Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 Iff BCIS Home Log In 1 user Registration Hot Topic Submit Surcharge i Stats&Facts Publications 1 FBC Staff i BCIS Site Map Links Search Flodda �Product Approval �t L �'11014",USER:Public User Product Aooroval Menu>Product or Aoolication Search>Aoolication List>Application Detail FL# FL10947-R7 Application Type Editorial Change Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer ]ELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Kaede McLaughlin fbcl@jeld-wen.com Technical Representative ]ELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 202 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/22/2017 Date Validated 06/26/2017 Date Pending FBC Approval https://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgvihT9G9wJlk... 10/23/2017 Florida Building Code Online Page 2 of 2 Date Approved 06/29/2017 Date Revised 07/10/2017 Summary of Products FL# Model,Number or Name Description 10947.1 Builders Atlantic Aluminum Horizontal Slider(4200)73"x 49.625"Insulated Glass(1/8 in-1/8 out Annealed)or Single Glaze(3/16 in Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL10947 R7 C CAC NI011625-Ri.udf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 01/31/2026 Design Pressure:+50/-50 Installation Instructions Other: FL10947 R7 II XO DP 50 73x49 625 Installation Instructions Ddf Verified By: Hermes F.Norero, P.E.73778 Created by Independent Third Party:Yes Evaluation Reports FL10947 R7 AE PER3033.0f Created by Independent Third Party:Yes 10947.2 Builders Atlantic Aluminum Horizontal Slider(4200) 110"x 49.625"Insulated Glass(Sash 3/16 in- 3/16 out Annealed,Fixed 1/8 in-1/8 out Tempered)or Single Glaze (3/16 in Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL10947 R7 C CAC NIO11625 01-Rl.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 01/31/2026 Design Pressure: +50/-50 Installation Instructions Other: FL10947 R7 II XOX 110x49.625 DP 50 Installation Instructions.Ddf Verified By: Hermes F.Norero,P.E.73778 Created by Independent Third Party:Yes Evaluation Reports FL10947 R7 AE PER3034.Ddf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails prgyided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: i 0 Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvihT9G9wJlk... 10/23/2017 NOTICE OF PRODUCT CERTIFICATION �,��p CERTlRj�.4 NCCR- oy v . o"* CERTIFICATION NO: N1011625-R1 9 x ®x. DATE: 08/08/2013 N MI CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN AWN��.5�`` CODE: 1822-1 _ �Nc. D PREVISION DATE: 06/10/2017 F7ENp. . To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertitication.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN `Builders Aluminum Horizontal 3737 Lakeport Boulevard Sliding Window(4200)" Klamath Falls, OR 97601 w/Flange& Slip-On Nail Fin Configuration:XO Glazing:Monolithic(3/16"Annealed Glass)or Insulating Glass(Annealed Glass) Frame: W-1854mm(73") H-1261mm(49.63") Panel: W-933mm(36.75") H-1219mm(48") SPECIFICATION PRODUCT RATING TAS 202-94 Design Pressure: 2394 Pa (50 psf) Negative Design Pressure: 2394 Pa (50 psf) Water Penetration Resistance Test Pressure:359 Pa(7.5 psf) Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3656-5 Expiration Date: January 31, 2026 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 MASONRY \ W ° .° „ MM =T e Ur (NCTL 210-3656-5A) x x o m z 1 1/4• O 0 L%X —O MIN. in x v d EMBEDMENT 31/4 Ax HIM SPACE — / 1 1/4' MIN. EMBEDMENT-I�-I 3 1/4' MAX J taws SHIM }-—-A I �' SPACE. n " 14334 cna v 2 z X air D099 CORNING GLAZING DETAIL ~ Z o TYPICAL VERTICAL FRAME SECTI❑N I x = NOTEr Caulk between 11 0 o O unit and opening. 