HomeMy WebLinkAbout5512 EAGLE DRIVE FT. PIERCE FL - SHINGLENOTICE OF COMMENCEMENT
Permit No. Tax Folio No. Jl `a' "tom 7 2H! -
L4 364, ! 4 3�CW (
State of Florida County of St. Lucie j8t,/ 11remi f1�
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement.
Legal Description of Property: (and street address if available):
(0".
General description of improvement
REROOF
Owner information or Lessee information if the Lessee contracted for the improvement:
Name C_RJ21 W.U
Address S S i '` F4-
Interest in property: OWNER
Name and address of fee simp4e titleholder (if different from Owner listed above):
Contractor's Name:
Contractor Address:
Treasure Coast Roofing
1816 SW BILTMORE PSL,FL 34984
Phone Number: 772-370-9770
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $
Name and address: Phone number:
Lender Name:
Lender's address:
Number:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided I
713.13(1) (a)7., Florida Statutes:
Name: Phone Number:
Address:
In addition to himself or herself, Owner designates
Lienors Notice as provided in Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive
r-
rc
O U
U Z
a
L
v
d�fl
W Q
L rr
LL
Y
-0
Lu
L)�( LU
S z
F p ' CL
g'Um�
ZawK,LLJo
Q
=lI
It0
�-*0�
zLLI mo
-2 LL0 �
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 yearfrom the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, 1
my know) ge and belief.
(Sig"0,ne
(Signatory's Title/Office)
The foregoing instruyhenp
B C�
Name erso
re that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
or Owner's or Lessee's Authorized Officer/Director/Partner/Manager �� �.1�p431 ,.
�01SSln SFr
i2,
;knowledged before me this day o,Ak , 2o `; Fl 122434
1✓7 as for y
Type of authority (e.g. officer, trustee) Partyon behalf of whom,ilrstrUment.was executed
(Signatur ublic- State of Florida)
(Print, Ty , or amp Commissioned Name of Notary Public)
Personally known_ or produced Identification.
Type of Identification produced JO`-----
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 212/16 Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x
PERMIT APPLICATION FOR: Roof
PROPOSED IMPROVEMENT LOCATION:
Address: 5512 EAGLE DRIVE
Legal Description: 12/345/39E HOLIDAY PINES SIO PHASE 1 LOT 93
Property Tax ID M. 1312-500-0094-000-1
Site Plan Name:
Project Name: _
Setbacks Front
Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
Lot No. 93
Block No.
TEAR OFF EXISTING ROOF. INSTAL PEEL N STICK UNDERLAYMENT AND TAMKO
SHINGLES. ROOF PITCH 5/12
iditional work to bertormed
n
under this permit – cnecK an
F]Gas Piping
apply:
Shutters
a Windows/Doors
HVAC Gas Tank
Company: TREASURE COAST ROOFING
City: FORT PIERCE State: FL
Zip Code: 34951 Fax: N/A
Phone No. 772-209-1391
Address: 1816 SW BILTMORE
Electric 0 Plumbing
11 Sprinklers
E] Generator
Roof
Total Sq. Ft of Construction: 4364
Cost of Construction: $ 14,300.00
S Ft. of First Floor:. _
Utilities. — Sewer El Septic
Building Height: 1
OWNER/LESSEE:
CONTRACTOR:
Name CARLA NICHOLSON
Name: BRIAN J MALONEY
Address: 5512 EAGLE DRIVE
Company: TREASURE COAST ROOFING
City: FORT PIERCE State: FL
Zip Code: 34951 Fax: N/A
Phone No. 772-209-1391
Address: 1816 SW BILTMORE
City: PORT ST LUCIE State: FL
Zip Code: 34984 Fax: 772-343-8358
Phone No. 772-370-9770
E -Mail: NIA
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E -Mail: TCROOFINGLLC@GMAIL.COM
State or County License: CCC1330653
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
Name:
MORTGAGE COMPANY: _ Not Applicable
Name:
Address:
Address:
City: State:
Zip: Phone:
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: Not Applicable
Name:
BONDING COMPANY: Not Applicable
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize thepermit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Nome Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencing worK or recording your IVOLICe UI l.UrnFT1t11Lt2171Cf ll.
r
_ s
_ Signature of 0whedLesAe/Ag96 Signature of Contrat /Lice e H der
STATE OF FLOR]j,�A ! STATE OF FLORIDA
COUNTY OF c (�LACt� COUNTY OF �Sv Lkk61 el
The fpr Ding instrument as acknowledgecj`before me
this day of 20 l by
(Name of person c o dging )
(Signatuf fS1;* Public- State of Florida)
Personally Known OR Produced Identification
Type of Identificati n Produced
Commission No.
Revised 07/15/2014F 192-134 ` -y
The for Ding instrument was acknowledged before me
this day of 20 ) 7 by
a �
4C-1 VV-f—
(Name of per ac, owledging )
(Sig/otukg notary Public- State of Florida )
Personally Known OR Produced Identification
Type of ldentificatio Produced ti
Commission No. ~ SO "f_
f3
N* F 122434
REVIEWS
FRONT
ZONING`.
SUPERVISOR
PLANS
VEGETATION
SEA TURTLi'1ER4GROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
arida $tlildin ode Online
https://www.floridabuilding.or/pr/pr—app_4tl-asp-,-'pararn=wGEV)L..
_ � M
f3Ci5 iinme Lin in User RegLsFratbn Hot Tapirs Submt SWCharge Stats &Fitts PuMfCatlbsis FBC Staff site Trap links Seuch
Business Product Approval
'li- rofecelonal (I USER: PUME User
11�4
ProdKt Approy4 tAemi - End—'09-r AW --!lin $111, s Ars111 athn 112 a ARp%oation Detarl
comments
Archived
Product Manufacturer TRI -BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville, IN 46410
(201) 842-2449
david.ruizOtribuiltmateriaisgroup.com
Authonzed Signature David Ruiz
david. ruiz@tribuiltmateriaisg roup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NI 07073
(201) 842-2449
david.ruiz@tribuiltmaterialsgroup.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report _ Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE -59156
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10116/2017
Validated 8y ]ohn u41. Knezevich, PF-
Validation
EValidation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1604E R3 C0I Zola_01 CO, Njemmen-Ldf
Stands!
