HomeMy WebLinkAboutProduct Approval CREEKjt► TAMKO BUILDING PRODUCTS
`„s [� Asphalt Shingles
f TECHNICAL SERVICES,LLC
Heritage@ Premium Basic Wind Speed(Vut): Max. 194 mph
(Frederick) Basic Wind Speed(V.d): Max. 150 mph
Deck(HVHZ): In accordance with FBC requireme its;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non+l[VHZ): In.accordance with FBC requirements;
Solidly sheathed min, 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.,slope. 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes.greater than 21:12. .
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using' 6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
.Pattern'or"6 Nail.Pattern"detailed below.
NAIL ZONE/
FASTENERS COMM I6N BOND
5112" EXPOSURE 5"
1"-►) �I-- 11"—►� 12" —► -11 --►+ �-1
Figure 8. Heritage®Premium(Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERS COMMON BOND
5f12" EXPOSURE .9"
Figure 9. Heritage®Premium(Frederick)
6 Nail Pattern
i
TBP15001.2 FL18355-R2 Page of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
f
TAM, O BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES,LLC
Heritage@ Woodgate Basic Wind Speed(V,dt): Max. 194 mph
(Frederick). Basic Wind Speed(V,,d): Max. 150 mph I
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: Inaccordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC I requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 2T 12.
Installation (Non-HVHZ): Installed with 5 in. exposure inl accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall.be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAIL ZONE/
FASTENERS COfdMON BOND
T
5.1/2 -EXPOSURE Y
1'''i !+r— 11" -�►�-12-3/8"—I►�— 11„
Figure 10. Heritage®Woodgate(Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZON E/
FASTENERS COMMON BOND
t T
5'112" EXPOSURE 5"
3
Jr
1"�-►I I4- 3-1/2"-►�4�3'4�f-9-3/8"�3'1►E+tf-9-112"� �1--1"
Figure 11.. Heritage®Woodgate(Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
i
i
TAMKO BUILDING PRODUCTS
CREEK
AShingles
TECHNICAL SERVICES.LLC
Heritage®Vintage® Basic Wind Speed(Vut): Max. 194 mph
(Phillipsburg) Basic Wind Speed Msd): Max. 150 mph
Deck(HVH.Z): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/321 in. plywood existing
construction. i
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. pll/wood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21.:12.
Installation(HVHZ): Installed with 5 in, exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"5 Nail
Pattern"or"6 Nail Pattern"detailed below.
—aa' r,
i u mn: Eg6sure
T � t�ten z Pbpch
6" Fastengs
.IJ�iI
- - - -' - - - - - - -
are
17-112"
our
5"
Ek pose re
.0
Figure 12. Heritage®Vintage®
5 Nail Pattern (non-HVHZ only)
�r E7tp7SYR
Notch
. +Ib�irt
T wwas
T +
6• F oteners pull,- - - - - - — - - Zone
17-1/Y
S
OKI—p
z 77J{' 7�W—s� —7lR'—s�s-7iJd
67R io-if4�—►� w-16114 S-7!a'
Figure 13. Heritage®Vintageo'
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for,which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK
TAMKO BUILDING PRODUCTS
V 1 EEK Asphalt Shingles
TECHNICAL SERVICES,LLC
Hip&Ridge Basic Wind Speed(Vut): Max. 194 mph
(Frederick&Joplin) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 lin. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32.in. plywood or wood plank for
new construction;Min.7116 in.OSBlexisting construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start 5-1/8" exposure l
here—
Start
Figure 1 here 5-1/8"exposure
lip
6,4�a''
? Fastener "5
Fastener
Figure 2 Figure 3
1/4"
Figure 14. Hip&Ridge(Frederick&Joplin)
i
i
I
TBP15001.2 FL18355-R2 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
TAM KO BUILDING PRODUCTS
CREEK II Asphalt Shingles
TECHNICAL SERVICES,LLC
i
Vintage®Hip&Ridge Basic Wind Speed(Vat): Max. 194 mph
(Phillipsburg) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements:
Installation: Installed with 5 inch exposure in!accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Directiofd
n of prevailing win
art 5" exposure
here—
M .
