HomeMy WebLinkAboutProduct Approval MIAMI• MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 1-(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE NOA www.miamidade.eov/economy Sun-Tek Manufacturing,Inc. 10303 General Drive Orlando,FL 32824 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (hi Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:Hurricane Self Flashing(HSF)Aluminum Skylight APPROVAL DOCUMENT:Drawing No. HSF-002,titled"HSF", sheets 1 and 2 of 2,dated 01/27/2001, with revision dated 05/04/2015,prepared by Sun-Tek Manufacturing,Inc.,signed and sealed by James D. Wells,Jr.,P.E., bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state, model/series and following statement; "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises&renews NOA# 12-0424.05 and consists of this page 1 and evidence submitted pages E-1 &E-2 as well as approval document mentioned above. The submitted documentation was reviewed by H�Imy A.Makar,P.E.,M.S. CJINOA No. 15-0513.07 MIAMI•DADECOUNTY //&,� Expiration Date:01/10/2021 r(/O 5-1Z_6/S Approval Date: 11/05/2015 Page 1 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No.HSF-002,titled"HSF",sheets 1 and 2 of 2, dated 01/27/2001,with revision dated 12/15/2010,prepared by Sun-Tek Manufacturing,Inc.,signed and sealed by James D. Wells,Jr.,P.E. B. TESTS "Submitted under NOA #11-0104-09" 1. Test reports on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5)Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411 3.2.1,TAS 202-94 along with marked-up drawings and installation diagram of HSF Polycarbonate Aluminum Fixed Skylights,prepared by National Certified Testing Laboratories,Test Reports No.210- 3716-1, dated 11/22/2010,with a revision dated 03/07/2010,signed and sealed by Gerard J. Ferrara,P.E. C. CALCULATIONS "Submitted under NOA #11-0104-09" 1. Anchor calculations prepared by J&L Wells Consulting LLC, dated 01/04/2011, signed and sealed by James D. Wells,Jr.,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Permitting,Environment,and Regulatory Affairs(PERA) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 12-0110.04 issued to Palram Americas,Inc. for their"Corrugated and Flat Polycarbonate Panels",approved on 02/23/2012 and expiring on 01/22/2016. 2. Notice of Acceptance No. 08-0305.02 issued to SABIC Innovative Plastics for their"Lexan Sheet Products"approved on 04/24/2008 and expiring on 07/17/2013. 3. Notice of Acceptance No. 10-0329.03 issued to Sheffield Plastics,Inc., for their"Makrolon Polycarbonate Sheets"approved on 07/07/2010 and expiring on 08/27/2012. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC issued by J&L Wells Consulting LLC, dated 04/25/2012,signed and sealed by James D.Wells,Jr.,P.E. "Submitted under NOA #11-0104-09" 2. Statement letter of code conformance with FBC 2007 and no financial interest issued by J&L Wells Consulting LLC,dated 03/17/2011,signed and sealed by James D.Wells,Jr., P.E. _1� 0�9 WzLi�_l y A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 15-0513.07 Expiration Date: 01/10/2021 Approval Date: 11/05/2015 E-1 Sun-Tek Manufacturina, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. HSF-002, titled "HSF", sheets I and 2 of 2, dated 01/27/2001, with revision dated 05/09/2015,prepared by Sun-Tek Manufacturing, Inc., signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. None, C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County, Regulatory and Economic Resources