Loading...
HomeMy WebLinkAboutProduct Approval (2) 11/3/2017 Florida Building Code Online �a td"f V� .- 9➢ 4.{ b�.tt p"�r�� 1 �� tGt t � � � _ 2 BCIS Home Login User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map I Links Search d, b a , Product Approval USER:Public User r Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL14850-R2 Application Type Revision Code Version 2014 Application Status Approved Comments I' Archived �I Product Manufacturer Custom Window System's Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352) 368-6922 Ext 291 ekoss@cws.cc I ii Quality Assurance Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Category Exterior Doors I Subcategory Swinging Exterior Door,Assemblies Compliance Method Evaluation Report from'a Florida Registered Architect or a Licensed Florida Professional Engineer ' Evaluation Report-Hardcopy Received I Florida Engineer or Architect Name who developed Lucas Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich, PE j6 Validation Checklist- Hardcopy Received Certificate of Independence FL14850 R2 COI EvalRep CWS-6418(FD-8750. IMP).pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A-440 2005 ASTM E1300-04 2004 ASTM E1886-05 2005 ASTM E1996-05 2005 PA TAS/201/202/203 1994 Equivalence of Product Standards https://www.floridabLilding.orglpr/pr app U.aspx?param=wGEVXQwtDquHlFzfePouW7oGhYGF3pWxjAQp/o2f%2fSOvrM!4)tRGwKNsNoA%3dp/o3d 1/2 11/312017 Florida Building Code Online Certified By Sections from the Code i Product Approval Method Method 1 Option D Date Submitted 04/20/2015 Date Validated 04/23/2015 Date Pending FBC Approval 04/25/2015 Date Approved 06/23/2015 Date Revised 09/28/2017 Summary of Products FL# Model,Number or Name Description 14850.1 FD-8750, Impact. FD-8750 French Door, SD-8700 Swing Door, SLT 8710 Sidelite, Impact. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14850 R2 II CWS-6418(FD-8750. IMP).pdf Approved for use outside HVHZ:Yes Verified By: Lucas Turner 582b1 Impact Resistant:Yes Created by Independent Thirdl Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: Large Missile French Door w/Sidelights, Max. French FL14850 R2 AE DuPont PVB NOA 13-0129 27.pdf Door 6'x 8', Max. Single Door Tx 8', Max. Sidelight Y x 8', FL14850 R2 lAE DuPont SGP NOA 11-0624 02.Ddf DP+/-70 psf. Glass complies to ASTM E1300-04. FL14850 R2.1AE EvaIReD CWS-6416(FD-8750. IMP).pdf FL14850 R2'AE Ouanex (Mik�on) NOA 12-1017 02.Ddf Created by Independent Third Party: Yes Back Next ' i Contact Us::2601 Blair Stone Road.Tallahassee FL 323W Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a putiiic-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: W-71 i Credit Card Safe haps://www.floridabLiiding.org/or/pr app o.aspx?param=wGEVXQwtDquHlFzfePouW7oGhYGF3pWxjAQg/o2f%2fSOvrMi4XRGwKNSNOAg/o3d%3d 212 GENERAL NOTES: o8�] /�/f��f SWING DOOR & SIDELITE - LARGE MISSILE IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED '�""� TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT, WINDOW SYSTEMS EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE. S RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 79" MAX.FRENCH DOOR WIDTH 36 3/16" MAX IN ASTM E 1996 PER THE FBC. WWW.CWS.CC SIDELITE WIDTH 2.GLAZING OPTIONS:(SEE SHEET 4) 37 5/8' MAX 33 5/8"MAX. 8700/10/50 PVC PANEL WIDTH PANEL WIDTH 3.CONFIGURATIONS:SINGLE OUTSWING,SINGLE OUTSWING 26 5/8" 22 5/8" w/SIDELITE(S),FRENCH DOOR(S),FRENCH DOOR(S) SWING DOOR GLASS DLO -- - GLASS DLO_ D - w/SIDELITE(S),SIDELITE NOT ATTACHED. IMPACT l I 4.LOCK OPTIONS: I UP TO 6'8": _ -- -- -- 97" A.DOUBLE BORE w/TWO(2)INTERIOR FLUSH BOLTS. 