Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online 6/19/17,7:01 AM rg- SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map ( Links Search j :da rrr���i►►► .figNiproduct Approvai USER:Public User -prOnar; •.P '@l_4:n�i.>yLqdy4;oric�,t;jgD:2 :h%Aoulicatlon List>Application Detail FL#_ _ F1-10674-R12 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived '• Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature. Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY COPY Toledo,OH 43659 (419) 376-8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed_ Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich,PE r} Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R12 COI 2016 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Btandard Year https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEA65bxB8ctyag%3d%3d Page 1 of 2 Florida Building Code Online 6/19/17,7.01 AM r ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 Summary of products EL# Model,Number or Name Description 10674.1 Owens Corning.Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No. FL10674 R12 II 2016 04 'FINAL ER OC ASPHALT Approved for.use outside HVHZ:Yes SHINGLES FL10674-R12.Ddf Impact Resistant: N/A Verified By: Robert J. M.Nieminen PE-59166 Design pressure:: N/A Created by Independent Third Party:Yes Other: Refer to ER,Section 5. Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-1112.pdf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,emailaddresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 4SS,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click hue. Product Approval Accepts: Sam ® ® A https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEA65bxB8ctyag%3d%3d Page 2 of 2 ..... EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization!#9503 Tc 353 CHRISTIAN STREET,UNIT#13 T OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT .Owens Corning Evaluation Report 037940.02.12-117 One Owens Corning.Parkway FL10674-R12 Toledo,OH 43659 Date of issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein.. DESCRIPTION: Owens Corning.Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this.Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E. if the product changes or the referenced Quality assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: 'The Evaivation Report number preceded by the words "Trinity l ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upan request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of.pages 1 through 8. Prepared by: ...i..4r'awnrwr!- • .�..��..Z�:.s�o-3g1A'Sl;✓ Robert J.M.Nieminen,P.E. +� ��r�+3;�,;:,;;,,5_s,J, The facsimile seal appearing was authorized by Robert Nieminen, i.,}aW`?hF� ��sss•> P.E.on 04/18/2016.This does not serve as an electronically signed Florida Registration M0.59.166,Florida DCA ANE2983 document.Signed,sealed hardcopies have been transmitted to the Product Approval Administmtorand to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3.. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Muminen, P.E.c.oes not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless,retained specifically for that purpose. 1 9 ' TYJ- ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section ProperW Standard Year 1507.2.5,12905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,11905.2.6.1 Wind Resistance: ASTM D7158 2008 3. REFERENCE;: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) 0hys1cals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(T.ST9623) Wind Resistance 11CA34308 02/18/2012' UL LLC(TSf9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LL::(T_Sl'91628) Physical Properties Classification.letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (O.UA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classics