3X� DOW CORNING Z t9 z 346-- 1199 SILICONE � 3 0GUM JUM ur TYPICAL H❑RIZ❑NTAL FRAME SECTI❑N NOTE. Caulk between unit and opening, GLAZING DETAIL 1/4' MAX 'Q SHIM SPACE lv--- — 'M N• Max Frame DP IMPACT 6 J, ° o —O• 9 EMBEDMENT 1731,' x 49/a +5 0/-5 0 I No ° 3 WINDOW HEIGHT (49%' MAX.) � v• �ia¢ffir e,�: TYPICAL ELEVATI❑N WITH FASTENERS General Notes: • The product shown herein is designed, tested and manufactured to Installation Notes: comply with the wind load criteria of the adopted International Building 1. Seal flange/frame to substrate. Code (IBC), the International Residential Code (IRC), the Florida Building 2. Use 3/s'Tapcon fasteners through frame with sufficient length to Code'including the"High Velocity Hurricane Zone" (HVHZ) and the penetrate a minimum of 1 1/4" into the concrete (Min. fc = 3000 psi) industry standard requirements for the stated conditions. or masonry(Conforms to ASTM C90). • All glazing shall conform to ASTM E1300. 3. Host structure (wood buck, stud framing and opening)to be designed • Minimum nominal glazing: 3/s' monolithic or 1/8" insulated. and anchored to properly transfer all loads to the structure. The host • Installation methods may be interchanged within the same opening. structure is the responsibility of the architect or engineer of record for • An impact protective system is required where wind borne debris the project of installation. Digitally signed by Hermes F.Norero,P.E. . protection is required by local building code. I �I Reason:I am approving this document Maximum sizes are buck/net sizes and do not include firy % g s�1/., Date:2013.10.2413:06:19-04'00' This schedule addresses only the fasteners required to anchor the product to �� �j PROJECT ENGINEER: DATE: achieve the rated design pressure and impact performance(where applicable)up ���Q' •• • !Q� -- 02/25/2010 JELDVEN 3737 Lakeport Boulevard to the size limitations noted. It is not intended as a guide to the installation �� WN BY: SCALE: Klamath Falls,OR 97601 process and does not address the sealing consideration that may arise in different; ; �j 7TNTS (541)882-3451 C KEDD BY: BY: TITLE: wall conditions. For the complete installation procedure, see the instructions_ 7k _r packaged with the window or go to www.leld-wen.com/resources/installation. T/AT//T/s,TQ APPROVED BY: Builders Aluminum (4200) Horizontal Slider This drawing and its contents are confidential and are not to be reproduced or ��T• , '� ��� RT/PROJECT No.: Masonry Installation (73.00"x 49.625") copied in wholeIncor in part or used or disclosed to others except as authorized by ��i��9 LDi B,3"�a4�G�� �Q IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET FBPE i4 THDRIZA 171 MY44099 Venice Window Division BA4200 NCTL210-3656-A 01 1 of 4. 398 East Dania Beach Blvd. BUILDING DROPS Suite 338 A Perfect Solution in Every Drop Dania Beach, FL 33004 4 .. 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com ProdRct Evaluation Report Of JELD-WEN, inc. Builder's Aluminum Horizontal Slider Window (4200 Mechanically Fastened) for Florida Product Approval Report No. 3033 Current Florida Building Code Method: 1 —A (Certification) Category: Windows Sub — Category: Horizontal Slider Product: Builder's Aluminum Horizontal Slider Window (4200 Mechanically Fastened) Material: Aluminum 6063-T6 Product Dimensions: 73"x 50" Prepared For: JEL D-WEN, hic. 3737 Lakeport Blvd. Elamath Falls, OR. 97601 Prepared by: `�ES F. O '�1�1 liernies F. Norero, P.E. � �,� ••''• ' Florida Professional Engineer#73778 :• �'\'••• -. 0 Date: 07/23/2014 Contents: Evaluation Report Pages 1 —4T Installation Details Pages 5—6 O� (0 P `� Digitally signed by Hermes F.Norero, P.�iSS,••••••••'•••�C; � Reason:I am approving this document i�i��,'0N;; j%%NN Date:2014.08.14 14:53:19-04'00 Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop Date: 07/23/2014 - Certificate of Authorization:29578 Report No: 3033 Manufacturer: JELD-Wen, inc. Product Category: Windows Product Sub-Category: Horizontal Slider Compliance Method: State Product Approval Method (1)(a) Product Name: Builder's Aluminum Horizontal Slider Window(4200 Mechanically Fastened) (Non-Impact) 73"x 50" Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN,inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions BA4200_NCTL_210-3656-5,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the"High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does require an impact resistant covering. 