration Hot Topics Submit Surcharge Slats&Facts
Business: :_
I. Product A
zp..
'- USER:Publipprovalc User
Pr ssib! al
> OLA-11.1rgqt >ApaLotjan�[�. >Application Detail
FL# FL2569-R11
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-USJ00000
(819)478-24GO Ext 3327
mernathieu@soprema.call
if
Authorized Signature Marc-Etienne Mathieu
memathleu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 100000
(819)478-2400 Ext 3327
memathieu@soprema.cal�
Quality Assurance Representative Jean-Francois Cote, Ph.D
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from al Florida Registered Architect o
Florida Professional Engineer.
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J. M. Nieminen 1�
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, RE
of 1/5/24 16 3:08 PM
ilorida Building Code Online http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX...
:4 Validation Checklist-'Hardcopy Received
Certificate of Independence ,L25o_9_ 11 Ct7I 2Qi 01 CQ-1 Niemineq,gc
Referenced Standard and Year(of Standard) Standard
ASTM D1970
ASTM D6163
ASTM D6164
FM 4474
FRSA/TRI April 2012 (04-12)
TAS 103
TAS 110
Equivalence of Product Standards
C6r1tified By
i
Sections from the Code
. . i
Product Approval Method Method 1 Option D i
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
i
t
Summary of Products
FL# Model,Number or Description
Name
J
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL2569 R11 II 2015 10 FINAL FR SOPREMA CA UNDERLA`:'P
Approved for use outside P.11
HVHZ:Yes Verified By: Robeft Nieminen, P.E.,PE-59166
Impact Resistant:N/A- Created by Independent Third Party: Yes
Design Pressure: +N/A/-90 Evaluation Reports
Other: 1.) Refer to ER Section 5 for EL2569 R11 AE 2015 10 FINAL IER SOPRcMA.CA UNDERLAY
Limits of-Use. 2.)The design pressurelit 1,pd' 11
noted herein pertains to underlayment Created by Independent Third Party: Yes
systems Used beneath adhesive-set the
systems. Refer to ER Section 5.6.4 for
details.
i�
:B!ck [Next! I .
Contact Us:.1940North Monroe Street.Tallahassee FL X2399PhUne,950-487-1824
The State of Florida is an AA/EEO employer.Copyljyht 2007 2013 State of Florida.::Pr vacs 5 tement:; cc,sibii statement;:21
Under Florida law,email addresses are puhfc records.If you do not want your e-mail address vele(sed in response to a public-records req
of 3 1/5/2016 3:08 PM
i
-- i
GEVX.-
Florida Building Code Online http://www.floridabuilding.org/pr/px_app_dtl.aspx?param-
electronic mail to this entity.instead,contact the office by phone or by traditional mail.if you have any questions,please contact$50.487.
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wl
they have one.The emah provided may be used for offdal communication vilth the Icensee.Howev"eremall addresses are public record.D
supply a personal address;please provide the Dipartment with an email address which can be made 7allable to the public.To determine W yo
Chapter 455,KS,please click be—Er,
Product Approval Aowpts:
0. 'WORM
sccuritv
of 1/5/2016 3:08 PM
EXTERIOR RESEARCH Rt DESIGN,I.I.C.
C�rtificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
T �N � a 3`� OXFORD,CT 06478
PHONE:{203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Soprema,Inc. Evaluation Report S18010.06.09-R9
1640 rue Haggerty I FL2569-R11
Drummondville,Quebec.12C 5138 Date of Issuance:06/15/2009
Canada i Revision 9:10/12/2015
SCOPE:
This Evaluation Report-is issued under Rule 61G20-3 and the applicable rules and regulations governing thee use of
construction materials in the State of Florida,The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code; Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2i 14) Florida Building Code
sections noted herein.
(DESCRIPTION: Soprema Roof Underlayments
I
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTIN IED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTisEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising.literature. If any portion of the Evaluation Report is displayed,then it shall be done in-its entirety..
