HomeMy WebLinkAboutProduct Approval (2) • Florida.Building Code Online Page 1 of 2
lit
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search
db'
Product Approval
r USER!Public User,
Product Annroval Menu>Preducl or Annlicalion Search>Annlicalion List>Application Detail C V l 1
-- - \ �
FL# FL18355-R3 A
Application Revision Type �
Code Version S 2014
Application:Status Validated
Comments
RECEIVEDArchived Archivedl-�
Product Manufacturer TAMKO Building Products,Inc. OCT 1. 6 2W
Address/Phone/Emaili PO Box 1404
Joplin,Mo 64802 PERMITTING
(417)624-6644 Ext 2305
kerri_eden@tamko.com St. Lucie County,FL
Authorized!Signature Kerr!Eden
kerri_eden@tamko.com
Technical Representative 4SWE 12" -4�0 Py
Address/Phone/Email: Im I L
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
f l Evaluation Report-Hardcopy Received
Florida!Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida,License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration,Date 01/07/2019
Validated,By Locke Bowden
(1 Validation Checklist-Hardcopy Received
Certificate of Independence FL18355 R3 COI TBP15001.3 FBC 2014 Product Evaluation Report
Shinnles.odf
ReferencedStandard and Year(of Standard) Standard Year
ASTM D 3161 2009
ASTM D 3462 2009
ASTMD D 7158 2008
TAS 100 1995
Equivalence of Product Standards
Certified'By
Sectionsfrom the Code
15Nbps:Hflloridalbuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquvosrHazGXQW83... 5/10/2017
Florida,Building Code Online Page 2 of 2
Product Approvall Method Method I Option D
Date Submitted 05/09/2017
Date Validated, 05/10/2017
Summar y of Products
FL# Model,Number or Name Description
18355.1 Glass-Sea],Elite Glass-Sea], ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage,Heritage Premium,
Heritage Woodgate,Heritage
Vintage,Hip and Ridge,and
Vintage Hip and Ridge Shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ:Yes FL18355 R3 II TBP15001.3 FBC 2014 Product Evaluation
Approved for use outside HVHZ:Yes Bepq_rt 5hingles.Ldf
I Impact:Resistant:N/A. Verified By:Zachary R.Priest PE-74021
I Design Pressure:N/A
Created by Independent Third Party:Yes
Other:See evaluation report for limits of use.
Evaluation Reports
FL18355 R3 AE TBP15001.3 FBC 20,14.Product EvDIU,1tiOn
Rep_qrt Shinclies.od
I Created by Independent Third Party:Yes
Oatk Next
Contact Us::2601 Blair Stone Road,Tlliiiihagae FI,32399 RhQag;E50-487-182
The State of Florida is an ANEW employer.Clipyrtght 2007-2013 State of Florida.::Privacy Statement::Ai;ciiujDjIity statement:;EpEvol 51atement
Under Florida law,email addresses are public records.It you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida,Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The emalls provided maybe used"for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine ff you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts.-
Z]�LE-1—T�j=
Credit Card
Safe
ann dt1_a-,nx?naram=WGEVX OwtDouvosrHazGXOW83... 5/10/2017
y ,
Application Instructions for
TAMKO HERITAGE@ 30
BUILDING PRODUCTS .1,11NATED ASPHALT SHINGLES
Dallas, TX • Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO
THESE ARE THE.MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING
FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN'COLD WEATHER(BELOW 409F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles.
