HomeMy WebLinkAboutProduct Approval RECEIVED
NOV 13 2017
MIAMI-DARE Department Permitting Dep MIAMI-DADECOur1TY
St. Lucie County, FL P ODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECO SOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
DAB Door Company,Inc. FI CUA PY
12195 NW 98'Avenue
Hialeah Gardens,FL 33018
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In
Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or'
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined
by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION:Hurricane Master Model 824/811 Steel Sectional Garage Door up to 9'4"Wide w/
Window Lite Option(DP+50.0,-60.0 PSI)
APPROVAL DOCUMENT: Drawing No.01-09,titled"Sectional Garage Door",sheets 1 through 5 of 5,
dated 02/01/2001,with last revision K dated 03/21/2016,prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad,P.E.,bearing the Miami-Dade County Product Control renewal stamp with the
Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING:A permanent label with the manufacturer's name or logo,manufacturing address,model
number,the positive and negative design pressure rating,indicate impact rated if applicable,installation
instruction drawing reference number,approval number(NOA),the applicable test standards, and the
statement reading`Miami-Dade County Product Control Approved' is to be located on the door's side track,
bottom angle,or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the
expiration date may be displayed in advertising Iiterature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#15-0317.02 and consists of this page 1 and evidence pages E-1 and E-2,as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M.Utrera,P.E.
NOA No.16-0330.02
MIAMI•DADE cour�rr Expiration Date:August 9,2021
Approval Date:June 23,2016 t
pG6z�lL Page 1
DAB Door Company,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 01-09,titled"Sectional Garage Door",sheets 1 through 5 of 5,dated
02/01/2001,with last revision K dated 03/21/2016,prepared by Al-Farooq Corporation,
signed and sealed by Javad Ahmad,P.E.
B. TESTS "Submitted underNOA#09-0128.04"
1. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94
2)Large Missile Impact Test per FBC,TAS 201-94
3) Cyclic Wind Pressure Loading per FBC,TAS 203-94
4)Forced Entry Test,per FBC 2411 3.2.1,TAS 202-94
along with marked-up drawings and installation diagram of a DAB 824 24 GA
Sectional Garage Door with Fixed Windows,prepared by Hurricane Engineering&
Testing, Inc, Test Reports No. HETI-08-2149A/B, dated 06/27/2008, signed and
sealed by Candido F.Font,P.E.
"Submitted under NOA #09-0128.04"
2. Test report of Tensile Test per ASTM E 8,Report No.HETI 08-T182,prepared by
Hurricane Engineering & Testing, Inc., dated 12/23/2008, signed and sealed by
Candido F. Font,P.E.
"Submitted under NOA # 01-0516.03"
3. Test report of large missile impact test per PA 201 and cyclic wind pressure test per
PA 203 on"Sectional Residential Garage Door",prepared by Hurricane Engineering
&Testing,Inc.,Report No. HETI 01-974A, dated 01/29/2001, signed and sealed by
Hector M. Medina,P.E.
4. Test report of Uniform Static Air Pressure Test per PA 202 and Force Entry
Resistance Test on"Sectional Residential Garage Door",prepared by Hurricane
Engineering&Testing,Inc.,Report No.HETI 01-969, dated 01/18/2001, signed and
sealed by Hector M.Medina,P.E.
5. Test report on Salt Spray(Corrosion) Test per ASTM B 117 of a painted G40 steel
panels,prepared by Celotex Corporation,Test Report No.258592, dated 08/17/1998,
signed by W.A. Jackson,P.E.
t 4
Carlos M.Utrera,P.E.
Product Control Examiner
NOA No.16-0330.02
Expiration Date:August 9,2021
Approval Date:June 23,2016
E-1
3
E
DAB Door Company,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
C. CALCULATIONS "Submitted under NOA#14-0814.04"
1. Anchor verification calculations prepared by Al-Farooq Corporation,dated 09/22/2014 and
07/24/2014,signed and sealed by Javad Ahmad,P.E.
