Owens Corning Evaluation Report 037940:02:12=R7'
gne;Owens'Corning.ParkwaV FL10674-1112
Toledo,OH.43659 Date of Issuance:02/06/2012
Revislon':7: 04/18/2016.
SCOPE:
This;Evaluation;Report is,issued.under Rule-.61G10-1 and the applicable rules and regu.lation,governing.the use of
construction.materials-in the State of Florida The:documentation submitted has been-reviewed-by Robert Nieminen,
U. for use, of th'e::product "under,the:,Florida Building Code and Florida Build_ Ing Lode, Residential Volume T.he
products described herein have been,.evaluated for compliance.with the 5th. Edition (2014) Florida Building.Code..
sections noted herein,
DESCRIPTION:'OwensCorning:Asphaft,Roof Shingles
LABELING: Labeling.::`shall be.in accordance with the requirements-the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE:- This. Evaluation Report is valid, Until such time. As the: named pro.duct(s) changes, the
'referenced Quality Assurance:documentation.changes,;or provisions°of the. Code that relate to the.product change.
Acceptance'ofthis Evaluation Report. the named client constitutes agreert ent to notify Robert Nieminen, P.E. if
product changes or the [eferenced Quality Assurance_ documentation changes. TrinitylERD requires a, complete
.review of this'Evaluation Reportrelative to;updated.Code requirements with-each Code Cycle.
ADVERTISEMENT: The Evaluation.Reportnumber pteced`ed:b'the words-'TrinitylERD:.Evaluated" may be displayed in
advertising literature. If any;portion ofthe Evaluation Report is displayed;theii.itshall.b6done in its entirety:.
INSPECTION:.Upon,request,a COpygf_this entire Evaluation:Report shall be:provided to the user by-the,manufacturer or
its-distributors and:shall be available for'inspection at the job site at request,of the Building Official.
This Eva Iuation.Report consists of'pages 1 through 8.
Prepared.by \\�t�nt)rhiry,
y -
4 y .L
Robertl.M.N eminen,.P.E: ThetaalmileseaLappearingwasauthorizedby8obertMeminen..
�:h pro V 4). t•;�`'. P.E.on 04/18pp16.`This does nai serve as an etectr8alnlly signed
Florida.Registration No.59166,Florida&AANE19837 document.Signed,seatedhardeopieshave been transmitted tothe,
CERTIFICATION OProduct Appt4ol Administratoi eqd to the named'client
E;INUEPENDENCE.
1., TrinityI MD does not have;:nor-does•.it-intend to.acquire or will it acquire;-a financial interest im any company manufacturing or
distrtbuting;products 1.tevaluates.
I Trinity.i Ek6ls not owned,.operated'or controlled by any company manufacturing:6e distributing products it.evaluates.
3: RobertNieminen,.P.E.does.not have nor will acquire,.a financial interest in any.corn manufacturing or distributing products.for.
which the evaluation report$.are;being issued.
4. Robert Nieminen,:P..E:does`not have;nor will`acquire;a financial'interest in any other entity involved in the:approval proce;s of the
product.
5: -This Is a-bt ildi ig code evaluation. Neither TrinitylERD nor`Robert Nieminen,,P.E,are,in.anyway;the Designer,of Record for any
project on which this Evaluation.Report,or.previous versions thereof,,is%was used for'permltting or.design guidance unless retained
specificallyfor thatpurpose.
TRINITY1 ERD
5.4 Wind"Classihcation:
5.4.1 All Owens Corning- shingles;rioted herein are Classified'in, accordance with FBC Tables 1507.2 71. and
R905:2 6:1 to ASTM D3161,Class F and/or ASTM D7158, Class H,'indicating the shingies:'are acceptable for'
use ih-all.wind zones up to V,d=150 mph;(vast=194 mph), Refer,to Section.6.for installatlon-.requiretn nts
to meet this wind'_"rating:
5:4,2 AII:C+:wens Corning hip&ridge-shingles,;Starter-Strip Shingle and Starter Strip Plusnoted herein are Classified.
in accordance with FBC Tables 1507:2:7.1 and 8905:2.6:1 to ASTM D31611 Class F,'indicat ng"the shingle are
acceptable for use in all wind zonesup to Weld_150 mph{volt=;194 mp}). 'Refer Eo Section A for installation
requirements to meet this wind ratirig.
