Loading...
HomeMy WebLinkAboutProduct Approval Business & Professional #.. . o. * Regulation Pdw��f�illiiiil� I l i 1111411,�t'1!'�Il�'U;l191li!E4y ... _ SCIS Mbme. q In I User Repfstratibn Hn1 Tppis Submit SGrchar4e Statg&Facts Publications t BC Staff BUS 5(te Mep L1nks Search . -0 Product Approval USER:Puhlk',User ProductAonroval Menu>Pmduct-or.Appliccation search>.Application Wt>rApplleatlon befall FL# FL10674-1112 - Application Type Reyision Code Version 20114 Application Status Approved *Approved by DBPR.Approvals:by 0 PR shall be.reviewed and ratifed'by the-POC and/or'the Commission If necessary. Comments- Archived d Product Manufacturer Owens Corning. Address/Phone/Email One Owens Corning Parkway Toledo,.OH 43659:' (740)464-7829 greglkeele"r�howenscorntng.com- Authorized.Signature, Greg Keeler greg.keeler@ wenscorning;com Technical.Representative Met Sancrant Address/PhoreVEmaii 1 Owens Coming PKWY Toledo,OH 43659. (419):376-8360 Ines sancrant@owenscornig.com, Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt-Shingles ;Compliance Method Evaluation Report from.a Florida:Registered Arch tect.;or a Licensed Florida. Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or.Arch(tect Name;who.deveioped the Robert I.M.,Nieminen Evaluation Repot. Florida License PE-59166 Quality Assurance Entity UL'LCC .Quality Assurance Contract Expiration Date OS/16/2020 Validated.ey John W..,Knezevch,:PE Validation Checklist Hardcopy.Received Certificate of Independence FL10674 R12 COI. 2016 01 COI; Nieminen:pdf Referenced Standard and Year(of.standard) 15tandard Year; ASTM D3161 2009 ASTM D3462- 2009 ASTM D7158 2008 E4uivalence of Product Standards Certified By Sections from.the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date PendingFBC Approval 04/20%2016 Date Approved 06/08/2016 Date Revised; 10/10/20.17 Summa " of Products_ 'FL,.# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 34,66,4-tab,5-tab,taminat4d,starter and hip.&ridge shingles Shingles and.Starters Limits of Use: INstaliatioin Instruefans Approved for use in 14VH2:'No FLT0674 R12 II 2416 04 FINAL ER "f3C ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-g12.Ddf Impact Resistant:N/A, Verified B.y Roberta.:M. Nieminen RE-59166 Design'Pressurei N/A Created by Independent Third,Party:Yes Other:Refer to:ER;Section.5 Evaluation.Reports FL10674' R12 AE 2816 04.•FINAL ER OC. ASPHALT SHINGLES fumm-R1Z.odr' Created by`.Independent Third Party':Yes Back Next. Contact Us:-.2601 Blair Stone Road,Tallahassee FC.32399.Fhone:850487-1824 The State•pf Flgrfda is anAA/EEO e[nployd.Cbpvrdaht 200742013 State of ftida: ;Pri ny Statement,-*:'Accessibffity Statement.:.,Refund Staterrieht Under'Frorida faw,remali addresses are publ o7 on'lS ou do oofwant youre-mail,address rele5sed in response Lo?a public-records request;do not send electronic mail to this entity;"Instead.contact the.afffce,iryphone"or by 2radiUonaf.mail.I[you fta've.anj goesdons.please contact 650.487:1395, Pyrsuant to 5ectoiti 455.275(1),Florida Statutes,effective:Ocfober 1,.2012,Ilcensees licensed under Chapter'45S;.E5.must provide tlie:Department witfi-an email adtlress if they.fiave. one,The emalis ptogided maybe used for o(ficfai cortfmunicatlon w[th the lfiansee.However emailadd[esses are'public record.If yeu dp not WIsFi to=supply a."personal address,,please provide the Departrnerit with'.atremal`address which can bemadeavailabie to the public_Todetertnirie if you-area Iiceiisee�under;Ctiapter 455,F:S;, piease cllck't�g�g: PmductAPPr6-valAcceptm �.`CC�GIit° > t } -r5 DESIGN,UG: EXTERIQ.R RESEARCH,& Certificate of"Authorizarion#9503 TL'�IN�� 353 CHRISTIAN.S7REET,UNIT#1"3' ERP OXFORD,CT 06479 PHONE:1(203)262=9245. FAX:(203)262-;9243 :EVALUATION REPORT Owens.Corning Evaluation Report 037940.02.12-R7 :One Owens Corning Parkway FL10674-R22 Toledo,OH 43659 Date of issuance:D2/06/2612 Revision 7 D4/18/2016 SCOPE: This Evaluation:Report is issued under"Rule 61,620-3 and the applicable rules and regulations governing.the use of construction,materials in the State of Flonda.'The documentation submitted has been reviewed by Robert Mennen,. P;E> for use of the product under the Florida .Building Code and Florida Building Code,, Residential Volume. The, .products.described herein have been evaluated for compliance with the stn Edition.