ASTM D1970
ASTM G155
FRSA/TR1 April 2012 (04-12)
TA5 103
Year
2009
2005
2012
1995
5/24/2016 9:58 AM
I oft — — --- -- --
- FL16048-R3
FL #
Application Type
Revision
Code Version
2014
Application Status
Approved
comments
Archived
Product Manufacturer TRI -BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville, IN 46410
(201) 842-2449
david.ruizOtribuiltmateriaisgroup.com
Authonzed Signature David Ruiz
david. ruiz@tribuiltmateriaisg roup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NI 07073
(201) 842-2449
david.ruiz@tribuiltmaterialsgroup.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report _ Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE -59156
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10116/2017
Validated 8y ]ohn u41. Knezevich, PF-
Validation
EValidation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1604E R3 C0I Zola_01 CO, Njemmen-Ldf
Stands!
ASTM D1970
ASTM G155
FRSA/TR1 April 2012 (04-12)
TA5 103
Year
2009
2005
2012
1995
5/24/2016 9:58 AM
I oft — — --- -- --
.odds Building Code Online
Equivalence of Product Standards
Certified Icy
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
https://www. oridabtlilding.org/pr/pr_app_dtl.aspx?param=wGEVX.-.
Method 1 Option D
10/08/2015
10/19/2015
10/21/2015
12/15/2015
summary of Products
FL # Model, Number or Name
Description
16048.1 TRI -BUILT Roof Underlayments� .
Self -adhering, modified bitumen roof underlayments
Limits of Use —
Installation Instructions
Approved for use in HVHZ, No
FL16048R3 IT 2015 10 FINAL ER TRI -
Approved for use outside HVHZ: Yes
BLtiiT UNDERLAYMENTS FL161348-R3.Rdf
Impact Resistant, N/A
Verified By: Robert Nieminen PE -59166
Design Pressure: +N/A/ -45
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
. Evaluation Reports
of foam -on tile systems overtop the self -adhering
aL&048 R3 AE -415_10 FINAL ER TRI-
underlayment for one particular application. See ER Section
: BUILT UNDERLAYMENTS FL16048-R3.,pdf
5.6 for details. 2.) Refer to EP Section 5 for other Limits of
Created by independent Third Party: Yes
Use.
57 tac% _Us :: t44O tlorc Monroe Strce[ "Talahassea FT,. 32399 Pine: 650-467-U
The State of Florida is an AA/EED employer, Cn>Sv�ttt_244Z2413 state of Fbdda :: ".acy statement :: geSstttd_ tfincrrt
Under Florida law, email addresses are public records. p you do not wart your e -mal address released in response to a pudic -retards request, do not send electronic
mal to this entity. instead, contact the office by phone or by Vadf,lonal mall it you have any questions, please contact 850.487.13'95. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one_ The emacs provided may be used for offival rnmmunication with the Icersee. However emal addresses are public record. tr you do not wish to supply a
personal address, piease provide the Department with an emal address which can be made available to the public. _rb determine r you are a licensee under Chapter
455, F.S„ please click hg[L.
Crodtla App—, Accepts:
I a_ra,
e, uro�
Qi� rxil
2 o£ 2 5/24/2016 9:55 AM
EVALUATION REPORT
Allied Building Products Corp.
dba TRI -BUILT Roofing Products
9050 Louisiana Street
Merrillville, IN 45410
SCOPE:
EXTERIOR RESEARCH & DESIGN, LLC.
Certificote of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report A42960.10.12 -R3
FL16048-R3
Date of Issuance: 10/25/2012
Revision 3: 10/08/2015
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 50` Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUELT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein,
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each, Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity}ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5_
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59165, Florida OCA ANE1983
CERnFICATION OF INDEPENDENCE:
1. TrinitylERD doses not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor wil} acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5, This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose,
vS��YV•y/di
~�Q4�
_
••`y�;t-�
The facsimile seafappearing +'mss au:FmriF[d by Robert hlieminLn,
iots
..Jl)J\•o. i
P.E. on 10/D8/2015. This doesnolse a asap ekctranicalfysigned
document. Signed, sealed nardcoples have been transmitted to the
Prodvet ApprMal Administrator and to the named client
CERnFICATION OF INDEPENDENCE:
1. TrinitylERD doses not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor wil} acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5, This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose,
I RINI TY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: underlayment
Compliance Statement: TRI -BUILT Roof Underlayments, as produced by TRI -BUILT, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein -
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, 1507,2.8, 1507.2.9.2,
Physical Properties
ASTM D1970
2009
1507.4.5.1, 1507.:5,3, 1507.7.3
Physical Properties
540540.11.13
11/19/2013
1504.6
Accelerated Weathering
ASTM G155
2005
1507.3.3
installation Practice
FRSA/TRI April 2012 (04-12)
2012
1523.6.5.2.1
Physical Properties
TRS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ERD iTST6049)
Physical Properties
540540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
540540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
540540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
544870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
544870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
544870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
543530.02.14-1-R1
05/14/2014
ERD (TST6049)
Physical Properties
543530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
540540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
5[8520.04.15
05/27/2015
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing 816814
09/04/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlayments:
4.1.1 Tri -Built Sand -R 5A Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36 -inch sheet width.
4.1.2 Tri -Built S/A HT TU Underlayment is a seif-adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri -Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, 513S modified
bitumen roof underlayment.