97- UNIT - - = - - - MAX. - HANDLE SET @_36" yr o Q MAX UNIT B.MORTISE LOCK w/TWO(2)INTERIOR FLUSH BOLTS.' o o UNIT E HEIGHT HANDLE SET @ 34" HEIGHT E C.MULTIPOINT(4 PT.) 2 pW -C C D 94 5/8" HANDLE SET @ 34- MAX ¢ m M 3116" 1 12 MAX, ABOVE 6'8":- W MAX- X X FLUSH BOLT E I C PANEL A.MULTIPOINT(5 PT.) v v Z PANEL INACTIVE PANEL HEIGHT HANDLE SET @ 34" LL m m O HEIGHT :! o D 8 /16" 11 83 5/8" 5.DESIGN PRESSURE RATING: N N Z w GLASS GLASS -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND w w O DLO SEE DLO GLASS TABLES ASTM E-1300-04. IL a a NOTE 4 I POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER ❑ ❑ I INFILTRATION TEST PRESSURE AND GLASS TABLES a a U ASTM E-1300-04. ❑ ❑ I 40" MAX.SINGLE o A In DOOR WIDTH D C 6.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED 11 37 5/8' MAX 12 IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 11-12 FOR ANCHOR m ¢ Z PANEL WIDTH SIDELITE DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD FRENCH DOOR 26 5/8" ANCHOR CALCULATIONS. 0 0 �����°�ni�4� GLASS DLO A 7-PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE •J`�p`'P'0 S N,3' 81/2'. NOTE: NOT REQUIRED. :.`JG,•'• R '•.L�'� HINGE SPACINGS ARE 8-1/2" .v; No 56201 :11 97" j FROM ENDS AND 20"MAX.O.C. 8.ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. PANELS MAX- 20' FOR 81"TO 97"UNIT HEIGHT. ARE PROCESSED AND ASSEMBLED VIA TIE ROD. UNIT 'S'P STATE OF PQ HEGHT 9.SERIES/MODEL DESIGNATION SD-8700,FD-8750,SLT-8710. '+p•, �u: 10.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: �R DPU\`•` 953/3/16" X i B X=OPERABLE SASH,O-FIXED SASH ����iS��NA����••`` PANEL B 11.SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR HEIGHT LOCATION. 4/18/2015 84 3/16" 17 12.INTERIOR FLUSH BOLTS ON ACTIVE PANEL TO BE ENGAGED PRIOR TO LUCAS A.TURNER,P.E. GLASS SEE SEVERE WEATHER. FL PE#58201 DLO NOTE 41239 JABARA AVE. 13.QUALIFIED ALTERNATIVE T/DEADBOLT HARDWARE IS NORTH PORT,FL 34288 81/2" GRADE 2 BY PAMEX AND DELANY.LANY. PH.941-380-1574 A 14.MAX.PANEL WIDTHS APPLY TO ALL CONFIGURATIONS,MULLED OR SHEET DESCRIPTION: NON-MULLED UNITS. GENERAL NOTES AND TABLE OF CONTENTS SINGLE DOOR ELEVATIONS GENERAL NOTES&ELEVATIONS........1TYPE MAX. PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING Turner Lucas A. DRAWN DATE: GLAZING DETAILS....................................4 ADE 09/08/11 SECTION VIEWS....................................5-7SINGLE 2015-04-22 BOM............................................................8 37-5/8"x 95-3/16" 10:26-04:00 DWG#: REV.: EXTRUSIONS.............................................9 FRENCH +/-70 PSF LARGE MISSILE IMPACT CWS-641 B ANCHOR SCHEDULE&NOTES..............10 INSTALLATION DETAILS....................11-12 SIDELITE 33-5/8"x 94-5/8" scALE: SHEET 1:35 1 OF 12 151 3/8"MAX.UNIT WIDTH a2gom.