5:4.3 Classification:by ASTM D7158 applies to exposure category.6 or Cand,a`'building.height 6f-66 feet or.less:.
Calculations by^a qualified design professional.are required for conditions outside„these limitations: Contact
the:shingle:manufacturer for:data`specif c to'each'shingle.
5.4:4 -Refer io Owens Corning published information,on wind resistarice and.installation limitations,.
5.5 All products in th6:roof,assembly shalt have quality assurance:audit-.in accordance.with the Florida Builth[g
Code=and F;A.C,Rule 61G20=3,
6. :IN S7I1U;41i=
6_1. Underiaymerits
6.1.11 Underlayment ahall be acceptable to Owens Corning-and shall-hold current Florida; Statewide Product
Approval,or'be Ct,ca{Iy Approved"per R--16:61c2o=3;per FgC Sections 1507:2.3;1501.2:4-or 8905.2.3:
6.2 Asahalt.Shinetesv
6.2.1: lnstaiiation.,of asplait.shingtes shall comply:with the manufacturers current,published:instructions,,using
minimum"four(4} nails per-shingle in accordance with FBC.Sections 1507".2 or 11905.2;"with the'following"
exceptions:
Berksriire;shingles require minimun five'(5),nails�pershingle.-
WeatherGuard HP°Shingles require minimum:six(6)nails pershingle.
Devonshire*.,shingles require minimum six(6)nalls"per shingle.
> StarterSidp ShIngle and Starter Strip.Plus require minimuMfiv.,e'(5)nails per:strip.
Refer"to Owens Corning':pubBhed information-on wind resistance and installation limitations;.
6.2':2 Fasteners shall be in.accordance with.the manufacturers"published requirements, b"ut not less than FBC
1507:2.6 or 8905:2:5. Staples.,are not permitted:_
6.2.4 Where the roof slope exceeds 21, units vertical 'in 12 :units':horizontal, special methods:of fastening are
required.=See"figures'tieiow fog details.
6.2:5 Minimum Railing.—Starter.Strip:Shingle and'StarterSirip Plus:
FehumierlsymeM Qedc fltandeymem
Dkk S e
SelWdheted,:
Weathed.oek°
'undefayment �9e
DO
edge
,^S' r' Hais locittd
Nads iacated' r-1'irgmeaae
r-3*hamvave
160hilWA Sei[•sealingadhesive Iestalt3st5taesirStdyPlua ed ata
Starterq�'p posAiairedatongeave w9h6 removed
shingle with
8"removed staKat strip ihingle ove Bangs eaves and rakes-'h=T siatd5 Piu'ay.thuip�roves and nkaa U4'-u4;
Exterior Research and Design,LLC. Evaluation Report 037940.02:12•R7
CertlnearicfAuthorhairon,k95i13 FL30674R12'
Revislon 7:04f 28/2016;
Page 3 of 9
i • .:
Fl r3lid Dei trent SCIS Home ! Levi, � user Reglstmuen '�'mot Topics I SWblt.S4kt*de � statsW Fddis:' puhltrations � FBGSlaff � Bcls'Sfte Map i Lin 5.earsti
BuSIn: �5
PraT[ess � � Product Approval.
1 UsEB Fi#?iic_.User
f�Egl1� ion'
act ncoroval Menu r.PrcEuct or naoFlcatlan_Seaccti">Aoo4eca94 t:Ist APPlteatloe'Detel!