"Submitted under NOA #09-0128.0411
2. Anchor verification calculations prepared by Al-Farooq Corporation,complying with F.B.0
2007,dated 12/19/2008, signed and sealed by Humayoun Farooq,P.E.
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources(RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 15-0915.08,issued to SABIC Innovative Plastics,for their Lexan
Polycarbonate Sheet Products,approved on 12/10/2015 and expiring on 07/17/2018.
2. Notice of Acceptance No. 14-0311.08,issued to Insulfoam,LLC, for their
Insulfoam Expanded Polystyrene Insulation,approved on 08/14/2014 and expiring on
11/29/2017.
3. Notice of Acceptance No. 11-0926.07,issued to Dyplast Products,LLC,for their Expanded
Polystyrene Block Type Insulation,approved on 11/10/2011 and expiring on 01/11/2017.
4. Notice of Acceptance No. 11-0926.06,issued to Dyplast Products,LLC,for their
Dyplast ISO-C1 Polyisocyanurate Insulation,approved on 11/10/2011 and expiring on
01/11/2017.
5. Notice of Acceptance No. 15-1203.04,issued to Cellofoam North America Inc,for
their Expanded Polystyrene Block Insulation,approved on 03/17/2016 and
expiring on 02/24/2021.
"Submitted under NOA#05-0228.02"
6. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per
ASTM G155 of"PVC Extrusion Material"',prepared by Hurricane Engineering&
Testing,Inc.,Report No.HETI 04-A002,dated 09/27/2004, signed and sealed by Rafael E.
Droz-Seda,P.E.
7. Test Reports on Tensile Test per ASTM D638 of"PVC Extrusion Material",prepared by
Hurricane Engineering&Testing Inc.,Report No.HETI 04-T251,dated 11/29/2004 signed I
and sealed by I.Ghia,P.E.
8. Test Report on Self-Ignition Temperature Test,Rate of Burn Test and Smoke Density
Test of"REHAU non-foam PVC extrusion material",prepared by ETC Laboratories,
Report No. 04-761-15019.0,dated 05/06/2004,signed and sealed by J.L.Doldan,P.E. !
F. STATEMENTS
1. Statement letter of code conformance to the 5"edition(2014)FBC and of no financial interest
issued by Al-Farooq Corporation,dated 03/21/2016,signed and sealed by Javad hmad,P.E.
p`�I � i� t
I
Carlos M.Utrera,P.E.
Product Control Examiner
NOA No.16-0330.02 i
Expiration Date:August 9,2021
Approval Date:June 23,2016
E-2
3
3
1
3
7-1/r%3-x.071'GA1U.STEEL TOP FIXTURE 5-1/2•%2-3/4'%0.1•
END ROLLER HINGE _ _STEEL PLATE WIN ONE 5/16-IB MS W/NUE
IT 7�
W/(6)114 5/8'EMS /FASTIN11 TO END STILE*'W OPfgNN-DOOR ,I,"
WITHOUT OEIAON SLEEVE(SIO) �p (6)114%3/4'SELF DRU.N _I_
TO BE NTTAUEU AT �r-" �•/1
wim DEIRON SLEEVE(OPDONALj CENTER SR E I Z m
r `
n
CENTER STILEA
Q
t3
_�_
e ]-1{2'%2-1/4"%.0]1• i •` -! ......._... ...._ I? _-- O�Ce�,
CEh ........._...._
`t o 04..'4 STEEL TIA HINGE _--i ,'
F � IIYY�S
W/U)114 x$/B-GUS t ,�i�q I f
............ ri
WITH DELRON SLEEVE(OPTIONAi) 9 _..._ -_1_._...__-! _ 0 z S "66 i1
`. 2�DDDR i �.� '(_.
, I I•w z.15*Tf9c.utaH
�L STANDARD LOCK ` .�x•.• -_. - -- •eP I m
` SPRING LOADED SLIDE eO:T( ,.4 SIDES) — 0'
FASTENED W/(4)114%1 •S.MS. `-r'•"'9=a "' '—"_ 0 o
5/8'VA LOCK ENGAGETUENT �.��.f '' ........._......1.. e< �I....._._..._,
_CONFORMS 10 SECTION 1008 REGANDIN.GNEACC DCORS i i US k 6 J
C3
♦ ____ I I Kp.