�((�l 36 3/16"MAX. 79" WINDOW SYSTEMS IBJ SIDELITE WIDTH MAX.FRENCH DOOR WIDTH 1900 SW 44TH AVE. OCALA,FLORIDA 34474 335/8" 375/8" MAX. WWW.CWS.CC PANEL WIDTH PANEL WIDTH 8700/10/50 PVC 97" SWING DOOR UNIT I - UNIT - - - - -- - - IMPACT - HEIGHT 94 5/8" - 95 3/16" SIDELITE X - X O PANEL HEIGHT HEIGHT FLUSH Y BOLT O " 83 5/8" LU ON 84 3/16"._ w ¢ m SIDELITE LNOTE4 EE INACTIVE = DOOR PANEL - - - - - -_ - - -- - - - GLASS GLASS c� c� Z DLO T1 DLO m m O a o (n N N Z W W W O 22 5/8" 26 5/8" a EL a~ GLASS DLO GLASS DLO W ¢ FRENCH DOOR w/SIDELITES U m LU an > o m ¢ ZO ��unnurr 115 3/16"MAX.UNIT WIDTH 76 3/16"MAX.UNIT WIDTH 4%'0,,`�,P:Np E N.• TG�k,i� 36 3/16"MAX. 79" ��VPS•` SF•;Qy.� SIDELITE WIDTH MAX.FRENCH DOOR WIDTH 36 3/16"MAX DO MAX.SINGLE v: No 58201 •'•,� SIDELITE WIDTH DOOR WIDTH • 33 5/8"MAX, 37 5/8" MAX. 33 5/B"MAX. 37 5/8" MAX. * �' PANEL WIDTH DOOR WIDTH PANEL WIDTH DOOR WIDTH :9 STATE OF :�+C �i CC •� MAX. MAX. UNIT UNIT HEIGHT y� HEIGHT 4/18/2015 94 5/8" 95 3/16" 94 518" PANEL LUCAS A.TURNER,P.E. SIDELITE O X X 95 3116" SIDELITE 0 X HEIGHT FL PE#58201 HEIGHT PANEL HEIGHT HEIGHT 1239 JABARA AVE. 83 5!8" BOLT 83 NORTH PORT,FL 34288 SIDELITE ON &43/16• 835/8" 843116' PH.941-380-1574 GLASS SEE INACTIVE SIDELITE DOOR DLO NOTE 4 DOOR SEE SHEET DESCRIPTION: PANEL GLASS GLASS NOTE4 GLASS SHT 1 DLO DLO SHT 1 DLO GENERAL NOTES AND ELEVATIONS DRAWN BY: DATE: 22 5/8" 26 518" 22 518" 26 5/8" ADE 09/08/11 GLASS DLO GLASS DLO GLASS DLO GLASS DLO DWG#: REV.: SINGLE DOOR w/SIDELITE CWS-641 B FRENCH DOOR w/SIDLITE SCALE: SHEET 1:35 2 OF 12 40"MAX.SINGLE 79" MAX.FRENCH DOOR WIDTH 36 3/16"MAX. �!l�6ylGl!//r • DOOR WIDTH SIDELITE WIDTH WINDOW SYSTEMS 37 5/8" MAX. 37 5/8" MAX. 33 5/8" MAX. 1900 SW 44TH AVE. PANEL WIDTH PANEL WIDTH PANEL WIDTH OCALA,FLORIDA 34474 26 5/8" 26 5/8" 22 5/8" W W W C WS.CC GLASS DLO GLASS DLO GLASS DLO 7- 81/2" NOTE:HINGE SPACINGS i 8700/10/50 PVC 81" FLUSH ARE 8-1/2"FROM 81" FLUSH 81" SWING DOOR MAX. _ _ BOLT 215/16.• ENDS AND 21-5/16" MAX BOLT MAX. IMPACT UNIT MAX.O.C.UP TO HEIGHT HEIGHT - HEIGHT 81"UNIT HEIGHT. 79 3/16" 78 5/8" � 79 3/16" PANEL PANEL - PANEL - - -=-X - ` _ = HEIGHT - X4 X_ -HEIGHT _ 0 d W HEIGHT - o. .1683116" 686116' 67 5/8" GLASS SEE GLASSL GLASS Y w DLO-_ NOTE 4 DLO DLO w ¢ m SHT 1 _ - co 81/2' LL LL p SINGLE DOOR FRENCH DOOR SIDELITE $ $ z > w w a a a U U W O O ❑ f� Q Z , '%l►{Illlllll�l, 1513/8"MAX UNIT WIDTH 112 3/8"MAX UNIT WIDTH �`Q5 p• 0'E N'S'T"/Q��i� 36 3/16" MAX 79"MAX.FRENCH DOOR WIDTH 363/16"MAX 40"MAX.SINGLE V F'•,y SIDELITE WIDTH SIDELITE WIDTH DOOR WIDTH No 58201 33 5/8" MAX. 37 5/8" MAX. 33 5/8" MAX. 37 5/8" MAX. PANEL WIDTH PANEL WIDTH PANEL WIDTH PANEL WIDTH - 9� STATE OF .w� 81" FLUSH MAX FLUSH ���i�F`5;�.