INSPECT.tON:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building.Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
x4l a a,rrerr���
Robertl.M.Nieminen,P.E. :"O���cr•�^�C},rte`: The facsimue.sealapRea rtngwdsauthorized hyRobert Nieminen,
����S r•,,.•� PS on 10/1212015.This does not servads an electronically signed
Florida RegistratlonNo.59156,Florida DCAANE1983 i..��j�,�Cf�� �`�` document.SWned,sealedhardcopieshave been transmittedtothe
a Product Approval Adrolnistrdtor and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, not does it intend to acquire.or will it acquire, a financial interest in Iny company manufacturing or
distributing products it evaluates.
Z. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the.evaluatlon reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in-the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E.are, in any way,the.Designer of Record for any
project an which this Evaluation Report;or previous versions thereof,is/was used for permitting or.design guidance unless retained
specifically for that purpose.
II
t
it
_ _ I
i
s°
VI
�, TRINITY, ED
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
I
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following 'Standards.
Compliance is-subject to the installation Requirements and Limitations/Conditions of Use set forth herein.
x. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 i 2009
1507.2.9.2,1507.4.5.1, i
1507-5.3,1507.7.3
1507.11.2 Physicai Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005.
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 2000
1507.3..3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Enti y Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05=2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 it 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 I 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-111 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1976 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 j 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SCSS20.14 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 j 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/07/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation i Exp.10/16/2017
I -
4. PRODUCT DESCRIPTION:
1
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced,!SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene- surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
it
Exterior Research and Design,LLC EIvaluation Report S28010.06.09-119
Certificate ofRuthorizotion#9503 1.2569-1111
... Revision 9:10/12/2015
Page 2 of 7
i
I
I
IN
wovenpolyethylene surfaced hi h��tem erature, SBS modified
4:4 Lastobond Shield HT is a self-adhering, g P
bitumen roof underlayment.
4:5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SIBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high;temperature, SBS modified
bitumen roof underlayment.
4.7 Lastobond. 195 is a self-adhering, glass-mat reinforced, sand-surfaced, IBS modified bitumen roof
underlayment.
4.8 Lastobond is a self-adhering; glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen
roof underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified .bitumen roof
underlayment,with a 36-inch sheet width.
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self=adhering,glass-mat reinforced,sand-surfaced,SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment,with a 44-inch sheet width. .
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced,11 BS modified bitumen roof
underlayment.
4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced; SBS.modified bitumen roof
underlayment.
5. LIMITATidnis:
j
5.1 This is a building code evaluation. Neither Trinityi.ERD nor Robert Nieminein, P . are, in any way, the
Designer of Record for any project.on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose,
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. if not listed,a request may be'made to the AM for approval
based on this evaluation combined with supporting data for the prepared roof covering:
5.5 Allowable.roof covers applied atop the underlayments are follows:
TABLE 1: ROOF COVER OP7iON5
Asphalt Nail-Ori Foam-On �� Wood Shakes&
Underlayment Slate
Shingles Tile Tile Metal Shingles
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5:1
Lastobond Shield/Pro HT-N/ Yes No No No ` Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-5 Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Exterior Researcb and Design,LLC. Evaluation Report 518010.06.09-R9
CerdfrcateofAuthoiizoNon#9503 FL2569-R11
Revision 9:10/12/2015
j Page 3 of 7
i
I
I
I
TRINIT"Y":ERID-
TABU:1: ROOF COVER OPTIONS
Asphalt Nail-On Foam-On MetalWood Shakes& Slate
Underlayment Shingles Tile Tile l Shingles
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes. No No No ! Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes I Yes Yes
Yes
Colphene FR GR Yes Yes Yes Yes
See 55.1 No I'
Unilay(e) Yes Yes yes No No No
Batten Only See 5.5.1
5.5.1 "Foam-On tile" is limited to.use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBoiid'"'Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
5.6 Allowable substrates are noted below: i
5.6.1 Direct-Bond to Deck:.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195,. Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO L81244 or Lastobond Smooth Seal HT applied to:
Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
i Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment. f
5.6.2 Bond-to-insulation:
i
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond,. Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to.:
)1- Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For Installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
i
i
Exterior Research and Design,LLC. Evaluation Report S18016.0&09-119
Certificate ofAuthorlmNoa#9503 ( FL2569-R11
Revision 9:10/12/2015
itPage 4 of'7
i
9
5.6.3 Bond to Mechanicallv Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY
0,
Lastobond Shield HT Lastobond Pro
�i
Lastobond ECO RESISTO LB1236 Grip-Rite Eave &
d TU T Lastobond Lastobond 195 Last P
NT-S, Lastobond H ,
Valley Protector,RESISTO LB124.4„Lastobond Smooth Seal HT or Colphene FR GR applied to:
➢ ASTM D226,Type i or II felt;Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof-coverings, base,layer shall be attached per-
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TR1 April 2012(04-12).
