HomeMy WebLinkAboutProduct Approval MIAMI• MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
1-(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE NOA www.miamidade.eov/economy
Sun-Tek Manufacturing,Inc.
10303 General Drive
Orlando,FL 32824
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control
Section (hi Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the High Velocity
Hurricane Zone of the Florida Building Code.
DESCRIPTION:Hurricane Self Flashing(HSF)Aluminum Skylight
APPROVAL DOCUMENT:Drawing No. HSF-002,titled"HSF", sheets 1 and 2 of 2,dated 01/27/2001,
with revision dated 05/04/2015,prepared by Sun-Tek Manufacturing,Inc.,signed and sealed by James D.
Wells,Jr.,P.E., bearing the Miami-Dade County Product Control revision stamp with the Notice of
Acceptance number and the expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state,
model/series and following statement; "Miami-Dade County Product Control Approved",unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises&renews NOA# 12-0424.05 and consists of this page 1 and evidence submitted
pages E-1 &E-2 as well as approval document mentioned above.
The submitted documentation was reviewed by H�Imy A.Makar,P.E.,M.S.
CJINOA No. 15-0513.07
MIAMI•DADECOUNTY //&,� Expiration Date:01/10/2021
r(/O 5-1Z_6/S Approval Date: 11/05/2015
Page 1
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No.HSF-002,titled"HSF",sheets 1 and 2 of 2, dated 01/27/2001,with revision
dated 12/15/2010,prepared by Sun-Tek Manufacturing,Inc.,signed and sealed by James D.
Wells,Jr.,P.E.
B. TESTS "Submitted under NOA #11-0104-09"
1. Test reports on 1)Air Infiltration Test,per FBC,TAS 202-94
2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3)Water Resistance Test,per FBC,TAS 202-94
4)Large Missile Impact Test per FBC,TAS 201-94
5)Cyclic Wind Pressure Loading per FBC,TAS 203-94
6)Forced Entry Test,per FBC 2411 3.2.1,TAS 202-94
along with marked-up drawings and installation diagram of HSF Polycarbonate Aluminum
Fixed Skylights,prepared by National Certified Testing Laboratories,Test Reports No.210-
3716-1, dated 11/22/2010,with a revision dated 03/07/2010,signed and sealed by Gerard J.
Ferrara,P.E.
C. CALCULATIONS "Submitted under NOA #11-0104-09"
1. Anchor calculations prepared by J&L Wells Consulting LLC, dated 01/04/2011, signed and
sealed by James D. Wells,Jr.,P.E.
D. QUALITY ASSURANCE
1. Miami-Dade Department of Permitting,Environment,and Regulatory Affairs(PERA)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 12-0110.04 issued to Palram Americas,Inc. for their"Corrugated
and Flat Polycarbonate Panels",approved on 02/23/2012 and expiring on 01/22/2016.
2. Notice of Acceptance No. 08-0305.02 issued to SABIC Innovative Plastics for their"Lexan
Sheet Products"approved on 04/24/2008 and expiring on 07/17/2013.
3. Notice of Acceptance No. 10-0329.03 issued to Sheffield Plastics,Inc., for their"Makrolon
Polycarbonate Sheets"approved on 07/07/2010 and expiring on 08/27/2012.
F. STATEMENTS
1. Statement letter of code conformance to 2010 FBC issued by J&L Wells Consulting LLC,
dated 04/25/2012,signed and sealed by James D.Wells,Jr.,P.E.
"Submitted under NOA #11-0104-09"
2. Statement letter of code conformance with FBC 2007 and no financial interest issued by J&L
Wells Consulting LLC,dated 03/17/2011,signed and sealed by James D.Wells,Jr., P.E.
_1� 0�9 WzLi�_l
y A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 15-0513.07
Expiration Date: 01/10/2021
Approval Date: 11/05/2015
E-1
Sun-Tek Manufacturina, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. HSF-002, titled "HSF", sheets I and 2 of 2, dated 01/27/2001, with
revision dated 05/09/2015,prepared by Sun-Tek Manufacturing, Inc., signed and
sealed by James D. Wells, Jr., P.E.
B. TESTS
1. None,
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County, Regulatory and Economic Resources Department (RER).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to 2014 FBC issued by J&L Wells Consulting LLC,
dated 0510512015, signed and sealed by James D. Wells, Jr., P.E.
Lf-Driny A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 15-0513.07
Expiration Date: 01/10/2021
Approval Date: 11/05/2015
E-2
PART NAME: PLAN VIEW HSF ISHEET 2 OF
DRAWN BY: L. B.REED DWG./k:HSF 002
-- 54.50 NOTE:
4.00 (1)ALL ROOF DETAILS SHALL COMPLY WITH
6.75
CHAPTER 15 OF THE 2014 FLORIDA BUILDING
675 0 0 (2)4O MINIMUM DISTANCE FROM ANGLE LIP TO 4LI MIM.
