Loading...
HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Permit Number: Date: �s Building Permit Application Planning and Development Services Building and Code Regulation Division 23oo vIrginia Avenue, Fort Pierre FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential PERMIT APPLICATION FOR: _ PROPOSED IMPROVEMENT LOCATION: Address: 5202 PALMETTO DR FT. PIERCE FL 34982 Legal Description: INDIAN RIVER ESTATES - UNIT 05 - BLK 24 LOTS 13 14 15 AND 16 Property Tax ID #:3402-606-0081-000-4 Lot No. 13-16 Block No. 24 Site Plan Name: Project Name: FRANK & BETTY BROWN Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: Replacement Windows (12) CONSTRUCTION INFORMATION: itiona wor to er orme under tis permit—c ec a appy: ❑ HVAC GasTank ❑Gas Piping _Shutters windows/Doors Electric Plumbing OSprinklers GeneratorRoof Ft Total Sq. Ft of Construction: S�'F't'j. of First Floor: OSeptic Building Height: Cost of Construction: $ 20,000.00 Utilities: OWNER/LESSEE: CONTRACTOR: Name FRANK &BETTY BROWN Name: Sam Ochstein Address: 5202 PALMETTO DR Company: Newsouth Window Solutions City: FT. PIERCE State: FL Address:2526 Okeechobee Blvd. City: West Palm Beach State:FL Zip Code: 34982 Fax: Phone No. 772-466-9512 Zip Code: 33409 Fax: 561-478-4100 E-Mail:BETTYBRN�BELLSOUTMNET Phone No. 561-712-9000 Fill in fee simple Title Holder on next page ( if different E -Mail: westpalmbeach�newsouthwindow.com.com from the Owner listed above) State or County License: CRC1330822 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. Name: Address: City: State: Zip: Phone: FEE SIMPLE TITLEHOLDER: _ Not Applicable Name: Address: City: Zip: Phone: MORTGAGE COMPANY: _ Not Applicable Name: Address: City. State: Zip: Phone: BONDING COMPANY: _Not Applicable Name: Address: City Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie Cour�cyy makes no represer�Wtlon that is granting a permit will authorize these holder to build the ubJect s�ryGture which k in conflict with any�r applicable Home Owners Association rules, bylaws or and covenants that may restrict or pro ibtt such structure. Please consult vath your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work In accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before Signature ner/Agent/Lessee STATE OF FLORIDA`` COUNTY OF ' 0(i 'a The forgoing Instrument was acknowledged before me this day of20 11 by M STATE OF FLORIDA COUNTY OF The forgoing instrument was acknowledged before me thk;aday of 20-0 by 1:J nth " ka rCM,6� -,AM cl&ck-�L\ {Name of person acknowledging) (Name of person acknowledging) l.1Ati gim_x S6"_.0_ . (Signature of Notary Public- State of Florida) (Signature of Notary Public- State of Florida } Personally Known OR Produced Identification da'Personally Known OR Produced Identification Type of Identification Produced- . — a �..1L Type of Identyttxti n Produced Commission No. K52 Commission No. w� M A. STONE p KIM A. STONE Me��: 0c"I5, 2019 %v d g7(pIRFS "''°'S. X079 Revised 07/15/201 g°+a w' REVIEWS FRONT COUNTER ZONING REVIEW SUPERVISOR REVIEW PLANS REVIEW VEGETATION REVIEW SEATURTLE REVIEW MANGROVE REVIEW DATE COMPLETE INITIALS NewSouth 2526 Okeechobee Blvd. a West Palm Beach, FL 33409-4006 WINDOW oLunorNs 561-712-9000.561-478-4100 fax www.NewSouthW!ndow.com Lic# CRC -1330822 Made in Florida/torr Florida I olnes Date Is!/uA To E-mail o44y6AA1 n/iI a (Pile Home Pe?/S�CeII .7KD T Phone city PtIP _State Zip ! Business(Mr./Mrs.) I.t Replacement Windows a Entry & Patio Doors • Storm Doors • Impact Resistant Windows & Doors 5 jo WHOLESALE & RETAIL WINDOW CONTRACT l NewSouth Window Solutions agrees to measuremanufacture or furnish and service the following custom made windows for the amount STIPULATED BELOW: All NewSouth Vantage Series Windows include Double Pane, Low -E glass with Argon gas, and 12 point fusion welded corners All Vantage windows are sealed and vacuum testedf rsuperio' argon retention. Colaro(wholewindow) Ire ❑Tan ❑&onue(esterioronlyl Interio.