Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online https:!/u«v.tlolidabttildiu�;.orglpl/pr_app_lst.asp t ,t F _'fe'" 4xFr k k Th�Cktlab '."C'R-v a si� AM BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search )s: l uct Approval au r • USER:Public User Prod i • Product Approval Menu>Product or Aonthcation Search>Application List Search Criteria Refine Search Code Version 2014 FL# 23089.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL 1 Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL ;I Impact Resistant ALL Design Pressure ALL Other ALL i Search Results-Applications,._._______.__-_,___—.._._...____.____ FL# TVDe Manufacturer j Validated By Status !j 1 FL23089'New 'Sun-Tek Mfg Miami-Dade BCCO-VAL'I Validated' FL#:FL23089.1 f(786)315-2590 t ;I Model:CMA-D ' r Description:CMA-D Aluminum Skylight li i Category:Sky Lights iSubcategory:Skylight i `Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.,. ' I Contact tis::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487113824 i The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Fiorlda.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,-please contact 850.487.1395.'Pursuant to j Section 455.275(l),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provlde the Department with an email address if II they have one.The ematis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Cara Safe I of L., 10/19/2017 03:27 PM �I _l G0rualEI!ARCli7EQURE A MNMI FLORIDA]713] AB 1 _. _�_.._, _. —...._. .:_—._.... T.306.660.A3fe 2 F:866 403.1686 _ E:create®gonzaleldreNiteclurecom ENGINEERSOF RECORD —.—_ ._-•. A �eaow�Ao wz.a� L A 2 SECTION A-A SECTION A-A weoo<cP�eRsmu SEAL/SIGNATURE OB SYSTEM NO.C-AJ-7003-OUTSIDEAIR PENETRATION 07 SYSTEM NO.C-AJ-2377/PLUMBING a oeN a DRAWING ISSUE 06-28-2017 PERMIT ISSUE V�(a'�m AA 2 _ �— ____— A IS _' _-••_..._-.... - - _- ____ _ -_ 2 0 A SECTION A-A SECTION A-A SECTION A-A n N.T.S.-ELECTRICAL—AL CalOUIT N.i.i-vLUu6+N0/EU:Ci.NON NTL URGE PIPE Q � W Q U O6 SYSTEM NO.C-AJ-1427('JULY 09-2003 O6 SYSTEM NO.W-L 1296!ELECTRICAL METALLIC CONDUIT 04 SYSTEM NO.W-L 2147 •AUG.13 20D1 =J o 25 N A A L, t 2 DESCRIPTION SECTION A-A SECTION A-A SECTION A-A THROUGH PENETRATION FIRE STOP .._.............._.........._._..__ DETAILS N.T.S.-PLuuBIr+C k EIECT,rv0u uTL PIPES/ SCALE:AS NOTED ca+DuiTz SHEET A6.1 03 SYSTEM NO.C-AJ-2378 -JUNE 2002 02 SYSTEM NO.W-L 2299 -JUNE 2002 01 SYSTEM NO.W-L 2300!PLUMBINGI ELECT.NOM.METALLIC SMALL PIPES Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=-v... i 4 s If c I { i ; r7` WIR C 6 i:. i --�" 21 I'm BCIS.Home Log.in { User Registration Hot Topics Submit Surcharge i Stats&Facts Publications i FBC Staff SCIS Site Map Links ; Search ( „Product Approval S7 i USER:Public User d b r Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL23089 Application Type New i Code Version 2014 Application Status Validated Comments Archived i Product Manufacturer Sun-Tek Mfg Address/Phone/Email 10303 General Dr Orlando, FL 32824 I (407)859-2117 jfeudner@sun-tek.com Authorized Signature James Feudner engineering@sun-tek.com 1 I ' Technical Representative James Feudner Address/Phone/Email 10303 General Dr Orlando, FL 32824 engineering@sun-tek.com Quality Assurance Representative James Feudner I Address/Phone/Email 10303 General or Orlando,FL 32824 (407)859-2117 Ext Ill engineering@sun-tek.com I i Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing I i Certification Agency Miami-Dade BCCO-CER Validated By Miami-Dade BCCO-VAL i i Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 lEquivalence of Product Standards Certified By i i Product Approval Method Method 1 Option A i Date Submitted 10/09/2017 I I 1 of 2 10/19/2017 03:27 PM I �I Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=w... z Date Validated 10/16/2017 Summary of Products FL# I Model,Number or Name (Description 23089.1 CMA-D CMA-D Aluminum Skylight' Limits of UseCertification Agency Certificate Approved for use in HVHZ:Yes FL 23089_RO_C_CAC_15051308 CMAD NOA.