.5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems;where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used.in foam-ori the applications.
Maximum Design Pressure is the result of testing for wind load resistance basted on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FAC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6:4:1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 6000
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: 5opra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and.6-inch o.c.in three,equally
spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered I
5.6.4.4 Maximum Design Pressure=-90.0 psf !
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or Soprafix
Metal Batten Bar(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c.within the 5-
inch wide, self-adhering side laps. End laps are 6-inch wljde and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations: j
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave & i
Valley Protector or RESiSTO LB1244 shall not be left exposed for longer than 30-days after installation.
11
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for iongerthan 180-days.after
installation.
�I
f
Exterior Research and Design,LLC. Evaluation Report S1801.0.06.09-R9
Certijxate ajAlirhorizaHon 119303 it FL2569-11II
.:Revision 9:10/12/2015.
Page5 of 7
I
I
. ,
'r
�
�
�����J� � T ^�
- _' — �
6, INSTALLATION: U
6.1 Soprema Rom underlayments shall be installed in accordance with Sopl ema published installation
' requirements subject
6.2 Ra-fasten any| decking my and check for protruding nail heads.
to remove any dust d debris h hcatio d prmne the
Elastocol'600c(if applicable).
6.3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield
HL Lastobond Pro HT-S,Lastobond,Lastobond 195,Lastobond Eco. Ustoborid Smooth Seal HT,RESISTO
L81236,Grip-Rite Eave&Valley Protector,RESISTO L81244 or Colphene FR:G,k:
6'3.1 Shall be installed / o with the / nr for *u/xx uzy/o underlayment in FBC Sections
�
1507 for the type of preparedvoorcovenngnooe/nsta000
6.32 Non-Tile Applicati6ns:
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 600r,if the-final
roof cover is not slated for'installation within.24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release.film. i
=°"=="~~~~.~~.'~.^~ ,~~.~~.~..~.....~. ~`.~.....~,..^..~~~
j as far as possible.
Once the entire length of membrane is in place, peel-off the release film Jiagonally while holding the-
""=`"°"""""e'^ Firmly roll"the membrane^into place^~achieve~bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
Inches and sta*ggered not less than 2-ft from vertical seams in the course below. All over�granule end-laps
shall be sealed using either heat-welding or hot air welding techniques. il
When installing at slopes above 8:12,Soprema recomrrfendg back-nailing in th�'e overlap area-at the top of
the sheet at 12-inch o.c.
` For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the rel�ease paper and center sheet
over valley or ridge. Drape and press sheet into place,working from toeum
each direction; For valleys,apply the sheet starting"`the lowest work upward.
b�.3 -rile ApRilcations(Lastobond TU HT or Colohene FR GR only):
Reference is made to FR54/TR 804'1IInstallation Manual 11 the
�
For foam-on tile applications, reference is-made toSection a`s.4herein for wind resistance limitations that
fall outside the scope ofFR3/VTn April 2012(04-12).
ll|e shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
. undodaymert.
