Loading...
HomeMy WebLinkAboutDrawing i i i 2 32" X 80" i ,I 36" X 80" I I REPLACE DOORS IN 2 OPENINGS ONLY. NEW DOORS TO BE IMPACT RESISTANT- SHUTTERS NOT REQUIRED. I i OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.1 1 36 80 20.00 4 36.1 -39.3 FL4904.1 76.0 -76.0,! FRONT ENTRY-LSMI 2 32 80 17.78 4 36.8 1 -40.0 FL22513.6 70.0 70.01 KITCHEN-LSMI I REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS'. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. I I DOOR FRAME#1 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. DOOR FRAME#2 TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. I ' SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 11 FT 1 IN i I i ALDRICH RESIDENCE 230 BANYAN DRIVE DOOR REPLACEMENT PLAN PORT ST. LUCIE, FLORIDA ' I i ' I