Product Approval Menu > Product or Application Search > Application List > Application Detail
s �s �� FL # FL1850-R10
"" " Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory CAccordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
y` Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Walter A. Tillit, Jr., P.E.
PE -44167
National Accreditation and Management Institute
12/31/2017
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL1850 R10 COI HV Accordion CI HVHZ.pdf
Standard
TAS 201, 202, 203
Method 1 Option D
Year
1994
https://floridabuilding.org/pr/pr_app fi.aspx?param=wGEVXQwtDgs9%2f"/o2ftCOhpJQoeIShOCDrfdBDP,ft3tFpHgLNr4gNQIpQg%3d%3d 1/2
3/27/2017
1
Florida Building Code Online
Date Submitted
04/26/2015
Date Validated
04/28/2015
Date Pending FPC Approval
04/29/2015
Date Approved
06/23/2015
Summary of Products
FL # Model, Number or Name
Description
1850.1 Bertha HV Accordion -Blade 3
Extruded aluminum blades folded together thru knuckles and
(HVHZ) Drawing# 15-081
retained by tracks to provide hurricane protection.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL1850 R10 II A.S.S.A. INC. drawing DRWG.15-081.pdf
Verified By: American Test Lab of South Florida Inc.
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large Missile Level "D". Max span is 12'-7" for 35 psf
FL1850 R10 AE A.S.S.A. INC. P.E.R DRWG.15-081.Ddf
Created by Independent Third Party: Yes
positive ASD load and 13'-0" for 35 psf negative ASD load for
one specific condition shown in span tables. See additional
loads and spans on engineered drawings.
1850.2
Bertha HV Accordion Shutter
Extruded aluminum interlocking blades retained by tracks
(Combo) - HVHZ - Drawing#15-079
(top and bottom) for storm protection
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL1850 R10 II A.S.S.A. INC. DRWG.15-079.pdf
Approved for use outside HVHZ: Yes
Verified By: American Test Lab of South Florida Inc.
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large Missile Level "D". Max. span is 13'-2" for 30
FL1850 R10 AE A.S.S.A. INC. P.E.R. DRWG.15-079.pdf
Created by Independent Third Party: Yes
psf positive ASD load w/o window blade, 16'-0" for 30 psf
negative ASD load for HV1 blade w/o window blade for
conditions indicated on schedule #1, sheet 12. And 15'-5" for
30 psf positive ASD load w/o window blade and 18'-0 for 30
psf negative ASD load for HV2 blade w/o window blade. See
sheets number 12, 25, 28 and 28A of installation drawings for
otherspans and pressures.
1850.3
Bertha HV Accordion Shutter - Blade
Extruded aluminum interlocking blades retained by tracks
1 Only (HVHZ) - Drwg# 15-080
(top and bottom) for storm protection
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL1850 R10 II A.S.S.A. INC. Drawing DRWG.15-080.pdf
Verified By: American Test Lab of South Florida Inc.
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Large missile level "D". Max. span is 16'-0" and
FL1850 R10 AE A.S.S.A. INC. P.E.R DRWG.15-080.odf
Created by Independent Third Party: Yes
14'-9" for 30 psf ASD negative load depending on
centermates and locking rod configuration for the HV1 blade,
8'-0" for +64, -72 psf load for HV blade for Keystone
mountings 7'-0" for +75, -75 psf for metals stud mountings
and 8'-0" for 110 psf. for HV1 and HV1A working in unison.
See sheets 7, 11, 20 and 19 respectively of installation
drawings for other spans and pressures.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
;;: *1 zGhecY
Credit Card
Safe
Sectir1
https://fl oridabui I di ng.org/pr/pr_app_dtl .aspx?param=wGE\/XQwtDgs9%2f /o2ftCOhpJQoe[ShOC D rfdBD Plfc3tFpH gLN r4gN QI pQg%3d%3d 2/2