U
6.4 Unilayfe):
6.4.1 Non-Tile Applications or Nail-On.Battened Tile Applications:
Reference Is made to Table I herein and RSA/TR (04'12)Installation
"pp, sheet parallel to the roof edge and, starting at the =^~ with
mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-
nails spaced 36-inch o-c. Apply the.second course in a water-shedding man 11 ner with self-adhering side-
laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight
Vertical seams should be 6-inches and staggered not less than 2-ft from ve' rtical seams in the course
All
ot
-ranule end-laps shall be sealed using -or h
U -
'
� .
�
Exterior Research and Design,uc Evaluation Report S18010.06.09-119
Cerdficate"oAuth^mzamanxs,m FUsse�-11
~
Revision w14uz/2015
Page ovrz
�
�
:
U
� :
f
Q TY- I RD
Tile(if applicable)shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment:
6.4.i Foam-On Tile Applications:
Reference is made.to FRSA/TRI April 2012 (04-12) Installation Manual,Table I herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting at the eave with, the seivedge-edge upslope,
mechanically.attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(PBB)or
Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vlgorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either.heat-welding or hlot air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to .the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the.installation of
this.product. j
.8. MANUFACTURING PLANTS:
Contact the manufacturer or the named, QA entity for information on plants covered under Rule 61G20-3 QA
requirements.
I
9. QUALITY AssURANC£ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
I �
I
i
i
i
i
Exterior Research and Design,I.I.C. EWIuatlon.Report 518010.06.09-R9
Certificate ofRuthorkatlon.0503 FL M9-R11
Revision 9:10/12/2015
Page 7,of 7
i
I
7/8/2016 Florida Building Code Online
'••�:'I`ate'I.s:ij•r : lysM SCIS Home Log In i User Registration { Hot TopicsI Submit Surcharge Stats&Fads Publications FBC Staff i BCIS Site Map Links ; Search
�r I
Busines �'�'
r�yf cf �y��sI *USER:
PIW1eJ{,J, 1"Ip Product Approval
Public User
I4S.•gI..�IiGL'FJi i
Product ADDroval Menu>Product or Aoolication Search>Aoolication List>Application Detail
L
FL# FL7006-119
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commissianllif necessary.
Comments
ii
Archived ..
Product Manufacturer IKO Industries, Ltd
Address/Phone/Email 40 Hansen Road South i
Brampton, NON-US L6W 3114
(708)496-2800 Ext 200
rmetzBOI@tampabay.rr.com
I
Authorized Signature Robert Metz
rmetzOQI@tampabay.rr.com
i
Technical Representative Bob Metz
Address/Phone/Email REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg,FL 33703
(727) 776-5261
rmetz001@tampabay.rr.com
Quality Assurance Representative Don Shaw F
I
Address/Phone/Email IKO Industries LTD
120 Hay Rd. i
Wilmington, DE 19808
(717) 579-6706
don.shaw@iko.com
Category Roofing
Subcategory Asphalt Shingles
j
Compliance Method Certification Mark or Listing
Certification Agency FM Approvals-CER
Validated By Locke Bowden
s" Validation Checklist- Hardcopyi Received
. i
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 modified to 110 mph 2009
ASTM D3462 2009
ASTM D7158 Class H 2008
ASTM E108 2007
I
1
I
Equivalence of Product Standards
Certified By
httpslAvww.floridabLilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgse7mYBc[2b3K6mXtoZLhNV)(122Np170,11E%3d 1/3
I
j
t
7/8/2016 Florida Building Code Online
�i
I
Product Approval Method Method 1 Option A
it
Date Submitted 06/28/2015
Date Validated 06/30/2015
Date Pending FBC Approval
Date Approved 07/06/2015
i
Summary of Products
FL# Model,Number or Name Description
7006.1 Cambridge, Cambridge HD and CRC Laminated architectural fiberglass asphalt shingle