�O R ulx* MAX. BOLT UNIT BOLT UNIT HEIGHT 79 3/16" lllllllllots, t HEIGHT 79 3/16" DOOR 78 5/8" DOOR 78 5/8" PANEL Z� PANEL SIDELITE O �( X � HEIGHT SIDELITE � X � HEIGHT 4/1812015 HEIGHT HEIGHT 67 5/8" 68 3/16" 68 3/16" LUCAS A TURNER,P.E. SIDELITE DOOR 67 5/8" DOOR FL PE#58201 SEE GLASS SIDELITE 1239 JABARA AVE. DLO NOTE 4 DLO GLASS pLOSS NORTH PORT,FL 34288 SHT1 DLO PH.941-380-1574 SHEET DESCRIPTION: 225/8- 26 5/8" 22 5/8" 26 5/8" GENERAL NOTES AND GLASS DLO GLASS DLO GLASS DLO GLASS DLO ELEVATIONS DRAWN BY: DATE: FRENCH DOOR w/SIDELITES SINGLE DOOR w/SIDELITES ADE 09/08/11 DWG 4: REV.: CWS-641 B SCALE` SHEET 1:35 3 OF 12 GLASS TYPES a0(G(j/V/� MAX.UNIT WINDOW SYSTEMS HEIGHT SIDELITE SINGLE I FRENCH 1900 SW 44TH AVE. 1"OVERALL 1"OVERALL 81" A A A OCALA,FLORIDA 34474 97" B B B Www.Cws.cc 17 3/16"TEMPERED 3/16"TEMPERED 5/16"AIRSPACE 3/8'AIRSPACE 8700/10/50 PVC 1/2" LAMINATED 7/16"LAMINATED SWING DOOR 3/16'ANNEALED 3/18"ANNEALED — IMPACT 105 DUPONT PVB INTERLAYER .080 SENTRY GLASS IONOPLAST INTERLAYER � 3/16"ANNEALED _ _ -- -_--- -- _-__ _--_ 3/16"ANNEALED- - - - -- - -- --- - - - --= -- - _ _ - - - - -- - - opo - SIKA-SIKAFLEX 552 or SIKA-SIKAFLEX 552 or 11 HENKEL-PURFECT GLAZE"H" {J 11 HENKEL-PURFECT GLAZE"H" w ¢ m U U Z m m 3/4"GLASS BITE 3/4'GLASS BITE y 3 3N N Z W ¢ ¢ O ¢:L6iU ¢ 10 10 a a a 811EE U W IL1 1on 0 2 ,��0� ,011111111111r," V2 .......... B N�G,Qy v. No 58201 :1S --a• •aC 9� STATE OF :w' ..O p SOP•\'c�� Si�NA� zz 4/18/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS GLASS TYPE A GLASS TYPE B DRAWN BY: DATE: ADE 09/08/11 DWG#: REV.: CWS-641 B scALE: SHEET 1:1 4 OF 12 INTERIOR WINDOW SYSTEMS 1900 SW 44TH AVE. 68 7 74 38 4 46 61 68 7 OCALA,FLORIDA 34474 W W W.CWS.CC 1 sa 35 8700/10/50 PVC SWING DOOR s3 - IMPACT 19 1 35 - 35 - - 19 64 ¢ m lJ m 4 6 56 58 41 0 3 1 4 18 3 4 44 6 N N Z > w w w O � a a a UR u�icr ul 0 o m SECTION VIEW B-B > > m ¢ Z 01WuirRi�� INTERIOR •��,,, ,`'% Po E N ' rG,.��i 60 38 3031 `�JGQ,�'�� SF• �',� v t No 58201 :-P 3 i1 %9'; STATE OF .•W� ALTERNATE 1 ALTERNATE 2 110. • '�,�. P��c •�OR19 � a 4/18/2016 47 ZZ 5 7 MORTISE LOCK w/FLUSH BOLT 32 MULTIPOINT LOCK LUC FL PE#58201 P.E. 9 1239 JABARA AVE. 0 59 NOT 9401 T,15288 14 56 SHEET DESCRIPTION: 69 SECTION VIEWS 6 SINGLE DOOR 55 ITEMS NOT SHOWN FOR CLARITY: DRAWN BY., DATE: 56 35 051 10-12,13,15-17,22,43,48,54,57-58 ADE 09/08/11 DWG#: REV.: ITEMS NOT USED IN VERSION SHOWN: CWS 541 B SECTION VIEW A-A 2-3,8-9,15-16,25-28,30-34,36-40,43,52-53,60,62,65-66,72,76 SCALE: SHEET 1:2 5 OF 12 WINDOW WIidDOVV SYSTEP9S 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.0 W S.CC INTERIOR 8700/10/50 PVC SWING DOOR - - - _ _ _ _ _ IMPACT 7 61 35 33 3 35 65 41 66 14 14 34 -3 61 — 68 P7 " Y W 20 m v U Z U.I m m O cc N N Z W W W O a a w w Q U y 19 23 4 4 71 73 4 30 31 32 66 0 13 35 4 2 3 1 4 1 18 19 23 444 6 m a Z ...punuuq.., SECTION VIEW C-C -41 No 58201 9O STATE OF :141�+ S+ONAi11 �`�C;, zx 4/18/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: SECTION VIEWS FRENCH DOOR DRAWN BY: DATE: NOTE:VERTICAL SECTION SIMILAR ITEMS NOT SHOWN FOR CLARITY: ADE 09/08/11 TO SINGLE DOOR,SEE SHEET 5 10-13,15-17,22,26-28,36-39,43,54,57 _ DWG#: REV.: ITEMS NOT USED IN VERSION SHOWN: CWS-641 B B-9.,15-16,25,40,42,45-46,48,52-53,58,60,74,76 SCALE: SHEET 1:2.5 6 OF 12 aaggon-ug 53 g WINDOW SYSTEMS 53 62 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CW S.CC 8700/10/50 PVC SWING DOOR IMPACT 2 5 42 5 - - -- - - _— w ¢ m 40 19 4 4 4 73 - - 4 .z LL LL SECTION VIEW E-E o Ir 2 O 2 72 a a a w � S SEALANT APPLIED TO c c ' 3 ADJOINING FACES > > o 6 8 1 BYINSTALLER m Q Z INTERIOR �� REW u JOINING DOOR FRAME#10 HEX WASHER HEAD SIDELITE. `4cj,:'��G ENSE GQ2�' 6"FROM TOP AND BOTTOM S-4 t No 58201 P 4 17"MAX.O.C. �9� STATE OF 4/1812015 5 52 �J LUCAS A.TURNER,P.E. 9 SEALANT APPLIED TO #10-24 x 1-3/4"TYPE F FL PE#58201 ADJOINING FACES THRU HINGE INTO SIDELITE AT EACH HINGE. 