Loading...
HomeMy WebLinkAboutProduct Approval Florida.Building Code Online Page I of 2 T will lltii6�JYAt ' SCIS Home I Log In I user Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications I FBC Staff I BCIS Site Map I Links I Search Florida 1 I'L� �I Product Approvals 1 r �a USER:Public User p:p .ccis � 6%1:K..Y.YI:RtV W ProdUCC Approval Menv>Product or Application Searches Aoolicatlon Lis[>Application Detail i Cr FL# FL16048-R4 Application'.Type Revision Code Version' 2014 Application Status Approved Comments v� Archived ❑ Product Manufacturer Tri-Built Materials Group,LLC Address/Phone/Email, PO Box 70 RECEIVED Rutherford,NJ 07070 (800)516-1485 david.ruiz@tribuiltmg.com OCT 16 2017 Authorized Signature David Ruiz PER.MMING david.ruiz@tribuiltmg.co p e ` 0 Tiechnicall Representative David Ruiz gyp+L ` till Address/Phone/Ermail! 250 Route 17 North LL-18 East Rutherford,NJ 07073 (20I)842-2449 david.ruiz@tribuiltmaterialsgroup.com Quality Assurance Representative Address/Phone/Email) ° Category Roofing Subcategory Underlayments Compliance'Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida'LicensePE-59166 Quality Assurance'Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W.Knezevich,PE (-1 Validation Checklist-Hardcopy Received Certificate of Independence FL16048 R4 COI 2016 01 COI Nieminen.odf Referenced'Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM G155 2005 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995 Equivalence of Product Standards Certified!By Sections from the Code http.//www.floridlabuuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr... 1/26/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date•Subm ittedi 10/06/2016 Date Validated10/17/2016 Date Pending FBC Approval 10/19/2016 Date Approved' 12/13/2016 Summary of Products FL# Model,Number or Name Description 16048,.1 TRI-BUILT Roof Underlayments Seif-adhering,modified bitumen roof underlayments 'Limits of Use Installation Instructions Approved for use in HVHZ:No: FL16048 R4 11 2016 10 FINAL ER TRI- Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R4.pdf Impact Resistant:N/A Verified By:Robert Nieminen PE 59166 Design Pressure:+N/A/'-67.5 Created by Independent Third Party:Yes Other.1..)The design..pressure noted herein pertains to use Evaluation Reports of foam-on,tile systems overtop the self-adhering. FL16048 R4 AE 2016 30 FINAL ER TRI- underlayment for one particular application.See ER Section BUILT UNDERLAYMENTS FL16048-R4.pdf 5.6.4 for details.2.)Refer to ER Section 5 for other Limits of Created by Independent Third Party:Yes Use. Back Next Contact Us::2601 Blair Stone Road,Tallahassee F1,32399 Phone:850-487.1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida.law,emailaddresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail,to this entity.Instead-,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal;atldress,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S„please click here. Product Approval Accepts: =® I Pti M Credit Card Safe httpi-//www.floridabuildinig.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr... 1/26/2017 EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization 119503 TRINITY I ERD 353 CHRISTIAN STREET, UNIT#13 OXFORD,CT 06478 PHONE:(203) 262-9245 FAX:(203) 262-9243 EVALUATION REPORT Allied Building,Products Corp. Evaluation Report A42960_10.12-114 dba'TRP-BUILT Roofing Products FI-16048-114 90501 Louisiana:Street Date of Issuance:10/25/2012 MlerrillWilll'ei IN 46410, Revision 4: 10/06/2016 SCOPE:. This,Evalluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, R.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTCOW TRI'-BUILT Roof Underlayments LABELING; Labelling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.. CONTINUED COMPLIANCE:TMs Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation,changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation) Report by the named. client constitutes agreement to notify Robert Nieminen, P.E. if the product changes;or the,referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative!to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising,literature.. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION':U'poni request,a copy of this entire Evaluation Report shall•be provided to the user by the manufacturer or Its;distributors:and shallbe available for inspection at the job site at the request of the Building Official. This,Evaluation Report consists of pages 1 through 5. Prepared',by: e � 3�L !tu �r��S 'C'�-'` The facsimile seal appearing was authorized by Robert Nleminen, Robertl.M'.Nlemineny P.E. ` ''vi,:°`�; `` P.E.on10/06/2016,This does not serve as an electronkally signed Florida,Registration No,.59166;Florida DCA ANE1993 document.signed,sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION'OF INDEPENDENCE: 1.. TrinitylERDI doesnot have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products•it evaluates. 2'.. TrirlitylERD is,mot owned,,operated or controlled by any company manufacturing or distributing products it evaluates. 3.. Robert Nieminen,R.E.does,not have nor will acquire,a financial interest in any company manufacturing or distributing products for whichi the evaluation reports are being.issued. 4. Robert Nieminemy R.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product:. 5.. This isa!building code evaluation. Neither Trinityl ERD nor Robert Nieminen,P.E.are,In any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,Is/was used for permitting or design guidance unless retained specifically for that purpose.. �,�TRINITYJERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance:Statement: TRI-BUILT Roof Underlayments,as produced by TRI-BUILT,have demonstrated compliance withi the foll'owing sections of the F1'or'ida Building Code through testing in accordance with the following Standards. Compliance is subject to,the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2'.4,1507.2.8,.1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.5.3,15 07.7.3 1504.6 Accelerated Weathering ASTM G155 2005 1507.3.3• Installation Practice FRSA/TRI April 2012(04-12) 2012 152316.5.21 Physical Properties TAS 103 1995 3. REFERENCES: Entity. Examination Reference Date ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD(TST604% Physical Properties 540540.11.13 11/19/2013 ERD(,TST6049) Physical Properties S40540.03.14 03/26/2014 ERD'(TST604% Physical Properties 544870.04.14-2 04/02/2014 E R D(TST 6 049)1, Physical Properties S44870.04.14-3 04/02/2014 ERD((LST6049); Physical Properties 544870.04.14-1 04/10/2014 ERD((f5T6049) Physical Properties 544870.04.14-4 04/10/2014 ERD(TiST60'4%, Physical Properties 543530.02.14-1-R1 05/14/2014 ERD(TST60491 Physical Properties 543530.05.14 05/28/2014 ERD((FST6049), Physical Properties 540540.10.14 10/31/2014 ERD(TST6049), Physical Properties SC7645.02.15 02/13/2015 E RD,(TST 6049) Accel'eratedWeathering SC8520.04.15 05/27/2015 UL„LLC.