Biltmore AR manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.;
Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants
Limits of Use Certification Agency Ce'itificate
Approved for use in HVHZ:Yes FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15-
Approved for use outside HVHZ:Yes 2015 .odf '
Impact Resistant:N/A FL7006 R9 C CAC FM L Iter-ASTM d3462 letter-5 6
Design Pressure: N/A15.odf j� I
Other: FL7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3
15 .011 Assurance Contract act Expiration Date
12/31/2020
Installation Instruction)
FL7006 R9 II IKO-133-02-01 Letter-Installation
Instructions for FBC FL70b6.t)df j
Verified By: Duc T Nguyen 65034
i Created by Independent Third Party: No
Evaluation Reports i
Created by Independent Third Party:
a _
7006.2 Hip and Ridge 12 Cap fiberglass This is a 12"x 12"fiberglass asphalt shingle used to cover
shingles the hip and/or ridge of,an asphalt shingle roof system
manufactured in Toronto;Ont. and Brampton, Ontario
Limits of Use Certification AgencyCertificate
Approved for use In HVHZ:Yes ( FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15-
Approved for use outside HVHZ:Yes 12015 .odf
Impact Resistant: N/A j FL7006 R9 C CAC FM Ll tter-ASTM d3462 letter- 5 6 j
Design Pressure: N/A 15.odf
! Other: 1 L7006 R9 C CAC FM L tter-ASTM E 108 letter= 5 3
15 .odf
Quality Assurance Conti act Expiration Date I
12/31/2020 11
Installation Instructions
FL7006 R9 II Hit)and Ridge Cap Shinole Installation
Instructions.odF r
FL700b R9 II IKO-133-2-01 Letter-Installation
Instructions for FBC FL7006.odf
Verified By: Duc T Nguyen PE 65034 j
Created by Independent; Third Party: No j
fEvaluation Reports !
Created by IndependentIThird Party: 1
7006.3 1 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at
j Starter Strip the bottom of a roof system manufactured in Brampton and
Hawkesbury,Ontario plants
Limits of Use Certification Agency Certificate !
Approved for use in HVHZ:Yes FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15-
Approved for use outside HVHZ:Yes 2015 .Ddf11
Impact Resistant:N/A FL7006 R9 C CAC FM Letter-ASTM d3462 fetter- 6
Design Pressure: N/A I iS.adf II
Other: EL7006 R9 C CAC FM Letter-ASTM E 108 letter- 5 3
J 1�_ 'l
Quality Assurance Contract Expiration Date
f 12/31/2020
I Installation Instructions
FL7006 R9 II IKO-133-02-01 Letter- Installation
Instructions for FBC FL70b6.odf
FL7006 R9 II Roofing-Products-Leading-Edge-Plus-
Applicatlon-EN(1).odf it
Verified By: Duc T Nguyen PE 65034
j Created by Independent Third Party: No j
Evaluation Reports
Created by Independent7hird Party: E
7006,4 Marathon 25 AR,CRC Superglass 3 tab fiberglass asphalt shingle manufactured at IKO's
hUpslAvww.floridabLilcing.org/pr/pr app dtl.aspx?param=wGIVXQwtDgse7mYBd2b3K6mXtoZLhN\/X]22Npi7OJlE%3d 2/3
it
i !
7/8/2016 Florida Building Code Online
M25AR Brampton,Ontario, Hawkesbury Ont.,Toronto, Ont.; {
Sylacauga,AL and Kanakakee,IL plants II
Limits of Use Certification Agency Certificate -�
Approved for use in HVHZ:Yes FL7006 R9 C CAC FM Letter-ASTM d3161 letter- 4-15-
Approved for use outside HVHZ:Yes 2015 .odf 'I
Impact Resistant: N/A FL7006 R�S$Q FM Lt'tter-ASTM d3462 letter- 5 6
Design Pressure:N/A 15.pdf ij
other: FL7006 R9 C CAC FM Letter-ASTM E 108 letter- S 3
I
15 .odf
Quality Assurance Contract Expiration Date i
12/20/2020
Installation Instructions
FL7006 R9 II IKO-133-02-01 Letter-Installation
Instructions for FBC FL7006.pdf
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports 1t
Created by Independent! hird Party:
' Wacie Rlert �,
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2613 State of Florida.::Privacy Statement::Ac essibility Statement::Refund Statement
I!