1239 JABARA AVE. b BY INSTALLER SEE SHEETS 1&3 FOR HINGE SPACING. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: SECTION VIEWS 9 ATTACHED SIDELITE ITEMS NOT SHOWN FOR CLARITY: DRAWN BY: DATE: SECTION VIEW D-D 10-11,16,22,28,43,57 ADE 09/08/11 ITEMS NOT USED IN VERSION SHOWN: DWG#; REV.: 1-3,6-15,17-18,20-21,23-24,26-27,30-39,41,44-46,48-52,54-56,58.61,63-71,74-76 CWS-641 B SCALE: SHEET 1:2 7 OF 12 PARTS LIST PARTS LIST ITEM PART# IDESCRIPTION MATERIAL VENDOR ITEM PART# DESCRIPTION MATERIAL VENDORj/](rv�j� • 1 H-1833 MAIN FRAME,HEAD ALUM KEYMARK 51 P-5131 GASKET,DOOR SILL,BACK FOAM HO PRODUCTS WINDOW SYSTEMS 2 H-1857 ASTRAGAL,INACTIVE,FD,PVC ALUM KEYMARK 52 P-5134 SCREW,#10 X 1-3/4"FLAT SQUARE TYPE F @ HINGE FASTENAL 3 H-1858 ASTRAGAL,ACTIVE,FD,PVC ALUM KEYMARK 53 P-5151 GASKET,SIDELfTE FOAM HO PRODUCTS OCA A,FLORIDA 34474 44TH AVE. 4 H-1860 REINFORCEMENT,VERT. ALUM KEYMARK 54 P-5157 SCREW#10-24 x 1/2",FI Undercut PH,18-SSS @ KEEPER FASTENAL WwW.W W.CW S.CC 5 H-1861 REINFORCEMENT,HORIZ ALUM KEYMARK 55 P-5158 BOTTOM SEAL RUBBER TEAM 6 H-1878 MAIN FRAME,SILL ALUM KEYMARK 56 P-5172 WSTP,.370 X.187,TRI FIN,BLACK ULTRAFAB 7 H-1880 MAINFRAME,JAMB ALUM KEYMARK 57 P-5174 ISCREW#8 X3/4"HEX WASHER HEAD,@ FRAME FASTENAL 8700/10/50 PVC 8 H-1881 MAINFRAME,SIDELITE @ DOOR ALUM KEYMARK 58 P-5186 SCREW#8-32 x 1-1/4"PH,FL MS,SS @ PLUNGER SS FASTENAL SWING DOOR 9 H-1900 MAINFRAME,SIDELITE @ JAMB,HEAD,SILL ALUM KEYMARK 59 S-1783 THRESHOLD,HIGH RISE ALUM KEYMARK 10 P-3039 SETTTING BLOCK,1/8 X1 X2 - - FRANKLOWE 60 S-1784 INSERT,REINFORCEMENT- — ALUM KEYMARK IMPAC_T 11 SIAKFLEX552 or PURFECT GLAZE"H" SIKA-HENKEL 61 S-1806 COVER,JAMB,ANCHOR ALUM KEYMARK 12 P-3503 SCREW#8 X 1/2"PH TRUSS SS @ ASTRAGAL CAP FASTENAL 62 S-1816 COVER,JAMBS,HEAD,SILL,SIDELUE ALUM KEYMARK w —13 - __P_-3511-_SCREW#8_x 5/8."SQ.PAN_TEK @ TIEROD BRKT- FASTENAL 63 S-1817 DRIP CAP ALUM KEYMARK rw 14 P-3587 SCREW#8X1",PH FLAT TEK @ ASTRAGAL,INISERTLOCK FASTENAL - 64 S-1840- COVER,HEAD,-ANCHOR— — ALUM - - KEYMARK - c o._ 15 P-3767 SCREW,#10 X1"HEXHEAD,TEK @ SIDELITE FASTENAL 65 S-1849 INSERT,INACTIVE PNL,LOCK HARDWARE KEYMARK 16 P-4146 SCREW#8 X3/4 PHIL,FLAT SS TEK @ SIDELITE SHIM FASTENAL 66 S-1859 COVER,ASTRAGAL,FD ALUM KEYMARK w 17 P-4278- FUZZY PAD,-.200".x 1.250" _W/ADHESIVE ULTRAFAB 67 S-1864 INSERT,FRONT,BTM ATTACH SILL ALUM KEYMARK w ¢ m 18 P-4522 110 x—11W,PH FLAT,SMS-HINGE @ PANEL FASTENAL 68 S-1865 INSERT,-BACK,BTM ATTACH-SILL- -- ALUM- KEYMARK Z 19 P-4774 WSTP,BULB/LEAFS,PANEL AMESBURY 69 S-1915 BASE,SWEEP ALUM KEYMARK m m p 20 P-4790 FLUSH BOLT,ASSM,TOP/BTM SULLIVAN 70 S-1916 DRIP COVER,SWEEP ALUM KEYMARK a o U) 21 P-4794 SCREW#8 x 5/8"SQ.FLATTEK @ INSERTATTACH FASTENAL 71 1 8.6083 