�,# F1:10b74-Ri2'
Application Type Revision
Codie,Uerslon 20i4,
Application'Status Approved
*Approved'by bbPR.,Approvpls by DBPRshali_be reviewed and'ratlFied
by the:POG;andjor_:the Commission if necessary.
Gomrrients
Arct lved C-3
Product_Manufacturer Owens-Corning;
Address%Phone%Emaii Ane Owens.Corning Parkway.
Toledo;:01443659
'(740)404=7829
`g reg:Keeier�owenscarni ng Ecom
:Authorized Signature Greg tCeeter
greg.keelj r@owenscorning:com
Technicat Representative, Mel-Sancrant
Addiessj/Phone/Email, 1.Owens Corning-PKWY
Toledo,,OH:43659
,(.919)376-13360`
met.sancrant@owenscor..nig;com
'Quality Assurance Repfesentative
Address/Phone/Email
Categorq Roofing
Subcategoi y Asphalt Shingles
C irripliance Method' Evaluation Report`from a Florttla RegisEered Acchttect oha Licensed
Florida ProfesIlonai'Engineer
0 Evai'tiation PAiJdtt-Hardcopy Reeelved,
Florida'Engineer of Architect Name who developed kobert J.M.Nlemmen
the Eval uatlom Report
Florida`.Licens(i PE-59166"
Quality Assurance Entity UL Lff
Quality Assurance Contract Expiration Date 08/2Qj2f)}Z
Validated By John W.,Knezevicfi PE
lel Validation Checklist Haf&60yReceived.
certificate.of Independence FLIo674 R32 SOI-`2026 01 COI'Nieminen ndf
ikeferenced Standard and Year(o`f Standard), �taIldatd YAM
ASTM D316f 2049.
ASTM D3462 2009
ASTM D758 2008
Equivalence.of'Product Standards
Certified,B,y
Set:tions from the.Code
Product Approval Method Method 10 ption.D.
Date;Submitted 04/18/2016.
Date Validated' 04/19/2016'
Date'Pending'FBC.Approval 04/20/2016.
Date-Approved 06/08/2016-
-Summa of-Products
Fl# Model,.Number or--Name' Descriptl6h,
19674.1. Owens.Corning Asphalt:Roofing 3;tab '+Aab, 54ab,laminafed,starter'and hip=&;ridge
Shingles and.Starters sfiingles
Limits:of Use Installation Insteudldiis,
Approved foruse`in HVHZ:No FL 0674 Rf >II 0 6.04 FINAL R Oe AsPHA
Approved for use'outside HVHZ:°Yes SHINGLES FL10674-1112 ndf,
ImpaetResistant:A/A Verified By:,Robert.l. M Nieminen PE-59166
Design Pressure:N/A Ce',
Indepentlent Th rd,'Party Yes,'
Other:Refer to ER,=Section S. Evaluation Reports,
FL10 i"dii AE`2M 04 FINAL ER OC ASPHALT
SHINaes FL10674-R12:odf,
G�eated tiy:Independent Third Party:Yes'.
Back.. Wext.
Contact..Us 1940.North Monroe,Street.Tallahassee FL 32399:Phone:SSN487=1824
7hiiState 6fTlofida4s an AA/EEo employer.Coovnoht 2007-2013 State of Florida. Privaw Statement^Accesslbilitrstatement Refund Statemeht'
Under Florida,law,email addresses,are public records.pif:you do not your e-mail address;released in response: a'publicrrecords,„request,do not send electronic
mail to thls endty iiute0d,,mniact the offtce b,phone or by tradlifonal mad.If you have any questions,:please contact 650.487;1395 'Pursuapt.to Section
455.275(1),Florida-.Statutes,effective October 1,2012;-licensees.1loensed under Chapter 455.F.S.must provide the:DepartmenCwith'an,emall addnass if ttioy
mhive-
oner The ealls provided may be used focofnclakommunicau6n with the.licensee.However email addresses arepublic record.If,you[do not with to supplya
,
personal address,,please provide;the Department,wlth'an email iddress which can be matle avallalila to.the public To determine if y06F re a licensee under chapter
4551 Cs.;please dick'he er . ... - .
Product_Approval Accepts:
sccurit mrntcs.