1.ROOF DECK S.FASTENERS
These shingles are forapplicationtoroofdeckscapable ofreceiving WIND CAUTION: Extreme wind velocities can damage these
and!retaining!fasteners,and to,inclines of not less than 2-in.per foot. shingles after application when proper sealing of the shingles
For roofs,having,pitches in.perfoot to less than in.perfoot,refer does not occur.This can especially be a problem if the shingles
to special;insiructionstitled"LowSlopeApplication".Shinglesmust are applied in cooler months or in areas on the roof that do;not
be applied;properly.TAMKO assumes no responsibility for leaks or receive direct,sunlight.These conditions may impede the sealing
defects resulting from improper application,or failure to properly of the adhesive strips on the shingles.The inability to seal down
prepare the:surface to be roofed over. may be compounded by prolonged cold weather conditions and/
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the-shingles is
d ,and free from warped surfaces.It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized
drip,edges, f installed at eaves and rakes. dabs of TAM-PRO®Premium SBS Adhesive or TAMKO Tam-Seal
Adhesive on the back of the shingle 1 in.(25mm)and 13 in.(330mm)
PLYWOOD:All!plywood shalli be exterior grade as defined by the In from each side and 1 in. (25mm) up from the bottom of the
Engineered Wood Association.Plywood shall be a minimum of 3/8 shingle.Press shingle firmly into the adhesive.For maximum wind
in.thicknessandapplied in accordance with the recommendations resistance along rakes,cement shingles to the underlayment and
of the Engineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO SBS Adhesive or
SHEATHING.BOARDS:Boards shall be well-seasoned tongue- TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin uniform
and-groove boards and not over 6 in.nominal width.Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts
be a 1i in_nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in
spaced'and nailed. certain underlayments resulting in the asphalt flowing,dripping and
staining.Shingles must also be fastened according to the fastening
Z.VENTILATION instructions described below.
Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to the performance
moisture In winter months and a build up of heat in the summer. of the shingle. If the fasteners are not placed as shown in the
These conditions can lead to: diagram and described below,this will result in the termination of
TAMKO's liabilities under the limited warranty.TAMKO will not be
1i..Vapor Condensationn responsible for damage to shingles caused by winds in excess of
2'.Buckling,of shingles due to deck movement. the applicable mph as stated in the limited warranty.See limited
warranty for details.
3.Rotting of wood members.
FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from
4!.Premature failure of roof. the bottom edge of the shingle,penetrating through the common
To-insure adequate ventilation,and circulation of air,place louvers bond,and located horizontally as follows:
of sufficient size high in the gable ends and/or install continuous 1)Standard Fastening Pattern.(For use on decks with slopes 2 in.
ridge•and[soffit vents.FHA.minimum property standards require per foot to 21 In.per foot.)One fastener 1 in.back from each end
one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back from each end of the shingle for a total of d
of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below).
vapor barrier is installed on the warm side of the ceiling or if at least
one half oftheventilationisprovided near the ridge.Ifthe ventilation STANDARD FASTENING PATTERN
openings are screened,the total,area should be doubled. FASTENERS NAIL ZONE
COMMON
BOND
I_S PART[CtZLA�Ly�t.QORT�1 VLT TOOVIDE_
ADEQUATE VENTILATION, i[I
EXPOSURE5 5/8"
�f I_ L
VL► f— 12-1/2--+—12-3/8"—+— 12-1/2"-- h--1"
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11109
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1
e
o (CONTINUED from page 1)
TAMKO HERITAGE® 30
BU16DING PRODUCTS 6A1,1INATED ASPHA6T SHING6ES
Dallas, TX • Tuscaloosa, AL a Phillipsburg, KS • Joplin, MO
2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in. for new construction and 1-1/2 in.for
greater than2l in.per foot.)One fastener 1 in,back from each end reroofing thus allowing a minimum deck penetration of 3/4 in.The
andone fastener 8'-1/2 in.back from each end and`one fastener 16 crown of the staple must be parallel to the length of the shingle.
in,back from each end for a total of 6 fasteners per shingle.(See The staple crown should be driven flush with the shingle surface.
Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered
MANSARD AND HIGH WIND FASTENING PATTERN improperly applied.
FASTENERS NAIL ZONE Properly Driven Improperly Driven
COMMON enr undardriven overdriven crooked
BOND H
Asphalt
.--.Shingles
6-IM .I f EXPOSURE 5-50' ,� �t Decking
9
>�.( ��irz�+l:-�-�rz•`►�-�-mss^-�-7-rrz•+N-�-�rz^-►► l.-r �'rr mla.
3)High Wind Fastening Pattern. (For High Wind Application CAUTION:ALL FASTENERS MUST BE DRIVEN INTO THE NAIL
requirememtsp One fastener T in.back from each end.One fastener ZONE/COMMON BOND AS SHOWN IN THE DIAGRAM ABOVE.