5. LIMITATIONS:
5-1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E, are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5-2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, LLC Evaluation Report A42960.10.12 -R3
Certffkate of Aurhothation 99503 FL16048-R3
Revision 3: 10/48/2015
Page 2 of 5
R N11y ERD
5.4 TRI -BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments areas follows:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
wood Shakes
Slate
Shingles
Sfiingles
Tri -Built sand -R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri -Built S/A HT TU
I
Yes
Underlayment
Yes
Yes
See 5,5.1
Yes
Yes
Yes
Tri -Built Smooth HT S/A
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long
term aging data from an accredited testing laboratory is provided.
i Tri -Built S/A 14T TU Underlayment with 3M' 2 -Component Roof Tile Adhesive AH -160 (FL6332) or Dow
TileBond— Roof Tile Adhesive (FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck:
Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A
Underlayment applied to:
+ Plywood; ASTM D41 primed plywood; 058; ASTM D41 primed OSB; ASTM D41 primed structural
concrete.
While not required over plywood, 0513 or Southern Yeliow Pine substrates, TRI -BUILT recommends priming
the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI -BUILT requires
tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -
adhering underlayment.
5.6.2 Band -to -Insulation:
Tri -Built 5/A HT TU Underlayment applied to:
> Dens Deck Prime; SECU ROCK Gypsum -Fiber Roof Board.
Far installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on the systems, insulation attachment shall be designed by a qualified design professional and
installed based on testing of the insuiation/underiayment system in accordance with FM 4474, Appendix D
or TAS 114, Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base Sayer shall be attached per
minimum codified requirements. For installations under foam -on the systems, base layer shall be attached
per minimum requirements of FRSA/TRI April 2012 (04-12).
Exterior Research and Design, LLC Evaluation Report A42950.10.12 -R3
CertJfkate of Authwizarian #9303 FL16048•R3
Revision 3: 10/0812015
Page 3 of 5
TRINITY
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on the systems, where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underiayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure = -45.0 j2sf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered.
5.7 Exposure Limitations:
5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT 5/A Underlayment shall not be left
exposed for longer than 30-days after installation
5.7.2 Tri-Built 5/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION'
6.1 TRI -BUILT Roof Underlayments shall be installed in accordance with TRI -BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri -Built Sand -R 5A Shingle Underlayment, Tri -Built 5 A HT TU Underlayment or Tri -Built Smooth HTS A
Underlayment:
6.3.1. Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
Whiie priming is optional, TRI -BUILT recommends priming the deck if the final roof cover is not slated for
installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel --off the release film diagonally while holding the
membrane tight. Firmly roil the membrane into place to achieve a bond.
Horizontal seams should be minimum 3 -inches, configured to shed water. Vertical seams should be 6 -
inches and staggered not less than 2 -ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding or hot air welding techniques.
When installing at slopes above 8:12, Allied Building Products Corp recommends back -nailing in the
overlap area at the top of the sheet at 12 -inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward,
6.33 Tile Applications ITri-Built 5/A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment.
Exterior Research and Design, LLC. Evaluation Report A42%0.10.12-113
CerUfiwte of Authorizotfon #9503 FL16049-R3
Revision 3: 10/08/2015
Page 4 of 5
INMI` ERD
BUILDING PERMIT REQUIREMENTS:
As required by the Building Oficial or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS-
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements,
9. QUALITY AssuRANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LIC. Evaluation Report A4296o.i6.12-R3
CerVfkateofAuthorlxnVon#9503 F 16048-R3
Revision 3: 10/08/2015
Page 5 of 5
odda Badin. code Online https://www.floridabuilding.ori/pr/pr_app_dtl.aspx?param�"'GEVX
Comments
Archived
Product Manufacturer TRI -BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville, IN 46410
(201) 842-2449
david. ruiz@tribuiltmaterialsg roup.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterialsgroup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, N) 07073
(201) 842-2449
david.ruiz@tribuiltmateriatsgroup.cam
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a 'Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By Sohn W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL36048 R3 Ciil 2015 01 CO! Nleminen.pdf
Standard
ASTM D1970
ASTM G155
FRSA,rTRI April 2012 (04-12)
TA5 103
Year
2009
2005
2012
1995
5/24/2016 9.58 AM
I nf2---- __—T---_
k
BCLS Home Lag In User RegLctratbn Hot Top6CS
submit Surcharge Stats & Fans
PuNicatlorts FaC Staff RCiS Site Map Unks Search
�
Buse I p Ies s
Business
Professional
/� Product Approval
E`'_ lusi:A: Pth� pe
➢t1!l9! lEl ti
Product Approval Henu > 5roWtLu ar tbn SN?4th a &o tatlon List }APA tion Oe'CaA
- FL16048-R3
FL
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer TRI -BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville, IN 46410
(201) 842-2449
david. ruiz@tribuiltmaterialsg roup.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterialsgroup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, N) 07073
(201) 842-2449
david.ruiz@tribuiltmateriatsgroup.cam
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a 'Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By Sohn W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL36048 R3 Ciil 2015 01 CO! Nleminen.pdf
Standard
ASTM D1970
ASTM G155
FRSA,rTRI April 2012 (04-12)
TA5 103
Year
2009
2005
2012
1995
5/24/2016 9.58 AM
I nf2---- __—T---_
orida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FSC Approval
Date Approved
https://www.floiidabuildin&org/pr/pr app_dtl.aspx?param=wGEVX...
Method 1 Option D
10/08/2015
10/19/2015
10/21/2015
12/15/2015
Summary of Products
FL # Model, Number or Name Description
----------._—_---._-..___...__�.----_---
16048.1 TRI -BUILT Roof Underlayments Self -adhering, modified bitumen roof underlayment
Limits of Use — Installation Instructions
Approved for use in HVHZ: No FL16048 R3 II 2€115 10 FINAL ER TRI -
Approved for use outside HVHZ: Yes BUILT Ji DERL AYMENTS FL16048-R3.Rdt
Impact Resistant: N/A Verified By: Robert Nleminen PE -59166
Design Pressure: +N/A/ -45 Created by Independent Third Party: Yes
Other. 1.) The design pressure noted herein pertains to use Evaluation Reports
of foam -on tile systems overtop the self -adhering FL16046 R3 AE 2015 10 FINAL ER TRI-
underiayment for one particular application, See ER Section BUILT UNDE§�LAYMENT5 FL16048-R3.pdf
5.6 for details. 2.) Refer to ER Section 5 for other Limits of Created by Independent Third Party: Yes
Use.
