Loading...
HomeMy WebLinkAboutBuilding Permit Application (3) 11/18/2017 ( 0-� 1� Florida Building Code Online Business m ut - • Professional SCIS Home Log In , User Registration ' Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search dbpr a )Product Approval /� �,y USER:Public User 11�n� k T Product Aooroval Menu>Product or Aoolication Search>Aoolication List>Application De 10 FL# FL10674-R12 Application Type Revision BY:. ....................... Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com-'' Authorized Signature Greg Keeler C greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R12 COI 2016 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By https:/twww.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEA65bxB8ctyag%3d%3d 1/2 11/18/2017 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 Date Revised 10/10/2017 Summary of Products FL# Model, Number or Name rDescription 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab, 5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R12 II 2016 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674 R12.Ddf Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to ER,Section 5. Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-R12.Ddf Created by Independent Third Party: Yes Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ® ® ® Credit Card Safe https://www.floddabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5V°/p2boQTg/g2b6w7ahReglCQ8ucR6ixEA65bxB8ctyag%3d%3d 2/2 EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization 119503 TRINITY ERD 353 CHRISTIAOXFORD,TN STREET, NIT#13 6478 PHONE: (203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R7 One Owens Corning Parkway FL10674-1112 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ,sT0tttfrrr„q • t4,: Robert J.M.Nieminen,P.E. 'w. I The fauimileseal appearing was authorized byRobert Nieminen, ° 4�a�.��t.`}, P.E.on 04/18/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 up.r"r"' document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire'""are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition� Durationo, Durations Premium Cool, TruDefinitione Duration Designer Color Collection, TruDefinition*Oakridge, Oakridge and WeatherGuard* HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard� HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'"Hip&Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 F1.10674-1112 Revision 7:04/18/2016 Page 2 of 8 TRINITY ERS 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle, 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 611320-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire'shingles require minimum five(5)nails per shingle. ➢ WeatherGuard*HP shingles require minimum six(6)nails per shingle. ➢ Devonshirelm shingles require minimum six(6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Fekunderhymem -Deck Self-eA0red _ Weatwdockf L, Self-adhered underlay— WeatherLocke =i _ underlayment k Drip Drip edge Drip___, Drip edge edge edge j' Nails located Nailocated - from eave 2"-3"from eave Install first Self-sealing adhesivefirst Sdkeaing WMsive Starterstnp .•• positioned along eave wiInsta6"mm ved StnpPfiet-__4- .'� positioned along eave shingle with \ with 8 removed-- \ 6"removed Starter Strip shingle overhangs eaves and rakes',"-'," Starve Strip Pias overhangs eaves and rakes tu'-3/4" Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 3 of 8 TRINITY ERD 6.2.6 Minimum Nailing—Classics&Supreme: Normal Mansard or Area porn Normal Mansard or Area para Wind Areas High Wind doevanes y Wind Areas High Wind deavanes y Area para viontos normalea Areas vientos haartes Area pan vlsntos normsles Areas Wanton fuer -s �• IAI t i z• IB z' t. t.. (� t. t" Z. IB 2. t. �r tz lit 3"Exposure 5 518"Exposure Exposicidn Exposici6n 6.2.7 Minimum Nailing—Berkshires: Seaters strip Sealant snip La tka de seRaM La tira de sellador J7 • • • yi ybr A' 8,.. 8'a' B x' 812" 1 r r Standard Fastening Pattern 6-Nail Fastening Pattern Sealantstrip La tira de sellad& •� �•o- - • -----------•�--i• a 2" Asphah rwling cement Cemento de Who de astalto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-117 Certificate ofAuthorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 4 of 8 TRINITY ERS 6.2.8 Minimum Nailing—Devonshire'': N Gryw Nails I 5-5/8"exposure Sealant location Exposici6n de 5.5/8 pulg Ubieacidn del sellador Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Duration®, TruDefinition® Duration, Duration® Premium Cool &TruDefinition� Duration Designer Color Collection: 4-Nail Fastening Pattern 6-Nall Fastening Pattern AnNOW tawWonya waR SureNeW taf4nwq ano wMh Na ryper No Typkw 1" 12" 12" e-»ce.+v..rer •. �.."o o... ..«. ..«�:c.�w�-- • �w«»b __.c:�e c==o w.n,a • F� FL s-w a•an- � FI I Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 .wr.NM.r.."Ing u.a kith ('N.N.Typist Ir lour+"1poU or A.pinit Ro&"C-t Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 5 of 8 TRINITY ERS 6.2.1 Minimum Nailing—TruDefinition*Oakridge®,Oakridge®: 4 Nail Pattern 6 Nail Pattern Esquema con 4 clavus Esquama con 6 clavus V f1 r r I.(-- rr --f•I Imo— 12- �E— tz• �•� N— 12" 5 5f8"Exposure Nails 5 5/8"Exposure Nails Exposld6rrdo55/8p+dg. ciavos Exposicidndo65/9pufg. 55/8"ExpostiR clavos 5SN'ExposuRa Exposid6n de 6 5/8 putg. Exposic'dbn fie 5 6/8 pidg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 suwrlN rnbmq mR+Me� /r NMI,T W- 1— 4+T s.yg^ Four+"epob of A"*"Roofing Cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: IlMolle 11NrallAow .v:: :•:�• fliMwwrll�wf�LYI 1ii� fJw�w rift.i� Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-117 Certificate of Authorization 119503 FL10674-R12 Revision 7:04/18/2016 Page 6 of 8 TRINITY ERS 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire* Hip and Ridge Shingles, High Ridge, WeatherGuarde HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1 4 Fig.2 �— PMOINYladC DYeabn p Topwew Sidewew "ails— A Naps Nails 4 Top Laninaed r t A j 1 a' Pie[e17 4 I I I I I I I I A 1 I 1 I I I I I I I p I I 1 I 41 p r �6poa1�r ul I i I i I 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 9 4 pnawpFlp wYp TopVbw �—pnigbn p A Nolle A i i NeIN NpIY 4" I I I I l�- —►I s' Eqmap Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7:04/18/2016 Page 7 of 8 TRINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind DirectionFastening Seebnt Snip Pattern 6'Exposure %" Y-� �' '�•� I•Y 12'jh'� Fasten 7'h' 78'Expel inCover Expewd Fasteners wrth Roof Cement 6.3.6 Minimum Nailing—DuraRidge'" Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. r—Prevailingwnd Direction vase en plan Direction dtaninante di writ r+l vnca superior I'IN Direction del ritnto prodtxninnnte t uou Ver Haile . 2 a Owern caning SurcNalr e c 11p ----_.. __ t1aret�� `S � ) I I I• I I ' I I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (414)248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 F1.10674-1112 Revision 7-.04/18/2016 Page 8 of 8