PANEL,TOP/BTM RAIL,SIDES-DOOR PVC MIKRON N N Z 22 P-4802 ALL THREADED ROD(TIE ROD) McMASTER 72 S-6083 PANEL,TOP/BTM RAIL,SIDES-SIDELITE PVC MIKRON w w O cr 23 P-4807 HINGE,GUIDE HOPPE 73 86084 GLAZING BEAD(1" PVC MIKRON c o a 24 P-48wpoo9 HINGE,SET HOPPE 74 H-1888 REINFORCEMENT,VERr.,SINGLE DOOR ALUM KEYMARK w w cc 25 P-4814 WSTP,.50X750 FOLDED BULB SEAL,@ SIDELITE AMESBURY 75 GLASS SEE SHEET4 0 0 26 P-4863 LOCK STRIKE PLATE PADDOCK 76 H-1862 REINFORCEMENT,VERT. ALUM KEYMARK > j o 27 P-4864 RHINO STRIKE PLATE PADDOCK 77 P-4887 IMORTISE LOCK PADDOCK " 28 P-4866 GUIDE,TIE ROD NYLON M&M ¢ z 00 29 P-4871 TIE ROD BRACKET ZINC SULLIVAN ,%,0µuu rpr4 31 P-48W SHOOT BOLT,BOTTOM PADDOCK ��.`VP-4885 SHOOT BOLT,TOP PADDOCK PSyNDFN`SFG;p 32 P-4851 LOCKBAR,INACTIVE,8 FT PADDOCK 32 P-4884 LOCKBAR,MULTI-POINT,5PT,8 FT PADDOCK ��:' No 58201 •:�� 32 P-4901 LOCKBAR,MULTIPOINT,4PT,68 FT PADDOCK = 32 P-4902 LOCKBAR,INACTIVE,68 FT PADDOCK 9Q STATE OF •:�� 33 P-4903 HANDLE SET,ACTIVE PADDOCK 34 P-4905 HANDLE SET,INACTIVE PADDOCK '���F• O R IOP: 35 P-4913 WSTP,.50X50 FOLDED BULB SEAL,@ DOOR SCHELGEL �'��SS�OfvA\. 36 P-4917 CAP,ASTRAGAL,OUTSIDE NYLON M&M 37 P-4918 GUIDE,FLUSH BOLT,INACTIVE PNL M&M XZ 38 P-4922 COVER,INTERIOR,FLUSH BOLT NYLON M&M 39 P-4925 CAP,ASTRAGAL,INSIDE NYLON M&M HEAD SILL 4/18/2015 40 P-4926 SHIM,SIDELITE,DOOR SHIPPING BLOCK NYLON M&M ALL FRAMES ARE MECHANICALLY FASTENED LUCAS A. #RNER,P.E. 41 P-4927 GUIDE,FLUSH BOLT NYLON M&M 58201 42 P-4930 SCREW,#10 X 1-1/4"HEX HEAD TEK @ SIDELITE ATTACH FASTENAL 1239 JABARA AVE. 43 P-4933 NUT,3/8"-16 FLANGED W/SERRATED LIP,SS,@ PANEL McMASTER NORTH PORT,FL 34288 44 P-4934 SCREW,#12-24 X1/2",PH FLAT,MS,@ HINGE FASTENAL PH.941-380-1574 45 P-4936 DOOR KNOB,ACTIVE PANEL • DELANY SHEET DESCRIPTION: 46 P-4937 DEADBOLT,ACTIVE PANEL DELANY 47 P-4969 SCREW,#10 X2"REINF.ATTACH. FASTENAL BOM 48 P-4997 STRIKE,DEADBOLT PADDOCK DRAWN BY: DATE: 49 P-5127 SCREW,#12X2",PH PAN,SMS,ANCHOR FASTENAL ADE 09/08/11 50 1 P-5130 I GASKET,DOOR SILL,FRONT FOAM I HO PRODUCTS DWG#: REV.: •ALTERNATE APPROVED LOCKSETS: CWS-641 B PAMEX GRADE 2 LOCKSET AND DEADBOLT SCALE: SHEET 1:1 8 OF 12 " 2 3/4" 4 9/16" 13/4"' —� 2 7/16" 5/8" WINDOW SYSTEMS 1 2 59 1900 SW 44TH AVE. 1 3116" 64 OCALA,FLORIDA 34474 1 7/16" 71 1/16°" 9/� WWW,CWS.CC 1116" 7 1/16" THRESHOLD-1783 HEAD COVER-1840 DOOR HEAD-1833 4 5116" 8700/10/50 PVC 51/2" 5/g• SWING DOOR 1/is^ ��zva^� + __IMPACT 4 9/16" 1/4' 1/4" 61 3/8"" �- 60 5/16 � - - - --- - ,- _ _ _ W - 6 - - - - T. 1/16" FILLE -1784 `r v 1 1/1I 6" REINFORCEMENT•1857 FRAME COVER-1806 R 0 p L_ �1/16" 5/8" Y w .. DOOR SILL-1878 = 2 318" w ¢ m PVC DOOR PANEL-6083 - _ 3 T— 62 11/16" 3 m m O 4 9/16" F- 1 1!2" 3'4" 1/16" R o > I PVC GLAZING BEAD-6084 N N Z W 7 Q SIDELITE COVER-1816 a a a DC 5 4 5/16" Lu cc 0 0 19116" 19 1/8" ¢ a y 1/16" 2 15/16" 1/16" 1/16" 0 1 15/16" 63 DOOR JAMB-1880 314" 5L Ir I I 1-1< ¢ z L- 69 1/16" yµuuUry" DRIP CAP-1817 �PpSORE4y T��4 q 9/16" REINFORCEMENT•1861 REINFORCEMENT-1858 1116" BASE SWEEP-1915 �.1�• � S v. No 58201 :� I- 1 112" 1 1/2"1 ?yF� � ��I 8 I 3/4" : O 21/2" 1 9116"� 0 ,90%• TATE OF i/16" 6 13/16" i�FSi••........... O R 1 215/16" 