`TR'1N1TYjERD
R00FING SYSTEMS EVALUATION:
1. SCOPE:-
Product-Category: Roofing'
sub-Category: Aspkialt Shingles.
C6mp1iance$tateirienf. Owens Corning Asphalt;Roof"Shingles,.as"produced by.Owens Corning;have demonstrated
, ..
compliance with=the following sections of the Florida Building Cade and:Florida Building Code, Residential Valur"r►e
through testing in accordance with the following Standards.: Compliance is,subject;to the jnstallation Requirements:
and Urnitations,/Conditions.of Usenet forth herein;;
2. STANDARM.
Section'. Property Standard Year
1507:2 5,.:8905:2:4 Physical Properties. .ASTM_D3462:, 2009
1507.1,7:1,11905 2:6:1 Wind Resistance ASTM-D-3,161 2009
150'7.2,7.2,11905:2:6:1 Wind Resistance AkgM.D7158: 2008.
3: REFERENCE ,
Entity:: Examination. Reference: Date
UL LLC(CER9626) Physicals,&Wind Resistance File R2453,:Vol.3' Q/11,511007UL CCC(CER9626) Physicals&{Hind Res+stance 20120516� R2453 05/16/2012
UL LLC(TST9628) Physicai.Properties 06CA202163: 04J18/2gg6:
UL LLC-(T'S Wind Resistance 11CA34308 02/18/2012
uL LLC(TST9628) Physicals&wind.Resistance 4786093137 02/01%2014:.
uLCLC(TST9628)' Wind'Reslstance 4786126532` 02J10j20]4.
.UL LLC{TST9628} Physical Properties Classification letter. 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2P15-
Via Dade-(CER1592) FBC.HVHZ Compliance:. Various NOAs Various
ULLLC ,(OJUA9625)' Quality'ControL Service Confirmation,82453 Exp.08'/20/2017
4. PRooucr MscIZIMom.
4.1 Asphalt-Shingles,:,
-4.1.3 Classic and Supreme:are'fiberglass reinforced,3-tab:as0halt:roof shingles:
4.1.2. Berkshire are fiberglass reinforced,4-t&a'sphalt roof shingles:.
4.1;3. Devonshire are-fiberglass:reinforced,5-tab asphaltroofs
4.1:4 Duration Tr6befinition 'D)uratim*, Dur=ation Premium Cool, TfoDefinition� Duration Designer Color
Goilectiori,Trul7efini406 'Oakridge, Oakridge* and W. eather'Guardo V'are fiberglass reinforced;laminated
asphalt roof shingles:
4,2 :Berkshire Hip&:Ridge Shingles,High Ridge,lllteatherfuard4 HP Flip&-Ridge;;Shingles PeoEdge Hip&Ridge
Shingles and b.uraRidge""Hip.&Ridge_Shinglet are°fiberglass reinforced,hip:and ridge asphalt_roof shingles:
4.3. Starter Strip:Shu gie,Starter.Strip,Pltis and Start6r5S ingle,Roll are:starterstrips.for asphalt roof shir€gies;
5. UMITATIONS:
5:1 'this is a"building,code evaluation. Neither.TrinitylFRO' nor" Robert.Nieminen, P:E. are,'in.any,way;.the,
D)esigner-of Record for any project on which this EValuatio.n-Report,orprevious versions-thereof,.is/was:used:
for peernitting-or design-guidance unlesscretained specifically,for that purpose.
5.2 This Evaluation,Report is not far use in theEDVHZ.
5.3 Fire.Classification,isnot part of this Evaluation°R'epoct;refer to current Aipproved Roofing Materials Direetvey
for fire ratings- this product..