8'4/2in,back fromi each end and one fastener 16In.back from each 4.UNDERi6AYMENT
emdfora.total'of six(6)fasteners,per shingle.ln addition to this shingle
fastening pattern requirement for High Wind Application,TAMKO UNDERLAYMENT:An underlayment consisting of asphalt saturated
also requires the use of the following TAMKO products:TAMKO felt must be applied over the entire deck before the installation of
felts or und'erlayments;,TAMKO Moisture Guard Plus underlayment TAMKO shingles.Failure to add underlayment can cause premature
at all!eaves,rakes,and valleys;.TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited
coatings products where required,-.TAMKOventilation where required, warranty.Apply the felt when the deck is dry.On roof decks 4 in.
TAMKO,starter shingles if available in area,and TAMKO Hip and Ridge per foot and greater apply the felt parallel to the eaves lapping each
shingles imstall'ed on alt hips and ridges-Along rakes,cement shingles course of the felt over the lower course at least 2 in.Where ends
to,theunderlaymentand each other Ina4in.(402'mm)width ofTAM- join, lap the felt 4 in. If left exposed, the underlayment felt may
PROS SBS Adhesive or TAMKO Tam-Sear Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of the
building codes for proper nailing application.High Wind Application undedayment and the shingle application must be done together.
isofferedionnew construction or complete tear-off applications only. Products which are acceptable for use as underlayment are:
It is.not offered'for recover applications.If High Wind Application
requirements are not followed,the High Wind'Application Warranty - TAMKO No.15 Asphalt Saturated Organic Felt
MPH,as stated on Table 1'in the Limited Warranty,reverts to the - A Leon-perforated asphalt saturated organic felt which meets
Standard Application,Wind'Warranty MPH limit.(See Mansard and ASTM:D226,Type i or ASTM D4869,Type I
High,Wind!Fastening Pattern illustrated above.) - Any TAMKO non-perforated asphalt saturated organic felt
- TAMKO TW Metal'and Tile Underlayment,TW Underlayment
NAILS:TAMKOrecommends the use of nails as the preferred method and Moisture Guard Pluse(additional ventilation may be
of application_Standard'type roofing nails should be used. Nail required.Contact TAMKO's Technical Services Department
shanks should be made of minimum 12 gauge wire,and a minimum for more information.)
head;diameter of 3/8.in.Nails should be long enough to penetrate
314 im into-the roof,deck.Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water
the nails should be long enough to penetrate completely through from frozen or clogged gutters is a potential problem, TAMKO's
plywooddecking and extend;at least 1/8 in.through the roof deck. Moisture Guard Plus®waterproofing underlayment(or any specialty
Drive:nails head flush withi the shingle surface. eaves flashing product) may be applied to eaves, rakes, ridges,
valleys, around chimneys, skylights or dormers to help prevent
Prep dVOd"an unprapady Dd"an water damage.Contact TAMKO's Technical Services Department
—mlmdlameter undaMdsen overdri"an crooked for more information.
�_Asphalt
_ _ Wag!ea TAMKO does not recommend the use of any substitute products
E --Docking as shingle underlayment.
�1 —.0l,
Inadequate S.APPi61CATION INSTRUCTIONS
atrolght,goodponatrstlon; Insdaqusla toodeep,cuts eQ
and9lush.with shingle surface- penetnrgon InlasMngle anaharego STARTER COURSE:A starter cou rse may consist of TAMKO Shingle
Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral
STAPLES.Iff staples are used in the attaching process,follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove
above instructions for placement.All staples must be driven with the exposed tab portion and install with the factory applied adhesive
pneumatic staplers.The staple must meet the following minimum adjacent to the eaves.Attach the starter course with approved
dimensional'requirements.Staples must be made from a minimum fasteners along a line parallel to and 3 in.to 4 in.above the eaves
16 gauge galvanized wire-Crown width must be at least 15/16 in. edge.The starter course should overhang both the eaves and rake
(staple.crownrwidth is measured outsidethe legs),.Leg length should edges 1/4 in.to 3/8 in.
