EVALUATION REPORT
GAF
1 -Campus Drive
Parsippany, N1 070S4
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE:.(203) 262-9245
FAX: (203) 262-9243
Evaluation Report 01506.01.08-1121
FL10124-1119
Date of Issuance: 01/03/2008
Revision 21:08/26/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the Sth Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may, be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
(NSPECTiON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert.I.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The faaimiie seal appearing was authorized by Robert Nieminen,
P.E. on 08/26/2016. This does not serve as an electronically signed
docum=nt. .Signed, sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION of INDEPENDENCE:
1. TrinitvlERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ER0 is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product. ,
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing,
Sub -Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
Conditions of Use set forth herein.
2: STANDARDS:
Section
Property
Standard
Year
1507.2.4, 8905.2.3
Physical Properties
ASTM D1970
2009
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2008
1507.2.7.5, 8905.2.6.1
Wind Resistance
TAS 107
1995
I REFERENCES:
Entity
Examination
Reference
Date
GAF (PDM 1915)
Letter of Equivalency
Seal -A -Ridge Impact Resistant IR
01/13/2012
PRI (TST 5878)
Physical Properties
GAF -025-02-01
03/27/2002
PRI (TST 5878)
ASTM D3462
GAF -059-02-01
09/02/2004
PRI (TST 5878)
ASTM D3462
GAF -080-.02-01
05/25/2005
PRI (TST 5878)
Physical Properties
GAF -324-02-01
12/01/2011
PRI (TST 5878)
Wind Driven Rain
GAF -407-02-01
01/21/2013
UL (TST 1740)
ASTM D3462
93NK6295
11/29/1993
UL (TST 1740)
ASTM D3462
99NK43835
01/12/2000
UL (TST 1740)
TAS 107
94NK9632
03/29/2000
UL (TST 1740)
ASTM D3462
01NK06632
02/02/2001
UL (TST 1740)
ASTM D3161, TAS 107
OINK9226
05/21/2001
UL (TST 1740)
ASTM D3161
OINK37122
12/18/2001
UL (TST 1740)
ASTM D3462
01NK37122
12/19/2001
UL (TST 1740)
ASTM D3161, TAS 107
02NK12980
04/10/2002
UL (TST 1740)
ASTM D3161, TAS 107
02 NK30871
09/09/2002
UL (TST 1740)
ASTM 03161
03CA5367
03/11/2003
UL (TST 1740)
ASTM D3462
03NK26444
10/17/2003
UL (TST 1740)
ASTM D3462
04NK13850
06/07/2004
UL (TST 1740)
ASTM D3161
04NK13850
06/23/2004
UL (TST 1740)
ASTM D3161
04NK30546
03/10/2005
UL (TST 1740)
ASTM D3462
04NK22009
05/06/2005
UL (TST 1740)
ASTM D3161
04NK22009
05/09/2005
UL (TST 1740)
ASTM D3462
OSNK27924
02/10/2006
UL (TST 1740)
ASTM D3161
05NK27924
02/11/2006
UL (TST 1740)
ASTM D3161, D3462
06CA18077
06/05/2006
UL (TST 1740)
ASTM D3161, D3462
OGCA18074
06/16/2006
UL (TST 1740)
ASTM D3161, D3462
06CA35251
10118/2006
UL(TST'1740)
ASTM D3462
06CA31603
12%01/2006
UL (TST 1740)
ASTM D3161, 03462
06CA41095
12/27/2006
UL (TST 1740)
ASTM D3161
07NK05228
03/13/2007
UL (TST 1740)
ASTM D3161
06CA31611
04/04/2007
UL (TST 1740)
ASTM D3161
06CA61148
04/09/2007
UL (TST 1740)
ASTM D3161, D3462
07CA31742
11/08/2007
UL (TST 1740)
ASTM D3161, D7158, D3462
OSCA06100
03/13/2008
UL (TST 1740)
ASTM D3161, D3462
07CASS908
04/01/2008
Exterior Research and Design, LLC. Evaluation Report 01506.01:.08-1121
Cerdficate of Authorization #9503 FL10124-1119
Revision 21: 08/26/2016
Page 2 of 6
Exterior Research and Design, LLC Evaluation Report 01506.01.08-1121
Certificate of Authorization #9503 FL10124-R19`
Revision 21: 08/26/2016'
Page 3 of 6'
TRIN11YIERD
Entity
Examination
Reference
Date
UL(TST.1740)
ASTM D3161;D3462
09CA10592
03/26/2009
UL (TST 1740)
ASTM D3161, D3462
09CA06856
05/15/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
09NK06647
08/01/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
