HomeMy WebLinkAboutbuilding permitALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date:
Permit Number:
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X
PERMIT APPLICATION FOR: Shutter
PROPOSED IMPROVEMENT LOCATION,
Address: 8924 Champions Way, Port St Lucie, FL 34986
Legal Description: Lakes at PGA Village Block A
Property Tax ID #: 3334-501-0064-000-9
Site Plan Name:
Project Name: Richard Martin
Setbacks Front Back:
INSTALL 17 ACCORDION SHUTTERS
Additional worK to i3 ertormeci
1-1 HVAC _ Gas Tank
F]Electric ❑ Plumbing
Total Sq. Ft of Construction: 2412
Cost of Construction: $ 9908
Name Richard Martin
Address: 8924 Champions Way
Right Side: Left Side:
under this permit — chat ecK all napply:
F]Gas Piping Shutters
11 Sprinklers Generator
S. Ft. of First Floor: 1789
Utilities: _ Sewer F-1 Septic
City: Port St Lucie State: FL
Zip Code. 34986 Fax:
Phone No. 772-427-0395
E -Mail:
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
Name: Michael O'Donnell
Lot No. 50
Block No.
Windows/Doors
Roof �2 Roof pitch
Building Height: 12'
Company: O'Donnell Contracting
Address: 6402 SE Federal Hwy
City: Stuart State: FL
Zip Code: 34997 Fax: 888-833-0164
Phone No. 772-408-0200
E -Mail: rcdonne11311 @gmail.com
State or County License: CRC1331273
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
ESIGNER/ENGINEER:
ame•,
ddress;
itv:
ip: Phone:
EE SIMPLE TITLE HOLDER:
dame:
address:
-itv:
Zip: Phone:
Not Applicable
State
Not Applicable
MORTGAGE COMPANY:
Name:
Address:
Fity
Zip'. Phone:
BONDING COMPANY;
Name:
Address:
City:
Zip; Phone
::E-�:'_���..�' �i`: IFi��'�='ISI. Iii.-��; 1`,:�t"..•=, �-•-:
'�r...i_ ' ;�'' l`1�:�;,\1ij_i i1' yx•- .:1;." ;a'�1`�'NI'';i;•.
Not Applicable
State:
Not Applicable
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any, applicable Home OAssociation iandrreviewbylaws
your deed for -any restricd covenants tion which restrict Y appjy ,bit such
structure. Please consultwlth your Home Owners
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance_the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The (oliowing building permit applications are eyempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residentlal use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twieefor
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first Inspection. If you intend to obtain financing, consult with lender or an attorney before
commencin work or recording our Notice of Commencement,
S
_ Signature of U er/ Lessee/Agent: Signature of Contractor/License Holder
STATE OF FLORIDA _ STATE OF FLORIDA LU C L
COUNTY OF S I �,vc► COUNTY OF ST—
The forgoing Instrument was acknowledged before me
The forgoing instrument was acknowledged before e y m —
thisJO day of 06T_ , 20 )7by thls3®day of ®e'r 70 `� b
LCL4 Vi -CC ® 0o
(Name ofperson acknowledging) (Name of person ackno ledging )
(Signature of Notary Public -State of Florida )
(Signature of Notary Publlc- State of Florida )
Personal) Known OR Produced Identification
Personally Known OR Produced Identification y
Type of Identification Produced'.
Type of identification Pr dpGp ` .;,,.,•�w.I
I I.4Y Tg jJfISSION �FFo6hs5e Commission No,
(SealpALE FULLER
Commission No. `J. ` MY C01AMIS910N
"o CXf'IFiCS October 20, 2017 �'L•.•o�; R�FOn1 8
t Or •, i. ��� _
n• l° n, d�EX
%
,•1071 X98-0153 n r
F10rid2Notary5ervlce,com
Revised 0'7/15/2014
REVIEWS I FRONT I ZONING
COUNTER REVIEW
DA -TE
COMPLETE
INITIALS
SUPERVISOR PLANS
REVIEW REVIEW
VEGETATION SEA TURTLE MANGROVE
REVIEW REVIEW REVIEW
Property Card
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved.