(2014) Florida Building Cade sections noted herein. DESCRIPTION; Owens Corning;Asphalt Roof Shingles LABELING: 'Labeling shall be;in.accordance with the requirements the Accredited Quality Assurance.Agency noted herein. CONTINUED COMPLIANCE: This :Evaluation Report is valid until such time as:the named product(s), changes, the: referenced Quality Assurance documentation changes, or provisions of,the.Code that relate t6 the product change. Acceptance of this Evaluation'Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product.changes Or the referenced Quality Assurance documentation changes. TrinityI'lE RA requires -a complete review of this,Evaluation'Reportrelative.to updated Code requirements,with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the.words`?r nityI ERD Evaluated" may be displayed in advertising literature. if any portion of.the Evaluation Report is displayed,then it shall be done in Its entirety.'. IN Upon request,a copy of this entire:Evaluation,Report shall be:provided to:the:use,r'by,the manufacturer or its:distributors;and shall be°available for.inspection at the job.site:at the request of the Building Official. This Evaluation RePort consistsof pages"1 through,8 Prepared 6y: t01%ittrttuy �.�``S�.»•:..1 lam'••, ,; J4t- The RobertJ:M,Nieminen,P.E. S�� . KLon 04/18/2gi6PTh does of serve asipearing was electroncally waned` Florida Regt`stm on No.s92b_6,Florida DCA ANE1983 Mgt st document,signed,seated hardtop es have been trbi smi ted to the Pmrluct Approval.Administrator and to the nameddent CERTIFICATION OONDEPENOENCE: 1, Trinity)ERD does;not.fiave;,nor does it intend to acquire or,Will if acquire,"a'financial interest inany company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not.owned,operated orcontrolled Ib a.ny company manufacturing ar distributingproducts it evaluates; 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued;, 4. Robert Nieminen,P.E.does not have,norwillacquire,a financial'interest in any other entity involved in the.approval process of the product:" 5 'This is a building code.evaluation. Neither TrinitylERD nor.Robert Nieminen,"P.E. are; in anyway,the Designer of Record for any project on which this-Evaluation Report,or previous.versions thereof,is/was used for perm,itting'or design guidance unless`retained specifically for that purpose. \410RINIVIERD, ROOFING SYSTEMS'EVALUATION: 1. SCOPE' ProductCategory: Roofing Sub-Category: Asphalt:Shingles Compliance Statement:: Owens"Corning Asphalt Roof Shingles,as produced by Owens Corning,"have demonstrated compliance with the following sections"of the Florida Building Code and Florida Building Code;.Residential'Volume through.testing in"accordance with the following Standards. Compliance is subject to.the Installation Requirements and Limitations/Conditions of Us`e set forth herein. I STANDARDS: Section Prope Standard Year 1507.2.5;R905.2♦4 Physical_Properties ASTM:D3462 2009> 1507.2.71,R905.2.61 Wind Resistance. ASTM D:3161 2009 1507.2.7.1,R905 2.6.1 Wind Resistance ASTM:D7158 2008 3. REFERENCES' Entity- Examination Reference Date UL LLC•(CER9626) Physicals&:Wind Resistance File 1124$3,Vol.3; 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516=112453 05/16/2012 UL LLC_(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC,(TST9628) Wind Resistance 11CA34308 02/18/2012 UL:LLC:(TST9628) Physicals&.Wind Resistance 4286093137 02/01/2014 ULLLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628)' Physical Properties Classification fetter 02/13/2014 UL LLE(7579628} Physical fEoperties Classification letter 10/02/2015 Miiami-0ade(CER1592) FBC HVHZ Cornpi lance Various NOAs Various UL'LLC (QUA9625) Quality Control Service Confirmation;R2453 Exp.08/20/2017 4: PRObucrDESCRIPTION 4;1 Asphalt Shingles: 4.11, Classic and Supreme are fiberglass reinforced,3'-tab asphalt It shingles. 