Loading...
HomeMy WebLinkAboutProduct Approval I � I ` I EXTERIOR RESEARCH Ift DESIGN,LLC. I Certificate of Authorization#9503 �I V�� 1 1 ICR® 353 CHRISTIAN STREET,UNIT#13 EOXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1121 1 Campus Drive I FL10124-1119 Parsippany,NJ 07054 Date of Issuance:01/03/2008 Revision 21:08/26/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code; Residential Volume. The products described herein have been evaluated for compliance with the 5e'Edition (201.4) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that rel,'ite to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words"Trinity IERD Evaluated"may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be dlone in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the riser by.,the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: -E Robertl.M.Nieminen P.E. �r.,�Sn OVaL l��`' 'Theia.sbnlleseal apGearirgwatho aurrsedbypobenNleminen, i., mi E' rr trttra PE.an 08)26/IOI6.i7hisdoesnotserveasanelectronitallysgned Florida Registration No.59166,Florida DCA ANf19&3 t ' daoument.Signed;sealed hardcaples have boon transmitted to the Product Approval Administratarand to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire,a financial interest Wany company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company,manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen,P.E.are,in any way;the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or;design guidance unless retained specifically for that purpose. I I i I i %J TRINITY ERS ROOFING SYSTEMS EVALUATION: 1. SCOPE: j Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF, have demonstratedlcompliance with the following sections of the Florida Building Code and Florida Building Code, Residential,Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2009 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: EntityExamination Reference Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact,Resistant;IR 01/13/2012 PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/26D2 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 D5/25/2OD5 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL(TST 1740) ASTM D3462 OINK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 OSNK27924 02/10/2006 UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/0512006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 Exterior Research and Design,LLC. Evaluation Report 01506:01.08-R21 Certificate of AuthanIzation#9S03 FL10124-R19 Revision 21:08/26/2016 Page 2 of 6 'I . a -,J TR NNW ER® ' Enft Examination goterence Date UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM 03161,07158,03462 09NK06547 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 1OCA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010 UL(TST 1740) ASTM D3462 IOCA07264 I 05/27/2010 UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010 UL(TST 1740) ASTM D3161,07158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM 133161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA05100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCAS3934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 j 12/09/2011 UL,I.I.C.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 D2/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,I.I.C.(TST 9628) ASTM D3161 13CA37934 D8102/2013 UL,LLC.(TST 9628) ASTM 133161,D7158,D3462 4786875675 i 07/17/2015 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 4787434542 1 05/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,!AL 12/28/2015 UL,LLC.(QUA 9625) Quality Control Inspection Report,R2,1,Myerstown,PA j 02/23/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 02/26/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 03/02/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shafter,;CA 02/18/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 1 02/24/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 02/09/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Version,IN 02/09/2016 UL,LLC.(QUA9625) -Quality Control Inspection Report,R21,Baltimore,MD 03/01/2016 UL,LLC.(QUA 9625) Quality Contras Inspection Report,1121,Tampa,1FL 02/29/2016 UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 02/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 02/03/2016 UL,I.I.C.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 03/03/2016 4. PRODUCT Dies dupiriON: 4.1 Asp halt Shingles: 4.1.1 Marquis® WeatherMax°, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. !' 4.1.2 Camelote, Camelot® II, FortitudeTM, GlenwoodTM'. Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShieldTM, Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldTM II,Timberline®Natural Shadow®,Timberline HD®,Timberline®Cool Series°,Timberline Ultra HD®and Woodland®are fiberglass reinforced,laminated asphalt roof,shingles.' 4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge° IR Impact-Resistant Ridge,'Cap Shingles, Seal-A-Ridge® ArmorShieldTM Ridge Cap Shingles and Timbertex®Premium Ridge Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. I Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R21 Certtykate of Authariratlon#9503 FL10124-R39 j Revision 21:08/26/2016 i Page 3 of 6 i i i i TRINITY I ERD 4.3 Accessory.Starter Strips ; 4.3.1 Pro-Start®Eave/Rake Starter Strip Shingles and WeatherBlocker'Premium Eave/Rake;Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strip,nominal 9-Inch x 33 ft roll,for use with asphalt.shingles with exposure of 6- inch or less. 4.3.3 StarterMatch'Sharter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch' are installed as the second starter for Grand CanyonO and Grand Sequoia®series installations. S. UmITATIONS: i 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically fol•that purpiose. 