215!16" 13+16" 1/16 1/16^ isiNA1 lk"% 1/16" 1/16" DRIP COVER-1916 SIDELITE-1881 INSERT,BACK-1865 `y;7- 4/18/2015 L L LUCAS A.TURNER,P.E. 4 9/16" REINFORCEMENT-1860 REINFORCEMENT-1862 FL # 1239 JABARA RA AVE.A NORTH PORT,FL 34288 3" 9/16" PH.941-380'1574 SHEET DESCRIPTION: 21/16" 66 r—� 11--- 'J L 1116" 11 SE `ROI �J U s �OfHF� 1/1 g^ EXTRUSIONS 1116" 1 1/8" 1/8^ INSERT,FRONT-1864 DRAWN BY: DATE: SIDELITE•1900 � ADE 09/08/11 INSERT,INACTIVE PNL-1849 DWG A: REV.: ASTRAGAL COVER-1859 CWS-641 B SCALE: SHEET NOTE:ALL EXTRUSIONS ARE 6063-T6 ALUMINUM 1.2 9 OF 12 � WINDOW SYSTEMS• ANCHOR @ MIDSPAN(TYP.) 4"(TYP.) 1900 SW 44TH AVE. 4" (TYP.) ANCHOR @ MIDSPAN(TYP.) (Y OCALA,FLORIDA 34474 6" MAX.(TYP.) rIF 6"MAX.(TYP.) 4" (TYP WWW.CWS.CC 6" MAX (TYP.) I 6" r 2"(fYP.)'WOOD/METAL MAX.(TYP.) I 4" (TYP 2 (TYP.)'WOOD/METAL A A � � " SEE NOTE 2 SEE NOTE 2 8700/10/50 PVC SWING DOOR -- - IMPACT 17" 17" MAX MAX.O.C. - INSTALLATION- O.C.(TYP) _ w (TYP.) INSTALLATION H _ O X O ANCHOR(TYP.) O X X O ANCHOR(TYP.) c Y (D O7 U U Z m m p 0 0 (n N N Z W I WP 0 IZ a a V V U V F V W o cc SIDELITE DOOR SIDELITE SIDELITE DOOR DOOR SIDELITE a < V m ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FLANGE) > j o m ¢ z CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD AND METAL INSTALLATIONS. DO NOT INSTALL THESE ANCHORS INTO MASONRY. I�IoS �U • � F'.2 v: No 58201 •:�� NOTES: V1.0. STATE OF :ki� 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 4�c�`F4 0 R%0 P �_��, 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 11. 4118/2015 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD LUCAS A.TURNER,P.E. MUST BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE NORTH PORT,FL 34288 MINIMUM SPECIFIED IN TABLE 1,SHEET 11. PH.941-380-1574 SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:4"FOR MASONRY,2-3/16"FOR HINGES(ALL SUBSTRATES),1"FOR WOOD AND METAL. DRAWN BY: DATE: ADE 09/08/11 6.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG#: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 11. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-641 B 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:8 10 OF 12 TYPICAL HEAD ANCHORAGE MIN.EDGE DIST. INTERIOR 1/4"MAX.SHIM � ® SEE TABLE 1 MIN.EMBEDMENT WINDOW SYSTEMS SEE TABLE 1 1900 SW 44TH AVE. CONTINOUS DBL 1/4"BEADS OF SEALANT OCALA,FLORIDA 34474 SUBSTRATE BY OTHERS AROUND PERIMETER AT ALL INDICATED WWW.CWS.CC SEE TABLE 1 MIN.EMBEDMENT POINTS BETWEEN FRAME AND SUBSTRATE SEE TABLE 1 BY INSTALLER. MIN.EDGE DIST. SEE TABLE 1 8700/10/50 PVC F///// // i -A I INSTALLATION ANCHOR SWING DOOR IMPACT PERIMETER SEALANT ^ �1/4° MAX.SHIM SEE TABLE 1 BYINSTALLER INSIDE AND OUT in o o'- CONTINOUS DBL 1/4"BEADS OF SEALANTINSTALLATION ANCHOR HINGE ANCHOR t w AROUND PERIMETER AT ALL INDICATED SEE TABLE 1 SEE TABLE 1 w ¢ m POINTS BETWEEN FRAME AND SUBSTRATE= BY INSTALLER. HINGE MIN.EDGE DIST. Z coSEE TABLE 1 O LL a o y PERIMETER SEALANT BY INSTALLER N N Z W INSIDE AND OUT HINGE MIN.EMBEDMENT w w O DC SUBSTRATE BY OTHERS PERIMETER SEALANT SEE TABLE 1 a a ~a BY INSTALLER SEE TABLEIw INSIDE AND OUT HORIZONTAL SECTION o�s y 11 TYPICAL JAMB/HINGE ANCHORAGE (L wo MIN.EMBEDMENT m ¢ Z SEE TABLE 1 SUBSTRATE BY OTHERS 1puu+rr+� SEE TABLE 1 ,400.P1.1DRE4y TG4�i .