4.1.2: Berkshire'are fiberglass reinforced,4-fab asphalt roof shingles. 4.1.3 Devonshire''are fiberglass,reinforced,5-tab>asphalt roof shingles. 4.1.4. Duration!, TruDefnition* Duration., Duration .Premium Cool, TruDefinition' Duration` Designer Color Collection,TruDefiriition`Oakridge`; Oakridge` and WeatherGuard` HP are fiberglass reinforced;:laminated. asphalt roof shingles. 4.2 Berkshire Hip& Ridge"Shingles, High Ridge,,WeatherGuard HP Nip&Ridge Shingles, ProEdge Hip&"Ridge Shingles and DuraR dge""Hip&Ridge.Shingles are.fiberglass reinforced,.hip and ridge asphalt=roof shingles. 4.3 Starter.Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof"shingles. S LIMITATIONS: 5.1 This is a building code evaluation. ,Neither Trinity-JERD not Robert Nieminen, .P.E: are, in any way,, the Designer of Record for any project on which:this�Evaluation Report,or previous versions thereof,-is/wa"s used for permitting or design guidance unless retained specifically for that purpose:" 5.2 This Evaluation Report is:not for use in the HVHZ. 5.3 Fire Classification is:not part of this Evaluation Report; referto current Approved Roofing Materials Directory for fire.ratings of this product. Exterior Research and Design,LLC_ Evaluation Report 037940.02AZ 117 Geroi/Pcdte;ofAiahoriradon.99503 FL10674=1112 Revision 7;:04/18/2016 Page 3 of 8 Q0TRINITY IERD 5:4 Wind ba: ssikation: SAI All Gwens:Corning shingles noted herein: are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1,to.ASTM P3161,Class F and/ot.ASIN! D7158j Class H..indtr 1 .4tfng the shingles are acceptable for use in all wind.zones up to V*=150 mph(Vu!t=194 mph): Refer to,Sedion 5 for installation requirements to meet this wind rating. All Owens Corning hip.&ridge shingles,Starter Strip Shingle.and Starter.-Strip Plus noted herein are::Classified iriactoeclairici?With.FBC Tables 1507.2.7i1.and R905.2.6.1.tbASTM 1)3161,Class F,indicating the shingles are, acceptable for use-in all-wind zones UP to Vasd=150 mph(VLlt='194 mph),: Refer to.Section 6 for insta.11a.tion requirements,.'to meet-this wind rating.. 5,43 Classification by ASTM D7158 applies exposure category to B or C and:a building height of 60 feet or less. o Calculations by a qualified'design professional are required for conditions outside these limitations. Contact the-,s-hingle manufacturer for data specific to e ach shingle. SA4 Refer to Owens'Corningpublished inforniationcri wind resistance and installation limitations. 5.5 All products in,the roofassembly shall have quality assurance;audit in accordance with the Florida Building Code and F.A.C.Rule 61G20 3. 6., INSTALLATION: 6.1 Viridedayrnefit: 6.1.1 'Underlayment shall be acceptable to Owens Ccirning and shall hold Current Florida StateWide Product Approval,or be LocallyApproved per Rule 61620-3,per Fl3(Sections i507,23,1507.2.4 or.11905.2.3. 6.2 Asphalt Shingles: 151.1 :Installation of asphalt shingles.shall comply with,the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ,> Berkshire shingles require minimum five.(5)nails per.shingle. > WeatherGuard HP shingles require.rnihimum-six(6),nails per shingle. > 'bevonshi 7' hi i I " - '*'-' I ' i ' - 'kI shingle... ffe, s, ing ps require minimum si, '(6)njiKper > Starterstfip Shingle and Start&'Strjo Plus-require minimum five`(5)nails per.strip. Referto Owens Corning published information on wind resistance and I installation limitations.. 6.2.2 Fasteners shall be in accordance with the.manufacturer's published requirements, but not less than FBC 1507.2.6.or 8905.2.5. Staples are not permitted. 61.4 Where the roof:slope exceeds 21 units Vertical 'in 12'units horizontal special methods of fastening are required; Seefigurd§beloW.forcletails. 6,12,5 Minimum.Nailing­Starter Strip Shingle and Starter-Strip Plus: Oak W.