and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTm are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, Tru Definition* Durations, Duration* Premium Cool, Tru Definition* Duration* Designer Color Collection, Tru Definitions Oakridge, Oakridge* and WeatherGuards HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berksh're* Hip & Ridge.Shingles, High Ridge;WeatherGuard* HP Hip& Ridge Shingles, ProEdge Hip& Ridge Shingles and Dura Ridge'"AHip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Pius and Starter Shingle Roll arestarter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 'vire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authadzot+on Y9 503 FL10674-R12 Revision 7:04/18/2016 Page 2 of 8 TTY�E 5.4. Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles.are acceptable for use in all wind zones up to Vasa=150 mph (Vett=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,_Starter Strip Shingle and Starter Strip Plus noted herein are Classified. in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V,,,t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Uassiffcation by ASTM D7158 applies to exposure category B ort and a building height of 60 feet or less. Calculations by a qualified design professional are raquired for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the.Florida Building Cede and F.A.C.Rule 61G20-3.' 6. INSTALLATION: 6_1 Underlavment_ 6.1.1 tlnderlaynient shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6_2 A0, hali 5►i ales;. .6.2.1 Installaflon of asphalt shingles shall comply with the manufacturer's current published instructions, using Minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: 3= Berkshireo shingles require minimum five(5)nails per shingle. WeatherGuar.l®HP shin?les require minimum six,(6)nails per shingle. A Devonshire""shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners Szhail be in accordance with the manufacturer's published requirements, but not less than FBC 1507 2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope: exceeds .21 units vertical in 12 units horizontal, special methods of fastening are rcyuircd. See figuras belc-,v for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: a�MUR"fUMM.� Fa!r upd;'taYTes�,t -,,�•��_—uac SdkdbuW � Fee,�6ra+me � S&Vqdh WeadmLoW s. ilt r i 4 bcdod cdv :�:iis bcxtrd 7"—r tram eave Stri s ��'eYfttir�7 snlhesive i Inut8laetSfxrorStdpPlus p, r�;"T�yaaian0eave awlhti nmOred ewe Startar skic9?��jrzthh �\?I,,aj S f StuftrStrgtshinyfemesrhangyL.rimaWesksMMM '6' r! St+rbr F4sa maseadwtnst/i'a/t' l }. 1P�1]:if3::-'6'U'wiII9tl'ffl5_.eT9i/if![ER1:9i�A6Mat•I: t. FdfilQi�iRm' '1 Extedor Research and OEsiy,:. Evaluation Report 037940.02.12-0 Certijimte of Aurnoriroeian 7195c�_ FL10674-R12 Revision 7:04/18/2016 Page 3 of 8 QO -: ERD 6.2.6 . Minimum Nailing -Clas_icl'&Supi me: 4 NvrNml Msn"rd or per+ M4rAu1 M 00 An�para tNlRr7 reo lii tlt+�:ti, absvona�' WindAito ft"and iavirll�li�r .frrinit+ana.vloiiAaa rt amrePGe ittono vLantos ftwu& :. via tsar Jllsta fwiiEiK' - ,.... •. o.: o „� "� x s art 4P6a?�rrg4tr 'm c, w IMM 6.2.7 Ainrrrr�m Nailing—Berw.shire-: ' �GS:fb(:..:.�1�'dtT�Sr-isriN:e�4W:In:SLLe:T:Wt.GfrPSil,JiC'+IYn"TSe9tb/�lU., .i Smalantstrip 1 l; 1 v6.eea�O�v®�®Me�.n�r.2n>.�vmis!•:�u. ' �i ILa fm do seffadw 4. . ! e' If3GGYS - t 8 S2" 8 IJV" B 1Q" 8 Yz" f {j j I is Standa d rastening Pattern 6-Nail Fastening Pattern smart': i ,<;teLPad equadm: I. f 0[s?l;a�t6n}cemern f"u Qeo�ia¢atatiturieas(elto. ' Mansard or Steep Slope i-astening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate ofAutherizotion#9503 FL10674-R12 Revision 7:04/18/2016 Page 4 of 8 TY .ERS 6.2.8 Minimum Nailing-Devonshiren: 7° 1 8" 1. 8R �Ir 8" 7 Is .