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please'lcontact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one:The smalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter
455,F S.,please click here.
Product Approval Accepts:
S C izt I
i
CrGt hard' .
Safe
. i
:I
i
I
I
I
I
i
i
i
i
i
i
I�
i
I
https:/www.goridabui1cing.org/pr/pr_app dtl.aspx?param=WGEVXQwtDgSe7MYBd2b3K6mXtOZLhNVX[22Npl7GJlE%3d 313
I
• jl
<FM Al
i Moml*r of Ike f.'M 0,dWnli
FM Approvals
1151 Boston-Providence Turnpike
I
P.O.Box 9102 Norwood MA 02062 USA
T:781762 4300 F:781 762 9375 www.fmapprovals.com
May 3,2015
I
Mr.Donald Shaw +
IKO Industries,Ltd.
40 Hansen Road South
Brampton,Ontario L6W 3H4
Canada
I
Customer ID: 1000000686
Subject: IKO Industries Ltd.'s FM Approved asphalt roof shingles
1
Dear Mr. Shaw, j
This letter is being written following in regards to your recent inquire regarding verification of the ASTM
D3161 testing of IKO Industries Ltd's asphalt roof shingles. TKO's shingles that are FM Approved have
been tested in accordance with ASTM D3161 (reports 3040947 and 3038510). I�
FM Approvedproducts:
Crowne Slate,Cambridge,Hip&Ridge 12,Marathon 25 AR,Marathon
Ultra AR,Cambridge 1R,Leading Edge Plus,Cambridge HD,Marathon .
25,Hip&Ridge Plus,Dynasty with AnnourZone
::Cali rood Coirporatprii Inc:°.::, •;: Biltmore,Hip&Ridge 12(CRC),Superglass 25 M'AR,Superglass
Ultra AR, CRC Hip&Ridge Plus
Please be advised that shingles noted above tested to previous versions of ASTM D3161 continue
to meet the test criteria of the current version of ASTM D3161.
If you have any questions please do not hesitate to contact me.
Very truly yours,
David L.Alves Phillip J. Smit
Senior Engineer-Materials Group Principal Engineer-AVP
FM Approvals FM Approvals
1151 Boston-Providence Turnpike
Norwood,MA 02062
T: 781 255 4856
E:david.alves��,fmapprovals:com
i
I
i
€X CE as FM
a�mlluvar
I�
I
it
i
0� i
I
CONSTRUCTION MATERIALS
TECHNOLOGIES
I
March 30, 2015
IKO Industries, Ltd
120 Hay Rd.
Wilmington, DE 19809
i
Re: FBC FL7006
Sir(s),
' I
I
.PRI Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2014 Florida Building Code.
This review was completed based on the receipt of following evidence from IKO Industries, Ltd:
1) IKO Shingle Application Instructions—3-Tab Shingles
(EN-3Tab_Appins_8AGXEFS-2012-11_reformatted 2013-02-rev07/13-Florida)
2) IKO Laminated Shingles Application Instructions I
(EN-Laminated`Appins_8TTEFS-2012-04_reformatted 2013-02-rev07/13-Florida)
3 IKO Hi and Ride 1
Hip g 2 Application Instructions I
(EN-HipandRidge12_3HRTri-2013-08 reformatted 2013-08) i
4) IKO Leading Edge Plus Shingle Application Instructions
(EN-3LEP-Tri-2012-06_reformatted 2013-03)
5) ASTM D3161 Test Report(FM Approvals Project No.3040947)
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and applicable code. In the event the instructions conflict, these instructions shall govern.
i
Statement of Independence:PRI Construction Materials Technologies and/or Duc ,,'Nguyen FL P.E.do not
have nor pian to acquire a financial interest in any company manufacturing or distrib ting products for which
the test reports are issued.
