HomeMy WebLinkAboutDrawing i
i
i
2
32" X 80"
i
,I
36" X 80"
I
I
REPLACE DOORS IN 2 OPENINGS ONLY.
NEW DOORS TO BE IMPACT RESISTANT-
SHUTTERS NOT REQUIRED.
I
i
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.1
1 36 80 20.00 4 36.1 -39.3 FL4904.1 76.0 -76.0,! FRONT ENTRY-LSMI
2 32 80 17.78 4 36.8 1 -40.0 FL22513.6 70.0 70.01 KITCHEN-LSMI
I
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS'.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
I
I
DOOR FRAME#1 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
DOOR FRAME#2 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
I '
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 1 IN
i
I
i
ALDRICH RESIDENCE
230 BANYAN DRIVE DOOR REPLACEMENT PLAN
PORT ST. LUCIE, FLORIDA
' I
i
' I