[olors Whke ❑Tan minm Colars mryvarysll h fmmsam k (InMall LOW-EGLASS: ❑366 GLASS GLASS OBSCURE GLASS ❑YES XNO TEMPERED GLASS❑YES O I ALL SASHES ARE ARGON FILLE - ITHOUT EXTRA CHARGE LOCATION: LOCATION: m Ro r GflIDS GPSiYLFIp56 ❑ eVantage ❑ CVantage9000 Single Hung lyantage 9000 Impact [3 other: ",vim DOUBLE HUNG E -VANTAGE ❑ (HALF -SCREEN 6TANDaRD)0FuII5oeen °unNrm PATIO DOORS Olmpac[Dnon-impact ❑Open Praire Grids SINGLE CH ❑ on SINGLUNG E 900051NGLE HUNG (HALFSCREEN) HUNG ❑ Impact O nonimpan Indicate sire,drewarmwsfoMirecdon Cl 5/0X6/8 ❑ 9/0X6/8 of slide outside looking In RAU) 05/0X8/0 09/0X8/0 ❑ 6/0 X 6/8 ❑ 12/0 X 6/8 2 LITE SODER E -VANTAGE ❑ 9 DO(, HALF -SCREEN STANDARD) O Full Screen 9000 SLIDER Xw 0 X ❑ outsiee ,in pact 13. Pact ❑ 6/0 X 8/0 ❑ 12/0 X 8/0 ❑ 8/0x6/8 1316/0X6/8 ❑ 8/O x am ❑ 16/0 X 8/0 PICI TUBE WINDOW-lrnp VANTAGE (NOSCRMN) Impact 0 non -Impact 3 PANEL PATIO DOORS ❑impact otwnimpact 3 LITE SLIDER WITH PICTURE �t WINDOW DSCREENS) ��'��' diute Mae.drawarmws iordirecdon aside ovudde looking In vl 0nem X171- O nanimpact X171-1— /4-1R-1/4 configuration 4 PANEL PATIO DOORS ❑ Impact ❑non -impact fAWNING &HOPPER ® CASMENTIOSL) =HiNG 100aRRIN[ f_DOUBLE CASEMENT 00 Indkateawarro(ordirection oside outsideualungin0 O impact D non -Impact ❑ HALF ❑ EYEBROW a ❑ QUARTER -ROUND ❑ TRAP ❑ OTHER ROUND (DRAW IN SPACE) [I GRID STYLES ❑STANDARD ❑CONTOUR ❑BRASS/GOLD/PENCIL Was MbhomebmhpriormlWai Dm No/ ❑Colonial ❑PralNe ❑Open Prairie Ifyes,dheundersigsedagresstothe rkwnditiomofthe NewSouth (eM Sah Work PrMlcesAdde um.Xhoure tests parties fixlead,ma ftionals6sparwiMmmobeaddedtothe WWnce. auyeYS Si4gluse/ TOTAL NUMBER OF WINDOWS ON THIS ORDER TOTAL DOORS: *" Subject to NewSouth field engineering and approval. o 0 �Cl Tde5 ., ha ieJoG�e S o e a ❑ Customer agrees to allow NewSouth to display a yard sign until 30 days after completion. TWOYEARS FREE IR NOME SERVICE BUYER'S RIGHT TO CANCEL BUYER MAY CANCELTHIS CONTRACT BY DELIVERING WRITTEN NOTICE TO THE SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. BUYER MAY USE THIS CONTRACT AS THAT NOTICE BY WRITING') HEREBY CANCEL" AT THE BOTTOM AND ADDING BUYER'S NAME AND ADDRESS. THE NOTICE MUST BE DELIVEREDTOTHE SELLER ATTHE ADDRESS SHOWN ABOVE. Total price*'A $ 0 D� o Down payment. [ K lw� $ -2 - 0 0 0 Delivery/commencement $ Balance due upon final $ window/door installation. )I Bank Financing ❑ Cash on Completion NewSouth WINDOW SOLUTIONS Fi 33e09. 561 -n9 -9n00 • CRC1330822 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 5th Edition (2014) Florida Building Code. Page 1 of 1 2526okeecnooee nrva, 11-11,111 II -- -- -- Property Information Buildin Information Owner: FRANK & BETTY BROWN Wind Zone: 170 MPH. C Address: 5202 PALMETTO DR Exposure Category: Minimum Building Dimension: 25 ft. FT. PIERCE, FL 34982 Mean Roof Height: 15 ft. Risk Category: II Desi n Pressure Calculations Opening Location Device Device 77FD Max Positive Pressure (psf) Max Negative Pressure (psf) Number Zone Width (in) Height (in) Elevation (ft) 1 Int 25.75 62 7 -- 37.5 40.7 2 Int 52 - 62 7 35.8 -39.0 3 Int 52 62 7 --- 35.8 39.0 4 _ Int 36 _ 62.25 7 36.7 39.9 5 Int 36.25 62 7 -_ 36.7 - --39.9 6 int 73 37.5 - 7 36.2 - ---39.4 7 int 52.5 49.5 7 36.3 _ -39.5 g Int 105.5 49.5 7 34.6 _ -37.8 9 int 52.5 49.5 7 36.3 -39.5 10 Int 105.5 49.5 7 - 34.6 -- 37.8 - 11 - --Int 36 37.25 7 37.8 _- -41.0 - - - t Int 36 49.5 7 37.3 -40.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 5th Edition (2014) Florida Building Code. Page 1 of 1 .1 Professional Regulation 1 13CIS M.. 1 Log In I User Registration I Hot Topic; Submit Surcharge I Stats & Pacts i Publications paC Staff 1 SCIS Site Map unks I Search, Product Approval USER: Public user s ,pr Moduct Approval Menu > Product.4f FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method > Application Lis r > Application Detall FL16842-R3 Revision 2014 Approved O NewSouth Window Solutions 4901 oak fair blvd tampa, FL 33610 (513)284-0129 danochstein@newsouthwindow.com Vivian Wright rickw@rwbldgconsulta nts. com Windows Horizontal Slider Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Q Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE -43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By Ryan J. King, P.E. O Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Leif)• ra Standard AAMA/W DMA/CSA101/I.S.2/A440 AAMA/W DMA/CSA101/I.S.2/A440 ASTM E1886 ASTM E1996 ASTM E1996 TAS 201, 202, 203 Year 2008 2005 2005 2006 2005 1994 Product Approval Method Method 1 Option D Date Submitted 12/20/2015 Date Validated 01/14/2016 Date Pending FBC Approval 01/18/2016 Date Approved 04/12/2016 Date Revised 04/11/2017 Summary of Products Go to Page 0 0 Page 1/ 2 0 0 FL # Model, Number or Name Description 16842.1 a. 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use In HVHZ: No EL16842 R3 II Inst 16842 1 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.1 for Design Pressure Ratings, any FL16842 R3 AE Eval 16942.1.