*dIwW uaa Weath"Low DCp 2-3 Mas Wcaud MOW* SOW.Baum A&Iel.M stutof$2 Sbda S*'dik4v-wf-w wv--d rak-W-V Exterior K"earch and De-sipjLc. Evaluation Repart 037940.02.12A7 0"dficaft 6tAvtha&at(0n 119563 FILI 0674-RIZ Re%ftion 7:04/18/2610 Rage 3 of 8 \,41-MNIT- YIERD 6.2.6, Minimum?Nailing=Classic®&Supreme: Mhnnaf Nisrmrd;or Ami Norma ManaarCor' *"POW ilMrndAeaa�. Hiph,Wlad dinianitr IM'iallrrF>ui ktpliH11nd Atm Oah•v�u!¢s;rariritt Mas vHnaos Apa para:;rfintai itoriiralsidannirrn K i Mua pi�fr;as'luut�a O'Maiiitf_ 8,818'!Eapowr . EkPask w I 6.2.7Minimum Nailing—Berkshire®t .. - - Snlm4rtrip $zalinEsf>fp'. LtAidaarladar Latiodrrdlsdor erh gyp eYr $�"` ` :atY eu^ s?�• eKtl } Standard Fastening Pattern 6-Nail Fastening Pattern Soatipls� . Or 'go tiBredexft�n fit•-►s•f-----�+s.:�.f--wrw--►� . 'y r r ` AsptwNtaviingcemeni . CI71:Cllfa ddirrilo dreitalfa Mansard or Steep Slope Fastening.Pattern Exterior Reseamh.and Design,LLC— Evaluation Report 037940.02.12=R7 CerWcate ofAuthorlradon 09503 FC10674-1112 Revision 7:.04/18%2016 Page 4,of 8 TPJNIV JERD 6.2.8. Minimum'Nailing—Devonshire'": 47 I Naas SaaF�tlocMlon Fav _ - _. si• Eicpa9ld6n de S flit ping Wadiia del allador sxfi• IbnfSpUc011 Rual Cement Standard 6-N,ail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing=Duration®,Tru Definition®.Duration, Duration® Premium Cool &.TruDefinition*Duration' Designer Color Collection: 4Nal{FastanUip Pitbio &Natt Fc tMng Patt*rn saefaa6tobabg� .. Standard Fastening Pattern 6-Nail Fastening Pattern" . ;Foltrn}gforSbPn6m2WThanit1:12:. -acr iWa l o,a anavi4h "TppIM i•. e• ,r aw-seise Mansard or Steep Slope Fastening Pattern Exterior Research and Design, LC. Evacuation Report 037940.02.12-R7 Certfcoteofauthadmdai#9503 FL10674-R12 Revision 7:04/18j2016 Page 5 of,& i TRINITY ERD 6.2.1 Minimum Nailing,—Tru Definition'OakridgeO,Oakridge®: �, 4Naii PxtKn :s Nail Pattani- FSOwn Fc�ost .Esgitamaemf.6dai{os' V 4 t 6619""6spaw�n fids �6t8"Eicpo��a rdaf� Expostdcrede66/8 ;'. Clvvas' Expostdditde55/Bpufg:, ; 66/8"FirposuR _ - Cdaro3 6616'Expowts FspasldbndeSS{B.pufgi Exposiard(rtk,Slil,Spitlg, Standard Fastening Pattern 6-Nail Fastening.Pattern Fastenleyfor::Ebpp"GteatitTRaif21:12` _ _ "M/dCt�ip4aF Awl _er, re: Fw sar , rwrl°'6/utaefllfyCs�RoghgC.nna. Mansard'or.Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuardo HP I.- fir-iN Exterior Research and Design,LLC. Evaluation Report 037940:02.12-117 Certificate'of Authadzution#9503 FL10674•R12` Revision 7:04/18/2016 Page 6 of 8 0'TRINITYIERD 6.3 Hip"&Ridge Shingles: 6.3.1 installation of Berkshire Hip and Ridge Shingles,High Ridge,WeatherGuard*HP Hip'and Ridge Shingles and ProEdge Hip'&Ridge Shingles shall comply with the:manufacturer's current-published instructions,using four (4) nails per shingle. Installation of DuraRidge'" Hip&:Ridge:Shingles shall comply with the..manufacturer's. current- published instructions, -using. two (2) nails per shingle. Refer to Owens Corning published. information on Wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with.the manufacturer's published 'requirements, but not less than FBC 1501.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshirem Hip.&Ridge and High Ridge: its 1 _... .� Figs. '- melon .:•.':. �u:-.: tup.NM:S SldaVl¢w: Nails p, r r r% C ti F 6.3.4 Minimum Nailing:—WeatherGuard®HP Hip and Ridge: ,��� . �9 C Hlp'.B�RidgeSfiitsgle Fa�iani`ii9': orwatnymna \ mpvgr, dalta 'u A .. l t. . Ntfq N�lti P; 1 A" r ! f :1 �1" l` t Exterior Research and Design,LLC. Evaluation,Report037940.02.12-117 Cerriftcate of AWod wdan#9503 FL10674-1112 Revision 7.04;(18[2016 Page 7 of 8 TRINITY I ERD 6.3.5. Minimum.Nailing-Pr6Edge Hip&Ridge Shingles: PtrpaQhig S��^ 11!—• wind uirktion � P�tbm ftg . . fee 71h* 8 Sk ., �` RNf Ceswirt x 6.3.6 Minimum Nailing-Dura Ridge'"Hip&Ridge Shingles: Note:The drawings.below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements: t�.