Signed: v'' �• `,I L Signed:
Brad Grzybo skl DucT.f� en
Managing Dfrector Florida R-B&ere Professional Engine r
P.E:Number:65034
Date: Apri130, 2015 Date: April1 30;2015
Attachments: A) IKO Shingle Application Instructions-3-Tab
8) IKO Laminated Shingles Application Instructions
C) IKO Hip and Ridge 12 Application Instructions
D) IKO Leading Edge Plus Application Instructions
IKQ133-02-01
I
I
I
PRI Construction Materials Techrologies,LLC.6412 Badger Drive Tampe,FL 33610 Tel:8i3-621-5777 Fax:61321-5840 a pdcmLcom WebSits:htlpJAnvw.pricmtcam
I
I
I
IKO
Installation Instructions for
Asphalt Shingles
Page 2 of 5
I
IKO Shingle Application Instructions — 3-Tab Shingles
(ASTM D3161; Class F—IKO Marathon 25 AR and CRC Superglass M25AR)
. i
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
i
ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC.
I
UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet overlapping the eave protection by 19",followed by fu;1136"widths overlapping
each preceding course by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves;with 2"horizontal laps and 4"end laps. Applyjmetal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements. I�
NAILING: Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least A"diameter heads,long
enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt
edge,approx. 1"and 13"from each end and 1/2"above each cutout. Drive nails straight so that nail head is
flush with, but not cutting into shingle surface.
NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight:
i
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8".
STEEP SLdPES.
�I
�I rrrz• r-t r.
�•��� `�i t �;� SEALING STRIP t.� •. t �. I • �'� �1
I f
NAILS NAILS i
DO NOT NAIL INTO dRABOVETHE-SEALING STRIP
I
s
I
PRI Construction Wedels Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813621-5777 Fax:813.621-5840 a-mall:materialstesung@pr cmtcom website:hwhvmpricmtcom
it
i
IKO
Installation Instructions for . !�
Asphalt Shingles
Page 3 of 5
it
IKO Laminated Shingles Application Instructions
(ASTM D3161, Class F-Cambridge, Cambridge HD, and CRC Biltmore AR)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENTI THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2014 FBC.
i
UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping
each preceding course by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top
of.any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long
enough to penetrate through plywood or 3/4"into boards. Use 4 nails'per shingle placed in the nail line 7-3/8"
below the top edge, approx. 1"and 13"in from each end. Drive nails straight so that nail head is flush with,
but not cutting into shingle surface.
NAILING ON STEEP SLOPES: For steep slopes of 21"per foot(60°)or more,use.fi nails per shingle placed
as shown below. Ensure that no nailis within 2"of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a, arter)spots of asphalt
plastic cement placed under the shingle 2"above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is s i lciently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 54/8".
i
I
NAILING=STEEP SLOPE 11 APPLMATION_
Usesix nails as shotivn.
t
7 3M' it
NAIL LINE ^�
rl _r7
NAILS CEMENT
PROPER APPLICATION REQUIRES THAT THE NAILS PEN71ZATE BOTH THE OVERLAY AND UNDERLAY P.iRTIONSOF.THE SHINGLE
i
i
I
. i
PRI Construction Materials Technologies,U.C.6412 Badger Drive Tampa.FL 33610 Tel:813821-5777 Fax:813-621-5840 e-mail:materialstesting@pricmt.com VYebS te:httpJA rW.pricmt00m
. i
I
IKO
Installation Instructions for
Asphalt Shingles
Page 4 of 5
IKO Hip and Ridge 12 Application Instructions
(ASTM D3161, Class F—IKO Hip and Ridge 12)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
i
Cut hip and ridge shingles into thirds, using the perforation marks as a cutting gulcle. These shingles are
designed for a 51/8"(130 mm)exposure.(For a neater appearance,the top of each'side of each piece has
been factory trimmed on a 1"(25 mm)taper(see drawing).Bend each piece over the hip or ridge,and nail 5
5/8" (143 mm)above the butt edge 1" (25 mm) in from each edge, exposing each 'piece 5 1/8" (130 mm).
