Loading...
HomeMy WebLinkAboutBuilding Permit ApplciationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: • Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT APPLICATION FOR: Plumbing PROPOSED IMPROVEb&NT LO ` Address: 1825 PARK LANE Legal Description: PARKWAY GROVE ESTATES - UNIT - BLK 4 LOTS 7,8 AND E 10FT OF LOT 9 (0.51 AC) Property Tax ID #: 2313-701-0013-000-3 Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WOR REPLACEMENT OF 50 GALLON HEATER WITH EXPANSION TANK, PAN AND PERMIT CONSTRUCTION INFORMATICf ,:- -.., , AcIditional work toe erorme under tispermit—c ec a appy: QHVAC E] Gas Tank E]Gas Piping _ Shutters ❑ Windows/Doors Electric ❑✓_ Plumbing ❑Sprinklers Generator Roof qi �Ft. of First Floor: Total Sq. Ft of Construction: S" Cost of Construction: $ 1,300.00 Utilities: J Sewer Septic Building Height: :`bWNER/LESSEE; CONTRACTOR. Name WAYNE & CAROLYN LEONARD Name: RICHARD BASSOFF Address: 1825 PARK LANE Company: ADMIRAL PLUMBING SERVICES, LLC City: FORT PIERCE State: FL Address: 2895 JUPITER PARK DRIVE #700 City: JUPITER State: FL Zip Code: 34945 Fax: Phone No. 772-9714791 Zip Code: 33458 Fax: E-Mail: Phone No. 561746-1180 Fill in fee simple Title Holder on next page ( if different E-Mail: christine@theadmiralpiumber.com State or County License: CFC 1426115 from the Owner listed above) If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the_jcst_inspection. If you intend to obtain financing, consult with lender or an attorney before _ Signature of Owner/ STATE OF FLORIDA COUNTY OF PAwemm The Tfgg t ng instrument was acknowledged,4efore me this,�dayof 67,77-r 201�by M(�d'� C SOJ (Name of IMrson acknowledging) of Notary Known Ajpe of Identification Pi Commission No. `^ " Revised 07/15/20 OR Produced Identification hale of Forda Costa a GG 032841 Holder STATE OF PEORIDA COUNTY OF PAW eFACH Thejfqrg�ng instru e t was acknowledged before me [his -01 dayof C��%i'r 20 j 1 by U�ld �G.iio � (Name of person acknowledging ) Notary Public- State C/ Pe/tonally Known T pe of Identificat Commission No. _i OR Produced Identification "o-817 ond° gpWe State of F $uSen18.Qn � 032841 REVIEWS FRONT ZONING SUPERVISOR DESIGNER ENGINEER: _ Name: Not Applicable SEA TURTLE MORTGAGE COMPANY: _ Not Applicable Name: Address: COUNTER REVIEW Address: City: Zip: Phone: State: _ City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Name: Not Applicable BONDING COMPANY: _Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the_jcst_inspection. If you intend to obtain financing, consult with lender or an attorney before _ Signature of Owner/ STATE OF FLORIDA COUNTY OF PAwemm The Tfgg t ng instrument was acknowledged,4efore me this,�dayof 67,77-r 201�by M(�d'� C SOJ (Name of IMrson acknowledging) of Notary Known Ajpe of Identification Pi Commission No. `^ " Revised 07/15/20 OR Produced Identification hale of Forda Costa a GG 032841 Holder STATE OF PEORIDA COUNTY OF PAW eFACH Thejfqrg�ng instru e t was acknowledged before me [his -01 dayof C��%i'r 20 j 1 by U�ld �G.iio � (Name of person acknowledging ) Notary Public- State C/ Pe/tonally Known T pe of Identificat Commission No. _i OR Produced Identification "o-817 ond° gpWe State of F $uSen18.Qn � 032841 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS PLUMBING SERVWES Invoice 154691 Invoice Date 10/272017 Terms COD Completed Date 10272017 Customer PO Billing Address I Job Address WAYNE LEONARD WAYNE LEONARD 1825 PARK LANE 1825 PARK LANE FORT PIERCE, FL 34945 USA FORT PIERCE, FL 34945 USA Description of Work REPLACEMENT OF 50 GALLON ELECTRIC HEATER WITH EXPANSION TANK AND PERMIT Task # Description Quantity Your Price Your Total T42610 STANDARD 50 GALLON ELECTRIC WATER HEATER - PLUS PERMIT AND 1.00 $1,050.00 $1,050.00 UPGRADES A99536 PERMIT -PLUMBING 1.00 $175.00 $175.00 A13210 3/4" BALL VALVE - CXC 1.00 $75.00 $75.00 Paid On Type Memo Amount 10/27/2017 Visa $1,3300.00 Sub -Total $1,300.00 Tax $0.00 Total Due $1,300.00 Payment $1,300.00 Balance Due $0.00 Terms: ALL ESTIMATES ARE GOOD FOR 30 DAYS. All material is guaranteed to be as specified. All work is to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs w1l be executed only upon written orders and will become an extra charge over and above the estimate. All agreements confingent upon delays, beyond our control. All payments are due upon completion of installation. All payments not received upon completion are subject to 1 1/2% service charge per month, or the maxtmum rate permitted by law, whichever is less. In the event of non-payment, all costs incidental to collection, including without limitation reasonable attorney's fees shall be added to the unpaid balance, **DEPOSrFS FOR WORK REQUIRING PERMrr: In the event a deposit is given requiring a permit and the work is cancelled after pernit is pulled, refund will be given Menus any perm@ and adnenistrative fees that were paid by Adniral Plumbing. PLEASE MAIL ALL PAYMENTS TO: 2895 JUPrrER PARK DR #700 JUPITER, FL 33458 (561) 746-1180 I hereby agree to have Admiral Plumbing complete the work described for the proposed price regardless of the time it takes to complete the work. I hereby acknowledge the satisfactory N I authorize Admiral Plumbing Se purchase in accordance with the on of the above described work. LLC to charge the agreed amount to my credit card provided herein. I agree that I will pay for this I bank cardholder agreement. Professional Classic''' Specifications Residential Electric N Water Professional Classic Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGYINFO. ON- MOO¢ ttPE CAR NUMBER marrhoOR MTNO O1J4 RECWERI' IN MRN. EYFRM reser HEIGHT A HISMITTO WAIEROONN. B D.. t zewma. WIPM.. Heel WENOY 0sarsa Tell 30 PROEWnW951 48 21 47-1a 5039 19-1/4 92 a." TLI 40 PROE40T2RH951 57 21 80314 63-59 19-1/4 to 0.95 Tall 50 PROE50 T2 AH95T 67 21 Sews 6139 20-1/4 121 0.95 Tell 55 PROE5572 RH94I 71 21 57 59314 22-1/4 128 0.94 Med. 30 PROE30 W RH95r 44 21 37-1/2 4 lm 20.1/1 92 0.95 Med. 40 MM40W 101051 55 21 48-1/4 50-1/2 20.1/4 106 0.95 Med. 50 PROE50 M2 W951 65 21 48 50.1/2 23 132 0.95 Shod 19.9 P(10E2052 RH 21 3142 31 -IM 17 rel Short 28 PROEfe 82 RN95 42 21 30 31-1/8 23 95 0.95 Short 30 PROE3052 RH958'- 42 21 30-1/8 32 193x4 95 0.95 Short 38 PROE36 S2 RH95 45 21 31-1/2 33 24-1/4 118 0.95 Shottl 30 1 PR0E3852 RH95 B" 55 21 31-1/2 32-s/a 23 108 0.95 Short47 1 MM47 S2 R1195 B" 55 21 32 31 26-1/4 149 0.95 Energy Factor based on D.O.E. (Department of Energy) test procedures. t System Sentinel optional. Add EC1 to Ne end of the modal number Syatem Sentinel not available on single element modals, available on dual element models only. System Sentinel not available in excess of 5 kW on 203 V models, " Water heater dhnensions loner to installhg ienugton blanket (hal a Included vdth water teater • Heaters fumcrrW with standard! 240 volt AC, seWle phase nonvmuAarvous wvirg, and 4500 watt upper aryl b hear akmente. HOT • If heating elements of different wastes" than these shown ere demanded by zone requirements, they must be WATER specifically requested. CONNECTION, • Shgle elauwnt nxxlels evaleble On special Dorn (6"W max.). Substitute -1' for'2' in randet number. •Specal Winrg Opibrrs-AIImMed number of specW winos options are eva9eble. ConsuB factory for price and a+aleblliry. RELIEF VALVE • Ai modals wulpped who heat trepe. CONNECTION Recovery = wattagfv2.42 x temp. nse °F. Example: 45DOW =21 GFH C— z.42 x 90^ r DIAMETER Recovery caoUatbns used are based an 4500 watt beds read In nonentuftaneous operation. T A O B WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of continuous progress and product improvement. Rheem resertrs the right to make changes without notice. Pherson Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com PRINIEO IN Ua.A 08/16 We FORM NO. PROE RH N Rev. 2