Loading...
HomeMy WebLinkAboutDrawing FLORIDA BUILDING CODE 2014-5th Ed.-ASCEISEI 7-10-WIND LOAD TABLES-170, 176 mph Enclosed Building with mean roof height less than or equal than 60 Feet EXPOSURE C AND D -LOAD FACTOR:0.6 INCLUDED MIND PRESSURES IN PSF WIND PRESSURES IN PSF 170 MPH VELOCITY-EXPOSURE C 17 0 MPH VELOCITY-EXPOSURE D Building Roof Slope less than Roof Slope greater Building Roof Slope less than Roof Slope greater Height 10 degrees than 10 degrees Height 10 degrees ' than 10 degrees Positivel Negative Positive Negative Positive Negative Positive Negative z4 dr z5 z4 z5 z4,&z5 z4 z5 z4,&z5 z4 z5 z4,&z5 z4 z5 0-15 34.6 37.5 46.1 37.8 41.0 50.6 0-15 1 42.0 45.5 56.0 45.9 49.8 61.4 16-20 36.8 39.8 49.0 40.2 43.6 53.8 16-20 44.2 47.8 58.9 48.2 52.3 64.6 21-30 40.0 43.4 53.4 43.7 47.4 58.6 21-30 47A '51.3 63.1 51.7 56.1 69.3 31-40 42.5 46.1 56.7 46.5 50.4 62.2 31-40 49.8 54.0 66.4 54.4 59.0 72.8 41-50 44.6 48.3 59.4 48.7 52.8 1 65.2 41-50 51.8 56.1 69.0 56.6 61.3 75.7 51-60 46.3 50.2 61.8 50.6 54.9 1 67.8 51-60 53.4 57.8 171.2 58.4 63.3 1 78.2 LOC4'i1CN BROWARD COUNTY, PALM BEACH AND 07HER IDCATIDN BROWARD COUNTY, PALM BEACH AND 07HER EXANPIE COUNTIES EXPNRE Comm WIND PRESSURES IN PSF WIND PRESSURES IN PSF 175 MPH VELOCITY-EXPOSURE C 175 MPH VEIDCITY-EXPOSURE D Building Roof Slope less than Roof Slope greater Building Roof Slope less than Roof Slope greater Height 10 degrees than 10 degrees Height 10 degrees than 10 degrees Positive Negative Positive Negative Positive Negative Positive Negative z4 dr z5 z4 z5 z4 A z5 z4 z5 z4 A z5 z4 1z5 z4&z5 z4 z5 0-15 36.7 39.7 48.9 40.1 43.4 53.6 0-15 1 44.5 48.2 59.3 48.6 52.8 65.1 16-20 39.0 42.2 51.9 42.6 46.2 57.0 16-20 46.8 50.7 62.4 51.1 55A 68.5 21-30 42.4 46 0 56.6 46.3 50.2 62.1 21-30 50.2 54:4 66.9 54.8 59.4 73.4 31-40 45.1 48.8 60.1 49.2 53A 65.9 31-40 52.8 57.2 70.4 57.6 62.5 77.1 41-50 47.2_L51.2 63.0 51.6 56.0 69.1 41-50 54.9 59.4 73.1 60.0 65.0 80.2 j 51-60 49.1 53.2 1 65.4 53.6 58.2 71.8 51-60 56.6 61.3 75.5 1 61.9 67.1 82.9 i �FE MIAMI-DADE COUNTY t7CAE MIAMI-DARE COUNTYELEFL I GENERAL NOTES: 1-THESE TABLES ARE APPLICABLE ONLY TO CALCULATE THE WINDLOAD FOR COMPONENTS AND CLADDING (HURRICANE SHUTTERS.WINDOWS AND DOORSI APPLICABLE TO A SPECIFIC PROJECT.THE CONTRACTOR MUST PROPERLY SELECT THE DESIGN PRESSURE ACCORDINGLY WITH THE EXISTING CONDITION AND THIS INFORMATION BE VERIFIED BY THE CITY AUTHORITIES. 2-PLEASE,NOTE THAT A SPECIFIC PROJECT CONDITION IS NOT ANALYZED OR CERTIFIED BY THIS ENGINEER. THE SIGNATURE AND SEAL INDICATED ON THIS DRAWING IS ONLY APPLICABLE TO THE GENERIC WINDLOAD CHART BASED ON ASCE 7-10 PUBLICATION. 