Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online `�1 Page 1 of 2 l",'IridaDewmrW sas m.. •LN in tWr RpNbytbn Hat r 6Us nes ��II TOWS SUtM„R SURharge Stats a Faaa INI)DOtbna FBC staff Ods Site Map Un" 'sacra, �rdessla) �- Product Approval Regulation `rL�� usea:public user v..+4•t_PC•ro�a ',y,n _&�C�L%ipPL:a:cn c,• > FL# t„rc .41,101>AppUatbn p*W F1 ECAppli FL10674-R9 Code ode Version Type Revision OCT 2 6` 2017 C Application Status 2010 Approved PFR"/I(7TI,yt; Comments 5t Lt ire Archived (,10un[y. FL Product Manufacturer Address/Phone/Small Owens Corning One Owens Coming Parkway Toledo,OH 43659 (740)404-7829 „tYs. greg•keeler®owensqLRrAin%.c 3 4 Authorized Signature L Greg Keeler grog.kee ler®owenscoml ng.com Technical Representative Address/phone/Email Mel 1 Owens ens CSancraorning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrantoowensco mig.com Quality Assurance Representative Address/Phone/Email Category Subcategory Roofing Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert J.M. Nleminen Florida License Quality Assurance Entity UL LLC 66 Quality Assurance Contract Expiration Date 09/26/2014 Validated By John W.Knezevlch, PE validation Checklist-Hardcopy Recelved Certificate of Independence 'Vlemir, n r•r,r' Referenced Standard and Year(of Standard) fan d ASTM D3161,Class F Year ASTM D3462 2006 ASTM D7158,Class H 2007 2007 Equivalence of Product Standards Certified By http://w'ww.floridabuilding.org/pr/pr app dt"aspx?param=wGEVXOWtDotRN},FVSvo/.,)u Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/28/2014 Date Validated 03/05/2014 Date Pending FBC Approval 03/05/2014 Date Approved 04/18/2014 iSummary of Products FIL Model Number or Name IDescription 10674,1 Owens Coming Asphalt Roofing 3-tab,4-tab, 5-tab,laminated,starter and hip&ridge IShingles and Starters shingles Umits of Use Installation Instructions Approved for use In HVHZ: No FL)0674 R9 II 2014 03 FINAL OC ASnhalt Approved for use outside HVHZ:Yes Shlnales FL10674-R9.pdi Impact Resistant: N/A Verified By: Robert 3. M. Nleminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R9-AE 2014 03 FINAL OC Asper Shlnales FL10674-R9.odf Created by Inde ndent Third Party:Yes Bata: � C Next -J [,QptlCt,Us::1940 hortn Monroe Street Tallahai a FL 32199 phone:850-487-1824 The State of Flonda is in AA/EEO employer.Copyright 2007-2013 State o°Flor da.::Pr vacv Statement::Access oillty Statement Refund Statement under Florida law,email addraliass are public records.If you do not want your e-mall address rebased In response to a pudic-recordb request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395, pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Depertrrhent with in email address if they have one.The smalls provided may be Lead for cf1i communication with the Ilcenses.However emaii addresses are public record.If you do not wish to supply a personal address,please provide the Department with an emar address which can be made available to this public. 70 determine if you are a licenses under Chapter 455,F-S.,please dick bc=. Product Approval Accepts: im .'Unit V!.ltla� http://www.floridabuilding.org//Dr/or ann cit] acnx�naram�. r(:�Y7Yll..,r�,.o,.T1rv«rn�� OCT 2 6 2017 PERMITTING St. Lucie County, FL EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 TRINI� ARD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R4 One Owens Corning Parkway FL10674-R9 Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 4: 03/04/2014 SCOPE: This Evaluation Report is Issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials In the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nleminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityjERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle, ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPecTxoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for Inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: ✓ t f" ' tC; The facsimile seal appearing was authorized by RobertNleminen,P.E.on 03/04/20:4 5��• ���/ This does not serve as an electronically signed Robert J.M. Nieminen P.E. rFSr' •i a. document. Signed,sealed hardcopies have been F � �ft�L +`� transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DG4 ANE1983 to the named client CERTIFICATION OF INDEPENDIll 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products It evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest In any other entity involved In the approval process of the product. TRINJI Y ERD ROOFING SYSTEMS EVALUATION: I. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, 8905.2.6,1 Wind Resistance ASTM D7158,Class H 2007 3. REFERENCES: Entity Examinatlon Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol. 3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance IICA34308 02/18/2012 UL LLC (TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade (CER1592) FBC HVHZ Compliance Various NOAs various UL LLC (QUA9625) Quality Control Service Confirmation 82453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic® and Supreme®are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire@ are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duratlon(', TruDefinition® Duration®, Duration® Premium Cool, TruDefinition® DurationO Designer Color Collection, TruDefinitlon® Oakridge®, Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshtre® Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRldge'^' Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles, S. LIMITATIONS: 5.1 This Evaluation Report Is not for use in the HVHZ, 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Fxterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certfflcate of Authorizadon#9503 FL10674-R9 Revision 4.,03/04/2014 Page 2 of 7 TRINITY ERD 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507,2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us In all wind zones up to Va,d = 150 mph (Vit = 194 mph). Refer to Section 6 for Installation requirements to meet this wind rating. 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified In accordance with FBC Tables 1507.2.7.1 and R905,2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to V,,,d = 150 mph (Vint = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculatlons by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit In accordance with the Florida Building Code and F.A.C. Rule 9N-3, 6. INSTALLATION: 6.1 Underlayment: 6.1,1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507,2.4 or 8905.2.3. 6.2 Asphalt Shingles: 6.2,1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: Berkshire® shingles require minimum five (5) nails per shingle. v WeatherGuard® HP shingles require minimum six (6) nails per shingle. Devonshire i" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published Information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. Exterior Research and Design, LLC, Evaluation Report 037940.02.12-R4 Cerd1►cato ofAuthorizstion#9503 FL10674-119 Revision 4:03/04/2014 Page 3 of 7 TRINITY ERD 6.2.5 Minimum Nailing - Classic@ &Supreme: Normal Monsard or Am par& No"nel Menowd or Area pen WW Ames High Wind denwanes r VAnd Areas Wind y Area pen vientd#norroWsa Areas View hre"Of Amw pers viontos normaller Areas h.=%. Z. 1. IV t ,4A) ir suposure a OW Exposure EEXPCWJ*)6 xpodaMn 0 6.2.6 Minimum Nailing - Berkshire@: Salem strip seeds atr� U 1h do"AWN 4*a do enutt -----------0 'Of 0 Vf OW, 0 Yi' a t Alphatoofintio~ 6.2.7 Minimum Nailing - DevonshireTm-. 4 Nails Nets ...........All Ton I-Spoiae[A"haft Rod Cement 6.2.8 Minimum Nailing - Duration& TruDefinitlon(& Duration, Duration® Premium Cool & TruDetlnitionO Duration® Designer Color Collection: 4 Nag PAWS Nag Eulwoma d#4 Mob Ina loom OPROwto Sumq%111 bowling Ana wldth do e1 IWaa 4 favot Area do dues SumMY' 40 15V 9xpD"m Exposure W JwV.do"PoifoliDn pares Ppulig.doomp**Ivn %W Exposure talk Expo'.K. W'pdg.do ow"kW cloom 54-pu)#.do w(pasUm Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-114 Com"Illcate of AUthOPIZAPHOn#9503 FL10674-R9 Revision 4:03/04/2014 Page 4 of 7 TRINITY ERD 6.2.9 Minimum Nailing ' TruDeflnitioO Oakridge@, Oakridge@: 4 Nall Rattan 6 Nall Pattom Esquma con 4 c44s Esquuna con 6 dovos it 12- IInT_Ty� I _ _- I . 65/8°Expu,urs Nab 6SArExpoww Nails fxposlcfcn do 56/6 pufg. Clams Expodddn d/66/6pu* 6 6/B"k powe Clarof 6 518`Export 6xpoaFa4in d+6 6/6 ping. Exposlabn da 6 6/6 pufn. 6.2.10 Minimum Nailing - WeatherGuard@ HP: oft view :: 71ew� Qiw Wi lr..i iF.iia 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshlre® Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuardm HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidge7m Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, Including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate ofAuthortzation#9503 F11-10674-119 Revision 4:03/04/2014 Page 5 of 7 TRINITY ERD 6.3.3 Minimum Nailing - Berkshire@ Hip&Ridge and High Ridge: F1%I I F42 Women Urealen NOS - -------X.J- Top LRWNtod PA�7 Ft i M T 1 1 i 1 i;P25U1C 77- 6.3.4 Minimum Nailing - Hip& Ridge with Sealant: em Fkj.2-N' Wbd Famning Pattern i4 Nails rim Shinglle, nd Discard 2" f2" Excess lot 140 s:31prit — - trip 112" T Fastening 651,. 6 Exp O"'SO to Distance 12 6.3.5 Minimum Nailing -WeatherGuard(& HP Hip and Ridge: Fig.A Fig.C Hip&Ridge Shingle FaMaNng TopVWW Md" Norm Nall A.e It V V Z7 Exterior Research and Design, LLC. Evaluation Report 037940-02.12-R4 CartWicate of AuthoAration#9503 FL10674-R9 Revision 4.-03/04/2014 Page 6 of 7 TRINITY ERD 6.3.6 Minimum Nailing - ProEdge Hip &Ridge Shingles: Prevelling Standard 11' Wind Direction Fastening 9,h,,BtriA 4 Pattern �'� a•lisp°""' T•I h •; I-r Foran 7h' t,ti.Covw 8'Expos t Frrtenmwith Rauf Comottt 6.3.7 Minimum Nailing -DuraRidge"" Hip&Ridge Shingles: Note: The drawings below pertaln to minimum, as-tested attachment requirements. Refer to Owens Corning published Installation Instructions for their minimum requirements. Topv9ow r..0' IaM hBi oast V Vkam epun Dit°�iadonAltlrmprdxni.nn Wpo,br I' t 1 Cf I• OVJNO�SW W� • CM.e ��►� \X �Iw t i I 18ts 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction In order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC-QUA9625 ; (414) 248-6409; karen buchmann0ui com - END OF EVALUATION REPORT - Exterior Research and Design,LLC. Evaluation Report 037940.02.12-1114 certNfcate ofAathorWtion 99503 FL10674-Rg Revision 4:03/04/2014 Page 7 of 7