Department (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to 2014 FBC issued by J&L Wells Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E. Lf-Driny A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 15-0513.07 Expiration Date: 01/10/2021 Approval Date: 11/05/2015 E-2 PART NAME: PLAN VIEW HSF ISHEET 2 OF DRAWN BY: L. B.REED DWG./k:HSF 002 -- 54.50 NOTE: 4.00 (1)ALL ROOF DETAILS SHALL COMPLY WITH 6.75 CHAPTER 15 OF THE 2014 FLORIDA BUILDING 675 0 0 (2)4O MINIMUM DISTANCE FROM ANGLE LIP TO 4LI MIM. 6,00 6.75 0.63 ►{ Tq ROOF SURFACE FOR SHINGLES OR B.U.R. ROOF WITHOUT INSULATION. FOR INSULATION SURFACE AND TILE ROOF ADD TILE HEIGHT AND INSULATION THICKNESS TO THE 4"MINIMUM N HEIGHT. o `r N POLYCARBONATE DOME.093 THICK 32 FASTENERS FRAME TO DECK (Palram Palsun,Sheffield Makrolon or Sabic Lexan 9034)) to N_ c) � + HSF 4646 co POLYCARBONATE DOME.080 THICK L g — (Palram Palsun,Sheffield Makrolon or Sabic Lexan 9034) (6 SYME ERICAL 'n Ij J&L WELLS CONSU MNO LIC _ E eer ofRwm&- lOviedo.FL 2765 James D.Wella,Jr.,P.E. (407)49fi-5489 Professional Enghmw No.53616 Calif eift of Auftcludon No.27162 32 FASTENERS DECO RING TO FRANE DESIGN PRESSURE RATING +- 60 PSF PRODUCTMVISED LARGE MISSLE IMPACT RESISTANCEB,„` glainC ""°F'"'aa Accaodo ptanw No —05-/3.0 7 84*Vtion Dab u � rodtM Control FASTENER SCHEDULE FRAME TO DECK FASTENER SCHEDULE DECO RING TO FRAME _ #811X 1 PHILLIPS PAN HEAD SCREWS #6 X 3/4 HEX HEAD SELF DRILLING SCREWSauuu,ff�v MODEL PER LONG SIDE PER SHORT SIDE MODEL PER LONG SIDE PER SHORT SIDE `����` �epi��s ��� 4646 8 8 _ 4646 8 8 3046 8 6 3046 8 6 = No•53B1B 3636 7 7 3636 7 7 �I ` 2246 8 5 2246 8 5 22225 5 2222 5 5 --- --- REVISION: REVISION: REWSION: PRODUCT NAME: SUN-TEK 10303 GENERAL DRIVE WI: INI: HSF INDUSTRIES, INC. ORLANDO,FL 32824 4DATE.:01/28/01 1 SCALE: I DWG No. HSF-002 PART NAME: PRODUCT DRAWING SHEET OF DRAWN BY: L.B.REED DWG.#:HSF-002 OUTER DOME.093 POLYCARBONATE SILCONE DOME SEAL (Palram Palsun, Sabic Lexan 9034 or SHeffield Makrolon) (CONTINOUS) DECO CLIP.060 6063 T-6 ALUMNIUM #6 X 3/4"HEX HEAD STI-217 INSULATED AIR SPACE SELF-DRILLING 8 PER SIDE fDECO RING.050 6063 T-5 ALUMNIUM STI-208 BUTYL SEALING TAPE INNER DOME.080 (CONTINOUS) POLYCARBONATE(Palram Palsun, FRAME .080 Sabic Lexan 9034 or Sheffield Makrolon)) 6063 T-6 ALUMNIUM STI-207 U zizi CORNERS MITERED O INSULATION OR AND WELDED � W DESIGN PRESSURE RATING o 0 +-60 PSF AIR SPACE � u- LARGE MISSLE IMPACT RESISTANCE PVC LINER Enghuw of Rcoor& STI-300 James D.Wells,Jr.,P.S. Z STS 1000 SEALANT COMPLY WITH SECTION 2612 ProfessionalEnginarNo.53616 CONTINOUS UNDER FRAME v 0 AROUND PERIMETER OF THE F.B.C. OVER HEADS OF SCREWS Jeal..WELLS CONSMTJNG LLC NOTE: 1453 Arbku Circle (1)ALL ROOF DETAILS SHALL COMPLY WITH Oviedo,FL 32765 -5489 CHAPTER 15 OF THE 2014 FLORIDA BUILDING Ce 496ofAul Cerdtiaro of Authoe6oWoo No.17lY CODE. (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFACE FOR SHINGLES OR B.U.R. WITHOUT INSULATION. FOR INSULATION AND TILE ROOF ADD TILE HEIGHT AND 0.26' INSULATION THICK,�l1�7Ff,J,�T HE 4"MINIMUM °� HEIGHT. ���� �°'0 —� �G PRODUCT RCVISGo ✓'P%� ##8 X 1"PHILLIPS PAN HEAD ra•,,,Plrr'8withlMFlmid- 0""0 c7 MINI.1/4"PROTRUSION ROOF DECK MIN .��,* ''—„ 8 PER SIDE oUaa S-os Jo 2! THROUGH ROOF DECK o.53616 "THICKNESS A of D Icao REVISION: ION: PRODUCT NAME. HSF �� ORlO ��`' 411-NA4i't"I SUN-TEK MANUFACTURING, INC. INI: - 10303 GENERAL DRIVE ORLANDO,FL 32624 Ti�.15.10 DATE:011071011 SCALE: DWG No. F-002