IInOR HCICRR c21Mtm a • `♦ �_—, I -- —,=._...... I 'a C U1 I
..w.-.le.......f1YCTAING 16'1 5[CPd,19_I+' .158 DnL GALV.NRCwT TYPE ` i �(
oZ.0
-S' 1 SEC,10l1 te"iJ 6RLODN61,' h NNS-PRESS EE`l_ I - A +F
ccr 5L `l `Z �
W/AgTI.5 TO 1 SAFETY FACTOR! ,l i \ ( YE AT I 0?fIgN.4 RELISH FACE 0 z
.......... ' i o�
S W1f:E 7 D.0 IIA%. t
O 'a NiEA NOT TO ETtCEFD WOOD GRAN CES[%N W ate'
r-J• - I- 120 50.W. [COLONIAL OfS1ON
T-!' S S:CIIOtS 18'e_ 6'x 3'%0.1•
Y-9 4 SECDp6 8'•1 BERIM 21 I
v J SECIDI6,e•2 WON'
]1R� WITH(2)114 N%8*PLATE
`♦ll MA%.DOOR WIDTH
-r T SEC6Dhs+B'J SFLrION6 21' O _' 9•-4•
6•-e' 1 SEERS 1e'it Sorg b•i --___/ ``-__1` • ?
Ir-n• s sEexDla Tr:- BRACKET BRACKET INSIDE ELEVATION
e nECbIG,e';=' SfD.LIFT DOOR LOW HEADROOM
DOOR OPTIONRAISED PANEL EMBOSSED ODOR t r
9•`,1- s scc+D�16•:1 sxcnm_11r"
e'-a_4 II%IIOAa 16.3 SEC110.K 21'
ssTs:des W"a"s"rcnons Tl• ]-]/B•x 3-1/6'x.Oto• Ia
IT �
�
+,T a—Sle'4 sEcnoss a+ LW(TH Puff JDAH D00H3 LNC.
TO-r 1 6TLTICN 1a s 6E 0"2t'
CENTER STILE W11H(4)1fa%3/a'SOS
1D-6 6 SEGTIDAS zl'- Hurricane Mosler$Mod-!624/BI I n10'
to'-9 a SG—.le•1 EF%IIDN 21• olasloE 114%3/4'SELF DOLLING SCREWS MAY BE USEOj Mcx.Sire 9'-4•%16'-O-Higx
11 D SECRD.IB'2 5£CIY%S 21'
PAN LEI EIA SALE IN UEU OF 114%6/6"SMS with window Ute Op1bn �qg 3 g
11'-]' 4 t2CIl0N9 IB•3 SECTIONS]Y '
n•-s• .ps?tTlolg
_ ie'4 ,215 — DESIGN PRESSURE RATING o+ 50.0 PSF I
iP-O'_ 2 ffDTMNi,e's.urnmRs ar +
THIS PRODUCT IS RATED FOR LARGE MISSILE MPAL71 _ -
I I SLCRDNs,e•a SECTIONS TI -INSTLOCK BAR GUIDES - 60.0 PSF I ,
la-s a sEc11DA6 21'- ^- --
STILE
,2•-e' 6 SE'CIVUS :slrno+s 2t• + INN(4)1�X5/e's S GENERAL NOTES PRODUCT RENEWED IB' 2•
_......._.___.__..__._ n 66 compltring wllh the FIDNdw
1 -a" 6 MCDDN]1S J D•21 S 21• o .19T%.6N LOCK BMR L THIS PRODUCT HAS BELT;DMGNED AND TESTED TO COMPLY MR!THE a0ugdllg
n' •SFLTOIH iris SLCtW1+5 2t' EN WOES IN?PACK REOMRENTATS OF TEE E14(STN EXPON)FLORIDA EI.IU)ING CODE:NCJIdNG Moa-TED. 16-0330.02