Exterior Research and Design,LLC. Evaluation Report,037940.02.12 RIs
Cer6flcate ofAutho lrailan#8503 FL10674-R12:
Reuision7:04%18/2016.
Page 2 o€8
. TRINITY,6C)O
1.6 Minirnum`Nailing.--Classic®=&Supretre:
Namur moillsrd.or' ea
Anaparn Nornul_ mikas"'or' At"
Ad.
rs
Wind Areas H Wind Ars High Wind
i0►ee psrs.:vlsntott eiorrmw An�.tiYtvisrrt�fwrtar
Y'
Ams pan vJontos noi!males: Aran Will, fwrhs
.. . r r.:: BC r
•.
I
6'EaFposun 86Jt3'Ex _:: _ ._
Fxpoge/dn pew».
E�oeteldn:
6,2:7' Minimum,Nailing;=Mfthirell:
't>�al3iR.stiip. $dalant strip
T97-
to tin de sc+d+dw �is taade it8�aa
r
Standard Fastening,Pattern 6-Railfastening Pattern.
' ta'tba do'smttxbr
-44 01W 0-
vBYt
r. t.
Aspfiatt roolhto-., ,
Qakmirto do teehoda eetaka:
Mansard or;Stgep Slope::Fastening Pattern
Exterior.Research and Design,LCc. Evaluation Reporf 037940.02 127RT
:CuWcate oJAythorhatlon 119503:
FU0674-R12,
Revision 7:04/18/2016.
page:4:of8:
TRINITY ERD
6:2:1 iGlinmuttYNailing='TruDefinition�0akridge� OaTiridge
4 Nasi Fatten► 6`Nall Pattsin`
Esgi ma con 4 pws4`77—
Esquana can 6 clauns
i
-771
6616'Expasure_ 6;68"Exposura. Naos
EkpoglNaida65/8pidg. Plans. fi6/8"ExP�!� Ct3vas 66/e"Eicposute
CL?vos E+p»sla43nd�'66/Pprd
fxpos{;�drsdc68J8pitl¢. ErpostiF6zrck5Sl8prdg.
,Standard Fastening Pattern. 6-PJait Fastening pattern
F�atenin"rorsio
0 P�GreatarShan;21:t2;
S�M�OSteu.Mnp c*r�ein. ,
T
..fcur l"..EpoH otAfPneA RmWig G'miM _ .
Mansard or$teep,SiopeFastening.Pattern
6.2:1 Minimum Nailing--1NeatherGuardlb H-P:
- •i:,�,:. .: y:' A'J.! F��3'lisa�Mil{�;
Exferior Research and Design,LLC; Evaluation Report037940.02.12�R7
Cen$cate ofAuthorizatlon#9503 FL10674•R1Z
Revklon 7:04J18f 2016:
Page 6 df 8
TRIf11Y ERQ
U.& Minimum Nailing—.Devonshire"":
a „ n n •7n
+7
Orm _.
��..r Nalls
54/81 ex osuw Se�7nt iGCatiOlf_.. - - ,:
bWiidbe'ds 5-5/8'puig Ubiaad6n del s�ledor su"
Sk=
V.
Tee 1 'tits o(lts hak goof Cement
kandard'6-Nail Fastening,Pattern Minsard or•Steep-Slope Fastening.Pattern
6:2.9 Minimum Nailing.—Durations,TriaDefnit on® Duration,_pdrk bri :Premium`Cool &TruDefnition Duration
Designer Color Collection,:
=ttsi!Fastening.Paitirii &Nell Faatrning Pa149m.
suntwm raewng�a wtpd� surettarotssnMiw ueaivam
Nui;lypwt �:'ti�+:
_sr .... it
_j
11.111•MER" 'd� � '� "� i l:tR'6•bls' _ _'�,,
Standard Fastening Pattern. 6=Nali Fastening Pattern
Fimtaolap for 8(opas GriiWr7W 21:12
1wsNo`tA tntMap un wldit.