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.2 b. 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16642 R3 II INST 16842.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 2 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.3 c. 9550 Slider XO - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842 3 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 3 odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.4 d. 9550 Slider XO - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use In f1VHZ: No FL16842 R3 II Inst 16842 4 Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.4.pdf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.5 e. 9550 Slider XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a HVHZ Nail Fin Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL16842 R3 11 Inst 16842.5ydf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 5 odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.6 f. 9550 Slider XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window with Flange HVHZ Installation (XO or OX configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R3 II Inst 16842.6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.6.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.7 g. 9500-3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842.7.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.7 for Design Pressure Ratings, any FL16842 R3 AE Eva] 16842.7.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.8 h. 9500-3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 lI Inst 16842.8.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.8 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.8.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.9 I. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II Inst 16842.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.9.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.10 J. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact' Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16842 R3 II Inst 16842.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.10 for Design Pressure Ratings, any FL36842 R3 AE Eval 165A2.1o.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.11 k. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a - HVHZ Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes EL16842 R3 11 Inst 16842.11.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.11.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.12 1. 9550-3 Slider XOX - Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with Flange - HVHZ Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16842 R3 II Inst 16842.12 Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.12 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842.12.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.13 m. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16842 R3 II INST16842.13.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R3 AE Eva[ 16842.13.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.14 n. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window ()(X, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842.14.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.14 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 14 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.15 0. DuraGard - 3 slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No fL16842 R3 II INST 16842 15 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 15 odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.16 P. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No F116842 R3 II INST 16842 16 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.16 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 16.0df additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.17 q. Sashllte Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XX, confguration) Limas of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842 17 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 17.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. 16842.18 r.Sashlite slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R3 II INST 16842 Approved for use outside HVHZ: Yes Verifled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant! No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 18 odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. 