Start
here 5" exposure
Figure 1
1"
} J
Fastener Fastener rl
' �5-1/2" t5-112"
Figure 2 1/4" Figure 3
Figure 15. Vintage®Hip& Ridge(Phillipsburg)
TBP15001.2 FL18355-R2 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
i
CREEKE E iP TA i KO BUILDING sphaltShingles
TECHNICAL SERVICES.LLC
i
LIMITATIONS
, I
1) Fire Classification is not within the scope of this evaluation..
2) The roof deck andthe roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements'.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B&.0 with a building mean roof height of 33-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the:laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC; and the manufacturer's
published application instructions. Where discrepancies exist between these sources,the more restrictive
and code compliant detail shall prevail.
8) All products listed in thirt
s report be manufactured under a quality assurance pr Igram in compliance with
Rule 61620-3.
COMPLIANCE STATEMENT i
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance I ith the Florida Building
Code 51"Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
G�PRY•R:•pR: 2 01,5.12.14
No 74021 13:44:19
_ 05'00'
0t STATE OF :��/
••
Al ��` Zachary R.Priest,P.E.
i�Fs •O R, C4�.` Florida Registration No.7402:1
t1j,ONAX- itc%` Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in.any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.2 FL18355-R2 I Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration forlwhich this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
§ :��
y<N1
3'�t�.�'qy%�� 4,�„ ". r_'.:�..,:,�'& � ,,ba.,.; d�, ''�w�5}'�'' •.� �"�� 3��'a50-�i'ew.�,u.,.s3 .. ,..'. " v
i
BCIS Home j Log In User Registration Hot Topics Submit Surcharge Stats&Facts j Publications FBC Staff SCIS Site Map Links Search
d'
b
a
z.r,.
��r Product Approval
hex. � ".USER:Public User r
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL18355-R2
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri—eden@tamko.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
d' Validation Checklist-Hardcopy Received
Certificate of Independence FL18355 R2 COI TBP15001.2 FBC 2014 Product Evaluation Report
Shinales.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3161 2009
ASTM D 3462 2009
ASTMD D 7158 2008
TAS 100 1995
I
i
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/16/2015
Date Validated 12/18/2015
Date Pending FBC Approval 12/19/2015
Date Approved 02/10/2016
Date Revised 05/09/2017
Summa ry of Products
FL# Model,Number or Name Description
18355.1 Glass-Seal, Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Vintage, Hip and Ridge,and Vintage
Hip and Ridge Shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL18355 R2 11 TBP150011.2 FBC 2014 Product Evaluation
Approved for use outside HVHZ:Yes Report Shinales.Ddf ;
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL18355 R2 AE TBP15001.2 FBC 2014 Product Evaluation
Report Shinales.Ddf
Created by Independent Third Party: Yes
Sack Nr..xt
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accl ssibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response toga public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
cCtk
Credit Card _
Safe
I
I
l
I
P Certificate of Authorization No.29824
Uml=MEK
17520 Edinburgh Dr
• Tampa;FL 33647
TECHNICAL SERVICES, LLC ! (813).480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5T"EDITION(2014)
I
Manufacturer: TAMKO BUILDING PRODUCTS !s lsued December 14,2015
220 West 0 Street
Joplin,MO 64801
(417).624-66.44
Manufacturing Plants: Joplin,MO
Phillipsburg,KS
Frederick,MD
Dallas,,TX
Tuscaloosa,AL
Quality:Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
ER& Report No. Standard Year
PRI Construction.Materials Technologies(TST5878) TA13-043-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995
PRI-Construction Materials Technologies(TST5878) TAP-1`17-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-1'30-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP=303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PR(Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)el
PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 j
UL LLC(TST9628) 02NK9507 ASTM D 3161 2009
U4 LLC(TST9628) 04NK24366 ASTM D 3462 2009
UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(M3)e1
UL 2390
ASTM D 7158 2008d