Apply hip pieces starting at the lower end of the hip, working up toward the ridge.'O'n hip roofs,apply ridge
pieces starting at each end, meeting in the middle. On gable roofs, apply ridge pieices starting at the end
opposite to the prevailing wind direction and continue to the other end. Note:To obtain a three-dimensional
effect,(which is recommended,but not required),apply hip and ridge shingles doublel thickness bystacking 2
pieces on top of one another,the lower piece extending about 3/4"(19 mm)further than the top piece(see
diagram).The final shingle should be set in cement,and the exposed nail heads of the final shingle should be
covered with cement. Prior to application in cold weather,storing the shingles in a heated area will allow for
easier bending. j
NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEYARE DESIGNED FOR USEAS HIP AND RIDGE
SHINGLES ONLY,AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS.WE ASSUME NO
RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO
PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE,TO PROVIDE PROPER
VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQ 11
REVIEW
ALLAPPLICABLE BUILDING CODES,-MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR
TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS.
3 R
Rvn; � mmt
W _ t c«r
9i7lT � \
!f�
6 X16'
ns.mmt
i
i
i
I
I
r
i
i
PRI Construction Materials Technologies,U.C.6412 Badger Drive Tempa,FL 33610 Tel:613.621-5277 Fax:613-621.5640 e-mail:materialstesang@pricmt.com WebSite:http.'/Avww.pricmt.com
I
it
I
IKO
Installation Instructions for
Asphalt Shingles
Page 5 of 5
I'
IKO Leading Edge Plus Application Instructions
(ASTM 133161, Class F—IKO Leading Edge Plus),,,
i
NOTE: THESE INSTRUCTIONS SHALL BE USED IN. CONJUCTION WITH IKO'S PUBLISHED
r'+ 11
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
i
1. Apply any underlayment,eave protection,valley flashings, or drip edges to roof deck as required.
2. Each 39 3/8"x 13114"(1000 mm x 336 mm)IKO Leading Edge Plus strip is perforated lengthwise for
separation into two(2)shingles.Take one IKO Leading Edge Plus strip and fold flat at perforation to
separate. i
3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 mm x 168 mm)and remove approximately
20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up,with the
factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves
by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with nil ails located 3"to 4"(75
mm to 100 mm)from the eave edge and-1"(25 mm)in from each end.
4. Take the leftover 20"(500 mm)piece shingle.Rotate the piece and align it vertically up the rake edge
with the factory installed sealant adjacent to the outer edge of the roof.The single should overhang
the rake edge by a nominal 1/4"(6 mm)minimum. Fasten the shingle to the roof deck with fasteners
located 3"to 4"(75 mm to 100 mm)from the rake edge and 1"(25 mm) in from each end.
5. Repeat Steps 3—4 for the right lower comer of the roof deck. i
; i
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge,with at least
3/8"(9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20
mm) into boards. Use 4 nails per shingle placed 3"to 4"(75 mm to.,, 100 mm)from
the eave edge and approximately 1"and 13"(25 mm and 330 mm)injfrom each end.
6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install
the shingles granule side up with the factory applied sealant adjacent to.tlj a eaves. The shingles
should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum.Fasten the shingles to
the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave:eOge,4 nails per shingle.
7. Apply roof shingles as per the instructions printed on each product's packag'I. Make certain the first
course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way,
the sealant on the IKO Leading Edge Plus shingles will adhere to the first-course field shingles and
help keep them from lifting in high winds.
i
i
i
i
i
i
PRI Construction Materials Technologies,LLC.6412 Badger Drive Tempa,FL 33610 Tel:813.6215777 Fax:813.621 5840 a-mac1:matedalstesUngigpdantcom WebSitB:httpJA ww.p!=Lcom
i
i
it