C�t�U-S _: 1440 Norah Monroe Street 321ahassee FL 32349 Phane854jFa7-1624
The State of Florida is an AA/EEO employer. raavriotst 7-007-2013 State of Flortla. ; : PAvacv Statement :: :: 3rd3LrKL_Sta1-CfAent
Under Florida law, emal addresses are public mrnids. It you do not want your a -mall address released In response to a pudic -records request, do not send eleamnt
mal to this entity. Instead, contact the ofh4e by phone or by traditional mall. If you have any questions, please contact 650.487.1345. *Pursuant to Section
455.275(1), Florida Statutes, eftective October 1, 2012, kensees litessed under Chapter 455, F.S. must provide the Department with an ema8 address If they have
one. The emacs provtled may be used for official communication wth the licensee. Hawever ernal addresses am puhit retort!. If you do not wish to supply a
oersonal address, please provide the Department wth an emal address which can be made available to the pubic. To deternrlm r you are a licensed under Chapter
4 S5, F5., please click here_.
PradLK2 Approval Awepts:
1 W eL
2 of 2 5/24/2016 3:58 AM
TRIlk 11, 11 � $
EVALUATION REPORT
Allied Building Products Corp.
dba TRI -BUILT Roofing Products
9050 Louisiana Street
Merrillville, IN 46410
SCOPE:
EXTERIOR RESEARCH & DESIGN, LLC..
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT ##13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX. (203) 262-9243
Evaluation Report A42960.10.12 -R3
FL16048-R3
Date of Issuance: 10/25/2012
Revision 3: 10/08/2015
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P -E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the St' Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI -BUILT hoof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P_E_ if the product
changes or the referenced Quality Assurance documentation changes. Trinity] ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166 Florida DCA ANE1983
CERTINCATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nienninen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl FRO nor Robert Nieminen, P -E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
OF
'��'+
S` :'=••"' G'. ,c'
The facsimile seal appearing was auftmed Iny Robert Nierninen.
P.E.on10/08/2015. This does notserve asap clectronimllysigned
cl—rnem. Signed, seaWd'nard+wpJes have }Seen reansmined to tha
Product Apprwa{ Adminisimrcr and to the named client
CERTINCATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nienninen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl FRO nor Robert Nieminen, P -E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
(ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category:. Underlayment
Compliance Statement: TRI -BUILT Roof Underlayments, as produced by TRE -BUILT, have demonstrated compliance
with the following ser -tions of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, 1507.2.8, 1507.2.9.2,
Physical Properties
ASTM D1970
2009
1507.4.5.1, 1507.5.3, 1507.7.3
Physical Properties
540540.11.13
11/19/2013
1504.6
Accelerated Weathering
ASTM G155
2005
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
544540.02.13-1
02/19/2013
ERD ITST6049)
Physical Properties
540540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
540540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
544870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
544870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
544$70.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
S44870A4.14-4
04/40/2014
ERD (TST6049)
Physical Properties
543530.02.14-1-R1
05/14/2014
ERD (TST6049)
Physical Properties
543530.05.14
05128/2014
ERD (TST6049)
Physical Properties
540540.10.14
10/31/2014
ERD (T5T6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Acce#erated Weathering
SC8520.04.15
05/27/2015
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
09/04/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 10/16/2017
4, PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlayments:
4-1.1 Tri -Built Sand -R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36 -inch sheet width.
4-1.2 Tri -Built S/A HT TU Underlayment 15 a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri -Built Smooth HT 5/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified
bitumen roof underlayment.
5. LIMrwiONS:
5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, LLC Evaluation Report A42960.10.12 -R3
CerUficote of Rurhorizotion #9503 FL16048-R3
Revision 3: 10/08/2015
Hage 2 of 5
5.4 TRI -BUILT Root Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. if not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1.: ROOF COVER OPTIONS
Underlayment
y
j Asphalt
Shingles
Mail -On Tile
Foam -On Tile
Metal
Wood Shakes
}
& ShinglesSlate
Tri -Built Sand -R SA Shingle
Underlayment
i Yes
No
No
Yes
I Yes
Tri -Built S/A HT TU
f
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
Tri -Built Smooth HT S/A
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -Cin Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long
term aging data from an accredited testing laboratory is provided.
Tri -Built S/A HT TU Underlayment with 3M— 2 -Component Roof Tile Adhesive AH -160 (FL6332) or bow
TileBond— Roof Tile Adhesive (FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck:
Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A
Underlayment applied to:
Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; ASTM D41 primed structural
concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI -BUILT recommends priming
the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI -BUILT requires
tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -
adhering underiayment.
5.6.2 Band -to -Insulation:
Tri -Built S/A HT TU Underlayment applied to.
Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and
installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D
or TAS 114, Appendix J_
5.6.3 Band to Mechanically Attached Base Laver:
7', ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under fo2m-on tile systems, base layer shall be attached
per minimum requirements of FRSA/TRI April 2012 (04-12).
Exterior Research and Design, U.C. Evaluation Report A42960.10.12 -R3
Certffisate of Authorization #9503 FL1604$-R3
Revision 3: 10/08/2015
Page 3 of S
TRINITY ERD
5.6.4 Wind Resistance for Underly meat Systems in Foam -On Tile A lications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1.504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5,6.4.1 Maximum Design Pressure =--45 0 osf.
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Underlayment: Tri -Built S/A HT TU Underlayment, self -adhered.
S.7 Exposure Limitations:
5.7.1 Tri -Built Sand -R SA Shingle Underlayment or Tri -Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30 -days after installation
5.7.2 Tri -Built S/A HTTU Underlayment shall not be left exposed for longer than 180 -days after installation.
6. INSTALLATION. -
6.1 TRI -BUILT Roof Underlayments shall be installed in accordance with TRI -BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT SIA
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 lion -Tile applications:
While priming is optional, TRI -BUILT recommends priming the deck if the final roof cover is not slated for
installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possUe.