3-DO NOT USE THIS SHEET IF THE SITE CONDITION IS NOT COVERED BY THE TABLES OR A SITE SPECIFIC EVALUATION IS REQUIRED BY THE CITY OFFICIALS. 4-EXPOSURE 8(Section 26.7.3)-Urban,suburban and wooded areas and other terrain with numerous closely spaced obstruction having the size of single family dwellings.For building r_30ft exposure B prevails in the upwind direction for a distance greater than 1500 R 1 For building>30ft exposure B prevails in the upwind direction for a distance greater than 2600 ft or 20 times the building height,wichever is greater.Based on the FBG HVH7,use Exposure C when building is located in Exposure B 5-EXPOSURE C(Section 26.7.3)-Open terrain with scattered obstructions with heights less than 30',open country and grasslands.Exposure C will apply when exposure D and B do not apply. 6-EXPOSURE D(Section 26.7.3)-Flat,unobstructed areas and water surfaces prevails in the upwind direction for a distance greater than 5001) It or 20 times the building height,whichever is greater 7-BUILDING CONSIDERED ENCLOSED-All glazing shall be impact resistant glazing or protected with an impact resistant covering. 8-ULTIMATE WIND SPEED-V=170 MPH,175 MPH TOPOGRAPHIC 10-D R CT ON ALITY FACTOR Kd= 85( Wind Directionality Factor/ •••••••••r•® r ••••'•. 11-TRIBUTARY AREA:10 SOF •e• ! +/ 41 12-EDGE STRIP(a):The smaller of 10%of the least horizontal dimension w 40%of the ••• �� "' .. Mean roof height,but not less than the larger of 4%of the least horizontal dimension or 3 ft. m°, M ;• 4�; ��F •:`' o * a Roof Slope E N 6 C Ojnc. _ STA"rE O'1 T . Engineering services-CA 6116 0-� ,'••^ '•, f �•, Al ( 0 g •a 1791 Blount Road-unit 907 •:�r� K •••• Z4 Pompano Beach-Florida 33069 •'•. �f✓(��A re •••• I24 IZs 5I t"> Tel:(754)307-1319 Fax:(754)205-6846 ••••••r•���x••• • I MEAN ROOF E-mail:Engco@AOL.com HEIGHT 9=cr9'r :y B�, eJor I I I a<=BWx0.1ora-hx0.4 BW less or equal than BL DATE: 07/21/2017 a must not be less than PEDRO DE FIGUEIREDO-PE 52609 a=3 feet or a=0.04 x BW NOT VALID W(OUT SEAL 7/21/2 017 4y Opening- --- ----- 1. Su move Accordion Shutters O rndow) t- 2. Supemova Accordion Shutters w (4V1ndow) G�9 3. Su mova Accordion Shutters eG dow) d, 4. Supemwa Accordion Shutters LU a e� z ( ndOW S. Supernova Accordion Shutters (Window) Y 6. Supornova Accordion Shutters rndow) 1 7. Supernova Accordion Shutters ow) 8. Supernova Accordion Shutters d Wnuow) - . . . 12. Supernova Accordion Shutters (Madow) 13. Supe ova Accordion Shutters 13. ; o 14. Supernova Accordion'Shutters o a ( ow) 15. Supemova Accordion Shutters., ` ,g,; ( ndoW) 3 N N N ti 16. Supernova Accordion Shutters � (Window) 13 ? 3 4 5 14 15 6 Cl Qm t� >_ co R 09. 16 - �" c c 1 -U-- CO .CO-- a� NOTIO SauE Oct 26,2017 Site Plan 1