09CA27281
08/27/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
IOCA35554
03/05/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
10CA13686
05/15/2010
UL (TST 1740)
ASTM D3462
IOCA07264
05/27/2010
UL(TST 1740)
ASTM D3462;
10CA11953
10/29/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
1ONK119S1
10/30/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
10NK12070
11/04/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
OBCA06100
01/30/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
10CA53934
03/31/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA48924
10/22/2011
UL (TST 1740)
ASTM D3161, D7158, D3462-
11CA47019
"12/03/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA48408
12/08/2011
UL (TST 1740)
ASTM D3161, D7158, D3462
11CA48725-
12/09/2011
UL, LLC. (TST 9628)
ASTM D3462
12CA34891
10/12/2012
UL, LLC. (TST 9628)
ASTM D3161, D7158, D3462
12CA58151
02/15/2013
UL, LLC: (TST 9628)
ASTM D3161
12CA38083
02/26/2013
UL, LLC. (TST 9628)
ASTM D3161
13.CA32332
06/18/2013
UL LLC, (TST 9628)
ASTM 03161
13CA37934
08/02/2013.
UL, LLC>(TST9628)
ASTM D3161, D7158, D3462
4786875675
07/17/2015
UL LLC. (TST 9628)
ASTM D3161, D7158, D3462
4787434542
05/17/2016
UL LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Mobile, AL
12/28/2015
UL, LLC, (QUA 9625)
Quality Control
Inspection Report, R21, Myerstown, PA
02/23/2016
UL LLC, (QUA 9625)
Quality Control
Inspection Report, R21, Tuscaloosa, AL
02/26/2016
UL, LLC. (QUA .9625)
Quality Control
Inspection Report, R21, Michigan Cty, IN
03/02/2016
UL LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Shafter, CA
02/18/2016
UL, LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Savannah, GA
02/24/2016
UL LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Minneapolis, MN
02/09/2016
UL, LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Mt. Vernon, IN
02/09/2016
UL, LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Baltimore, MD
03/61/2016
UL,LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Tampa, FL
02/29/2016
UL, LLC'. (QUA 9625)
Quality Control
Inspection Report, R21, Dallas, TX
02/17/2016
UL LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Ennis, TX
02/03/2016
UL, LLC. (QUA 9625.)
Quality Control
Inspection Report, R21, Fontana, CA
03/03/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMaxO, Royal Sovereign® and Sentinel" are a fiberglass reinforced
3-tab asphalt roof
shingles.
4.1.2; CamelotO, CamelotO 11, Fortitude'm, Glenwood'"', Grand Canyon, Grand Sequoia6, Grand
Sequoiao IR,
Grand SequoiaO
ArmorShieldT", MonacoO.,
Sienna°; Timberline' American Harvest®,
TimberlineO
ArmorShieid"' 11, Timberline° Natural Shadow®,
Timberline HDA', Timberline`s Cool SeriesO,
Timberline Ultra
HD® and Woodland® are fiberglass reinforced, laminated
asphalt roof shingles..
4.1.3 Slateline© is a fiberglass
reinforced 5-tab asphalt
roof shingle.
4.2 Hip & Ridge Shingles:
4.2,1 Seal-A-Ridges Ridge Cap Shingles, Seal-A-RidgeO IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShieid'°' Ridge
Cap Shingles and Timbertex"I
Premium. Ridge Cap Shingles are fiberglass
reinforced,hip
and ridge asphalt
roof shingles.
Exterior Research and Design, LLC Evaluation Report 01506.01.08-1121
Certificate of Authorization #9503 FL10124-R19`
Revision 21: 08/26/2016'
Page 3 of 6'
TRINI
IE .
4.3 Accessory Starter Strips:
4.3.1 Pro-Start0 Eave/Rake Starter Strip Shingles and WeatherBlockerl Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3:2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SB.S
modified bitumen starter strip, nominal 9 -inch x 33 ft roll, for use with asphalt shingles with exposure of 6 -
inch orless.