Property Identification
Site Address: 8924 Parcel ID: 3334-501-0064- Account 4: 154897 Sec:/Town/Range:
Champions WAY 000-9 34/36S/39E
Map ID: 33/34N Zoning: PUD Use TNIPe; 0100 Jurisdiction: Saint Lucie
County
Ownership Legal Description
Richard N Martin (LF EST) LAKES AT PGA VILLAGE (PB 43-32) BLK A LOT 50 (OR
Jean Martin (I.,F FST) 3671-100: 3744-2235)
8924 Champions Way
Port St Lucie. FL 34986
Page 1 of 1
Total Areas
Finished/Under Air 1,789
(SF):
Gross Area (SF): 2.41.2
Land Size (acres): 0.17
Land Size (SF): 7.405
.._.......
"Total Building Count: 1
Special Features and Yard items
Type Qty Units Year Blt
Drive-BrkPav 1 703 2005
"This information is believed to be correct at this time but it is subject to change and is not -,warranted.
C1 Copyright 2017 Saint Lucie County Property Appraiser. All rights reserved.
http://www.paslc.org/RECardl 10/23/2017
........ ......... .
Current Values Historical Values 3 -year
Just/Mark-et:
5215.100 Assessed: $208.102 Year Just/Market Assessed
Exemptions 'Taxable
Exemptions:
$50,000 Taxable: $158,102 2017 $215,100 $208,102
$50,000 $158,102
1016 $203,800 5200,384
550,000 5150.384
3015 $195,600 x+195,600
$50,000 $145,600
Sale History
Date
Book,'Page Sale Codi: Deed Grantor
Price.
04-23-2015
3744 /2235 0114 QC Martin Richard Iii
5100
09-04-2014
3671 /0100 0001 WD Madden.Eleomora V
$263,500
06-15-2010
3207 / 2169 0001 WI) Bock.Fred
$230.000
Primary Building Information
Finished Area of this building: 1,789 SF
Gross Area of this building,: 2.412 SF
Exterior Data
View
Roof Cover: Clay 'riie Roof Structure: Hip
Bui.ldikQ TN pe: RA. -
Year Built: 2005
Frame.: Grade: A-
Effective Year: 2005
Primary Wall- CB Stucco Story Height: 1 Story No, Units: I
Secondary Wall:
Interior Data
Bedrooms: 3
A/C Ufa: 100% Electric:
Primary Int Wall:
Full Baths: 2
Heated %: I% Heat Type: Frcdl-lotAir
.Avg I-Igt'Floor: 0
Half Baths: 0
Sprinkled %-. 0% Heat Fuel: 1=LEC
Primary Floors: Tile: -Ceramic
Total Areas
Finished/Under Air 1,789
(SF):
Gross Area (SF): 2.41.2
Land Size (acres): 0.17
Land Size (SF): 7.405
.._.......
"Total Building Count: 1
Special Features and Yard items
Type Qty Units Year Blt
Drive-BrkPav 1 703 2005
"This information is believed to be correct at this time but it is subject to change and is not -,warranted.
C1 Copyright 2017 Saint Lucie County Property Appraiser. All rights reserved.
http://www.paslc.org/RECardl 10/23/2017
........ ......... .
*MV
Date, Impact Windows &
Storm Protection
Frepared I -)-v'
6402 SEF(,,deral Hwy,, Sj-L(ar;'-, FL 34.99-7
To -
1' 4 �W.r
FL 34.994
�
L4A &kln
Pro
ie's'c ri P fio V,
i nli waci ...........
C)
Eslimated Time for CompfetlCir],' Cr--j--*—,ieeks
`F FIXED E D '
IAWN /S -D/ GD/ F D./F El [xiox: xx, Oxo;Ox)(0.11 Amount
# Size Desc-ipfion ISH "HR "CA5EE/ .... ..
Style Glass Vinyl/Alum ".Olor GTHIS
3 q -
cc
>
2 4
71 15 1
4
G.
.-7
Ct7
7
8
9 3 G
1
3'A "A
12
ILI ...
...... . ...
. ........ ..
17 J, 4400
19
20
21 . . .......
OC
22
23
24*
yy
P
/,2
.. .... ....
7'
. . .........
Acceptance.
Acceptccl Bv: .. . ......... . . . ........ ... ............... . . . . ....................
.... . ...... ... ......... .-V
Date
'5
Accepted. . ......................... . ......... ........ . .. ......... ..... . ................................ .......... . ..................... . . ...... .. . ........ ......................