�NAnl02rst�a raeen� f"eb�6inirninets,i�ent r l t ale ( 8 I 7. LABELING: 7..1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2;7.1 J-R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction.in.order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contactthenamed QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY.ASsURANCE ENTITY: UL LLC-QUA9625;(414),248-6409;karen buchmann(cDul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02,12-87 cenykate of,Amorist on#qs03: FL10674= R12 Revision 7:04/18/2016 Page 8 of 1 V' a w e P— .r.. .,. r, ,..p. _ tyre SCIS Home ( Cog in User Registration + Hot Topics"! Submit Surcharge Stats&Facts Publications WS Staff S Slte`Map Cinks i " Product Approval USER:.Public'User r<r Product Aoorwai-Menu>Product or Application Search>Application Lis t->Application Detail -�+. . YtM: FL# FL9777=R9 _t..aam".y: Application.Type Revision Code Version 2014- Application 014Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning.Parkway Toledo,OH 43659 '(740)404-7829: greg.keel,er@oyvens,comihg.com Authorized Signature Greg.Keeler greg.keelier@qwenscoming.com Technical Representative Address/Phone/Emaji Quality Assurance Representative, AddFess/Phone/Email Category Roofing Subcategory Underlayments Compliance'Method Evaluation Report from.a Florida Registered Architect or a Licensed F Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer of-Architect Name.who developed the Zachary R.Priest Evaluation Report ,Florida License PE-74021 Quality Assurance'Entity 0L LLC .Quality,Assurance.ContractExpiration Date 12/31/20`20' Validated By Locke Bowden, r; Validation Checklist-Hardcopy Received. Certificate of Independence FL9777 R9 COI OCR14002 6a FBC 2014 Evaluation Report Weather. Non-HVHZ FINAL:Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D.1970 2009. ASTM D 226 2006 ASTM G.155 2005 TAS 103 1995. UL1897 2004 Equivalence of Product Standards 4 Certified By .Sections from the Code 14 Product.Approval Method Method l Option D Date Submitted- 04/12/2017 Date Validated- 04/12/2017 Date Pending FBC Approval 04/13/2017 Date Approved 06/13/2017 Summary of Products FL# Model, Number or Name' Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation;Instructions Approved.for use in HVHZ:No FL9777 R9 II OCR14002 6a'FBC 2014 Evaluation n Repor Approved.for use outside:HVHZ;Yes Weatherlock'Non-HVHZ FINAL,12 Impact Resistant:N/A Verified By: Zachary R. Priest 749Z1 I Design Pressure:.N/A Created by Independent Third.Party:Yes Other:,See evaluation report for limits of use. Evaluation Reports I ` FL9777 R9 AE OCR14002 6a FBC 2014 Evaluation Regc i WeatharlockNon-HVHZ EML Created by independent Third"Party:Yes 9777.2 Weatherlock G (High Tear) Weatherproofing Underlayment, Limits of Use Installation Instructions Approved for use in HVHZ:Na Fl 9777 I29 II OCR"14002 6a FBC 2014 Evaluation Repor Approved.for use outside HVHZ Yes weatligrlock"Non-HVHZ FINAL pdf Impact Resistant-:N/A Verified"By.Zachary R..Priest PE-74021 Design Press re-:NIA: Created'by Independent Third Party:Yes Other:'See evaluaEion report for Ilmifs of use. Evaluation Reports. F077'7 R9 AE OCR14002 6a FBC 2014 Evaluawlon Repc Waatherlock Non-HVHZ FI I,NAI'odf i Created by Independent Third Party:Yes 9777.3 Weatherlock MAT 'Waterproofing Underlayment __. Limits of Use Installation Instructions { Approved for use in'HVHZ:.Yes F19777 R9 II OCkI4602 6b FBC 2014 Evaluation Repor Approved for use outside HVHZ: No, Weatherlock HVHZ pdf Impact Resistant:N/A Verified By:Zachary R._Priest.740Z1 j Design Pressure: N/A !Created by Independent Third Party;Yes Other:See evaluation report for limits of use. Evalu=ation Reports '5L9777'.R9.AE OCR14002 6b FBC 2014 Evaluation Repc � V!