4.3.3 5tarterMatchT" Shatter Strip Shingles are color -coordinated starter strips for use with Grand CanyonO and
Grand Sequoia' series asphalt shingles. StarterMatch" are installed as the second starter for Grand
Canyon® and Grand Sequoia' series installations.
5. LIMITATIONS:
5.1 This is a building .code evaluation. Neither Trinity l ERD nor Robert Nieminen, P.E. are; in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation: Reportisnot for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 TheGAFasphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to V,,,d = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
.5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and 119.05.2.6.1, to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to
Vasa:=150 mph (Vu,t=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B. or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment;
6:1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1S07.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBiocker Premium Eave/Ra.k.e Starter Istrip
Shingles and.QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) ..nails per shingle in accordance with FBC Sections. 1507.2 or .8905.2, with the following
;exceptions:
Camelot; Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia lk, Grand Sequoia ArmorShieldi and
Woodland require minimum five (5) nails per shingle.
Y Slateiine requires minimum 8ix.(6) nails per shingle.
Exterior Research and Design; LLC, Evaluation Report 01506.01.08-1121
Certffcute of Authanzation #9503 FL10124-R19
Revision 21: 08/26/2016
Page 4 of 6'
TR NITY E .D.
6.3.2., ,Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507;2.6
or.R905.2.5.,Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units"horizontal, special methods of.fastening'.are
required. Contact the shingle manufacturer for details.
6.4. Hip&Ridge Shingles:
6.4.1 Installation,&Seal-A-Ridge Ridge.Cap Shingles,Seal-A-Ridge iR Impact-Resistant Ridge Cap=5hingles and'Seal-
A-Ridge ArmorShield Ridge Cap.Shingles shall comply with the manufacturer's current published instructions
with a minimum two(2)nails,minimum 3/8-inch head diameter,per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30.Roof&.Flashing Sealant".
715'
mnSealant
a}' t
(25 mm). (25 min} Sca lAnte
Endti t d6tmchsite
{ 1.2'
I ^R ;305 mm}
Nast:
Clava
6S,8'-7518" 'Clover
:(768-194 mm)
12" _
{3t38.rriln}'
6.4:2 : Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current
published instructions with, a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and
beads of Sonneborn NP1 Gun Grade.Polyurethane Sealant or Henkel.PL.Roofing and Flashing.Sealant:
its,
( rnir} 7 t"Sttantr
iras twhi, 125 rssrh . Krsitrz ct"$tar. t i
?31ik7j
i
1
is '.i'
6.4.3 Fasteners shall be in accordance with the manufacturer's;published requirements, but'not less than'FBC
1507.2.6 orR905.2.5. Staples Are not permitted.
Exterior Research and Design;LLC. Evaluation Report 01506.01.08-RZ1:
? certificate ofAuthorization#9503 FL10124-R19
Revision 21:08/26/2016
Page 5 of 6
TRINITYERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce: products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC — QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1121
Certificate of Authorization #9503 FL10124-1119
Revision 21: 08/26/2016
Page 6 of 6
TRINII 11, ERD
EVALUATION REPORT
Allied Building Products Corp.
dba TRI -BUILT Roofing Products
9050 Louisiana Street
Merrillville, IN 4:6410
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report A42960.10.12 -R4
FL16048-R4
Date of Issuance: l0/25/2012
Revision 4: 10/06/2016
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P:E.. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume, The.
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI -BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein,
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this. Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, R.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity l ERD requires a complete review of this.
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seat appearing was authorized by Robert Niemirien,
P.E. on 1010o/2016. This does not serve a> an electronically signed
document. Signed, sealed hardmples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing, products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nierninen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval. process of the
product. 1
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
n
TRINITY ERD
I
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement., TRI -BUILT Roof Underlayments, as produced by TRI -BUILT, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, 1507.2.8, 1507.2.9:2,
Physical Properties
ASTM D1970
2009
1507.4.5.1, 1507.53, 1507.7.3
Physical Properties
S40540.11.13
11/19/2013
1504.6
Accelerated Weathering
ASTM G155
2005
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
1523.6.5:2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049i
Physical Properties
S40540.02.13-1
02/19/2013
ERb (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
540540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
544870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
544870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
544870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
543530.02.14-1-R1
05/14/2014
ERD (TST6049)
Physical Properties
543530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SC8520.04.15
05/27/2015
UL, LLC. (.QUA9625)
Quality Control
Multiple -Listing 816814
09/04/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlayments:
4.1.1 Tri -Built Sand -R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36 -inch sheet width.
4.1.2 Tri -Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri -Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained -specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C.