UL LLC(TST9628) 06NK03898 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 08CA59132 ASTM D 3161 2009
UL LLC'(TST9628) 09NK07896 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 1DCA50498 ASTM D 3462 2009
UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2009
UL LLC(TST9628) 11 NK14014 ASTM D 3161 2009
ASTM D 3462: 2009
UL LLC(TST9628) 12CA24551 ASTM D 3161. 2009
UL LLC(TST9628) 4786110543 ASTM D 6381, 2008(2013)el
UL LLC(TST9628) 4787043752 ASTM D 3161, 2009
UL LLC(TST9628) 4787148748 ASTM D 7158 2008d
ASTM D 3161 2009
ASTM D 3462 2009
i
I
TBP15001.2 FL18355-R2 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,.LLC of any product changes or quality assurance changes-throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
I I
. I
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass-Seal® 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing,.3-tab
(Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4"x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only. -
Heritage@ 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin,Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium 13-1/4" x. 39-3/8", ASTM D 3161, Class F and ASTM D 71.58, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage@ Woodgate 12" x 36-318", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 1T, ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage@ Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.2 FL18355-R2 Page.2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
i
i
TAMKO BUILDING PRODUCTS
CREEK I Asphalt Shingles
TECHNICAL SERVICES,LLC i
INSTALLATION
i
Elite Glass-Seal® Basic Wind Speed(Vut): Max. 194 mph
(Frederick,Joplin& Basic Wind Speed(Vag): Max. 150 mph
Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Glass-Seal new construction; Min. 15/32 in. plywood existing
(Frederick,Joplin(Non- construction.
HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with,FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood.plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBCI requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS
415 and manufacturers published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail.Pattern"detailed below.
NAILS
n
Nailing F -6-7/8
Area _........ ..-�._._. .::__._ ....---- ---...... ......... ....... .
5-118"
Butt:Edge
Figure 1. Elite Glass-Seal&Glass-Seal
4.Nail Pattern (Non-HVHZ only)
NAILS
Nailing - - ...... .... _.... -
-
Me --..----------------- -- --
...__.:..---- -------_- .... _.
Bull Edge
Figure 2. Elite Glass-Seal&Glass-Seal
6 Nail Pattern
TBP150012' FL1E355-R2 Page of 11
This evaluation report is provided for State of Florida product approvai,under Rule 61020-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report-does not express nor imply warranty,installation, recommended use,or other pro duct attributes that are not
specifically addressed herein.
TAM�KO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES, LLC
Heritage@ Basic Wind Speed(V,ut): Max. 194 mph
(Dallas,Frederick;Joplin, Basic.Wind.Speed(Vasd): Max. 150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC'requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Heritage®Premium new construction; Min. 15/32 in. plywood existing
(Dallas,Frederick construction.
Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 15/32 in. plywood or wood plank for
Heritage@.Woodgate new construction;Min.7/16 in.OSB existing construction.
(Dallas&Frederick) Underlayment: In accordance with FBC requiremehts.
Min.slope: 2:12 and in accordance with FBCI requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21':12.
Installation(HVHZ): installed with.5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using;"6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attj'ched using either"4 Nail
Pattern"or"6 Nail Pattern"detailed below.
FASTENERS NAIL ZONE
- COMMON
BOND
6-1/8" EXPOSURE 8-66/8"
1" — 12-11211 12-3/811 12-1/2'"1111 —1 It
Figure 3. Heritage®, Heritage@ Premium,and Heritage®Woodgate(Dallas)
4 Nail Pattern (non-HVHZ only)
�I
FASTENERS NAIL ZONE
COMMON
BOND
6-118" EXPOSURE 5-5/8"
1� �4-7-112'=�-7-112"-►�+1- 7 ,18"-�-7-1/2"-►}+�-T-1/2"-►� hl-1"�
Figure 4. Heritage®&Heritage®Premium
6 Nail Pattern
i
TBP15001.2 FL18355-R2 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein. I
I
I
I
I
CREEK
TAMIKO BUILDING PRODUCTS
( Asphalt Shingles
TECHNICAL SERVICES,LLC
NAIL°.'ZONE!