��C E NSF• MIN.EDGE DIST. 213116" 8 1/2" (TYP.) �,•'� No 58201 SEE TABLE 1 ANCHORS THRU A VERTICAL SECTION HINGE(TYP.) Z 11 TYPICAL SILL ANCHORAGE '9; STATE OF TABLE 1:APPROVED INSTALLATION FASTENERS ,r,'�i�S'�` R SUBSTRATETYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. "',loop I CONCRETE(2.85 KSI MIN.) 1/4"ELCO ULTRACON 1-3/4" 2.1/2" y y HOLLOW OR GROUT-FILLED CMU(ASTM C-90) 1/4"ELCO ULTRACON 1-1/4" 2-1/2" 215/16"MAX 2X MIN.SOUTHERN PINE(G=0.55) 1/4"ELCO ULTRACON 1-3/8" 7/8" SEE NOTE /1812015 2X MIN.SOUTHERN PINE(G=0.55) #12 WOOD SCREW 1-3/8" 7/8" LUCAS A.TURNER,P.E. 16 GAUGE(0.060')MIN. #12-14 HILT]KW IK-FLEX OR ITW FULL THREAD 1239 JA FL 58201 16 STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 1/2 AVE. A NOTE: NORTH PORT,FL 34288 1/8"ALUM.(6063-T5 MIN.)OR #12 GRADE 5 SELF-TAPPING/ FULL THREAD 1/2 HINGE SPACINGS ARE: PH.941-380-1574 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 8-1/2" FROM ENDS SHEET DESCRIPTION: HINGE ANCHORS INTO CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1-3/4" 2-1/2' 21-5116"MAX.O.C.FOR UP TO 81"UNIT HEIGHT. INSTALLATION DETAILS 20" MAX.O.C.FOR OVER 81"UNIT HEIGHT. HINGE ANCHORS INTO HOLLOW OR GROUT-FILLED 3/16"ELCO ULTRACON 1-1/4" 2-1/2" DOOR CMU(ASTM C-90) DRAWN BY: DATE: HINGE ANCHORS INTO 2X MIN.SOUTHERN #10 WOOD SCREW 1-3l8" 7/8" PINE(G=0.55) ADE 09/08/11 HINGE ANCHORS INTO 16 GAUGE(0.060")MIN. #10-16 HILTI KW IK-FLEXOR ITW FULL THREAD DWG#: REV.: STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 112 HINGE LAYOUT CWS-641 B HINGE ANCHORS 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD 1/2„ 1:30 SCALE: SHEET 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 1:2 11 OF 12 TYPICAL HEAD ANCHORAGE INTERIOR 1/4"MAX.SHIM aabm-ffl MIN.EMBEDMENT WINDOW SYSTEMS MIN.EDGE DIST. SEE TABLE 1,SHT 11 1900 SW 44TH AVE. SEE TABLE 1,SHT 11 CONTINOUS DBL 1/4'BEADS OF SEALANT OCALA,FLORIDA 34474 AROUND PERIMETER AT ALL INDICATED WWW.CWS.CC SUBSTRATE BY OTHERS POINTS BETWEEN FRAME AND SUBSTRATE SEE TABLE 1,SHT 11 MIN.EMBEDMENT BY INSTALLER. MIN.EDGE DIST. SEE TABLE 1,SHT 11 SEE TABLE 1,SHT 11 8700/10/50 PVC I m��A, i INSTALLATION ANCHOR SWING DOOR PERIMETER SEALANT 14'MAX.SHIM SEE TABLE 1,SHT 11 BYINSTALLER INSIDE AND OUT - � r o CONTINOLIS DBL 1/4"BEADS OF SEALANT Y w AROUND PERIMETER AT ALL INDICATED INSTALLATION ANCHOR w ¢ m POINTS BETWEEN FRAME-AND SUBSTRATE - - _ SEE TABLE 1,SHT 11 BY INSTALLER. U U Z m m 0 a o fA uj PERIMETER SEALANT BY INSTALLER INSIDE AND OUT Q ¢ O PERIMETER SEALANT °w w 2 BY INSTALLER SUBSTRATE BY OTHERS INSIDE AND OUT SEE TABLE 1,SHT 11 D HORIZONTAL SECTION o o ai MIN.EMBEDMENT 12 TYPICAL JAMB/HINGE ANCHORAGE p SEE TABLE 1,SHT 11 SUBSTRATE BY OTHERS m ¢ Z SEE TABLE 1,SHT 11 tiluRElrr,��� MIN.EDGE DIST. `���;VPG; SEE TABLE 1,SHT 11 v t No 58201 C VERTICAL SECTION k' 12 TYPICAL SILL ANCHORAGE ,p 9• STATE OF .41' 41.1 4(/ +ONA� z;z- 4/18/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: INSTALLATION DETAILS SIDELITE DRAWN BY: DATE: ADE 09/08/11 DWG#: REV.: CWS-641 B SCALE: SHEET 1:2 12 OF 12