(;QUA9625f Quality Control Multiple-Listing R16814 09/04/2015 Ut,LLC.(QUA9625)i Quality Control Service Confirmation Exp.10/16/2017 4., PRODWGT'DESCRIPTION: 4.1 Self-Adhering:Underlayments: 4.1.1 Tri-Built Sand''-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof und'erlayment,with a 36-inch sheet width. 4.:1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof und'erlayment 4'.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof und'eriayment. S. LIMITATIONS'. 5..1 This is a building code evacuation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research,and Design,U.C. Evaluation Report A42960.10.12-R4 Certificate of,Authorization,#9503 FBC NON-HVHZ EVALUATION FL36048-114 Revision 4:20/06/2016 Page 2 of 5 TRINITY I ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product 'is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval!based on this evaluation combined with supporting data for the prepared roof covering. 5,L All'owable roof covers appliedatop the underfayments are as follows: ;TABLE 1:tROOF'COVE R,OP,TIONS. Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R'SA Shingle yes No No No Yes Yes Underlayment Tri-Built S/A HTTU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 TriiwBullt Smooth HTS/A. Underlayment Yes No No Yes Yes Yes 5.5.1 "Foam-On Tile" Is:limited to use of the following Approved tile adhesives unless tensile adhesion/ long terror aging data from an accredited testing laboratory is provided. ➢ Tri-Built S/A HT TU Underlayment with 3M` 2-Component Roof Tile Adhesive AH-160 (FL6332) or Dow TleBond'"Roof Tile Adhesive(FL717) 5.6 Allowable substratesare noted below: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood,,ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed'Southern Yellow Pine;ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires tongue-and-groove board decking be covered with plywood or 0513 prior to installation of the self-ad'hering und'erfayment. 5,.6..2 BondAo-Insulation: Tri=Buift Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Trl-Built Smooth HT S/A Underlayment applFed to: Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam—on tike systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional.and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. 5.63 Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type t or It felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only),base layer shalli be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). Exterior Research!and Design,LLC: Evaluation Report A42960.10.12-R4 Certificate ofAuthorizatiorn#9503 FBC NON-HVHZ EVALUATION FL16048-R4 Revision 4:10/06/2016 Page 3 of 5 TRINITY I ERD 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not ad'd'ress wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5•.6.4.1 Maximum,Design Pressure=-45.0 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional,)ASTM D41 Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf. Deck: Structural concreteto meet project requirements to satisfaction of AHJ. Primer: Soprema Elastocol 600c Underlayment. Tri-Built S/A HT TU Underlayment,self-adhered. 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck:. Min.1913,2-,inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1) andtin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.7' Exposure Limitations. 5.7.1 Tri-Built.Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation 5.7.2 Tri-Built S/A HTTU Underlayment shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION': &1 TRi-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6•.2 Re-fasten,any,loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri-Built Sand-R.SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 63.1 Shall, be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of preparedroof covering,to be installed. 6.3.2' Non-Tife•ap.plications: White priming is optlonai,TRI-BUILT recommends priming the deck.if the final roof cover is not slated for install'ationwthin 24 hours. Apply sheet parallel,to the roof edge. Roll,out approximately 10 ft of membrane and peel back the first 3 ft of rel'ease,f3m. Adhere the exposed!part to the substrate and unroll the remaining membrane as far as possible. Once;the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll',broom or hand-press the membrane into place to achieve a bond. Horizontall seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches andl staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with TRC-BUILT requirements. Exterior Research and Design,LLC'. Evaluation Report A42960.10.12-R4 certl[hate oj,Authorl adon#9503: FBC NON-HVHZ EVALUATION FL16048-114 Revision 4:10/06/2016 Page 4 of 5 TRINITY I ERD When installing at slopes above 8:12,TRI-BUILT recommends back-nailing in the overlap area at-the top of the sheet at 12-inch o.c. For Valleys and Ridges-. Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3,3 Tile Applications(Tri-Built S/A HTTU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on the applications,reference is made to Section 5.6.4 herein for wind resistance limitations that fall'outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underl'ayment. 7. BUILDING PERMIT REQUIREMENTS: As,required by the Building Official'or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8'. MANUFACTURING PLANTS: Contact the noted QA.agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC.—QUA9626;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R4 Certificate of AutharizoUon#9503 FBC NON-HVHZ EVALUATION F1.16048-114 Revision 4:10/06/2016 Page 5 of 5