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site at Northeast District 4500 Temko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2
o (CONTINUED from page 2)
TAMKO HERITAGE" 30
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Dallas,TX • Tuscaloosa,AL • Phillipsburg, KS • Joplin, MO
SHINGLE APPLICATION:Start the first course with a full size shingle 6.LOW SLOPE APPLICATION
and,overhang!the rake edge 1/4 in.Cut 10-3/8 in.from a full shingle On pitches2 In.per foot to 4 in.per foot cover the deck with two layers
to form ash lngl;e 29 in:long.Use this to start the second course(see of asphalt saturated felt.Begin by applying the felt in a 19 in.wide strip
diagram:below).Cut a 23in.1ongshingle to start the third course.Use along the eaves and,overhanging the drip edge by 1/4 to 3/4 in.Place
the remaining.1B-3/&in.piece of shingle to start the fourth course and a full 36 in.wide sheet over the 19 in.wide starter piece,completely
use the remaining 10-3/8 in,-piece to begin the fifth course.Continue overlapping It.Al succeeding courses will be positioned to overlap the
up,the rake in as many rows as necessary using the same formula preceding course by 19 in.If winter temperatures average 25aF or less,
as outlined above.The butt of the shingle should be aligned-with thoroughly cement the felts to each other with TAM-PRO or TAMKO
thetop edge of the sawtooth of the underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of a least 24 in.
exposure(see shingle application drawing illustrated on this panel). inside the interior wall line of the building.As an alternative,TAMKO's
Whenlyou make your final'cut at the roof's edge,flip any pieces that Moisture Guard Plus®self-adhering waterproofing underlayment may
are 8:in..or.longer back onto the roof.These pieces can.be worked be used in lieu of the cemented felts.
in anywhere without creating zippers or color variations.
NOTE:Do not align working In of shingle courses when workinin cut �•MANSARD ROOF OR STEEP SLOPE ROOF
pieces..Joints should be no closer than 4,1n.from,one another If the slope exceeds 21 in.per foot(60),each shingle must be sealed with
TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately
upon installation.Spots of cement must be equivalentin size to a$.25
piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners
10-31V per shingle.See Section 3 for the Mansard Fastening Pattern.
8.RE-ROOFING
coats 9. !;1s-31etQ 3�8 ° y _ ", 29 Before re-roofing,be certain to inspect the roof decks.All plywood
23at n u'; shall meet the requirements listed in Section 1.
Nail down or remove curled or broken shingles from the existing
29 16-0 20.': roof.Replace all missing shingles with new ones to provide a smooth
rake Full! base.Shingles that are buckled usually indicate warped decking
10 ala^ or protruding nails. Hammer down all protruding nails or remove
' them and refasten in a new location. Remove all drip edge metal
51hwune .16.36" and replace with new.
41h�course 16.3/6
If re-roofing over an existing roof where new flashing is required
O
3rdlcoune 23" ,�' �'°'�'' to protect against Ice dams(freeze/thaw cycle of water and/or the
kfx 2s i backup of water in frozen or clogged gutters),remove the old roofing
to a point at least 24 in. beyond the interior wall line and apply
Ist Course F I 10.3/6" TAMKO's Moisture Guard Plus'°waterproofing underlayment.Contact
says TAMKO's Technical Services Department for more information.
Measurements will vary when nesting over an existing 5 in.exposure
single roof:Call TAMKO Technical Services for further information.
Cut your g,stcourw ddngle to make 29'and a 10 319'
1-1nge.ora.ascend pl K1fl W make.23•ane The nesting procedure described below is the preferred method for
a 16 319'length:
n39' reroofing over existing metric size shingles with a 5-5/8 in.exposure.
See description below:
Starter Course:Remove the tabs and an additional portion from the
4.23'
„ head of a full size shingle so that its height is equal to the exposure
of the existing shingles.Position the resulting strip over the existing
roof edge(with the factory-applied adhesive strip along the eaves).
Cut approximately 6 in.from the rake end and apply the remaining
portion at the eaves.Continue the starter strip by applying full length
shingle strips cut to height as above,evenly along the existing roof
at the eaves.The existing roof should overhang the eaves far
2„���1�2,•;2;a 1,1111;o°318 enough to carry water off into the gutter.If this is not the case,
englh4
nak'eUCa”u'...° 'n`"g"9with NDn a
meka live wwsos. cut and apply the starter strip so that it will provide sufficient
overhang for proper drainage.
3Conlinuatthe yavwa,acrosslh.roefWhen mtareyuu longer r First Course:Remove an amount from the butt edge of a full-size
.9np1 cut 0.1 no roofs odga,flip any places that are u lager g
bark..to the.0.The.yowl can be worked In eny,A,c,ewiln.W shingle so that the remaining portion of the shingle fits between the
R png lipr—nr nitlr ran.11—
NOTE:
.11 .NOTE:Dant ellgalalnta otstdnitleco—when working In butts of the existing third course.This course must also be applied
out plocoe.M.ta ahould'be no closer than 4'from on....ther.
evenly along the eaves edge of the new starter strip.
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver;CO 80216 800-530-8868 3
(CONTINUED from page 3)
ffTA:MK01HERITAGE® 30
BUILDING PRODUCTS LANINATED ASPHALT SHINGLES
Dallas, TX •Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO
Second and Succeeding Courses: Remove 10-3/8 in.from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
rake end of the first shingle in the second,course, and continue CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT.
withi fulll width shingles for the remainder of the course, placing.
the top edge of each new'shingle against the butt edge of the ofd veiley centerline
Mnim , wide sheat
shingle in the course above:This method should create an exposure of'J.4Guard Fast,r50rb.e
Plusof 5-5/8.in.after the first course.When beginning the succeeding o healer orroufaq ! end traWtrgla
courses continue to follow the Heritage application instructions. xtend end shk le
12--t 8-beyond
(Seelsection 5). ,. v.R.V O.nt0d`ne
Existing shi- ngle � i
i UlMmlayment No fastenerswithin
�C ` �5 5/8% / 6•offcenterfter[ne
Drip'edge
\'., � the vt tip of shlrgta on the cribs of
the venkel sNnglo,2 inches back,
Drip edge nom valWy rxnte�ne and eoverlrg
the vedkal Wngle.
New shingles
5.5/8' -55/8°exposure ID.RIP AND RIDGE FASTENING DETAIL
exposure Apply the shingles with a 5 in.exposure beginning at the bottom
T of the hip or from the end of the ridge opposite the direction of the
9.VALLEYAPP6ICATIDN prevailing winds.Secure each shingle with one fastener on each side,
5-1/2 in.back from the exposed end and 1 in.up from the edge.
Over the;shingle underlayment,center a minimum 36 in.wide sheet TAMKO recommends the use of TAMKO Hip & Ridge shingle
of TAMKOINaiI-Fast®,Moisture Guard Plusa or a minimum 50 lb.roll products.Where matching colors are available,it is acceptable to
roofing in the valley Nail!the felt only where necessary to hold it in use TAMKO's Elite Glass-Seat shingles cut down to 12 in.pieces.
place and'then only nail the outside edges.
T:PRIOR.TO INSTALLATION'WARM;SHINGLES TO Fasteners should be 1/4 in.longer than the one used for shingles
IMPORTAN
PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT PRIOR TO INSTALLATION, CARE NEEDS TO BE
SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
After valley,flashing is in place:: BENDING SHINGLE IN COLD WEATHER.
• Apply the first course of shingles along the eaves of one of the Direction of prevailing wind
intersecting:roof planes and across the valley. start 5e exposure
Note.Forproperflow ofwater overthetrimmed shingle,always here—
..
ere` — to
starti applying-the shingles on the roof plane that has the lower
";?
astener
slope.or less height. l� /z°
• Extend;the:end shingle at least 112 in.onto the adjoining roof. l II start
inextendingthem hereo—
Apply'succeedingcourses ^exposure
across.the valley ands onto,the adjoining roof.
• Presstheshinglestightly Into,the valley. THESE ARE THE MANUFACTURER'S APPLICATION
•
Use monmaPshinglefastening methods. INSTRUCTIONS FOR THE ROOFING CONDITIONS
DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES
Note.Nafastemershouldbewithin 6imofthe valley centerline, NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
and!two,fasteners.should be placed at the end of each shingle DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
crossing;the valley. MANUFACTURER'S INSTRUCTIONS.
• Tothe adjoiningi roof plane,apply one row of shingles vertically
facing the valley and 21n.back from the valley centerline.
Note: For a neater installation,snap a chalkline over the TAMKO®,Moisture Guard Plus®,Nail Fast®,TAM-PRO®and Horkage®are registered
l trademarks of TAMKO Building Products,Inc.
shingles for guidance. Information Included In these application instructions was current at time of printing.To
• To complete the,valleyy,apply shingles on the adjoining roof obtain a copy of the most current version of these application Instructions,visit us online
plane by positioning the tip of the first shingle of each row at at tamko.com or call us at 800-641-4691.
the 2 int.point fromthe centerline where the edge of the vertical
shingle has been applied,covering the vertical shingle.
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11109
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd.Ave., Denver,CO 80216 800-530-8868 4