OlDo-nnell knpact !Aiinciows Date
Any unf iseen condificns such as;
P00%
:erry)F, and CandNon-. ihis esiimcteis for coroplefing ihe job described above, based on our C
mold, roildew, wood rnit, r-ajof slucco & dirp.,vallre,pair, rephocernri-mi,
prior io corr, c,ions cnd a controct addenaluirri wid be subn-nifl--d licion ogreern--,ni belvieen horne-owner and ContraCt!or, Ail -,,vort,nlanship
It �n- terials guarant-ed in bee specified, The'hc,1-ne`DV,`ner;S responi�'b�& f flood and ofl-ier n -e
essory insurance.
N
TH A t -!K t='0 (OR" R ER U S1 N S
3/27/2017 Florida Building Code Online
}lit
BCIS Home i Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map ':. Links Search
Florida
` 4Product Approval
, USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
s �s �� FL # FL1850-R10
"" " Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory CAccordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
y` Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Walter A. Tillit, Jr., P.E.
PE -44167
National Accreditation and Management Institute
12/31/2017
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL1850 R10 COI HV Accordion CI HVHZ.pdf
Standard
TAS 201, 202, 203
Method 1 Option D
Year
1994
https://floridabuilding.org/pr/pr_app fi.aspx?param=wGEVXQwtDgs9%2f"/o2ftCOhpJQoeIShOCDrfdBDP,ft3tFpHgLNr4gNQIpQg%3d%3d 1/2
3/27/2017
1
Florida Building Code Online
Date Submitted
04/26/2015
Date Validated
04/28/2015
Date Pending FPC Approval
04/29/2015
Date Approved
06/23/2015
Summary of Products
FL # Model, Number or Name
Description
1850.1 Bertha HV Accordion -Blade 3
Extruded aluminum blades folded together thru knuckles and
(HVHZ) Drawing# 15-081
retained by tracks to provide hurricane protection.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL1850 R10 II A.S.S.A. INC. drawing DRWG.15-081.pdf
Verified By: American Test Lab of South Florida Inc.
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large Missile Level "D". Max span is 12'-7" for 35 psf
FL1850 R10 AE A.S.S.A. INC. P.E.R DRWG.15-081.Ddf
Created by Independent Third Party: Yes
positive ASD load and 13'-0" for 35 psf negative ASD load for
one specific condition shown in span tables. See additional
loads and spans on engineered drawings.
1850.2
Bertha HV Accordion Shutter
Extruded aluminum interlocking blades retained by tracks
(Combo) - HVHZ - Drawing#15-079
(top and bottom) for storm protection
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL1850 R10 II A.S.S.A. INC. DRWG.15-079.pdf
Approved for use outside HVHZ: Yes
Verified By: American Test Lab of South Florida Inc.
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large Missile Level "D". Max. span is 13'-2" for 30
FL1850 R10 AE A.S.S.A. INC. P.E.R. DRWG.15-079.pdf
Created by Independent Third Party: Yes
psf positive ASD load w/o window blade, 16'-0" for 30 psf
negative ASD load for HV1 blade w/o window blade for
conditions indicated on schedule #1, sheet 12. And 15'-5" for
30 psf positive ASD load w/o window blade and 18'-0 for 30
psf negative ASD load for HV2 blade w/o window blade. See
sheets number 12, 25, 28 and 28A of installation drawings for
otherspans and pressures.
1850.3
Bertha HV Accordion Shutter - Blade
Extruded aluminum interlocking blades retained by tracks
1 Only (HVHZ) - Drwg# 15-080
(top and bottom) for storm protection
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL1850 R10 II A.S.S.A. INC. Drawing DRWG.15-080.pdf
Verified By: American Test Lab of South Florida Inc.
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large missile level "D". Max. span is 16'-0" and
FL1850 R10 AE A.S.S.A. INC. P.E.R DRWG.15-080.odf
Created by Independent Third Party: Yes
14'-9" for 30 psf ASD negative load depending on
centermates and locking rod configuration for the HV1 blade,
8'-0" for +64, -72 psf load for HV blade for Keystone
mountings 7'-0" for +75, -75 psf for metals stud mountings
and 8'-0" for 110 psf. for HV1 and HV1A working in unison.
See sheets 7, 11, 20 and 19 respectively of installation
drawings for other spans and pressures.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
;;: *1 zGhecY
Credit Card
Safe
Sectir1
https://fl oridabui I di ng.org/pr/pr_app_dtl .aspx?param=wGE\/XQwtDgs9%2f /o2ftCOhpJQoe[ShOC D rfdBD Plfc3tFpH gLN r4gN QI pQg%3d%3d 2/2