HomeMy WebLinkAboutWind Load Calculation Property Information Building Information
Owner: Hoke Wind Zone: 160 MPH.
Address: 56 Flores del Norte Exposure Category: B
Ft Pierce,F134951 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 26 45 7 32.5 -35.2
2 Int 55 50 7 31.1 -33.9
3 Int 55 50 7 31.1 -33.9
4 End 105 62 7 29.3 -37.1
5 End 105 62 7 29.3 -37.1
6 Int 70 62 7 30.2 -32.9
7 Int 74 66 7 29.9 -32.7
8 Int 26 45 7 32.5. -35.2
9 Int 35 66 7 31.5 -34.2
10 Int 35 66 7 31.5 -34.2
11 Int 26 45 7 32.5 -35.2
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page I of 1
s