5.2 This Evaluation Report is not for use in the HVH2. 5.3 Fire Classification is not part of this Evaluation Report; refer to current iApproved Roofing Materials Directory for fire ratings of this product. 5_4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating tke shingles are acceptable for use in all wind zones up to Vw=150 mph(V„it=194 mph). Refer to Section 6:for installation requirements to meet this wind rating. 5.4.2 The GAF hip&ridge shingles noted in Section 4.2 are Classified in accordance with,FBC Tables 1507.2.7.1 and R90S.2.6.1 to ASTM D3161,Class F,indicating the shingles are aeceptableifor use in all wind zones up to Va,d=150 mph(V.it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design:iprofessional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or 11905.2.3. 6.2 Starter Shingles or Starter Strip: 6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium!Eave/Rake Starter Strip Shingles and QuickStart Peel&Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: I 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's currePit published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2. or R905.2, with the following exceptions: D Camelot,Camelot 11,Grand Canyon,Grand Sequoia,Grand Sequoia IR,Grand Sequoia ArmorShield,and Woodland require minimum five(5)nails per shingle. D Slateline requires minimum six(6)nails per shingle. ' I Exterior Research and Design,LLC. Evpluation;Report 01506.01.08-R21 Cercyromte ofAuthorhatron A9503 FL10124-R19 Revision 21:08/26/2016 Page 4 of 6 i i TRINITY ERD 1 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements,Iut not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip&Ridge Shingles: I � 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles,Seal-A-Ridge IR Impact-Resistant' Ridge Cap Shingles and Seal- A-Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturers current published instructions with a minimum two(2)nails,minimum 3/8-inch head diameter,per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant". 11.5` Sealant —F—(292 mm) 1° Sellante (25 mm) (25 mm) Enduitd'ManchOM I d �-.�•g'�r J � I k � X (305 mm) Nail Glavo X65/1 4 mm) clover I 1 i (305 mm) I 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply withi l the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch hesid diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing-and Flashing Sealant. 14fr` Sal (? ro1M} ;25 rnm E�luii d'ita�t+dlhf fLH Cin {S05 trim) {Baer (2n rump .i I I 305 awk) j 6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterlor Research and Design,LLC Evaluation Report 01506.01.08-R21 Certl/kate ojAudwr&atloe 49503 FL10124-R19 Revision 21:08126/2016 j Page 5 of 6 I j I � � i - Q�"JTKINITYJERD 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 11 1 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required'classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority having Jurisdiction in order to properly evaluate the installation of this product. I 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61620-3 Qct requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(847)664-3281 - END OF EVALUATION REPORT- i I I i I I i I , I i I Exterior Research and Design,LLC. Evaluation,Report 01506.01.08-1121 cerdflicate of Authorization#9503 FL10124-R19 Revision 21:08/26/2016 j Page 6 of 6 I i I ®. EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 j 353 CHRISTIAN STREET,UNIT#13 IERD i OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-R5 PO Box 70 FL16048-R5 Rutherford,NJ 07070 Date of Issuance:10/25/2012 (800)516-1485 Revision 5: 06/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5`h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments I I I LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named produdt(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity i ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity'ERD Eva Iluated'; may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it'shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the,user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: ts)ttatrerr„rr� j tP. c1:g:•rG• The • '..1C.r::.• . Robert J.M.Nieminen P.E. riFS "''�T P.E.on 06/12ile sealapThisdg snotshorizedbyRobertNieminen, r �•,;bJ�„��� `s'�� P.E.on 06/12/2017.This does not serve as an electronically signed Florida Registration No.59166,Florida DG4 ANE1983 � document.Signed,sealed harticopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it'evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. I 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I I i I i I ' I TRINITY=ERD ROOFING COMPONENT EVALUATION: i 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2004 1504.3.1 Wind Uplift UL 1897 2004 1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.5.3,1507.7.3 1504.6 Accelerated Weathering ASTM G155 2005 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: jEnti Examination Reference Date ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties 540540.11.13 11/19/2013 ERD(TST6049) Physical Properties 540540.03.14 03/26/2014 ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014 ERD(TST6049) Physical Properties 543530.05.14 05/28/2014 ERD(TST6049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 09/04/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. I 4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester;''fabric surfaced, SBS modified bitumen roof underlayment 4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat 'einforced, film-surfaced, SBS modified bitumen roof underlayment. i S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that pi rpose. 