4. Site conditions that deviate from the details of drawing BA4200_NCTL_210-3656-5 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions BA4200_NCTL_210-3656-5 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 6 BUILDING DROPS Date: 07/23/2014 A Perfect Solution in Every Drop - Certificate of Authorization:29578 Report No: 3033 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: QUA1789) Performance Standards: The product described herein has been tested per: • TAS 202-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratory, Inc. (FBC Organization# TST1589) Report#: NCTL-210-3656-5, Report Date: 1/22/2010 2. Quality Assurance National Accreditation and Management Institute (FBC Organization#: QUA1789) Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 6 BUILDING DROPS ' Date. 07/23/2014 ! A Perfect Solution in Every Drop Report No: 3033 Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates areas follows: Nailing Fin Installation: A. For two by(2X)wood frame substrate (Min.S.G. =0.55), use#8 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. Through Frame Installation: A. For two by(2X)wood frame substrate (Min.S.G. =0.55), use#10 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. B. For concrete (Min.f'c=3000 psi)or masonry(Conforms to ASTM C90) substrate where one by(1X), non-structural,wood bucking is employed, use 3/16"diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete (Min.f'c=3000 psi) or masonry(Conforms to ASTM C90) substrate where wood bucking is NOT employed, use 3/16"diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For steel substrate (Min 18 Ga., Fy=33 ksi), use#10 Tek Screw type steel frame anchors of sufficient length to achieve minimum embedment of 3 threads engagement into steel framing. Refer to Installation Instructions(BA4200_NCTL_210-3656-5)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Rating Positive 50 Negative 50 Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 6 BUILDING DROPS A Perfect Solution in Every Drop Date. 07/23/2014 Certificate of Authorization:29578 Report No: 3033 Installation Method JELD-WEN, inc. Builder's Aluminum Horizontal Slider Window (4200 Mechanically Fastened) (XO) Through Frame Installation 5" MAX. FROM HEAD .AMB TOP 8' 0.C. CORNERS MAX. s C� � V.C. s MAX. n co 3' FROM MEETING RAIL. WINDOW WIDTH (73" MAX.) XO or OX CONFIGURATIONS APPROVED Hermes F. Norero, P.E. Florida No. 73778 Page 5 of 6 BUILDING DROPS A Perfect Solution in Every Drop Date. 07/23/2014 Certificate of Authorization:29578 Report No: 3033 Installation Method JELD-WEN, inc. Builder's Aluminum Horizontal Slider Window (4200 Mechanically Fastened) (XO) Nail Fin Installation 5" MAX. TOP 153/4" 0.C. FROM MAX. CORNERS 13Y4" Z 0.C. o MAX. M b x WINDOW WIDTH (73" MAX.) XO or OX CONFIGURATIONS APPROVED Hermes F. Norero, P.E. Florida No.73778 Page 6 of 6 Hurricane opening protection® Hurricane shutters for replacement windows at 313 olive ave will be 1/2 cdx plywood and will comply w/Florida Building Codes 2001 edition and Florida Building Codes 2010-Residential edition: 2001 edition: a copy of page 16.5 section 1606.1.4 included in permit packet. Additional info and revised 2010 edition notes are as follows: (This section and table were dictated off the internet but not provided as copies in the permit packet) 8301.2.1.2 Protection of openings- reiterates that exception for 1/2 wood structural panels. Table 8301.2.1.2 Calls out fastner type and spacing for wood structural panels and is as follows: 1. Lag screws to be installed at opposing ends. 2. Fastners to be less than or equal to 1 inch from edges of panels 3. Fastners to be embedded into concrete block a minimum of 2 inches. 4. Fastners shall be located no less than.2.5 inches from the edge of block openings. S. Fastners shall be 1/4 inch lag screw and according to the chart(R301.2.1.2-not provided) be spaced no greater than 16" O.C. 6. Fastners shall be within 4 inches of every corner. 