N.a 1yv
1r
aim Ean .
f
Paw 1`1P?r�A,D!!�Raol4fC haMMnt
'Mansardbr Steep Slope fastening Pattern
Exterior Researchand-Design,LLC.- Evaluation Report 037940..01.111-97
CerW-teOkk6orizarI909503 FL106TA ii�2,
Revision 7.-.04/18/2016
Rage`5 of 8
:t
_TRINITYJJERo
6.3 Hip&Riidee Shingles-
6.3.1 installation of Berkshire, Hip and"Ridge:5hingles, High.Ridge, WeatherGuard HP_Hip and,Ridge Shingles and
Pr6Edge Hip&Ridge Shingles shall_compiy.with the manufacturer's;currentpubiished instructions,using four
(4) nails per shingle: installation:of`DurAidge'"Hip&Ridge,Shinglesshall'comply withAhe manufacturer's
current published; instrtictiarZs, ;using twa; (2) .nails per shingle.. .Refer to :Owens Corning published
information on,wind resistance and installation limitations, including=the use of-4 d'-sleaprig for wind.
warranties.,
6.3.2 Fasteners shall be.in accordance:with the martafacturei's published requirements; but not less°than TOC
1507:2 6 oc'R9052:5 Staples,are not permitted:.
6.3:3 MinimumAailing—Berkshire"Hip&Ridge and High-Ridgg",
Fip.1 FID.2,
t-- t "04 " .p:' 71!Vtna SideVis=+r:
Halts'
'lIDR9- ----,•
[.aninatall
1 t
t.
A l ( l
, l
6.3.4 ,Minirrum Nailing.-WeatlierGuard®=HP Hip,and Ridge:
. � Fig G�liip&'Ridge Shingle Fastening.
49
Fig:A Ftc�iltnDlMh0 TdDYluw
'E-aiuctbn b
P
ttatrs t#Ptb
ryi
--°°�
F3FOLUR
-
1z�'
Exterior Researchand design,CLC. Evaluation Report 037940.0212•R7
Certificate of,AiltharkWon X9503 FL30674-R12;
Revision 7:04/38/2016'
Page Z;of.8,
TRINITY I ERS
6.3;5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
PrevailingStatidard —1i°—•
FastoMOW
Wind.-DireWon
Scs&nt strip
. Peftern
$•
r�
12` `
Fasten 71h' 7'h' 8•Eitpos 1
ComE>
: . Fastanenr wft
R" Urnent
'6.3.6 'Minimum Nailing—:DuraRidgelm Hip&.Ridge Shingles,
'Note::The drawings below pertain,toiminimum,�as-tested attachrrlent requirements; Refer to Owens Corning
published,ipstaliation it structlans fortheir minimi m requirements.
Pranling rdDirgadanWe
tlt too,dQftilaliti dtinitt, ��% Vkq em p1 Ot' (•
pa+mrxi dal virile pros-ininta
�'
21 • Qarecr Cwutnq`umPla6 w G"
i U
i
7. LABELING:
7.1 Labeling shall,be in.accordance With the:requirements the Accredited Quality Assurance Agency noted
hereln.
7.2 Asphalt shingle wrappers shallndicate compliance with.one'of'the requiredclassifications detailed in FBC
Table 1507:2:7.1/R905.2:6.I.
8 BUILDIN6'PERm REQUIREMENTS:
As:%required bythe-Building Official or Authority:Having lurisdietian,in order to,properly evaluate the installation=:of
thlsproduct
9`.. MANUFAGTUEttNG PLANTS:
comae -the-:named CtA entity for inforrri`atian on which plants produce products.covered by Florida:Rule 9N-3 OA
re Uire.ments:.
10" QUALItY ASSURANCE ENtITY:.
UL LLC—QUA9625;{414)'248-6409;ka"ren:buchi!riann'.ul.corn
END OF EVALUATION REPORT-