,s'-)' .3 SECTIONS le'16 5[CIMNs 21' ON EACH 51�OF ODOR NIGH VOWTY HURRWIE ZONE ONHT). 00/0912021 S, I ! 4 1 T
IJ-6 1 5£CRG1S 10's SfL1M,S al 2 ANCHORS SPA BE AS USTED.SPACED AS SHOWN ON DETAILS. etptratfon
Ir-) .+SECTION t6'i7 SECTORS 2t• OUTSIDE KEYED LOCK(OPTIONAL) ANCHOR EM
BECMENT TO BASE WTEIUAL SRW.L BE BEYOND WALL
14' �e SECn0N9 21'- LOCK FMR IO(2KIIq OHCYH ORESSSNG OR STUCCO. By
,a-3' ie 6ECM116 le' 61LTIIAN6 31' ALTERNATE TO SPRING WADED SLIDE BOLT S
ALL BOLTS.NUfE AND WASHERS 91411.BE LNC f%lATEO CARBONSIFiL M Pnduel Ceetlol C I k
t4'-1 SECTIONS I6-4 SD.•IID_♦_'S 21' LOOKS SHOWN NEGATE 4. ANCHORING OR LOADING CONDITIONS DTHUR THIN THOSE SHOWN IN
,4'-9• eernD.s le•s smivs ii' L.-
___tS' a SECIbf6 le•a SRTIMS x+• ARSE D OD.SURU ME NOT PART UG TRIS APFPOI(or
...IS'-]' ]SCCEN16 16•T SCRONS 21 5. A 1040 CIR4110N LVN05C IS DFA W 63CN OF ANCHORS INTO NMO ONLY. /!T� drewi IB
IS'-6' 16ECTION 1e' 6 SECRONS IIt ...I'LO...._. )
p� TIP
9 SECOONS Tl-- D02N 1Sff9 g AS-20Z TA NRH TFT:TAS-203
EFOR OF FLOROA
___—._... i.n,TNG CW£TAS-20Z 1:1 TAS-TOL bTAS-20J FOR 1M12 ANa �1
1B' (8 6FLR0a6 1B'4 SEC11QV9 21' ;ASd E186B-0.5/ASM EI9aS-09. I 7 ORAL 1 '
24"STEEL PANEL i11
5/16'ASW FVVIETS,
Z gip'
0
MPsSE14T OVER PANEL
,u4cm"SS
024'STL PANEL B 4'(KC
DIRSroE OF DOO
12
STEEL TRACK FASTENED SOLID BRASS 099A—MIEVIER
M WOOD J&Yg NM By'scHLADE muNny HARDWARE'
5/16'X 1-5/8'UG SCREE- INISTALLEZI IN 9/16m DW TALES 114 EDITOR STILE
1,;"ly=5111 POSMONED AT EYE LEVEL
ANCIIDRS AT TRACE BR 0
Oprioli.l STOP.0"a
MR CO—CTION OE I,IOOD 9
K BY DOOR INSTALLER 2'MR.MOM KM CONCRETE
70 UASONW SEE ON TREET 4 1-7/13'M EXE OWANM
tf
PER :Id
X 5/87 S5143a;X 2'X 2-1/2"X 18 W.57M a)
"E STLE.CVNNECJ 70 PANELS
SOUTHERNE 1,12 9'M-11 FLAPS ANI 111W-N"I'S' I ,ELEEI T.
'-3/' `5 16IlN.EWE DIST.OETNN M�
..: .. . N.N.g�'M'o""`*N...
PA4ELXA..SECURED. SEE DUAL AL13VE 5/8
•WIN.CD�Z DISTANCE P"PUED LOCK o o
0- D?W END STU wITm 3/,.'POP Xmis 12'O.C. 4
Z
ru
-5/8*X.045'STEIE. CONM r. 3030 PS!UN.
EDGE
Y.2
snr-ow ANA,RIVETED OmANCE C-90 GROUP FILLED BLOCK r.-nW PSI Mill.