- ASTENERS
COMMON BOND.
Y
T
EXPOS URE55/8"
." �7-1121+7.112'�i►' 7!W81+Al2+A12411►
Figure 5. Heritage®Woodgate
6 Nail Pattern
-►�1"i1"i+ 12=t/2"—='r If-12-1/2„ ►1rt.,I
i i i i i i
Common Bond
FASTENERS
a�
Eo "m
UT d. r
1
+ 39-3/8" .—
Figure 6. Heritage@, Heritage@ Premium, &Heritage®Woodgate
Alternate 6 Nail Pattern
PAINT
LINE
7-7I8° ------•---__..__.___--•------•------____._.-_._r-.__-_._____ __-_-: _:}NAIL,ZONE
6-1I8" EDGE-OF..
COMMON_
j� BOND'
EXPOSURE
5-5/8"
ACCEPTABLE.
FASTENER LOCATION
D"O.NOT FASTEN
ALONaEDGE OF
-._- ---
COMMON BOND
PREFERRED
FASTENER
LOCATION'
Figure 7. Heritage®(Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4,and 6 may be placed in the nail zone asidescribed above
TBP15001.2 FI-18355-R2 Page 5 of.11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other'product attributes that are Piot
specifically addressed herein.
;l
9/24/2015 Florida Building Code Online
rte-
` ,
tea` •� � � � ;���`� „ �� It
V9 0972=.... 1
Florida DepaftfTterltq BCIS Home i Log In User R4istratlon I Hot Topics Submit Surcharge Stats&Facts Publications FBG Staff j BCIS Site Map Links i search
Busines}�fij�""�,)
Professi l�al 4 PER:Pub AUs royal
USER:Public User
Regulation ,
.. Product Approval Menu>&oduct or Application Search>Application List>Application Detail
w
FL# FL10758-R6
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@c)wenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740)321-6345
greg.keeler@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed,-
Florida
icensed;Florida Professional Engineer
J Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation'Report
Florida License PE-74021
Quality Assurance Entity Miami-Dade BCCO-QUA
Quality Assurance Contract Expiration Date 04/13/2018
Validated By Locke Bowden
Validation Checklist-Hardcopy Received
Certificate of Independence FL10758 R6 COI OCR14003.2 2014 FBC nonHVHZ Evaluation Report
Owens Corning Vents 060514.pdf
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certlfied By
Sections from the Code
1709.2
https:/tfloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvldAviteOYOp/o2bC3zFtrydggubWMrxzLHkvIrEPVYDHgEQp/pad%3d I 1/2
f
9/24/2015 Florida Building Code Online
Product Approval Method Method 2 Option B
Date Submitted 02/23/2015
Date Validated 02/24/2015
Date Pending FBC Approval 03/01/2015
Date Approved 04/15/2015
i
I
Summa of Products
FL# Model,Number or Name Description
10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic ridge vents for installation
Moisture Ridge Vents in shingle roof systems i
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10758 R6 II OCR14003.2 2014 FBC nonHVHZ Evaluation
Approved for use outside HVHZ:Yes Report Owens Corning Vent's 060514.Ddf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:Refer to evaluation report Evaluation Reports
FL10758 R6 AE OCR14003.2 2014 FBC nonHVHZ Evaluation
Report Owens Corning Vents 060514 odf
Created by Independent Third Party: Yes
10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent
Roof Vent With Exterior Louver
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10758 R6 II OCR14003.2 2014 FBC nonHVHZ Evaluation
i. Approved for use outside HVHZ:Yes Report Owens Corning Vents 060514.ndf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Thil d Party: Yes
Other:Refer to evaluation report. Evaluation Reports
FL10758 R6 AE OCR14003.2 2014 FBC nonHVHZ Evaluation
ReDort Owens Corning Ventsl060514.ndf
Created by Independent Third Party: Yes
10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10758 R6 II OCR14003.2 2014 FBC nonHVHZ Evaluation
Approved for use outside HVHZ:Yes Report Owens Corning Vents 1060514.odf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
_ Other: Refer to evaluation report. Evaluation Reports
FL10758 R6 AE OCR14003.2 2014 FBC nonHVHZ Evaluation
Report Owens Corning Vents'060514.odf
Created by Independent Third Party: Yes
eae3r flext.