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/22/2021 Design Pressure: +60/-60 Installation Instructions Other: FL23089 RO II 15051308 CMAD NOA.pdf Verified By: Miami-Dade BCCO-CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 23089.2_— 'HSF — +Hurricane Self Flashing(HSF)Aluminum Skylight `Limits of Use Certification Agency Certificate j Approved for use in HVHZ:Yes FL23089 RO C CAC 15051307 HSF NOA.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes j 01/10/2021 Design Pressure: +60/-60 Installation Instructions Other: FL23089 RO II' 15051307 HSF NOA.pdf Verified By: Miami-Dade BCCO-CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: - --- -- ------- -— -- —--- — 23089.3 MD-CMA _ MD-CMA Skylight Limits of Use Certification Agency Certificate I Approved for use in HVHZ:Yes FL23089 RO C CAC 15051305 MDCMA NOA.pdf I Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/13/2018 Design Pressure: +60/-60 Installation Instructions Other: FL23089 RO II 15051305 MDCMA NOA.Ddf Verified By: Miami-Dade BCCO-CER I Created by Independent Third Party: 1 Evaluation Reports i —� Created by Independent Third Party: Back Next I Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 I The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are Dublic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To"determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe . I I I I I I 'I 2 of 2 j 10/19/2017 03:27 PM MIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidAde.gov/economy Sun-Tek Manufacturing,Inc. 10303 General Drive Orlando,FL 32824 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Model CMA-D Aluminum Skylight APPROVAL DOCUMENT: Drawing No. CMA-D-004,titled"CMA-D",sheets 1 and 2 of 2, dated 05/22/2000,prepared by the manufacturer,signed and sealed by James D.Wells,Jr.,P.E.,on 05/04/2015, bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. j RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance;of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of;the Building Official. This NOA revises& renews NOA#12-0517.24 and consists of this page 1 atid evidence pages E-1 &E-2, as well as approval document mentioned above. The submitted documentation was reviewed by H lmy A.Makar,P.E.,M.S. NOA No.15-0513.08 MIAMI-DADE COUNTY Expiration Date:02/22/2021 1 Approval Date;01/2112016 0 / Page l i Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 12-0517.24 A. DRAWINGS 1. Drawing No. CMA-D-004,titled"CMA-D",sheets 1 and 2 of 2,'dated 05/22/2000,prepared by the manufacturer,signed and sealed by James D.Wells,Jr.,P.E. B. TESTS "Submitted teutder NOA#11-0114.03" 1. Test reports on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 3)Water Resistance Test, per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201„94 5)Cyclic Wind Pressure Loading per FBC,TAS'203-94 6)Forced Entry Test,per FBC 2411 3.2.1,TAS 202-94 along with marked-up drawings and installation diagram of CMA-D Polycarbonate Aluminum Fixed Skylights,prepared by National Certified Testing Laboratories,Test Reports No.210- 3716-2, dated 11/22/2010,with a revision dated 03/07/2010,signed and sealed by Gerard J. Ferrara,P.E. C. CALCULATIONS "Submitted under NOA #11-0114.03" 1. Anchor calculations prepared by J&L Wells Consulting LLC, dated 01/04/2011,signed and sealed by James D. Wells,Jr.,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Depailment of Permitting, Environment,and Regulatory Affairs(PERA) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 12-0110.04 issued to Palram Americas,Ine.for their"Corrugated and Flat Polycarbonate Panels",approved on 02/23/2012 and expiring on 01/22/2016. 2. Notice of Acceptance No.08-0305.02 issued to SABIC Innovative Plastics for their"Lexan Sheet Products" approved on 04/24/2008 and expiring on 07/17/2013. 3. Notice of Acceptance No. 10-0329.03 issued to Sheffield Plastics,Inc., for their"Makrolon Polycarbonate Sheets"approved on 07/07/2010 and expiring on 08/27/2012. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC issued by J&L Wells Consulting LLC, dated 04/25/2012, signed and sealed by James D.Wells,Jr.,P.E; "Submitted under NOA#11-0114.03" 2. Statement letter of code conformance with FBC 2007 and no financial interest issued by J&L Wells Consulting LLC,dated 03/17/2011,signed and sealed by James D.Wells,Jr.,P.E. lto6y A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 15-0513.08 Expiration Date:02/22/2021 Approval Date: 01/21/2016 E-1 i it s I i 'I Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED I 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. CMA-D-004, titled "CMA-D", sheets 1 and 2;of 2, dated 0512212000, prepared by the manufacturer, signed and sealed by James�D. Wells, Jr., P.E., on 05/04/2015. I B. TESTS 1. None. C. CALCULATIONS "Submitted under NOA #11-0114.03" 1. None. D. QUALITY ASSURANCE 1. Miami-Dade County Department of Regulatory and economic Resources (RER). I _ �I i E. MATERIAL CERTIFICATIONS ! 1. None. j F. STATEMENTS ! 1. Statement letter of code conformance to 2014 FBC issued y J&L Wells Consulting LLC, dated 05/05/2015, signed and sealed by James D. Wells, Jr! P.E. I W& 'i it I i I I � i y A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.15-0513.08 Expiration Date:02/22/2021 Approval Date:01/21/2016 E-2 i ,I I ' % \ Sun-Tek Manufacturing,Inc. INSTALLATION INSTRUCTIONS POLYDOME SERIES w !,',SUni"Tek °0'/859FL-232824Ve MODEL CMA-D 0 407/859 2117 Use on an type roof(curb w �K�`"�;1'C'h► �www.Sun-Tek.com v yP required) 6d,6—r—zCustomerService@Sun-Tek.com au-X cr ' • Fagtener5chedule `• t - y� u 6. III �'• SKYLIGHT - TO CUBE 9 illi CUBBTO DECO TO" Finished n] ] DECK POLY Opening Fin on P�IHeasd 110.2%• •S' •1. size (Drywall eurbo a ide Center stew. Dens awe Riven If—CURBO.D.—!I Code Raol Op ning Dime I ) Dimension Spacing Stl"e s9de SWg 5�ae i°'d'ge Sidoet 2269 22K' 6,•, , x 9h 21" h.x 68(; 25 ,.x72Ya; 24 5 <34 7 3. 12 e_Fnuhed_, ,. .6' 3030 30Prr Opening 'x 30ya' 29'h'x 29h' 33K'x 33'h 16'01 32 3 3 3 3 6 6 Rsof 3646 3046A' -2955'.45X' 33wx 49w 160132' -a �3 5' 3 -9. 6" Openmg 'h'z —'i 3069 30'h'x6915' 29'h'x68K' 33Wx72W 16'Or32' 5 3 9 4 12 6 You will need: •hammer •sealant/mastic 3636 3.K'0616' 35Wx35'h' 39%' 39W 16'0r32 4 -4 4 ;71 .;x< •keyhole saw •tape measure •skill saw •chalkline or straight edge 4646#X4S' y 45Ya' 49w'x 498'16;24'48' 4 4 5 5 9 9 •nails •trowel or caulk gun •drill •utility knife 4669 13^x 68h 49h't 72Ya'16;24'48' S ;4 10 6 IS 9-.' .2 x 4's For Light Tunnel: RECOMMENDED SEALANTS: 4689 88'h' 49ya'z 92W 16;24;48' 5 4 13 6 15 9 .8 or 10 penny nails 100%Silicone CLEANING YOU R SKYLIGHT: Use a mild glass cleaner(such as Glass Plus)and a clean sponge or soh cloth.Fresh paint splashes,glazing compound,etc may be removed before •plywood or drywall Sealants approved for use on drying by rubbing lightly with a soh cloth or cotton ball soaked In isopropyl alcohol. polycarbonate(contact Sun-Tek MlAnlonDe •STS 1000(Sun-Tek exclusive)Butyl rubber DO NOT use abrasive or highly alkaline cleaners,ammonia,benzene,gasoline,acetone,or carbon tetrachloride.Do not clean skylight in bright sun or ® sealant/caulk high temperatures.Periodic waxing with a high quality,non-abrasive wax such as Mirror-Glaze will help maintain the good looks of your skylight. LIGHTTUNNEL INSTALLATION INSTRUCTIONS For homes with an attic,it is necessary to build a tunnel between skylights and ceiling.The tunnel walls may be straight,or Flared for extra light and FAILURE TO FOLLOW RECOMMENDED INSTALLATION PROCEDURES MAY VOID WARRANTY architectural appeal.It's very easy to increase the tunnel size along the length of the ceiling joists.As long as no roof-supporting members are cut,no special framing is needed.While it is possibleto Flare the tunnelin all directions,ifsupport members are cut,special framing will be required forstructural Please read instructions completely before beginning. Jar h hh support.In this case you must consult a qualified building professional to insure proper and safe results. Deck and roofing felt ShOUId Already be installed. 1 After roof and ceiling openings have been framed,measure distance(at each corner of roof opening)between rafter/truss and ceiling joist. Inspect skylight for damage before installing.Peel back 2 Using these four measurements,cut 2 x 4lumber for vertical support members(two per corner). protective plastic to inspect dome.If skylight is damaged,do 3 In each corner,nail vertical support members Into place at right angles to each other. not install.Please contact your supplier for information on a 4 Measure,cut,and nail tunnel walls into place.Suggestions for lining tunnel: replacement. -use drywall,tape corners,and paint white using regular or texture paint.(Texture paint alone will hide and fill untaped joints,but in time,cracks may appear in comers.) 2 To properly position skylight between trusses/rafters,locate the use prefinished paneling with molding in corners. roof opening from the underside of the decking.Drill holes or �h -line the tunnel with cedar,pine,or a wood to coordinate with your decor. drive nails to mark corners.(If this area is not accessible,locate -for special effects,try painting-the-tunnel a striking accent calor,or use mirrors or wallpaper on V -- - a - - -- --_ - _ the ceiling from inside the house,mark and cut opening in _ __ tunnel walls. ceiling,then mark roof opening.) 5 Caulk the slight gap between the tunnel walls and skylight base. ' Finish off tunnel at ceiling with molding,or blend edges into ceiling with texture paint. 3 Remove shingles 6-8"out from roof opening. 7 Be sure to wrap the exteriorofthe tunnel with insulation for energy savings. Before cutting roofopening,check.measurements against size POLYDOME SKYLIGHT LIMITED WARRANTY chart.Snap a chalkline from corner to corner,or draw line with a sa tekaaanufa[Wd I.c.rU,TeklI030]GenaalDdV,,.Ward,nwids3 24.14071eS42117, mr,thl,SkyRght—,(.Ub u,gtermsendro[tlRbm:0.WamnryCowrage:Th4waoenryappliestobothou-1ginal[ straightedge, P 9 hted e,theneutroofo enin .urrhaserendfim ansume,cwnerdaikylight made by SumTek.B.Wenanty DurNlon:ThiawamnryshaR remabbeHettfora period offiva 151 y<aa on Model SF and ten 1101 yennmalloNer Wr>-Series modeha/terthe dao he SkylgM h purnased a the d ate the eking M H delivered b to a hnt consumerrowneo whinem U bter.On<111 year on Nttt do mmpone G Waaanry Appli<mion:This wa,ranryepples onNathe mate[la6aMladi<ationolthe9Ylghtanddoes not appy loanydefettordamaga ausN by hnpvpervu.MyWerlmMlbtbrl.Mproperc>,e.shipping damageorao- /L cWenLThlswarranrydoa notmveranycamelc<hasgobskyllghl including but not llmitNmpininghadnq paimRnlshdixdoatba CaMensatlon ordamaged cawed bymndematbnlsnacowedunderNiswvranry.D. `? Frame roofopening using 2 x 4's as headers-cut two 2 x 4's to fit Parbrmanu by SunTeb Dudrg Ne warranty perbd,SumTekwill provWe hee of name aneRuivalent newskyligM lormmponent tM1ereN)forone lound to bedNenive In maurialarwohmanship.5hlpping tom of sun eepla<e" en otthe asponelbgiryol5un-Tek.SumTekwill notbensponsibblorany<osuofremoval o[re-bstalletIon.F.Validatlanpruedun:Toohtaln pedormanaunderU,hwarnnty,lhepurthaurmusnlllOnlnstalled nyligRo, the actual distance between trusses/rafters and nail into place. < Is k, lnnru<l—mietoreamovlty1-1lghbRemovalol&Ih.hthamroolbI.,uId nNon will S.Waalonnhth Notify SuoTeklne,eul golany clabtypod thbryD tl ,,herthe N,AIpdixorered;1315un-.F. oritsauNo,Redagentsmust VURRe TES,INCL InstalledphotographsE the IMPLIEDWARt WARRANTIES FNIE to InRTAGIctbnwDFIT ES defect Iscoveadbythis RPOSEry;and(41presentD BUO therEDURATON OF p1E7PF E. Impllad TIESP tlVIDED OWPRRANTIES.INCIUDINGBIRNOr LIMBED TOIMpLIE.IPUNI nanryFMERDIANTA81lRY ANOinNESSfORAPARyi G.Icid— .,Uol eulal D..p,sUTNEDURATIONOFE ExPRFSS a)Ifa licable,cut ceilin o pe and build tunnel framin . ANY INCI IENTILO GO HERDN.Some nateetlo not a0owlimltetbns on howbng an lmpONwa,rantylasn sotheabavelimla[lonmay,wt applytoyou 4lncidantalor ComaQuentlN Damages:SUN-TEx SHALLNOT BE WAEFLEFOR pP 9 P 9 9 ANY INCIDEMALORCDNSEDUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT UNITEDTD tDS5 OFTIME OR REVENUE DAMAGE RESULTINGTO OTHER PROPERTY OR DTHER ExPENSES.Sur,s esdo not allow N<edudon See"Ligh[Tunnel Installation Instructions." "e Ilmlatl"n of Incidentalw Pur. endal daZgle o[he�hove'Mk,Uono,eaduei"nmaynotepplytay"u.KE.dueln Warranty:TH3WARRAMYISEXLUWEANDINLIEUOFALLOTHERWAFRA nU.T l,warrantygivnyou [iA,I Irl NU.You ma have"therd htewM1lnva ft=.ve titanate. All installation Inlormatlon is supplied in good faith,but without recommendation to Its use.No gquarantee of the results of any use of this Q Information is to be implied,since conditions of use are beyond our control.Please consult local buifding codes for compliance before installing. 2224 3114 5 Build curb(or use Sun Tek's pre-built,pre-flashed \ 25.312— insulated"Labor Saver"Curb) —� S 4.000 I a)Construct curb with 2x4's,2x6's,etc.(depending I _ on height desired or building code requirements). Curb should be minimum 4"high.Be sure inside measurement of curb is the same as roof opening 5Q� f lI o measurement. S o 6 g f O Y N b)Secure curb to roof per local building codes. Build curb as shown in drawing.This is the tested/ approved method. I CMA-D-4689 18 FASTENERS TO CURB 6 Shingle roof up to bottom of curb. - I n 7 Flash curb(or use 5un-Tek'spre-formed,pre-cut Step N� m Flash Kit with one-piece head and sill.Step flash for2x4 curb only).Use galvanized sheet metal,aluminum,or copper.Metal should extend a minimum of 4"over shingles(on bottom side),then up sides of curb. Flashing should be flush with curb top.Flash curb to RPJETS comply with Florida building code. 48 POLY TO ALUM 8 Shingle up sides and across the top. 9 Apply a'h"wide bead of caulking on top of the curb around the entire perimeter.Sealant applied too close to the opening may"ooze"into the opening.Can also use 1"wide by 1/8"thick butyl tape,if compatible. 6.050-1 4.828 I .6250 10 Set skylight over opening with the"THIS EDGE DOWN" MAX.VAD label at the bottom of the opening.Screw into place \ \mxi through the pre-drilled holes in the flange with the N12 x 2"phillips pan head screws provided(See Fastener OUTER DOME.118 POLYCARBONATE Schedule).Fasteners must be perpendicular to the curb. 9 112 X 2-PHILLIPS PAN HEAD SCREW Every installation hole must have a fastener. � DECO RING 11 Interior Finishing:Run drywall(or other finishing 7 material)up the inside face of the curb. \ `INNER UNER.080 POLYCARBONATE MEMBEDIN. - - - - - - - FLASHING - - - - - - - - - -- -- REQUIRED 2X SYP min.epecific --;? gravity G=0.55 /10x2 deck screw - uNfl 5/8 min penetration ;.'iz. ROOF DECK