16842.19 s. Sashllte - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nail Fin Installation (XOX, configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL16842 R3 II INST 16842 19 odf Approved for use outside HVHZ: Yes Verlfled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 19 odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 16842.20 t. Sashllte - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XOX, configuration) Limits of Use I Installation Instructions Approved for use In HVHZ: No FL16842 R3 II INST 16842.20.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R3 AE Eval 16842 20 odf additional use limitations, installation instructlons and product Created by Independent Third Party: Yes Go to Page v • O Page 1 / 2 Beck Pleat Corona Us :: 2601 Blair store Road Tallah-Sme F L 32399Phone: 850-487-1824 The State of nonce Is an AA/EE0 employer. C^_nvrbht 2007-2013 SLte of Florida.:; Privacy Statement :: AcrassiNllN Statement :: Refund Sd m nt Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail M this emity. Instead, contact Me of icil by phone or by traditional mail. If you have any questions, please contact 850.487.1395. •Pursuant m Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If May have one. The emalls provided may be used for official c mmunipabum with Me licensee. However email addresses are public record. if you do not wish to supply a personal address, please provide Me Department with an email address which on be made available to Me public. To determine r you are a licensee under Chapter 455, F.S., please click bEL. Iroduet Approval Accepts: ®® M Credit Card Safe ,VI VI 5a95 µyppy PE9NAWMA-RWW AW6uR APP"Alk-IW42H Nondl M-W-DrF-4A- 16N2 CA14W-1660214.dry, ft -169626 N A W N nTO i 0 0, 3 l0 �. Z i A. mo�M<g 0 B. B.ff m ;6 m� o 0 P$o �3 iI Ii 3 gaQ Cr am 010ro0 o C's $' ma COs jn �n m'n l a ma '� �.a On °. n 3 Ip D a° ° a N ig �EF m 3 c o 6f MAX OVEPALL FLING >< R L1 G 0 m cr cr m y 'woo � pl1$cmruly',l R QG ; E(` A NeWSCYth tynaen F. Sanmmt •'+RCw9p ^`� 3 P.E. ftAL + $ y m 2 12 17 15 EVl9E MODEL NAZI ADD O2AZ1N UH PARE OB AaFMMY, BUIIDIPoG CONSULTMIlhl INC. N I5 �. 1 8 25 15 UPDATE TD 5TH ED. 2016 FE.0 Ifsll P.O. Ben 230, VOW , R 33595 �` NO DATE gy PIMu� � AW DE$IDNND� Ph .. No.: 513.689.9197 HEVIWUNS .MZ CA No. 9813 O ama 9.w. e�,.eae oaw.o..as i.�. E HEN'.Hf 67 MAX FRM1E HEIGHT >C A B.y,,,aN,.wh,Neer.mBrNs„N•N.,.„oliQNpwolpt4o�CNNa,rlYC- I�%�'�-t � r .. la ILI p ° u `\ �y O 401 111 M O r V N if a r s N T �o p 7• N �Q� i� n N b N N p p N4 i • a a II + _ 1.1/f MN. •i. a m w >•.. EMB. ("j • N Be. (Tv?.) s s • :J```V� tVBw- �p4�: I3*. °y.�'�"�` y i 6 N N.Wsouth p E ia�fa i N" 11 R r y o t 17 1 AIODO. Nb X M OR ISSEWDLY, ,nilmlo CO,/&RT ,NIIf Iliia "", 1,_ N `S Sf 1 lE T0. EA Xlff FBC US YERNGV- R It�ONfK �W vA. BN f]0. Whb4 R 33M f 4 RgrM Nos It AlCastn CROSS SFC0016 .,evE G Na pts no, 4 ,1.w. 0. owra�uin ,�o. 11 9W y b 2 iT 1915mam,YOOp. PAN ORI.�LY: WLDWo CONWLTNTIB, OIC. I / iD STN E0. 2014 f8C If3 BINAC R FRAME P.O. Bay M. V"m m 316G6 ��p nww w.� slamoAtn .flE C.A. Nw 111113 O ><o�♦ •.w, �uxnw� oe��uarnr� u.e. A C. 1 a 0A fi:-0.2r r---ro e. 0� obr w ti I 034' 1 111 tilt, BIAlDM6 WN6ULTANM M 0ANOIGMPhFw Ne. 013.WSAI" .rex CA M "13 RW R W Building Consultants, Inc. Consulting and Engineering Services for the Building Industry B C P.O. Box 230 Valrico, FL 33595 Phone 81 3.659.9197 Florida Board of Professional Engineers Certificate ofAuthodretion No. 9813 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions 9550 Slider XO Windows Horizontal Slider 4901 Oak Fair Blvd Impact Rated -HVHZ Tampa, FL 33610 wl Flange 813 626-6000 Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for NewSouth Window Solutions, based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Dept. of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ", this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL -16842.6 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL -16842.6 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 02031488 TEL 02031489 2. Miami Dade NOA 14-0423.16 3. Drawing No. No. FL -16842.6 Test Standard Testing Laboratory TAS 201, 202, 203-94 Testing Evaluation Lab. TAS 201, 202, 203-94 Testing Evaluation Lab. Materials Testing Saflex® PVB Interlayer (Eastman Chemical Co.) Prepared by RW Building Consultants, Inc. (CA #9813) 4. Calculations Prepared by Anchoring RW Building Consultants, Inc. (CA#9813) „�ttrtttF��t At ASTM El 300 Glass Load Lyndon F. Schmidt, P.E. 0 gCii ������ F• ' E Nt'/C 5. Quality Assurance � ��G $F. Certificate of Participation issued by National Accreditation and No 43409 Management Institute, certifying that NewSouth Window Solutions is manufacturing products within a quality assurance program that complies e with ISO11EC 17020 and Guide 53. 