I
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
_ The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-retards request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address It they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
securityMkim(ts'
https://floridabuilding.org/pr/pr_6pp dfl.aspx?param=wGEVXQwtDgvIdAvlteOYO*/o2bC3zFtrydggubWMrxzLHkvlrEPVYDH9EQ°/pad°/*3d 2/2
I
i
Certificate of Authorization No.29824
17520 Edinburgh Dr
CREEK Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC I(sued February 23, 2015
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465
www.owenscorning.com
Manufacturing Plants: Rohnert Park,CA;Orrick, MO; Baldwyn, MS; Niles, OH
QualityAssurance: Miami-Dade BCCO—QUA QUA1591
( )
SCOPE
Category: Roofing
Subcategory: Roofing Accessories that are an Integral Part of the Roofing System
Code Sections: 1709.2
Properties: Roof Ventilation
REFERENCES
Entity Report No. Standard Year
Architectural Testing,Inc(TST1558) 01-38660.04 TAS 100(A) 1995
Architectural Testing,Inc(TST1558) 01-38660.05 TAS 100(A) 1995
Architectural Testing,Inc(TST1558) C1774.01-109-18 TAS 100(A) 1995
ASTM D 635 2006
ASTM D 1929 2001e01
ASTM D 2843 2004e01
PRI Construction Materials Technologies(TST5878) AVIG-005-02-01 ASTM D 635 2006
ASTM D 1929 2001e01
ASTM D 2843 2004e01
PRI Construction Materials Technologies(TST5878) AVIG-006-02-01 ASTM G 155' 2005a
PRI Construction Materials Technologies(TST5878) OCF-111-02-01 ASTM D 635. 2006
ASTM D 1929 2001e01
ASTM D 2843 2004e01
PRI Construction Materials Technologies(TST5878) OCF-112-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) 0CF-116-02-01 TAS 110(A) 1995
PRI Construction Materials Technologies(TST5878) OCF-223-02-01 TAS 110(A) 1995
PRI Construction Materials Technologies(TST5878) OHI-007-02-01 TAS 100(A) 1995
PRODUCT DESCRIPTION AND APPLICATION
VentSure� 4-Foot Strip 1-1/4" x 14-7/8" x 48" low-profile attic ridge vent consisting�?f a two-layer nylon-
Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for
Vents: installation in shingle roof systems.
48"
14-7/8"
, I
OCR14003.2 FL10758-R6 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK j
Technical Services,LLC of any product changes or quality assurance changes throughout the duration ifor which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
i
OWENS CORNING ROOFING AND ASPHALT LLC
�entSure®Roof Ventilation
C R
E EIF<
I
TECHNICAL SERVICES, LLC
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12 to maximum 16/12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) cent6led in the deck at the
ridge for ventilation. The slot shall terminate approximately 6-inches from the rake
edges. Apply a %<-inch wide bead of ASTM D 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to thel field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga.2%-inch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent! Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section. Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga. 2%z-inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) prvided with the veritIor as directed by the
shingle manufacturer's installation instructions. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
VentSureo Low Profile 18"x 24"x 2-3/16"(32"x 23"flange base)static off-ridge vent:composed of ASTM
Slant Back Roof Vent A653 galvanized steel(available with painted finish). Material shall conform with
with Exterior Louver: FBC Section 1507.4.3.
i
i
�s-
i
I---�° •gr �-4---{-i- tee.,,•..,..._._ _:„.1
7
�RArO f '(
a i
-}-
I I 1
-.