Certtftcate ofAothorization #9503 FBC NON-HVHZ EVALUATION
Evaluation Report A42960.10.12 -R4
FL16046-R4
Revision 4-.10/06/2016
Page 2 of 5
ERD
5.4 TRI -BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1:, ROOM COVER OPTIONS
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
& Shingles.
Tri -Built Sand -R SA Shingle
Yes
No
No
No
Yes
Yes
Underlayment
Tri -Built S/A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
Tri -Built Smooth HT S/A
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion /.long
term aging data from an accredited testing laboratory is provided.
Tri -Built S/A HT TU Underlayment with 3M"' 2 -Component Roof Tile Adhesive AH -160 (FL6332) or
Dow TileBondTM Roof Tile Adhesive (FL717)
&6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck:
Tri -Built Sand -IR SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A
Underlayment applied to:
Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI -BUILT recommends
priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI -BUILT
requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underiayment.
5.6.2 BonclAo-Insulation:
Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A
Underlayment applied to:
Y Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri -Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
Tri -Built Sand -R SA Shingle Underlayment; Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached ;per
minimum codified requirements. For installations under foam -on the systems (Tri -Built S/A HTi TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
Exterior Research and Design, LLC Evaluation Report A42960.10.12-114
Certificate ojAutharization #9503 FBC NON-HVHZ EVALUATION FL16048-R4
Revision 4;10/06/2016
Page 3 of 5
TRIERCP
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck.
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressure's.
5.6.4.1 Maximum Design Pressure = -45.0 psf.
Deck:
Min. 15/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Primer:
(Optional)'ASTM D41
Underlayment:
Tri -Built SIA HT TU Underlayment, self -adhered.
5.6.4.2 Maximum Design Pressure = -67.5 psf.
Deck:
Structural concrete to meet project requirements to satisfaction of AHJ.
Primer:
Soprema Elastocol 600c
Underlayment:
Tri -Built S/A HT TU Underlayment, self -adhered.
5.6.4:3 Maximum Design Pressure = -60.0 osf.
Deck: Min. 19/32 -inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6 -inch o.c. at the 4 -inch laps and 6 -inch o.c, in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri -Built S/A HT TU Underlayment, self -adhered.
5.7 Exposure Limitations:
5.7.1 Tri -Built Sand -R SA Shingle Underlayment or Tri -Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30 -days after installation
5.7.2 Tri -Built S/A HT TU Underlayment shall not be left exposed for longer than 180 -days after installation.
6. INSTALLATION:
6.1 TRI -BUILT Roof Underlayments shall be installed in accordance with TRI -BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri -Built Sand -R SA Shingle Underlayment, Tri -Built S/A HT TU Underlayment or Tri -Built Smooth HT S/'A.
Underlayment
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2. Non -Tile applications:
While priming is optional, TRI -BUILT recommends priming the deck if the final roof cover is not slated :for
installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film .diagonally while holding the
membrane tight. Firmly roil; broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3 -inches, configured to shed water. Vertical seams should be 6
inches and staggered not less than 2 -ft from vertical seams in the course below, sealed in accordance with
TRI -BUILT requirements.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12 -R4
Certificate ofAuthorization #9503 FBC NON-HVHZ EVALUATION FL16048-R4
Revision 4: 10/06/2016
Page 4 of 5
ERE
When installing at slopes above 8:12, TRI-BUILT recommends back-nailing in the overlap area at the top', of
the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge'in.
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built SIA HT TU Underiayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on the applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSAjTRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
S. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ulLcom
- END OF EVALUATION REPORT -
Exterior Research' and Design, LLC
Certificate ofAutharization #9503 FBC NON-HVHZ EVALUATION
Evaluation Repod A42960.10.12 -R4
FL16048=R4.
Revision 4:10/06/2016
Page 5 of 5