HomeMy WebLinkAboutWind Load Calculation FLORIDA BUILDING CODE 2014-5th Ed.-ASCE/SEI 7-10-WIND LOAD TABLES' fA (! }F' Enclosed Building with mean roof height less than or equal than 60 Feet EXPOSURE C AND D -LOAD FACTOR:0.6 INCLUDED N O V 1 5 2017 WND PRESSURES IN PSF WND PRESSURES IN PSF 170 MPH VELOCITY-EXPOSURE 170 MPH VELOCITY-EW&WQ.... Building Roof Slope less than Roof Slope greater Building Roof Slope less than Roof Slope greater Height 10 degrees than 10 degrees Height 10 degrees than 10 degrees Positive Negative Positive Negative Positivel Negative Positivel Negative z4&z5 z4 z5 z4&z5 z4 z5 I z4&z5 z4 z5 z4&z5 z4 z5 0-15 34.6 37.5 46.1 37.8 41.0 50.6 0-15 42.0 45.5 56.0 45.9 49.8 61.4 16-20 36.8 39.8 49.0 40.2 43.6 53.8 16-20 44.2 47.8 58.9 48.2 52.3 64.6 21-30 40.0 43A 53A 43.7 47A 58.6 21-30 47.4 51.3 63.1 51.7 56.1 69.3 31-40 42.5 46.1 56.7 46.5 50A 62.2 31-40 49.8 54.0 66A 54.4 59.0 72.8 41-50 44.6 48.3 59A 48.7 52.8 65.2 41-50 51.8 56.1 69.0 56.6 61.3 1 75.7 51-60 46.3 50.2 1 61.8 1 50.6 54.9 1 67.8 51-60 53A 57.8 71.2 58A 63.3 78.21 LCCATICN BROWARD COUNTY,PALM BEACH AND OTHER LCCAnCN BRDWARD COUNTY, PALM BEACH AND 07M � EXAMPLE COUNTIES E7cAWLE COUNTIES WND PRESSURES IN PSF WND PRESSURES IN PSF 17 5 MPH VB.00ITY-EXPOSURE C 175 MPH VELOCITY-EXPOSURE D Building Roof Slope less than Roof Slope greater Building Roof Slope less than Roof Slope greater n Height 10 degrees than 10 degrees Height 10 degrees than 10 degrees Positive Negative Positive Negative Positive Negative Positive Negative z4&0 z4 z5 z4&z5 z4 0 z4&0 z4 z5 z4 6 z5 z4 I z5 0-15 36.7 39.7 48.9 40.1 43A 53.6 0-15 44.5 48.2 59.3 48.6 52.8 65.1 16-20 39.0 42.2 51.9 42.6 46.2 57.0 16-20 46.8 50.7 62.4 51.1 55.4 68.5 21-30 42.4 46.0 56.6 46.3 50.2 62.1 21-30 50.2 54.4 66.9 54.8 59A 73.4 31-40 45.1 48.8 60.1 49.2 53A 65.9 31-40 1 52.8 1 57.2 70.4 57.6 62.5 77.1 41-50 47.2_IM 63.0 51.6 56.0 69.1 41-50 54.9 59.4 73.1 1 60.0 65.0 80.2 51-60 49.1 1 53.2 1 65.4 53.6 58.2 71.8 51-60 56.6 1 61.3 1 75.5 1 61.9 �PE MIAM-DARE COUNTY LW67 ELEOE MIAMI-DADE COUNTY GENERAL NOTES: 1-THESE TABLES ARE APPLICABLE ONLY TO CALCULATE THE WINDLOAD FOR COMPONENTS AND CLADDING (HURRICANE SHUTTERS.WINDOWS AND DOORS)APPLICABLE TO A SPECIFIC PROJECT.THE CONTRACTOR MUST PROPERLY SELECT THE DESIGN PRESSURE ACCORDINGLY WITH THE EXISTING CONDITION AND THIS INFORMATION BE VERIFIED BY THE CITY AUTHORITIES. 2-PLEASE,NOTE THAT A SPECIFIC PROJECT CONDITION IS NOT ANALYZED OR CERTIFIED BY THIS ENGINEER. THE SIGNATURE AND SEAL INDICATED ON THIS DRAWING IS ONLY APPLICABLE TO THE GENERIC WINDLOAD CHART BASED ON ASCE 7-10 PUBLICATION. 3-DO NOT USE THIS SHEET IF THE SITE CONDITION IS NOT COVERED BY THE TABLES OR A SITE SPECIFIC EVALUATION IS REQUIRED BY THE CITY OFFICIALS. 