Y
� r
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in 'accordance with FBC
requirements.
I
OCR14003.2 FL10758-R6 { Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
i
OWENS CORNING ROOFING AND ASPHALT LLC
CRE
`'. lVentSureo Roof Ventilation
TECHNICAL SERVICES, LLC
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft
Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM DI4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof. Fasten vent 4-inches o.c.and 1-inch from outside edge of flange
with minimum 12 ga. ring shank roofing nails (shall comp�y with FBC Section
1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per
vent).
Install baffle in '/4-inch bed of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with; FBC Section 1506.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement.
Allowable Roof Coverings: Asphalt shingles
VentSureo Rigid Roll 5/8"x 11-1/4"x 20'attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun-bond polypropylene fabric.
24 ~
i
Cf
i
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
i
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 1,2-inches from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to the feld shingles. Center
the vent over the opening and fasten the vent 24-inches 'oic. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with' FBC Section 1506.5),
ensuring%-inch penetration through wood deck.
Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails(shall comply with FBC Section
1506.5) or as directed by the shingle manufacturer's installation instructions,
ensuring%-inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
OCR14003.2 FL10758-R6 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
I
i
- 1
OWENS CORNING R 0OFING AND ASPHALT LLC
IVentSure®Roof Ventilation
CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is outside the scope of this evaluation.
2) This report is not for use in the HVHZ.
3) The roof deck and deck attachment shall be designed by others in accordance with'the 2014 FBC.
4) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shall be enforced.
6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion prior to installation.
7) Installation of the roof assembly is outside the scope of this evaluation.
8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated complian le with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
R,I p �i 2015.02.2
CX\•••.......• 9�F :., ....
CEN _,....
"P.. SF• 's,- 3 14:48:59
No 74021
-05'00'
STATE OF
%�•(�• A, p;.�� Zachary R. Priest, P.E.
-4 O R k p' ,` Florida Registration No.74021
Organization No.ANE9641
i
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company lanufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
i
END OF REPORT
OCR14003.2 FL10758-R6 !' Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The mahufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration Ifor which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other.product attributes that are not
specifically addressed herein.
i
I
I,
6/30/2015 Florida Building Code Online
3
Florida Departmentcf SCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats&Facts Publications FBC Staff �' BCIS'Site Map I Links Search
Bushes -- Product Approval
USER: Public UserProfessi kal
j
Regulation
I,
Product Approval Menu>Product or Application Search>Application List>Application Detail
I
°. FL# FL2569-R9
Application Type Revision
Code Version 2014
Application Status Approved
I
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema,ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 lea n-Berchmans-Michaud
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert]. M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL2569 R9 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
https://floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsKQFEnckBl08ErxlUd3xYIX2p/`2f`/`2bLT9pl88`/o3d , 1/2
s �
6/30/2015 Florida Building Code Online
TAS 110 2000
i
Equivalence of Product Standards
Certified By
I
I
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/17/2015
Date Validated 04/21/2015
Date Pending FBC Approval 04/25/2015
Date Approved 06/23/2015
Date Revised 06/29/2015
Summary of Products
FL# Model,Number or Name Description
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL2569 R9 II 2015 04 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R9.Ddf
Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE :)9166
Design Pressure:+N/A/-90 Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reports .
Use. 2.)The design pressure noted herein FL2569 R9 AE 2015 04 FINAL ER SOI REMA CA UNDERLAYMENTS FL2569-
pertains to underlayment systems used R9
beneath adhesive-set tile systems. Refer to Created by Independent Third Party: Yes
ER Section 5.6.4 for details.
ax;cat Next.
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement:: Accessibility Statement:: Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response tfo apublic-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.