6,00 6.75 0.63 ►{ Tq ROOF SURFACE FOR SHINGLES OR B.U.R. ROOF
WITHOUT INSULATION. FOR INSULATION SURFACE
AND TILE ROOF ADD TILE HEIGHT AND
INSULATION THICKNESS TO THE 4"MINIMUM
N HEIGHT.
o
`r N POLYCARBONATE DOME.093 THICK
32 FASTENERS FRAME TO DECK (Palram Palsun,Sheffield Makrolon or Sabic Lexan 9034))
to
N_
c) � + HSF 4646 co POLYCARBONATE DOME.080 THICK
L g — (Palram Palsun,Sheffield Makrolon or Sabic Lexan 9034)
(6 SYME ERICAL 'n
Ij J&L WELLS CONSU MNO LIC _
E eer ofRwm&-
lOviedo.FL 2765 James D.Wella,Jr.,P.E.
(407)49fi-5489 Professional Enghmw No.53616
Calif eift of Auftcludon No.27162
32 FASTENERS DECO RING TO FRANE
DESIGN PRESSURE RATING
+- 60 PSF PRODUCTMVISED
LARGE MISSLE IMPACT RESISTANCEB,„` glainC ""°F'"'aa
Accaodo
ptanw No —05-/3.0 7
84*Vtion Dab u
� rodtM Control
FASTENER SCHEDULE FRAME TO DECK FASTENER SCHEDULE DECO RING TO FRAME
_
#811X 1 PHILLIPS PAN HEAD SCREWS #6 X 3/4 HEX HEAD SELF DRILLING SCREWSauuu,ff�v
MODEL PER LONG SIDE PER SHORT SIDE MODEL PER LONG SIDE PER SHORT SIDE `����` �epi��s ���
4646 8 8 _ 4646 8 8
3046 8 6 3046 8 6 = No•53B1B
3636 7 7 3636 7 7 �I `
2246 8 5 2246 8 5
22225 5 2222 5 5
--- ---
REVISION:
REVISION: REWSION: PRODUCT NAME: SUN-TEK
10303 GENERAL DRIVE
WI: INI: HSF INDUSTRIES, INC. ORLANDO,FL 32824
4DATE.:01/28/01 1 SCALE: I DWG No. HSF-002
PART NAME: PRODUCT DRAWING SHEET OF
DRAWN BY: L.B.REED DWG.#:HSF-002
OUTER DOME.093 POLYCARBONATE SILCONE DOME SEAL
(Palram Palsun, Sabic Lexan 9034 or SHeffield Makrolon) (CONTINOUS)
DECO CLIP.060
6063 T-6 ALUMNIUM #6 X 3/4"HEX HEAD
STI-217 INSULATED AIR SPACE SELF-DRILLING
8 PER SIDE
fDECO RING.050
6063 T-5
ALUMNIUM STI-208
BUTYL SEALING TAPE INNER DOME.080
(CONTINOUS) POLYCARBONATE(Palram Palsun, FRAME .080
Sabic Lexan 9034 or Sheffield Makrolon)) 6063 T-6 ALUMNIUM
STI-207 U zizi
CORNERS MITERED O
INSULATION OR AND WELDED � W
DESIGN PRESSURE RATING o 0
+-60 PSF AIR SPACE � u-
LARGE MISSLE IMPACT RESISTANCE PVC LINER Enghuw of Rcoor&
STI-300 James D.Wells,Jr.,P.S. Z
STS 1000 SEALANT COMPLY WITH SECTION 2612 ProfessionalEnginarNo.53616
CONTINOUS UNDER FRAME v 0
AROUND PERIMETER OF THE F.B.C.
OVER HEADS OF SCREWS
Jeal..WELLS CONSMTJNG LLC
NOTE: 1453 Arbku Circle
(1)ALL ROOF DETAILS SHALL COMPLY WITH Oviedo,FL 32765
-5489
CHAPTER 15 OF THE 2014 FLORIDA BUILDING Ce 496ofAul
Cerdtiaro of Authoe6oWoo No.17lY
CODE.
(2)4"MINIMUM DISTANCE FROM ANGLE LIP TO
ROOF SURFACE FOR SHINGLES OR B.U.R.
WITHOUT INSULATION. FOR INSULATION
AND TILE ROOF ADD TILE HEIGHT AND
0.26' INSULATION THICK,�l1�7Ff,J,�T HE 4"MINIMUM °�
HEIGHT. ���� �°'0 —� �G PRODUCT RCVISGo
✓'P%� ##8 X 1"PHILLIPS PAN HEAD ra•,,,Plrr'8withlMFlmid-
0""0 c7
MINI.1/4"PROTRUSION ROOF DECK MIN .��,* ''—„ 8 PER SIDE oUaa S-os Jo 2!
THROUGH ROOF DECK o.53616
"THICKNESS A of D Icao
REVISION: ION: PRODUCT NAME. HSF �� ORlO ��`'
411-NA4i't"I SUN-TEK MANUFACTURING, INC.
INI: - 10303 GENERAL DRIVE ORLANDO,FL 32624
Ti�.15.10 DATE:011071011 SCALE: DWG No. F-002