• : O •'y''q�\ 1 ISS 56/8°flHpOSnly C�osfddtldm6.6f8P+i19 Seatalltlocatiin •i '� '• UN !0A Alai i'I ys• 6t Ten 1*Spelsof RoafCemwit :;:andard 6-:Vail haste'ing Patterli Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Durations',TruDefinition® Ou-ation, Duration® Premium Cool&TruDefinitione Duration Designer Color Collection: •.4fi&�6Fedening;F'�itaia 6QIa11FesteiUng,Pasterrl. S(eali�!tsa¢rAaiva�e}�i .. 9�1�` Emil t o-. s va a � S Standard Fastening PaVi!rn 6-Nail Fastening Pattern Fauai�ingla Sl�ca'Gse '�r2t 72: ���+ �.1evFss.�ugs.(aar 174— Ma ns --Mansard or Steep Siopfa Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Ceriifltate of Authorization#9503 F110674-1112 Revision 7:04/18/2016 Page 5 of 8 11 � Ro 6.2.8 Minimum Nailing—Devonshire'"': ° 1+ 70 1+ 8° 1+ $p { 8° t 7 N ° . � ,�6818'exposure ,s b�osieE6n de 5.5,'8 pnlg Sealiurt leuahon Ten 1'- of aftRcdCemem sno ..,anoard 6-Vail F`aste,'!ng Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Duration®,TruDefinition® Ou-ation.' Duration® Premium Cool &TruDefin'ition*Duration* Designer Color I t; Collection: 4-Na1f Fastoning Palteer�. "FaSft";PaU9W MINIStandard Fastening Pattern 6-Nail Fastening Pattern Fa-tsr#igfor ato{ -- '.,iv+tJY{liS�idiipmwvl�ir ME t^ 1 •„:�m s . � F.AB:•-''-0a�f.:..�(f'�3FaWS0y.dlGlYtll . 114ansard or Steep Sop, Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 5 of 8 T 1T .4 ERD . .. 1. 6.2.1 Minimum Nailing—TruDefinition'Oakridge°,Oakridge®: . d;tJ�Sr 0. W,��gh 8518" droit :6;618"'E`�oeme. �Qia�dorr�&&/8�td¢• cl3isas �gncldan tfa i;3l�pukj.. Stand rd Fastening Patterr 6-Nail Fastening Pattern 'a J Mss ;>na i,sp:o a aupl:-R+turHep,Cimaet r;ansard Or Steep SIapP Fastening Pattern 6.2.1 Minimum Nailing—W(?atherGuard�HP: Exterior Research'and Design,U.C. Evaluation Report 037940.02.12-117 Cert tate of Authorizadon#9503 F110674-1112 Revision 7:04/18/2016 Page 6 of 8 ,M.f TY.ERD 6_3 Hip&Ridge Shingles_ 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge,WeatherGuarde HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle. Installation of DuraRidgel" Hip& Ridge Shingles shall comply with the manufacturer's current. published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fw.teners shall be in accordance with the manufacturer's published requirements, but not.less than FBC 1.507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing Berkshire"'-lip &Ridge and High Ridge: Mals ,4 I idp�erynata} t C l I 1: V It Sir— I g^ B. V 6.3.4 Minimum Nailing–WeatherGuard®HP Hip and Ridge: P17A9AtA lIYki .�', f .. • ll2- ' f L I t I 2 r f : i J IL , Exterior Research and Design,LI.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization 49503 FL10674-R12 Revision 7:04/18/2016 Page 7 of 8 Tj" ARD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Provaffing 6ftrAwd 1f' Wim Ir Etnaate.w 1-1h - 5y yk ii I s■ ■ M. Pri11A3d Expa"d 6.3.6 Minimum Nailing—DuraRidgeT"Hip g Note:The drawings t; iow pertain to frunimum,a t.!sted attachment requirements. Refer to Owens Corning published ins:illation ins-tru tion5 for their-minim in:requirements. am 7. LABELING: 7.1 Labeling steal! b•� in accordance "";ith the requirer:ients the Accredited Quality Assurance Agency noted herein. 7.2 Aspha t shingle wrappors shail indicaL., compliarce with one of the required classifications detailed in FBC Table L507.2.7.1/P.90L 2.6.1. 8.' BUILDING PERMIT k EK jUkRElV1FN YS•: As required by the Building Oficial or Auld ority Having Juriiidiction in order to properly evaluate the installation of this product. 9. MANUFACTURIMG PLANTS: Contact the mored QA ent ty of Inru:ma-io: on which :)kr,ts produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITYA'SSURAWC`i",V l-e UL LLC—QUA9G25; ul.:o:n ERD OF EVALUATION REPORT- Exterior Research anti DaAgn,3 I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 8 of 8