�atheriock HVHZ.i�df Created by IndependentThiird Party: Yes. !9777.4 Weatherlock.MAT.. Waterproofing Underlayment I limits of llse Installation Instructions Approved foruse_iry HVHZ:No 1=L9777 R9 II OCR14002 6a FBC 2014 Evaluation Repor. Approved°foruse outside HVHZ:Yes Weatherlock Non HVHZ FINAL.Pdf Impact Resistant:N/A Verified By Zachary R.Priest 74021 Deslgn Pressure: N/A 'Created by Independent Third Party:Yes Other:See evaluation report for'limits of use. Evacuation Reports. OL9777-R9 AE OCRt,4r}02 6a FBG 2014 Evaluation Repc I Weatherlock NO HVHZ FINAL pdf Created.by'IndependentThird Party;Yes 1`9777 S r- -- °Weakberlocfc.Metal Weatherproofing Underlayment h 1' Limits of Use. Installation Instructions: Approved for use In HVHZ:No k§777 R9 I1 OC�R14002 6a FBC 2014 Evaluation Repor Approved for use outside HVHZ:Yes Vlfeatherlock Non-HVHZ FINAL bdf _ Impact Resistant: N/A VerifiedBy.:Zachary R. Priest PE174021 Design Pressure: N/A Created.by independent Third Party.Yes, Other:See evaluation report for limits of use. Evaluation Reports 4 '171977'7, 114 AE QCR14002 6a"FBC 2014 Evaluation Reoa Certificate of-Authorization No..29824 C RE. 1 17520 Edinburgh Drive Tampa,FL 33647 TECl-MCAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE V EDITION(2014) Manufacturer: OWENS:CORNING ROOFING AND ASPHALT LLG Issued April 12;.2017 1 Owens Coming Parkway Toledo,OH 43657 (800)438-7465 www.owenscoming.com Manufacturing Location: Brentwood,NH Houston,TX Quality Assurance: UL LLG'(QVA9625)_ I SCOPE Category:o ryRoofing Subcategory: Underiayments Code Sections: 1504.3.1`,1507.2.4,1507:2.8, 1507.2.9.2,1507:3:3, 1507.4.5;,1507.4.5:2, 1507.5.3, 1507:5.3.2,1507.7.3, 1507.7.3.2 Properties: Physical properties REFERENCES E tity Remi No. Standard Year PRI''Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009 PRI Construction_Materials Technologies(TST6049), NEI-042-02-01REV2 ASTM D 1970 2009 PRIIConstruction Materials Technologies(TST6649) NEI- 045-02-01 TAS 103 1995 PRI Construction Materials T c.hnologies(TST6049) NEI-045-02-01 ASTM G 155, 2005a PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAI 103 1995 PRI Construction Materials Technologies(TST6049) NEI-053,=02.01 ASTM G 155 2005a PRI.Construction MaterialsTechnoidgies(TIT6049) NEI-093-02-02 ASTM D 1970 2009 PRI.Construction Materials Technologies,(TST6049) ' O.CF7213-02-01 ASTM D1623 2009 PRI Construction Materials'Techno(ogies'(TST6049)' OCF-237-02-01 UL 1897 2004 PRI Construction Materials Technologies(TST5878) OCF'-252-02-01 ASTM D-4798 2001 PRi Construction Materials Technologies(TST6049).. OCF=2 -02-01 ASTM:D 1970 2009 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2009 PRI tonsfniction Materials Technologies(TST6049) 0CF-272.02-01 TA5103 1995. .PRI Construction Materials Technologies(TST6049). OCF-296-02-02 ICC ES AC-188' 2012 ICC-ES AC 48 2012 PRI.Construction.Materials.Technologies(TST6049) OCF=297=02-01•.1 ASTM D 1970 2009 'Determined to be equivalent to ASTM D 226.06,Type I and 11 i OC_R14002.6a F1-9777-149 Page 1 of 4 This evaluation report is provided for State of Florida product approval;under Rule'61G20-3..The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance,changes throughout:the:duration for which-this,report is valid: This evaluation report does riot express nor imply.warranty,installation,"recommended use,or other product attributes that are not specifically addressed herein, c J - CREEK OWENS-CORNING ROOFING AND ASPHALT LLC WeatherLock®Self-Sealing Ice&.Water Barriers TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND.UmITS OF.USE WeatherLock@ G WeatherLock®G is,an ASTM D 1970 self-adhesive underlayment constricted from SBS. (Brentwood NH) modified asphalt. a fiberglass mat reinforcement and surfaced with granules. The product is supplied in.2-sq.rolls with nominal dimensions of 3-ft x•66.7-ft. WeatherLock®:G is permitted to be used with mechanically'fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC; Exposure on the roof.deck"shall be limited_to a maximum 30 days. WeatherLockOD Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood NH or SBS:"modified;asphalt with a fiberglass mat reinforcement. The product is:supplied in 1- Houston; TX) sq.rolls with nominal dimensions of 3-ft x 3137ft and 2 sq.rolls with nominal dimensions :of 3-ft.x 66.7-ft. i WeatherLock®Mat is permitted to be used with mechanically fastened asphalt shingles, Wood shakes or:shingles, and slate roofing.as:prescribed in the FBG Exposure on the roof deck,shall be limited to;a.maximum 30.days. WeatherLockO Metal