12 A-
4/PWGE
<11 , ,. L>
70 EL W/(4)3/16'RMS
POP.WETS
I i14 x S/8'S.N.S. I
/.R TYPE I OR D
1.9'X 2.19.X 13'X.102' U I..�
STEEL TRACK PACKETS M
54EET 3 R 9FAUF,`vm
A
SEEG Ulf III I
SHEET 3 MR SPICING01 k-11/4--20 SS GOLT h NOTNis i
F19
7-1/2'X Z71"CALV.
CENTER '7-1/2'X Sy"X.071'
END RDUXER HINGE
7/19*PDVNUF.A SECT ON
IWX=ON ROLLER SHA"
STEEL
..........
INTERIOR SIDE .82w OW X.50'STEEL ROLLERS(SIM) PRODUCT RIENEWEID
'14:X 1:�I/,l 2.75.TRACK 192'OW X Me NYLON ROLLERS
M"STEIL RO ,S
OW X
O,T,oN,,) "0AN** 16"0330.02
TASMW M TRACK PLIIIES 2.75 D.x.50'NYLON
g/=Xtsilow W. WTTH G*STEM Exp 912021
staNII TI IT, C.hi�m_z_.f 5
V
-PCI IA£52%2%1/S-NORM ANGLEi
2' 5/16'N 1-5/8'LAG SCREWS I,YTO NOW OR`- NO0.R.TRACK SUPPORT, SPDT A?;yCEO 10 WRL TRACC
1-]/4'%5-1/7'%Y%.104' 6 18'SIEELR ANCHORS CENTER SUPPCRf RmO.ON DOORS
f WLv.sr:JL / vA.Tx TWV WJDs ar 1-1/2'APA0.T i
A TOP ROLLER ExUCN[f ON Fi111 SLE NBit 1-1/4'Q1331 iPOED ExFEEOJC 0 FT.IN NJCNi FlRSi AT 3'O.C. ------
DAD
-_,!I
FASIEtfm N/(B)/II%5/6'SHS. _ 11� A— REST AT 9.O.C. „ m
! I , CONNECTED TO ilAO BPACMEi ANQE Z
090 THK.GALV.STEEL ADAWA91£ - - _. - ._ N/3/e-16 x J Q
AIDE FASTENED TO BRIM 2-1/3'%4-1/4'X 1J GA STEEL MATES t AND 10 S-m� KAFT NO:.Y1iN '0
N/5/16-10%7/a-HE(F'FAD WELDED TO 1-1/2'%1-1/t'N 11 GA ANGLE A (2)?/t-ED%SIB'BOLT R N4T f t
4.SCREYa @ MJfS FASTENED TO TRACK
TOP BAACIRT WNM(4)1/4-20
W.
BOti tr N� -- EK)RR.TRACK LENGTH OPEN'NG HEWR PLUS 12•
(WANWRD) \ - � �`�
TOP®UCKET 11
(CPT. ...j. vz. 11 TRACT, ti u
t LOW HJJROOM DOOR - 14 GA CAL'J:STEEL TRACK 2-1/6'x 1'x.Cal V p "1
3 \ \ __ ! SECTION A-A co, i
"a \HORZQRAL�!roRLTxJRr
\t/2"%T-J/4•% FASTENED
STEEL 2'X5-1/2'%.t0a' 'C C
u L{ QDED TO PANEL AND FASTENED TO OALV.STEEL _ ! d ti�6 j 1
m YER!CAL SIECS nOH fA51ENm N/((4 14%5/8 SY9. ! ?0
a ('<),l1le P RALn 40P)FOLLL4 BP3LKET FCR Q e l t
LOW NFADDR000ll DOOR CPWN DOOR f-•SECTION HEIGMS BRACKET PUCRIENS
HORZONTAL WNFORCEl1FM Y IlSf 2ND 3R0.47M SiH; 01 B2 BJ F B4 85 O6 07 B9 a d
1/2'N 1-J/4'%459'TDRNSTEEL j 6'-^.' IB"Ill 18-'18 A 1-TO 2'11-7/4 2J' [ I.
45• 56" W' - P j
CLUED ID PANEL,X4059'
NO m FAS:0"TO 5'-6' 21"10'10'121' /1'TO 2'11-3 Y'
YERfAAL pDp FAET _..._. A _�_- 2J' F
' - (2)J/16'POP RNR; 7'-0' 21'21'21"121'[N/All-TO 2"l l�14" 7J' 56' -67' _--
5/16-MFEON0 WB 1B'1B' 2J' 3C ? 45" 56' 07' 78-1/4-
i
B'-Y 21'19'1R'18'21.1'10 2'11 '!
182-DA x.50'ROLLERS tt -SECP.C4:3 ARE NLIUSERED STARLING AT THE BOTTOM m I
O W/.44 DIP.x 4-1/4'STEM p,�j EE
FOR DOORS NORE THAN B FT.HIGH,USE Awro%AL TRACK 9W.GhlB AT 10'O.C. n p
O � o n
OPTIONAL mlATTpRSc Ta a LL i
Br'rnxAu EI
STy-ops-EXPANDED.0 POLTSIYRENE 'rA U UI ry i
OENSRT 1.0.5 PCF ST x LID-x JS%'.C9Y r
NAA+11-0926.C7 ST.].TRACK OItAC1(RS II U ?'-
2-3/16'HIGH W w
'ry OR
LSO-2.5 POLNSOCTAI.1, Tb rvECIFD l0 1pAfT(WRU - m 2]
DENSITY-2.0 PCF 1)1/4-d?LTS a NUTS. C3 5
VAIL/11-'J926.C6
V 4g
'CEIInEC EI N0Mi --;X L:
DENSITY-1.03 FG"
N.OA{T5-1203.04
m'
DENsnT FIN-WY
-as2 Pcr
N.OA+14-0311.06 �gp
Q 14 CA GAL%STEL!.
ROLLER II!NGES fAS.ENED _
W/(4)/14 x 516•SNS
II k Flayy 1
wN..024'fN11 rowEm SfR1 PNlJ. ISI I� 11 d
DRAVN'OUAIRY C-40 I I q4) 1
MBA 11JD S(RENGTH.34 KA
M:TH PRIMER AND EAKm-ON TRACK CONFlGURATION
A,Pm TOTO°Na-som D TOP or STE71
a� VERDCAL LIFT H[GH u STANDARD UFT LOW 4FAOROOM o
m' DOUBLE TRUK --
12
12 GA MY..STEEL 1 1111 r - if T
eoTrou
W/(4p u x s/e'
PROODUyCITT RNENN�ED�o
PA�
BOROUN SfAL O"OA NCIA-ND. 16-0730.02
i "sEE SH27 4
E1mIrAt1 00!0912021 Y ;p_
SnNm a r,D6YCE cmllTsl '.•SF Rammp� C' 01—09, i
SECTION A-A /OVALE '
r EE111IT T1 sheet 3 of 5 S
i
...7/9•X 1-][4•X.OW �V 1
'. FORMm aTEEI
is x I-
SOU,
o'
/ S'SF ORILLINO sGBms 1 ! (B x 1• - 1'
1-1/2•MR. j OR SELF OBTUND SV,m' 'L
S a I E DL1T. i v 3/1C'RNDf STEEL PoYLIS OR 0
MULTIGR,P W/DOUE I'm 3/16•'aNEx'S�F1 RNEiS
AT 4B•O.C. MUITICRIP W[OCHE.0 F
/ ! \ •T `Y/ \ ry R[1NNRCEM4R AT 48'O. a g �
��. tn•%,aFCJ/B'4EU STEEL..� a• •••��ECCC!!!ttt Ly:
1 1/4'DA NO STRE>r I[4.OIA WL sFAQtS ' _--' O 1 y
W000 BU !Ii -AT 6'FRON ENDS WOOD 0 li AT 6•FROM ENDS ����///'/ -t
I 1 XmI 1B'OO.YNL i 1 ANO 19.O.C.MAK F. I gt N A
' , '"•-' AIULiNUM ___ SFE].'Ar1NFFli OQO i
Ruegg N'STUPPme
j `aUgIFR WSTR;Pi.NC
050 .040 m-a.700
'.
LSA
�` �I I� I
�(
OPTION'A' \J OPTION'B'1L BOTTOM SEAL OPTIONS
Ir m
WOOD BUCK CONNECTION TD WOOD SUBSTRATE(WOOD SPEC]RC GRAM SG-0.55 LBH.) 0 c
TIE!NSTAWLDON METHODS SNOW-ABOA:6TFOA5 296 SVP WOOD BUCK M'TAG %T O 'O
TO WOOD SRUCILRES.F THESE UFI IODS ARE POtLCAT;D NO ADDITIONAL W:CU'JOIONS/CESICN
,
MLL BE REW-KD FON DESIGN OF CJ4U0E DOOR ANCFORACE
POI DOOR REFWCOAETFT APPUCATDNS WON NO ENGD:EER OF RECORD.MTH ION MAY BE I 4-CADR 6PAClVG ' (J S
VRIFlm AND APPRINEO BY 7K dUILDiNG ONIOAE UPON INSPECTION ANCHORS STaUCa.. EM6£O EPACINC LOGE DST.; V 2"DN
HLC_SLEEYE DY N:LII CONC. 1-1
�Jfg_11C SLFIIVE Bf NNW FI;Lm S-1-,[4_'e__ 4' 1 ¢. m
-7/8'ORIMQLT B;I.-IOt CCNG. 1-1 2 G,
2'�
STEEL STRUCILIR-BY OTHERS l 3'pYNA90LT 13(pW F41_c0 BLOCI(1-,2 B_ z-I a .0 z=o
5/16'X t_g/s• ]9 WFEa-BOu 8Y'PG1nFfiS'�--C@1C. z• 9•
VF SC lY5 / OCOfl �C LOA05 IMPOSED J -ALL BY SMPS— CONC.
AT 12.O.C. w
N
•
ODO PSI
C-90 GROUT FILLED BLOCK
I*.
a 2000 F51 KN.
- S/I6'
WOOD BUCK CONNECTION TO MASONRY 's' WDN WASHpi D rcm
AT 12'O.C.Wt.
P.RFSSURE TRFATm 2%0 SYP WOOL.IAMBS Wf0OF CONIC
BE UN WIN TO � I 'ice Em DIV.
DI,S'T,_.__�
G20UTE9 1m*BDacm LLASDNAT BL'1LK Wll OR DWIE COLUUX KM ' rg
ULT. ON BY'ELOO'W:TN SP=NG OF I pI
OO.RIM GFOUT FILLED BLOCK HALL.SWM 2-1 4•MPF.Fm
ILEV qq
IB'0.C.PRO 3m0 PS ODt.RETG WON 1-3/4'MLN.ENgm I V a Lc'
2-i/Y LLP4.m¢OLSTANCE T-1 4'X 2-/ X 14 G o.
-T/z' -I/s CAN s EL AC E -t/r
I/
4.1AF'PE0.ar•I>OIR':RS'WTnt SPACING,of i q�i�Nl
14'0.C.F.RIO GFDU1 FILLED BOCK WALL.WON 1-1/2'NN.EU3M - 12 W WLV.StEF1 -—' 2-!8"X 1-%14 M )
46.O.C.IMO Jm0"4 CONCRETE.%"1-]/r NI CLOm I/16'%2-In FLAT BRACI(ETS t!'LOUG CAE STEEL 1RACK 24'8 �$�
S MP:EDGE OSTAN¢ FILLET WELDS AT 1Y O.C.A DOOR ORY FASTENED M IRADK RATES
J/B'CON:IDI DY TDto'CR �' AT Ir O.C.YNL �/9J!I� AT!B'O.G Aa
COOK OPNG. W/(R 144-20%$/B'TRUSS:O,
]/8'lDT BY'iN/NITII SPACE\'G OF �J �/`__CONNE:Gim N COM.ANGLE SLOT7ED .S 8 LOCK NUT
2r O.C.FTO 3000 P51 CONCILLTE WOH 2-t/2•uW.ENDED W/(0)SPOT WOOS m EACH SIDE _t
2'UJi.EDGE DISTANCE GOT. IOLIS AN Ac M&K ReyERSE TRACK gMUMUDLS ANG:r 115m
3/8•HLO SIPLYE BY'SU'WIM SPACNG OF TO W000 ALmR TO CGI.RETE AN,40 Ell lm alem
B'O.C.INTO CROAT FILM BLOCK PULL,WIN 1-t/4•LLLN.EMBED,4'4W.m¢OST.
10'O.C.INTO Jm0 P9 CONCAETT;WON 1-1/4'YIN.EMDEO AVO -
2-t/2'ITN.EDGE DISTAFCE ALTERNATE TRACK INSTALLATTON ( '�'�f if
PREPARATION OF JAL(RS RY OTHERS F 4
FOR FR"W COISIRfICIION DrA EM OF RECORD Oa AROPTECT m VE18Fv PRODUCT RENEWED
• "C,'O
14,
l itA tM FloHda .
BY ODOR OF SUPFTXtiNG SIflUCR1RE TO SVPFORT LOADS 11�0'EO Iq
gFt'YtDOOR EPPLACELFtiT IN REINOFT BUILDINGS WRIF NO ENCNET3L OF OLN.,aa 1E-0330.02
RECORD,DOOR IFSIAVATWN MY BE AMEND)AND WFR02O BY
BINWAG OFHCWL UPON INSPECTION. B.Wr.uoD bOB10912021 D, T�F(/y- rkOvring Iro
1AAXINBN EXBERUR(+)lfJAO PER.ULB (93J'Y 50 PSh a A/2=]alDe ger FL .s x801; (A\` II(L�-Q�l 0
LWLB/W INR¢OP(-)LOAD PFA JAMB�(93]'X 60"/2-279.9 Lb. FL
Ft11IIt A heat 4,_of 5
+PLASTIC COMPLIES WITH
oGM awn CHAPTER 26 OF FBC ��Q
24 GA(AM)STUX uer. SEE EVIDENCE PACE
Lqq7 w
1.765 1.]7S ' I4 as 4
7/16'CIA,nASNEN
I LI Q j yyj e^1
21 3/47
M. 44Y .176�i
J j, ,i AND 7"O.C.YAX. I x'CYV.Hlof!1 4 O
i '{• I k EXTERIORPCCE tKJWMD
)PRIOR FRAME
R=LYO I p o
ONE PICCE INJ[CN ILC ONE PIECE INJECTION LL Z�„•G
q{ r
Alm 6-1/r7O.W)7a M�1/a' Fb '8fl
vAx.
±iOAE
i rl 175%.062 LEEP
EEI- ra: I
-
o 0
rSA,NG O
'it 114 +OYCO m
INNWATW . Y�LLj
FlA5aC5' n �
E:l s mmo 1
cr' n
i
Ilj
li'i "e a Ip
ED
S
,175 X.061 DEEP y`
w i (4)/9 x]/r sus INSIDE ELEVATION
o 1a/B-FRCP ENCS RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS
� � I �� WINDOW LffES CAN BE IN ANY LOCATION INDOOR SECTION I I
IS%3/4"SYS
]/8"FROM ENCS- f75%.082 DEEP
AND 4-f/2.O.C.1441E -
O]/B• ENCS _ ---'�
Anoro.0.c wX. r1,r 4
_.____----__________ PRODUCT RENEWED '
7/18'OLt wISNER :
------ hcompl1�Nry1 MNIIro FbrlAa • ••• •• oli,
„
j - Bu{bOng COQ -
--`------ NOA-Na 16-0330.02
I 24 GA 024 Sf�iL� EXTERIOR EIrWmNen o 08 * 11 $
COM PAYFL 4 ) u/18"41x. at10912021
c-- r
.Om ey J ero.inq
• 24 cr.(M4)S=uta cXAnNc ela a1.m rraaY�E 4fo1 •. a�?��`i O1—09,
wmDOW 1wu
��OMA6 aheei 5 of_5)
f
I