Once the entire length of membrane is in place, peel -off the release film diagonaiiy while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inche5, configured to shed water. Vertical seams should be 6 -
inches and staggered not less than 2 -ft from vertical seams in the course below. All over -granule end -laps
shall be sealed using either heat -welding or hot air welding techniques.
When installing at slopes above 8:12, Allied Building Products Corp recommends back -nailing in the
overlap area at the top of the sheet at 12 -inch o.c,
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. 'Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri -Built S/A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Exterlor Research and Design, LLC. Evaluatlon Report A42960.10a2-R3
Certificate of Authorliotlorr #950-4 FL16048-R3
Revision 3: 10108/2015
Page 4 of 5
TRINITY
T. BUILDING PERMIT REQUIREMENTS:
AS required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 CoA requirements.
9. QUALITY AssuRANC£ ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chanceilor@us.ul.com
-END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report A42960.30.12 -R3
Certificate of Author&atran 99503 FL16048-R3
Revision 3: 10/08/2035
Page 5 of 5
Business&ProfessionalRegulation.. ..
@CIS Home Log In User Registration Hot Topics Submit Surcharge Stats a Facts Publications FSC Staff SCIS Site Map links Search
b'
4lProduct Approval
USER! Public User
Pmr)u t Arr rnval Menu >
Product or aaoliratina S-11 > Andtcation Lit > Application Detail
�r
FL 4
FL18355-R2
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri eden@tamko.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Emal I
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE -74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
Validation Checklist - Hardcopy Received
Certificate of Independence FL18355 R2 COT TBPi 0 i.2 FBC 201-s Product Evaluation Re ert
Shi�
Referenced Standard and Year (of Standard) Standard
Year
ASTM D 3161
2009
ASTM D 3462
2009
ASTMD D 7158
2008
TAS 100
1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
12/16/2015
Date
Validated
12/18/2015
Date
Pending F3C Approval
12/19/2015
Date
Approved
02/10/2016
Date
Revised
05/09/2017
Summary of Products
FL # Model, Number or Name
Description
18355.1 Glass -Seal, Elite Glass -Seal,
ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Vintage, Hip and Ridge, and Vintage
Hip and Ridge Shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL0355 R2 ii T5P15001.2 FO ZQ14 Produpt Fvplgation
Report Shingles.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL18355 R2 AE TBP15001.2 FBC 201.4 Product Evaluation
Report Shinai s.odf
Created by Independent Third Party: Yes
&ack hFex
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 950-497-1924
The State of Florida is an AA/EEO employer. Conyrioht 2007-2013 State of Florida.:: Privacv Statemenf :: AccessibilitXStatement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. instead, contact the office by phone or by traditional mail. If you have any questions, please contact 950.497.1395. 'Pursuant to seetion 455.275
(1), Flonda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emalis provided may be used for official communication with the licensee. However email addresses are public record, It you do not wish to supply a personal address,
piease provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.5., please
dick bare .
Product Approval Accepts:
KE
Credit i
Safe
11CUrit�.1ILTI1l(1
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
TAMKO BUILDING PRODUCTS
Standard
220 West 4`" Street
PRI Construction Materials Technologies (TST5878)
Joplin, MO 64801
TAS 100
(417) 624-6644
Manufacturing Plants:
Joplin, MO
TAS 100
Phillipsburg, KS
PRI Construction Materials Technologies (TST5878)
Frederick, MID
TAS 100
Dallas, TX
PRI Construction Materials Technologies (TST5878)
Tuscaloosa, AL
Quality Assurance:
UL LLC (QUA9625)
SCOPE
TAP -117-02-01
Certificate of Authorization No. 29524
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE V EDITION (241
Category: Rooting
Subcategory: Asphalt Shingles
Cade Sections: 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Issued december 14, 2015
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP -043-02-01
TAS 100
1955
PRI Construction Materials Technologies (TST5878)
TAP -051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -131-02-01
TAS 100
1995
PRI Construction Materials Technologies (€ST5878)
TAP -165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -315-02-01
ASTM D 6381
2008(2013)31
PRI Construction Materials Technologies (TST5878)
TAP -317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2009
UL LLC (TST9628)
04NK24366
ASTM D 3462
2009
UL LLC (TST9628)
05NK23006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2008d
UL LLC (TST9628)
06NK03898
ASTM D 3161
2009
ASTM D 3462
2009
UL LLC (TST9628)
08CA59132
ASTM D 3161
2009
UL LLC (TST9628)
09NK07896
ASTM D 3151
2009
ASTM D 3462
2009
UL LLC (TST9628)
10CA50498
ASTM D 3462
2009
UL LLC (TST9628)
10CA64882
ASTM D 3161
2009
UL LLC (TST9628)
11NK14014
ASTM D 3161
2009
ASTM D 3462
2009
UL LLC (TST9628)
12CA24551
ASTM D 3161
2009
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2009
UL LLC (TST9628)
4787148748
ASTM D 7158
2008d
ASTM D 3161
2009
ASTM D 3462
2009
TBP15001.2 FL18355-R2 Pagel of 11
This evaluation report is provided for State of Florida product approval under Rule 61G26-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal@
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Ciass H self-sealing, 3 -tab
(Frederick, Joplin &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with. ASTM D 3462.
Glass -Seat
12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-t2b asphalt shingle with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shaft be used in the non-HVHZ only.
Heritage@
13-114" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium
13-1/4" x 39-3/8', ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
HeritageO Premium
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ VintageO
17-112" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Woodgate
13-114" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM t7 3462.
Heritage@ Woodgate
12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Midge Shingles
12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin)
shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage@ Hip and Ridge
12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg)
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.2 FL18355-R2 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TFCHNICAI- SERVICES, LLC
INSTALLATION
Elite Glass -Seal®
(Frederick, Joplin &
Tuscaloosa)
&
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Nailing
Area
Area
Basic Wind Speed (Vut): Max. 194 mph
Basic Wind Speed (V.w): Max. 150 mph
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Deck (HVHZ):
In accordance with FISC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction_
Deck (Non-HVHZ):
In accordance with FBC requirements;
Solidly sheathed rein_ 15132 in. plywood or wood plank for
new construction; Min. V16 in. OSB existing construction.
Underiayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
Installed with 5-1/8 inch exposure in accordance with RAS.
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
installation (Non-HVHZ):
Installed with 5 -118 -inch exposure in accordance with F13C
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
_kyul�y
ti
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattern (Non-HVHZ only)
(NAILS
1
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
-7/8"
5-118"
5-1/81,
TBP15001.2 FL18355-R2 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
FASTENERS
NAIL ZON E
COMMON
BOND
EXPOS URE6-618"
1 " 12-112" -►� 12-318" - ► -- 12-112 `-� 1 --1 "
Figure 3. Heritage@, Heritage@ Premium, and Heritage@ Wood (gate (Dallas)
4 Nail Pattern (non-HVHZ only)
N.
NAIL ZONE
COMMON
BOND
IE 5-5J8"
1'� �f-�1�'� �-1/2"-�-� �a"-►}� f-11�-�-7-1.2`►� �-1,
Figure 4. Heritage@ & Heritage@ Premium
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
NCREE
Asphalt Shingles
TECHNICAL SERVICES,
LLC
Heritage@
Basic Wind Speed (Vu„):
Max_ 194 mph
(Dallas, Frederick, Joplin,
Basic Wind Speed (Vasd):
Max. 150 mph
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 19132 in. plywood or wood plank for
Heritage® Premium
new construction; Min. 15132 in. plywood existing
(Dallas, Frederick
construction.
Phiflipsburg & Tuscaloosa)
Deck (Non-HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 15132 in. plywood or wood plank for
Heritage@ Woodgate
new construction; Min. 7/16 in. OSB existing construction.
(Dallas & Frederick)
Underlayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
4nstalled with 5-5/8 in_ exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ):
Installed with 5-5/8 in. exposure in accordance with FSC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or T Nail Pattern" detailed below.
FASTENERS
NAIL ZON E
COMMON
BOND
EXPOS URE6-618"
1 " 12-112" -►� 12-318" - ► -- 12-112 `-� 1 --1 "
Figure 3. Heritage@, Heritage@ Premium, and Heritage@ Wood (gate (Dallas)
4 Nail Pattern (non-HVHZ only)
N.
NAIL ZONE
COMMON
BOND
IE 5-5J8"
1'� �f-�1�'� �-1/2"-�-� �a"-►}� f-11�-�-7-1.2`►� �-1,
Figure 4. Heritage@ & Heritage@ Premium
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUil-DING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
NAIL ZONE/
COMMON BOND
1
EXPOSURE 5 5W
Figure 5. HeritageO Woodgate
6 Nail Pattern
0- - 12-112"
FASTENERS 0 Common Bond
PAl NT
LINE,
7-7/811
6-1/8"
-- 33-318" I
Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate
Alternate 6 Nail Pattern
ACCEPTABLE
FASTENED LOCATION
DO NOT FASTEN
ALONG EDGE OF
COMMON BOND
PREFERRED
FASTENER
LOCATION
L ZONE
EDGE OF
COMMON
BOND
OSURE
Figure 7. Heritage@) (Tuscaloosa)
Expanded Nail Zone
Nail pafterns from Figures 3, 4, and 6 may be placed in the mail zone as described above
TBP15001.2 FL18355-R2 Page S of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor impiy warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
T'EcHNiCAL. SERVICES, LLC
Heritage@ Premium Basic Wind Speed (V,,,,):
(Frederick) Basic Wind Speed (V�,a):
Deck (HVHZ):
Deck (Non-HVHZ)
Underlayment:
Min, slope:
Installation (HVHZ)
Installation (Nan-HVHZ):
FASTENERS
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in, plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
fnstructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
NAIL ZONE/
COMMON BOND
V2 11 lElIP08URE �
1,� i1"-►�r- 12" ----11`1 1
�-111
Figure 8. Heritage@ Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE(
FASTENER 5 COMMON BOND
51f2" E-T
SURE 5"
"--►� E —911243+ 9u--+-3ri 9Y21LJ*-1 n
Figure 9. Heritage® Premium (Frederick)
6 Nail Pattern
TBP15001.2 Ft_18355-R2 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify GREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
NMI
ECREEK
TF-cHNICAL SERVICES, LLC
Heritage® Woodgate Basic Wind Speed (V.1t):
(Frederick) Basic Wind Speed (Vasa):
Deck (Non-HVHZ):
Undertayment:
Min. slope:
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBG requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBG requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with FBG
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either '4 Nail
Pattern" or "6 Nail Pattern" detailed below.
V T
EXPOSURE 5"
NAIL ZONE/
COMMON BOND
11" 12-318" - 11" -� [0- 1 "
Figure 10. Heritage@ Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/ %
FASTENERS `! OOMMON BOND
T
5.112" EXPOSURE5°
Figure 11. Heritage® Woodgate (Frederick)
6 Nail pattern
TBP15001.2 FL18355-R2 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid..
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage® Basic Wind Speed (V,,,):
(Phillipsburg) Basic Wind Speed (Vas,j):
Deck (HVHZ):
Deck (Non-HVHZ):
Llnderiayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
1j
it
i-7IJ<�
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in- plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions- Shingles shall be attached using either "5 Nail
Pattern" or "6 Nail Pattern" detailed below.
TM L L
M t]�trrri2 Y
rl .H66haa �
Figure 12. Heritage® Vintage®
5 Nail Pattern (non-HVHZ only)
1G7M'
Figure 13. Heritage® Vintage'
6 Nail Pattern
rX P]3um
- Piom-h
Expmm
/Noun
17 -ler
TBF15001.2 FL18355-R2 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein-
CREEK
TAIVIKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (Vut): Max. 194 mph
(Frederick & Joplin) Basic Wind Speed (V.d): Max. 150 mph
Deck (HVHZ): In accordance with FISC requirements;
Solidly sheathed min. 19132 in_ plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
Deck (Non-HVHZ): in accordance with FBC requirements;
Solidly sheathed min- 15132 in_ plywood or wood plank for
new construction; Min. 7116 in. OSB existsng construction.
Underlayment: In accordance with FBG requirements.
Min. slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-118 inch exposure in accordance with the
FSC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start exposure
F] S
Figure 1
exposure
i„
r Fastener - Faste
-5-5"„
r��-sra„
Figure 2 1/4
4„ Figure 3
Figure 14. Hip & Ridge (Frederick & Joplin)
TBP15001.2 FL18355-R2 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify GREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
VintageO Hip & Ridge Basic Wind Speed (V„11):
(Phillipsburg) Basic Wind Speed (Vasd)
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 99132 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing.
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturers published installation instructions. The
direction of the exposed end shall be away from the
prevaiiing wind.
Direction of prevailing wind
ire
e
Start
here
Figure 1 5" exposure
1.
_ Fastener Fsstel
"-5-112"�
to
Figure 2 1/41' Figure 3
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
TBP15001.2 FL18355-R2 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Mule fit G20-3_ The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
9 CREEKTAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
i. WTATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements,
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTIVI D 7158 applies to exposure B & C with a building mean roof height of 33 -ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
d) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 5�h Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer.
,tV��r rel!r11
PrIt,'
�.
. %
2015.12.14
SPG •�`GE•N S�. �c�� i
No 74021 =
/� 13:44:19
-05'00'
13 :O•., STATE OF :4r.
-C``. P.••�
��'ifsS k;,,w`�
Zachary R. Priest, P.E.
O
Florida Registration No. 74021
rrrr /ON A' �". %
Organization No, ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.2 FL18355-R2 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
fit:
Business & Professional
SCIS Horne Log In f user Registration 1.,TOpits Submit Surcharge Stats & Facts Publications F8C Staff SCIS Site Map Links march
b3
Product Approval
USER: Public User
Product AopmuBl Menu > Product w Annlication SeaMfi > Application Lis[ > Application Detail
FL # FL18355-R2
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerr! Eden
kerri—eden@tamko.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE -74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Boyden
z' Validation Checklist - Hardcopy Received
Certificate of Independence FL18355 R2 COI TBP150012 FBC 2014 Product Evaluation Reoert
Shingle--odf
Referenced Standard and Year (of Standard) Standard
ASTM D 3161
ASTM D 3462
ASTMD D 7158
TAS 100
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2009
2009
2008
1995
Product Approval Method Method 1 Option D
Date
Submitted
12/16/2015
Date
Validated
12/18/2015
Date
Pending FBC Approval
12/19/2015
Date
Approved
02/19/2016
Date
Revised
05/09/2017
Summary of Product I
FL # Model, Number or Name
Description
18355.1 Glass -Seal, Elite Glass -Seal,
ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Vintage, Hip and Ridge, and Vintage
Hip and Ridge Shingles
Limits of Use
Installation Instructions
Approved for use in HVH2: Yes
FL18355 R2 ii TBP15001.2 FQC-2014 Product Eyaivation
Renort`5hinales.pdr
Approved for use outside HVHZ: Yes
Impact Resistant- N/A
Verified By: Zachary R. priest PE -74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL18355 R2 AF T5P15001.2 FBC 2014 Product Evaluation
Report Shinnles,od€
Created by Independent Third Party: Yes
8act< rilex
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32392 Phone: 859-487-1$Z&
The State of Florida is an ANEEO employer. Gonyight 2007.2913 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Ftorida law, email addresses are public records. If you do not wart your e-mail address released in response to a publicrecordsrequest, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 20I2, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public retard, if you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F'.S., please
click ti_e_T .
Product Approval Accepts:
e___
Credit Card
Safe
Certificate of Authorization No. 29824
R E E K17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SER Y ICEsc LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE EP EDITION (2014)
Manufacturer: TAMKO BUILDING PRODUCTS
220 West 4 t Street
Joplin, MO 64801
(417) 624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Issued December 14, 2015
Category: Rcofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5, 1507.2.7.1,
1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP -043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP -315-02-f11
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP -317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2009
UL LLC (TST9628)
04NK24366
ASTM D 3462
2009
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2008d
UL LLC (TST9628)
06NK03898
ASTM D 3161
2009
ASTM D 3462
2009
UL LLC (TST9628)
08CA59132
ASTM D 3161
2009
UL LLC (TST9628)
09NK07896
ASTM D 3161
2009
ASTM D 3462
2009
UL LLC (TST9628)
1OCA50498
ASTM D 3462
2009
UL LLC (TST9628)
1 OCA64882
ASTM D 3161
2009
UL LLC (TST9628)
11NK14014
ASTM D 3161
2009
ASTM D 3462
2009
UL LLC (TST9628)
12CA24551
ASTM D 3161
2009
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2009
UL LLC (TST9628)
4787148748
ASTM D 7158
2008d
ASTM D 3161
2009
ASTM D 3462
2009
TBP15001.2 FL -18355-R2 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKTAMKC BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal®
12-114" x 36", ASTM D 3161, Class F and ASTM 0 7158, Class H self-sealing, 3 -tab
(Frederick, Joplin &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3 -tab
(Frederick &
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462.
Glass -Seal
12-114" x 36", ASTM D 7158, Class H self-sealing, 3 -tab asphalt shingle with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage@
13-1/4" x 39-38", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium
13-114" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
compSying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium
12" x 36". ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Vintage@
17-112" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Woodgate
13-114" x 39-318', ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage@ Woodgate
12" x 36-318", ASTM D 3161, Class F fiberglass reinforced. laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only_
Flip and Ridge Shingles
12-114" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin)
shingle surfaced with mineral granules complying with ASTM D 3482,
Vintage@ Hip and Ridge
12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg)
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.2 FL18355-R2 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report fs valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES,
LLC
INSTALLATION
Elite Glass -Sea[@
Basic Wind Speed (Vult):
(Frederick, Joplin &
Basic Wind Speed (Vmd):
Tuscaloosa)
Deck (HVHZ):
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
Llnderlaym€:nt:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
Nailing
Area
Nailing
Area
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidiy sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements,
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in, OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 -1/8 -inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or `6 Nail Pattem" detailed below.
t
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattern (Non-HVHZ only)
NAILS
-7f"
5-1/81,
,-,
Buil Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
-71811
5-118"
TBP15001.2 FL18355-R2 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 6IG20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage@
Basic Wind Speed (Vat):
(Dallas, Frederick, Joplin,
Basic Wind Speed (Vasd):
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
Heritage@ Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Deck (Non-HVHZ):
Heritage@ Woodgate
(Dallas & Frederick)
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
6-118"
TANIKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBG requirements;
Solidly sheathed min. 19132 in, plywood or wood plank for
new construction; Min. 15132 in. plywood existing
constructbri.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in_ plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBG requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-518 in_ exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-5!$ in. exposure in accordance with FBG
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
FASTENERS NAIL ZONE
COMMON
BOND
EXPOSU FSE 5-518"
11Lf 12-112" 12-318" --►+- 12-112 `�_1 "
Figure 3. HeritageO, Heritage@ Premium, and Heritage@ Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
f
NAIL ZONE
COMMON
BOND
IE 5-518"
V- I --f12k4J(*-7-1/2"-11--&8'L-+-7-1)2'-H411-7-1,2"11� �-i"
Figure 4. Heritage@ & Heritage@ Premium
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 51G20-3, The manufacturer shall notify CREEK
Technical Services.. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKTAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
NAIL ZONE!
NEIftS- COMMON BON[
FEXPOSURE55W
" �7-t/2'+7-1/2' -•7-3/$+7-1f2+-112 �4-1
Figure 5. Heritage® Woodgate
6 Nail Pattern
Loa
nw
PAl NT
LINE.
9*11141.1
Common Bond
Figure 6. Heritage®, Heritage® Premium, & Heritage@ Woodgate
Alternate 6 Mail Pattern
7-718" - - - - - - -- - - _ — _ ------------ -- -- NAI L ZONE
-.EDGE OF
COMMON
BOND
EXPOSURE
5-5/8"
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
----------- _______ COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage® (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.2 FL18355-R2 Page 5 of 11
This eva#uation report is provided for State of Florida product approval under Rule 61G20-3- The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
HeritageO Premium
(Frederick)
Basic Wind Speed (Val):
Basic Wind Speed (Vand):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed rain. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with I=BC requirements;
Solidly sheathed min. 15132 in, plywood or wood plank for
new construction, Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Mail
Pattern" or "6 Nail Pattern" detailed below.
NAIL ZONE/
'COMMON BOND
E 511
12" --s } --1 „
Figure S. HeritageC5 Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
14AILZONEI
FASTENERS COMMON BOND
1 2" E)CPt SUFE 55"
Figure 9. Heritage®'Premium (Frederick)
6 !Jail Pattern
TBP15001.2 FL18355-R2 Page S of i 1
This evaluation report is provided for State of Florida product approval under Rule 61G20-3- The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid..
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
speciicaily addressed herein.
TRMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES, LLC
Heritage@ Woodgate. Basic Wind Speed (V q): Max. 194 mph
(Frederick) Basic Wind Speed (Vaud): Max. 150 mph
Deck (Non-HVHZ): in accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
Underiayment: In accordance +riith FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or `6 Nail Pattern" detailed below.
NAIL ZONE,
COMMON BOND
tT
5-112" EXPOSURE 5'°
11" 12-3/8" 11" -- k•1"
Figure 10. Heritage@ Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERSFEY110SU!
COFlIf�i0h9 MONO
5.112"
lit 9-112" 9-3X'-�*3+ 9-112" -� �11-111
Figure 11. Heritage@) Woodgate (Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 7 of i 1
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid_
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
ECREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage@ Basic Wind Speed (Vul):
(Phillipsburg) Basic Wind Speed (Vasa)
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 95132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:92.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6.Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or "13 Nail Pattern" detailed below.
4C
f Wicn
F�ten�s
17�1t2"
Lj L
5"
Ex rwu re
4.1 A, 4Va,--E�p_4:tt'--- + 9.1,w
lf: _1
Figure 12. Heritage® VintageO
5 Nail Pattern (non-HVHZ only)
Figure 13. Heritage@ Vintage
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifiically addressed herein.
offillill TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
Tr*CHNICAL SERvtc1`s, LLC
Hip & Ridge Basic Wind Speed (Wit); Max. 194 mph
(Frederick & Joplin) Basic Wind Speed (Vasd): Max. 150 mph
Deck (HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min, 15132 in. plywood existing
construction.
Deck (Non-HVHZ)i In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
Underiayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-118 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
Start 5-1/8" exposure
here-
0 u
Figure 1
1"
t
Fastener
Figure 2
Figure 14. Hip & Ridge (Frederick & Joplin)
TBP15001.2 FL18355-R2 Page B of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL. SERVICES, LLC
Vintage@ Hip & Ridge Basic Wind Speed (V„n):
(Phillipsburg) Basic Wind Speed (Va§d):
Deck (HVHZ):
Deck (Non-HVHZ):
Underiayment:
Min. slope:
Installation:
TAMKO BUILDING' PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in_ plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed mint. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
in accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start
here—
n
exposure
e
Figure 1 xposure
1"
- `FaStel
Fastener
-5-11211 /2,f
Figure 2 ,= Figure 3
Figure 1S. Vintage@ Hip & Ridge (Phillipsburg)
TBP15001.2 FL18355-R2 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
TAMKO BUILD€FSG PRODUCTS
Asphalt Shingles
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 33 -ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
71 Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 51h Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer.
"JV%J1tirllr1tr
R.
2 015.1
.14
'74021 =
� 13:44:19
No
O'' STATE OF :4tj
''.
4% �� t F;.'
`���s•
Zachary R. Priest, P.E.
R
Florida Registration No. 74021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.2 Fi_18355-R2 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.