4-EXPOSURE B(Section 26.7.3)-Urban,suburban and wooded areas and other terrain with numerous closely spaced obstruction having the size of single family dwellings.For building,-30ft exposure B prevails in the upwind direction for a distance greater than 1500 ft For building>30ft exposure B prevails in the upwind direction for a distance greater than 2600 It or 20 times the building height,wichever is greater.Based on the FBG HVHZ,use Exposure C when building is located in Exposure B 5-EXPOSURE C(Section 26.7.3)-Open terrain with scattered obstructions with heights less than 30•,open country and grasslands.Exposure C will apply when exposure D and B do not apply. 6-EXPOSURE D(Section 26.7.3)-Flat,unobstructed areas and water surfaces prevails in the upwind direction for a distance greater than 500b It or 20 times the building height,whichever is greater 7-BUILDING CONSIDERED ENCLOSED-All glazing shall be Impact resistant glazing or protected with an Impact resistant covering. 8-ULTIMATE WIND SPEED-V=170(MPPH,175 MPH • 9-TOPOGRAPHIC FACTOR Kzt= (FLAT T TERRAIN) e° �. 10-DIRECTIONALITY FACTOR Kd=.85(Wind Directionality Factor) •o••• p£ •'•.• 11-TRIBUTARY AREA:10 SQF •o° . /�9t'"° L 12-EDGE STRIP(a):The smaller of 10%of the least horizontal dimension or 40%of the •°0 .. ..� Mean roof height,but not less than the larger of 40/6 of the least horizontal dimension or 3 it ° � N0. 52609 v Roo! Slope E N 6 C O,Inc. STATE O= � T Engineeaing services-CA 8118 0�, d F, 1, OFt � °� iz 1791 Blount Road-unit 907 ��q$�� ........ ' �\°••° si z< ' Pompano Beach-Florida 33069 NA ••• 5 «> >° Tel:(754)307-1319 Fax:(754)205-6846 �''•.,,,����e I MEAN ROOF E-mail:EngcD@AOL.com gtl \HEIGHT e" a<=BWx0.1 ora<=hx0.4 BW less or equal than BL DATE: 07/21/2017 a must not be less than PEDRO DE FIGUEIREDO-PE 52609 a=3 feet or a=0.04 x BW NOT VALID W/OUT SEAL 7/21/2017 I Opening 1. Clear Panels ZO (Side Lite). `S 2. Clear Panels, H (Above FD) 3. Entry Door"NQ-SHUTTER" (Front Door) I' 4. Supernova Accordion Shutters Z (Patio Closure) 4 5 5. Supernova Accordion Shutters (Window) 6. Supernova Accordion Shutters "1 (Krindow) _ 7. Supernova Aq ordion Shutters (SGD) 8. Supernova Accordion Shutters . (SGD) 9. Supernova Accordion Shutters g 8 7 6 (Window) 10. Supernova Accordion Shutters 10 t0 a o (Window) -oo a u 11. Supernova Accordion Shutters u m o a) Window) 11 ° 12. Supernova Accordion Shutters h U y (Fixed) 1 y ^ S 13. Supemova Accordion Shutters N ^ Window) jL a 14. Supernova Accordion Shutters (Window) 13 14 c J U CO MU) M M • 5 � of 0 ILLU) � 3S o � � LO COPYWGWE MPEST.G SCALE: NOT TO SCALE DATE' Oct 25,2017 PAGE DESCMPnON: Site Plan PAGE: OF1 1