WeatherLock®Metal is an ASTM D 1970 self-adhesive underlayment,constructed from (Brentwood,NH) ;SBS,modified.asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied"in 2.0 sq.roils.with nominal"dimensions of.3-ft x-66.7-ft. WeatherLock® Metal .is permitted to be:,.used with mechanically'fastened asphalt shingles, metal roof'panels or shingles, wood's.hakes or'shingles, and siate-roofing as prescribed;in the FBC: Exposure'on. the roof deck shall be limited toa. maximum 90 days. WeatherLock® WeatherLock®Specialty Tile& Metal is an ASTM D 1970 self=adhesive underlayment Specialty.Tile&Metal constructed from• SBS,modified asphalt and,surfaced with a non-woven polyester fabric. (Brentwood,•NH) The product is,supplied'in 2.14 sq..:rolls.with nominal:dimensions of 3-ft x 71.3-ft: WeatherLockO Specialty Tile&Metalis permitted to be used with mechanically fastened asphalt shingles, clay or.concrete tile, metal roof panels or.shingles, wood shakes or shingles, and slate roofing"as prescribed in.;the FBC. WeatherLock® Specialty Tile A: Metal is permitted to-be used with adhered cl.a or concrete tile roofing using either 3M m y 9 9 II 2-Com one t.Foam Roof Tile Adhesive ve AM-1.60 (3 M Company) TILE BONDTm Roof. Tile Adhesive,.(The Dow CherricalCoirpany). Exposure on the roof deck-shall be limited to a maximum 90 days. The maximurn roof slope shall be 6:12 when used with.clay or concrete file installations without"battens: Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be'stacked greater 10 tiles per stack; . WeatherLock®,G(High WgatherLock®G(High Tear.)is a' self-adhered,underlayment used as an alternative to Tear). ASTM D'226,Typed or Type ll:roofing felt and ASTM D 1970 self-adhering polymer (Houston; M . modified bitumen-underlaymen.t. The underlayment is composed of SBS'modified asphalt with a,fiberglass maty intemal reinforcement,and is,surfaced with.granules..The product is supplied,with a nominal thickness of 50 mils in 1.95-sq rolls.with nominal dimensions of 3-ft x 65-ft. WeatherLo. k@ G(High Tear).is;permitted,to be used:with mechanically'fastened asphalt shingles,metal roofing,slate shingles,wood shingles and wood shakes as prescribed in the.FBC.: Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.6a FL9777-R9 Page;2 of 4 This evaluation report is provided for State of'Florida product approval.under Rule 611320-3. The manufacturer.shall;notify CREEK Technical Services,LLC of any product changes-orquality assurance changes throughout the:duration:for which this report is valid- This evaluation report:does rtot'exp`ress nor imply warranty;installation,recommended use,or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLC p CREEK WeatherLockO Self-Sealing Ice&Water Barriers TECHNICAL SERVICES,LLC PRODUCT APPLICATION Min.Roof Slope: 2::12 or in accordance in with the FBC Application: All undedayments shall be'installed in accordance with the FBC. beck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shalt be checked for protrusion"and corrected'pdor to underlayment application. Prior to beginning installafon, the underlayment shall be unrolled and .allowed_to relax.fora minimum of3.5.minutes:. The underlayment shall be installed with:the.release backer removed and pressed firmly into place to ensure complete contact with,the deck.The'underlayment.shall be installed with the roll length parallel to the eave, starting lat the,save, and with minimum 3"side, laps and minimum 6"end laps staggered'min..6-ft.from preceding;course. Additionally,if applying WeatherLock®Specialty Tile &.Metal; end.daps "shall be primed with:ASTM D 41 primer or sealed'with-asphalt "roof cement_A minimum of 3..4 inches across the width of the lap:. Itis permissible to back nail:the undedayment 12-4nchesoh-center as needed(nails shall be installed.perpendicular to deck.with the nail heads flush. to the:top surface of the underlayment). Additionally,Weathe.rLock®Specialty Tile &.Metal shall be back.nailed when:installed on roof slopes greater than 312..