1606,1.3-TABLE 1606.1.4 1606.1.3 Anchorage against overturning, uplift and permitted for buildings with mean root'height of sliding. Structural members and systems, and compo- 33 feet(10 m) or less where wind speeds do not nents and cladding in a building or structure shall be exceed 130 mph (58 m/s). anchored to resist wind-induced overturning, uplift and sliding and to provide continuous load paths for these 1606.1.4.1 Buildings with openings. Where exterior a forces to the foundation.Where a portion of the resistance glazing is assumed to be an opening, in accordance with to these forces is provided by dead load, the minimum 1606.1.4, the building shall be evaluated to determine dead load likely to be in place during a design wind event whether the openings are of sufficient area to constitute an shall be used. open or partially enclosed building as defined in 1606.1.5. Open and partially enclosed buildings shall comply with 1606.1.4 Protection of openings. In windborne debris the applicable provisions of ASCE 7. 5 re-ions.exterior LIazing that receives positive pressure in 2 the lower 60 feet (18.3 m) in buildings shall be assumed 1606.1.4.2 The wind-borne debris regions requirements to be openings unless such glazing is impact resistant or shall not apply landward of the designated contour line in protected with an impact resistant covering meeting the Figure 1606.A geographical boundary that coincides with requirements of SSTD 12, ASTM E 1886 and ASTM E the contour line shall be established. _ 1996, or Miami-Dade PA 201, 202 and 203 referenced = therein as follows: 1606.1.5 Definitions. The following definitions apply 1. Glazed openings located within 30 feet (9.1 m) of only to the provisions of 1606. 5 grade shall meet the requirements of the Large - Missile Test. Building,Enclosed.A building that does not comply with 2. Glazed openings located more than 30 feet (9.1 rd) the requirements for open or partially enclosed buildings. above grade shall meet the provisions of the Small Building And Other Structure,Flexible. Slender build- Missile Test, ings and other structures that have a fundamental natural 3. Storage sheds that are not designed for human habi- frequency less than 1 Hz. 9 tation and that have a floor area of 720 square feet or ® less are not required to comply with the mandatory Building,Low-rise. Enclosed or partially enclosed build- ® w•indborne debris impact standards of this Code. ings which comply with the following conditions: a 1. mean roof height, h, less than or equal to 60 ft (18 5 Exception: Wood structural panels with a mini- m); _ mum thickness of 7/16 inch (11.1 mm) and maxi- 2• mean roof height,h, does not exceed least horizon- mum panel span of 8 feet (2438 mm) shall be tat dimension. permitted for opening protection in one- and Building, ®pen. A building having each wall at least c two-story buildings. Panels shall be precut to 8011 open. "This condition is expressed for each wall by 3 cover the glazed openings with attachment hard- the formula A.>_ 0.8 A„where: - ware provided. Attachments shall be designed to ` resist the components and cladding loads deter- Ao= total area of openings in a Nvall that receives mined in accordance with Table 1606.2B. positive external pressure, in sq ft (m2) Attachment in accordance with Table 1606.1.4 is TABLE 1606.1.4 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS _ FASTENER FASTENER SPACING(In.)1,2 = TYPE _ Panel Span 5 2 ft 2 ft<Panel Span 4 ft<Panel Span 6 ft<Panel Span <4ft <6ft <8ft 2 112#6 Wood Screw-t 16 16 12 9 2 112=8 wood screws16 16 16 12 Double-Headed Nails; 12 6 4 3 Sl: 1 inch=25.4 mm I foot=305 mm t P7 I. This table is based on a maximum v:intl speed of 130 mph(58 m!s)and mean roof height of 33 feet(10 m)or less. 2. Fasteners shall he installed at opposing ends of the wood structural panel. _ 3. Where screws are attached to masonry or masonry/stucco.they shall be attached using vibration-resistant anchors having a minimum withdrai al capac- ity of,190 1b(2180 kN). V 4. Nails shall be 10d common or 12d hox dnuble-headed nails. FLORIDA BUILDING CODE—BUILDING 16.5