5.2 This Evaluation Report is not for use in the HVHZ. i ' Exterior Research and Design,LLC. Evaluation Report A42960.10.12-115 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL16048-RS Tri-Built Materials Group,LLC. Revision 5:06/12/2017 Page 2 of 6 i a TRINITYER® I 5.3 Fire Classification is not part of this Evaluation Report; refer to current�Approved Roofing Materials Directory for fire ratings of this product. 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a rbquest'may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are as follows: TABLE 1 ROOF COVER OPTIONS j, Underlayment Asphalt Nail-On Tile Foam-On Tile Metal i„ Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No rYes Yes Underlayment Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Tri-Built S/A HT TU Underlayment with ICP Adhesives "Polyset AH-160" (FL6332) or Dow Chemical "TileBondTm Roof Tile Adhesive"(FL717) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlaymgnt or Tri-Built Smooth HT S/A j Underlayment applied to: ➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed'OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. I While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. i. 5.6.2 Bond-to-Insulation: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tki-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing oif the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. I I I i Exterior Research and Design,LLC. Evaluation Report A42960.10.12-RS Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL16048-RS Tri-Built Materials Group,LLC. Revision 5:06/12/2017 Page 3 of 6 i i I ERD 5.6.3 Bond to MechanicallV Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications:1 FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by2 (the,2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER I ' Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered' 5.6.4.3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority HavingiJurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush' with the surface. All sharp splinters and wood projections shall be removed/sanded.; Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-laps. 5.6.4.4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-in6h laps and 6-inch o.c.in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. 5.7 Exposure Limitations: 5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation 5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. Exterior Research and Design,I.I.C. i Evaluation Report A42960.10.12-RS Certificate of Authorization 119503 FBC NON-HVHZ EVALUATION FL16048-RS � Tri-Built Materials Group,LLC. Revision 5:06/12/2017 Page 4 of 6 i° TRINITYIERD Ai 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordancejwith TRI:'-BUILTiMaterials Group, LLC published installation requirements subject to the Limitations set forth,iin Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate,(if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlavment,Tri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A Underlavment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970;underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. ,i 6.3.2 Non-Tile applications: While priming is optional,TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll,broom or hand-press the membrane into placelto achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water,;'rVertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with TRI-BUILT Materials Group,LLC requirements. j i When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release,paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TU Underlavment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual dhd Table 1 herein, using the ,L instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). ; I Tile shall be loaded and staged in a manner that prevents ;tile slippage and/or damage to the underlayment. Tri-Built S/A HT TU Underlayment has met the tile slippage test requirements specified in FRSA/TRI April 2012 (04-12) up to a 10-tile stack to a maximum roof pitch of 6:12 for flattiles and 5:12 for lugged tiles. Lugged tiles staged at pitch>5:12 may use alternate staging method(bottom 2-tilelstack shall be inverted, followed by 8 tiles high on slope,as shown below). I j i � I 'i Exterior Research and Design,LLC. I Evaluation Report A42960.10.12-115 Certificate of Authorization 119503 FBC NON-HVHZ EVALUATION FL16048-RS Tri-Built Materials Group,LLC. Revision 5:06/12/2017 Page 5 of 6 I. , I, I ;I, I I w I TRIM" ER® 4. 7 Figure 1: Alternate Staging Method I Alternatively, at roof slopes greater than these limitations, all tiles'.shall be loaded'onto a nominal 1"x 2" horizontal batten to prevent slippage or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N=3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- I ' I I I I I i I i I i Exterior Research and Design,LLC. 'Evaluation Report A42960.10.12-R5 Certificate of Authorization#9503 FBC NON-HVH2 EVALUATION FL16048-RS Tri-Built Materials Group,U.C. Revision 5:06/12/2017 Page 6 of 6 it