• Min.Application 40°F;Contacfthe manufacturer when installing at temperatures below the minimum Temperature:r application temperature. WINO RESISTANCE The Maximum Design Pressures shown.below were calculated using.6'2:1 margin of safety.per FBC Section 1504.0. Underlayment'System No. —WeatherLock Specialty Tile&Metal Oniv Roof Deck: Min. 15(32 hch_CDXplywood,attached to wood;supports spaced a maximum 24"ox. Linderlayment:: WeatherLock® Specialty Tile & 'Meta( Shall be applied in accordance with. manufacturer's installation instructions to the'"fastened deck and backnailed along the selvage with minimum 12ga:, 1=1l4-inch galvanized .ring shank roofing nails"through op (ionally primed; 32ga x 4-518-inch fD `tinps spaced 12° o.c. The applied undedayment shall; be rolled with a minimum; 15Ib."steel roller immediately following application. Maximum Design -1.05 psf Pressure: OCR14002,.6a FL9777-R9 Page 3 of 4 This evaluation.report is provided:for State of Florida:product approval under Rule 61 G20 -3. The manufacturer shall notify,CREEK Technical Services,LLC of any product changes,or quality assurance charxjes throughout the duration for which this-report is valid. This evaluation report does not express nor"imply warranty,installation,recommended,use,or other product attributes that are not specifically addressed-herein. , j OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLock®Sel"ealing Ice&Water Barriers- TECHNICAL:SERVICES,,LLC GENERAL LIMITATIONS' 1) This-eValuation:report is not usein:the HVHZ. 2) Fire Classification isnot within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,;and the manufacturer's published' application.instructions. .Where discrepancies exist between these sources, the more restrictive and FBC compliant-installation detail shall prevail. 44 `The:roof deck shall be constructed of closely fitted plywood:sheathing.for new or existing construction. 5) The space underthe deck area shall-be properly Ventilated in.accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck.. 7) The,undiadayment maybe used.as described,in,other current,FBC product approval.documents. 8) Design wind load .pressures:shall be determined for components and cladding in accordance .with-FBC 1609. 9) The roof deck:shall be designed by others'in;accordance with FBGrequirements to resist the design wind 'load pressures for components and cladding. 10) Maximum Design Pressures for a given und0d8yntent shall meetor exceed the design wind loads determined for th'e roof assembly., 11) All products-listed'in chis report shall be manufactured under quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE.STATEMENT The products.evaluated-herein by-Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 5u'Edition(2014)as-evidenced in the referenced-documents submitted by the named-manufacturer. R. ..;� G ENSU;FS. 201 7.0`t.1 2 74:02 N'o *: 15:15;46 S1ATE OF '04'0.0' r 00O kW Zacha R Priest,P.E. R• S Floud Registration No.74021. 'N AL Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE GREEK Technical:Services,LLC does not have,nor will it acquire,a financial interest i-n any company manufacturing or distributing products undecthis evaluation. CREEK Technical Services,LLC is,not owned,.operated,or controlled by any company,manufactudng or distributing products under this evaluation., Zachary RS Priest, P.E.does not.have,nor will acquire, a financial:interest in any company manufacturing or distributing products under:this.evaluation. Zachary R.Priest;P.E:does not-have;nor will acquire,a financial interest in any otherentity involved,in the approval process of the product.. • 1 r : END OF REPORT OCR14002,6.a FL9777-R9 ;Page 4 of 4 This evaluation report is provided for State.of Florida product approval under Rule 61_G20-3. The manufacturer-shall notify CREEK Technical Services,LLC of-any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not.express nor imply warranty,:installation,recommend'ed'use,or other product attributes:that are not specifically addressed herein: