Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ROCHE - PERMIT APPLICATION
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 11/13/2017 Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT APPLICATION FOR: Mechanical PROPOSED IMPROVEMENT LOCATION: Address: 5051 NORTH A1A UNIT 6-2 Legal Description: SEAWARD AT ATLANTIC VIEW UNIT 6-2 (OR 4012-861) DETAILS INCLUDED ON SEPERATE PAGE Property Tax ID #: Site Plan Name: Project Name: Setbacks Front Back: Right Side: Left Side: 14 � � �� �' m Q_K 0,a Av,-P - Lot No. Block No. Aaaitlonal worK to De nerrormea unaer tnls permit— cnecK an appry: R]HVAC I _I Gas Tank RGas Piping _ Shutters ❑ Windows/Doors 11 Electric El Plumbing Sprinklers FiGenerator Roof Roof pitch Total Sq. Ft of Construction: Sq. of First Floor: Cost of Construction: $ 5321.00 Utilities: I _J Sewer O Septic Building Height: OWNER/LESSEE: CONTRACTOR: NameTIMOTHY F. & JOSEPHINE A. ROCHE Name: DENNIS A. DUFF Address: 5051 N A1A APARTMENT #6-2 Company: ENGINEERED AIR LLC City: HUTCHINSON ISLAND State: FL Zip Code: 34949 Fax: Phone No. (561) 309-2291 E-Mail:LOBOTFR@GMAIL.COM Address: 2520 NORTH ANDREWS AVE EXT City: POMPANO BEACH State: FL Zip Code: 33064 Fax: (954) 973-1883 Phone No. (954)449-1600 EXT: 330 E -Mail: MALLORYW@ENGINEEREDAIRLLC.COM Fill in fee simple Title Holder on next page ( if different from the Owner listed above) State or County License: CAC045860 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: — Not Applicable Name: t MORTGAGE COMPANY: _ Not Applicable Name: Address: Address: City: State: Zip: Phone City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: BONDING COMPANY: Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize thepermit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvemeA to yopr property. A Notice of Commencement must be recorded and posted on the jobsite before the�frfst ins ction. If you intend to obtain financing, consult with lender or an attorney before commen g workktfoor recording vour Notice of Commencement_ Rev. 8/2/17 kkS" Signa of Contra ice o er ure of O nW Lessee/Contractor as Agent for Owner ST TE OF FLORIDA STATE OF FLORIDA_ COUNTY OF ry M P t ► C,t • COUNTY OF iJvyC�rd The forgbing instrument was cknowledged before me C The forgoing instrument was acknowledg?4 before me this � day of ( �W lel i ), 20a by this � day of uCV 0x'41 '-- 20 J-1 by n1 Jia `�U C �W% �f r1�r� I S A . i xi -P Name of perso making statement -"`"" "Name of person making statement Personally Known OR Produced Identification >6_ Personally Known OR Produced Identification Type of Identificatiop-n Type -of tdenti ication Produced ��qt►ltll►Illlfl Produced7� (Signature of Not C+,+- (Signature of Notary Public- StatEgf Florida N i :.%va• ANDREWSTEVENS s.=_ Commission No. : ; Commission 1f Ff(S p� Ex March 17, 2019 ' 2 p F 10786 ' Commission No. ��.� :• 1 ela • 19 - Aires % Bonded nra TroyFain lasuiance 800 3857019 9� . r 0 d aN,0 i //ABC/Ca�STA�E��� REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 8/2/17 Michelle Franklin, CFA — Saint Lucie County Property Appraiser — All rights reserved. Site Address: Parcel ID: Account#: Map ID: Use Type: Zoning: City/County: Ownership Timothy F Roche Josephine A Roche 5051 N Ala Apt 6-2 Hutchinson Island, FL 34949-8284 Legal Description SEAWARD AT ATLANTIC VIEW UNIT 6-2 (OR 4012-861) Current Values Just/Market Value: Assessed Value: Exemptions: Taxable Value: Taxes for this parcel: SLC Tex Collectors Offiw 12 Download TRIM for this parcel: Download PDF 12 Date: Book/Page: Sale Code: Deed: Grantor. Price: Date: Book/Page: Sale Code: Deed: Grantor: Price: Date: Book/Page: Sale Code: Deed: Grantor: Price: Date: Book/Page: Sale Code: Deed: Grantor: Price: View: Building Type: X142 Grade: XSVB Story Height: 1 Story Bedrooms: 2 Full Baths: 0 Half Baths: 0 A/C %: op/. $188,200 $188,200 $0 $188,200 Property Identification 5051 NAIA 6-2 1414612-0024-000-7 137602 14/14N 0400 Saint Lucie County Total Areas Finished/UnderAir (SF): Gross Area (SF): Land Size (acres): Land Size (SF): Sale History Jim 2, 2017 4012/0861 0001 WD Oldaker Rodger D $270,000 Jul 11, 2002 1557 / 1657 XX00 DE Newson Jr,Charles H $230,000 Sep 25, 2001 1446/1675 XX01 WD Newson Jr,Charles H $100 Dec 1, 1995., 0990/1143 XX00 WD $147,300 Building Information (1 of 1) Finished Area: 1,257 SF Gross Total Area: 1,481 SF Exterior Data Roof Cover: Roof Structure: Year Built: 1995 Frame: Effective Year. 1995 Primary Wall: CB Stucco No. Units: 1 Secondary Wall: Interior Data Electric: Primary lot Wall: Heat Type: Avg Hgt/Floor. 0 Heat Fuel: Primary Floors: Heated %: 0% Sprinkled %: o% Special Features and Yard Items Sum has By Ube: x851 = 125 XSM • 224 Current Year Values Current Values Breakdown Current Year Exemption Value Breakdown Building: $188,201( Land: so Just/Market: $188,200 Ag Credit: $0 Save Our Homes or 10% Cap: $0 Assessed: $188,200 Exemption(s): s0 Taxable: StSg,200 Historical Values Current Year Special Assessment Breakdown This does not necessarily represent the total Special Assessements that could be charged against this property The total amount charged for special assessments is reflected on the most current tax statement and information is available with the SLC Tax Collector's Office Q Permits Notice: This does not necessarily represent all the permits for this property. Click the following link to check for additional permit data in Saint Lucie County This information is believed to be correct at this time but it is subject to change and is not warranted ® Copyright 2017 Saint Lucie County Property Appraiser. All rights reserved. AHRI Certified Reference Number: 4084956 Date: 11/13/2017 tStatus: Active Product: Water/Brine to Air Heat Pump Packaged Unit Model Number: WSVX024*-6 Manufacturer: FIRST CO. Trade/Brand name: HYDROTECH Series Name: Rated as follows in accordance with ANSI/AHRI/ASHRAE/ISO Standard 13256-1 for Water -to -Air and Brine -To -Air Heat Pumps and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Air Flow Rate - Cooling: 745/745 Air Flow Rate - Heating: 745/745 WLHP (Water -Loop Heat Pumps) Full Load Cooling Capacity(Btuh) 23400 / 23400 Cooling EER Rating(Btuh/watt) 14.20 / 14.20 Cooling Fluid Flow Rate(gpm) 6.10/6.10 Heating Capacity(Btuh) 28000 / 28000 Heating COP(watt/watt) 4.30/4.30 Heating Fluid Flow Rate(gpm) 6.10/6.10 GWHP(Ground-Water Heat Pumps) Cooling Capacity(Btuh) 25500 / 25500 Cooling EER Rating(Btuh/watt) 19.80 /19.80 Cooling Fluid Flow Rate(gpm) 6.10/6.10 Heating Capacity(Btuh) 21300 / 21300 Heating COP(watt/watt) 3.70/3.70 Heating Fluid Flow Rate(gpm) 6.10 / 6.10 Indoor Blower Motor Fan Type: ECM Sold In: USA; FootNote 2 - Without domestic heat recovery unit operating. . Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's Individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahrldlrectory.org, click on "Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which is listed at bottom right. _--_-_____ _---- ©2014 Air -Conditioning, Heating, and Refrigeration Institute WSVX Series WATER SOURCE HEAT PUMP U Hy M R -410A V b u. B Ful ' rp1 ,, cVous ." PERFORMANCE DATA - AT STANDARD OPERATING CONDITIONS PERFORMANCE DATA - CERTIFIED AT ARUISO 13256-1 CONDITIONS ELECTRICAL DATA CFM GPM WATER LOOP (entering Water Temperature) 85 Deg.F 70 Deg.F COOLING EER HEATING COP MODEL NUMBER VOLTAGE COMPRESSOR RLA LRA BLOWER FLA HP MIN. CIRCUIT AMPACIY MAX. CIRCUIT PROTECTION WSVX018 2081230V-1-60 7.1 43 2.8 1/3 12 15 �,._.m....-.,...._.______ WSVX024'"--208/230V-1-60 8.1 43 -`-2:8"' 1/9 15 0 WSVX030 208/230V-1-60 10.6 54 4.1 1/2 18 25 WSVX036 20812WV-1-60 13.1 74 4.1 1/2 21 30 WSVX040 208/230V-1-60 15.7 88 1 4.1 1/2 27 40 WSVX042 2081230V-1-60 15.7 88 4.1 1/2 27 40 WSVX048 208/230V-1-60 20.2 117 7.6 1 33 50 WSVX060 208/230V-1-60 26.4 134 1 7.6 1 41 60 U Hy M R -410A V b u. B Ful ' rp1 ,, cVous ." PERFORMANCE DATA - AT STANDARD OPERATING CONDITIONS PERFORMANCE DATA - CERTIFIED AT ARUISO 13256-1 CONDITIONS MODEL CFM GPM WATER LOOP (entering Water Temperature) 85 Deg.F 70 Deg.F COOLING EER HEATING COP MODEL CFM GPM WATER LOOP (entering Water Temperature) 86 Deg.F 68 Deg.F COOLING EER HEATING COP WSVX018 550 5.0 17,110 14.1 21,210 4.30 WSVX018 550 5.0 17,ODO 14.0 21,000 4.30 WSVX024 745 6.1 23,620 14.4 28,260 4.30 WSVX024 745 6.7 23,400 14.2 28,000 4.30 WSVX030 930 9.0 28,250 14.2 33,120 4.40 WSVX030 930 9.0 28,000 14.0 32,800 4.30 WSVX036 950 1 10.0 33,350 14.1 42,510 4.40 1 WSVX036 950 1 10.0 33,000 14.0 42,100 4.30 WSVX040 970 10.1 37,320 13.2 46,620 4.30 WSVX040 970 70.1 36,900 13.0 46,100 4.30 WSVX042 7280 10.5 40,980 14.2 48,120 4.50 WSVX042 7280 70.5 40,500 14.0 47,500 4.40 WSVX048 1400 12.5 47,600 14.1 54,480 4.30 WSVX048 1400 12.5 47,100 14.0 53,800 4.30 WSVXO60 1760 15.5 56,590 14.42 70,000 4.30 WSVXO60 1760 75.5 56,000 74.0 69,300 4.30 Note: Tabulated performance data is at noted entering water temperature and entering air conditions of 80 degree DB / 67 degree WB for cooling and 70 degree DB for heating at 208V CFM. Note: Tabulated performance data is at noted entering water temperature and entering air conditions of 80.6 degree DB / 66.2 degree WB at ARI / ISO 13256-1 rated 208V CFM. All models factory wired for speed taps 1, 2 and 3- 110 Note: For superior dehumidification in the summer, all models operate at a slightly lower speed for a maximum of ten minutes before shifting to a higher speed. An optional "High" speed is available for higher static applications. BLOWER DATA FACTORY BLOWER SETTINGS MODEL NUMBER FAN SPEED MOTOR TERMINAL NO. CFM vs EXTERNAL STATIC PRESSURE (inches of water) 0.1 0.2 0.3 0.4 0.5 0.6 CLG 1-10MINS 10+MINS HTG HIGH STATIC 4 --- --- 720 690 640 580 WSVXO18 HIGH 3 620 590 540 500 460 --- X X LOW 2 540 490 450 390 360 --- X WSVX024 HIGH STATIC 4 --- --- 1000 930 850 750 HIGH 3 790 760 720 690 650 --- X X LOW 2 630 590 540 500 460 --- X HIGH STATIC 4 --- --- 1050 960 890 --- WSVX030 HIGH 3 970 950 920 890 850 --- X X LOW 2 820 780 750 720 690 --- X HIGH STATIC 4 --- --- 1040 970 910 --- WSVX036 HIGH 3 1050 1020 990 940 870 --- x x LOW 2 920 890 860 830 790 --- X WSVX040 HIGH STATIC 4 --- --- 1140 1110 1080 --- HIGH 3 1080 1050 1030 990 960 --- X X LOW 2 950 1 920 890 860 820 --- X HIGH STATIC 4 --- --- 1460 1430 1400 1340 WSVX042 HIGH 3 1370 1340 1310 1280 1250 --- X X LOW 2 1060 1030 1 1000 960 920 --- X HIGH STATIC 4 --- --- 1840 1820 1790 1740 WSVX048 HIGH 3 1530 1500 1470 1440 1410 --- X X LOW 2 1190 1160 1130 1100 1070 --- x HIGH STATIC 4 --- --- 1950 1920 1890 1840 WSVX060 HIGH 3 1880 1860 1840 1820 1790 --- X X LOW 2 1530 1500 7470 1440 1410 --- X All models factory wired for speed taps 1, 2 and 3- 110 Note: For superior dehumidification in the summer, all models operate at a slightly lower speed for a maximum of ten minutes before shifting to a higher speed. An optional "High" speed is available for higher static applications.