90�, STATE OF �.. o ��. F•� . � OR IV Sheet 1 of 1 Signed by William B. Shelton, P.E. William B. Shelton, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. FL PE No, 43409 1/1312016 6/1/2017 Florida Building Code Online III all Business & Professional acts Home I Login I User Regitraaon I Hot Topics Submit Surcharge Stats a Fats publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Protluct Approval Menu > Product or Application Search > Application List > Application Getall FL ff FL15054-R4 Application Type Revision Code version 2014 Application Status Approved Comments 01/19/2016 v date. set to reapply per R. Wrights req. zb 01/21/16 Archived Product Manufacturer NewSouth Window Solutions Address/Phone/Email 4901 oak fair blvd tampa, FL 33610 (513) 284-0129 dartochstein@newsouthwindow.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt the Evaluation Report Florida License PE -43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By Ryan J. King, P.E. d Validation Checklist - Hardcopy Received Certificate of Independence FL15054 R4 COI Certificate of Independence odf Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2005 AAMA/ W DMA/CSA101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2008 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15054 R4 Eauiv of Standards (FL 15054) Ddf httpsltnwidabui lding.orgtpr/pr_app_dtl.aspx?Wam=wGEVXQwtDquS73Fr2ZyiPl8Ew9YUwBR2BM UZOak2fzDBickyATMkXBrJAQ/o3dP/o3d 1/5 6/1/2017 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Building Code Online Method 1 Option D 12/14/2015 01/24/2016 01/26/2016 04/12/2016 FL# Model, Number or Name Description 15054.1 a. DuraGard Fixed Window Extruded Vinyl Direct Glazed "Non -Impact' Fixed Window utilizing a Nall Fln Installation (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS054 R4 II Inst 15054.1.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.1 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.1.odf additional use limitations, Installation Instructions and Created by Independent Third Party: Yes product particulars. 15054.2 b. DuraGard Fixed Window Extruded Vinyl Direct Glazed "Non -Impact" Fixed Window (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II Inst 15054.2. uGr Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.2 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.2.odf additional use limitations, Installation Instructions and Created by Independent Third Party: Yes product particulars. 15054.3 c. TrustSerles Fixed Window Extruded Vinyl Direct Glazed "Non -Impact" Fixed Window utilizing a Nail Fin Installation (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS054 R4 II Inst 15054.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.3 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.3.pd additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 15054.4 d. TrustSeries Fixed Window Extruded Vinyl Direct Glazed "Non -Impact" Fixed Window (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II Inst 15054 4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.4 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.4.odf additional use limitations, Installation instructions and Created by Independent Third Parry: Yes product particulars. 15054.5 e. Sashlite Fixed Window Extruded Vinyl Sash in Frame Glazed "Non -Impact' Fixed Window utilizing a Nail Fin Installation (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FLIS054 R4 II Inst 15054.5 odf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.5 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054 5 odf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. 15054.6 f. Sashiite Fixed Window Extruded Vinyl Sash in Frame Glazed "Non -Impact" Fixed Window (O configuration) Mlpsllfloriddxdldirg.orglpr/pr_app oaspx?pararn=wGEVXQwtDquS73Fr7ZyiPi8Ew9YUWBR2BMUZO%2fzDBklc(ATMk)BrJA%3d%3d 215 611/2017 Florida Buildi ng Code Ondine Limits of Use Installation Instructions Approved for use in HVHZI No FL15054 R4 II Inst 15054 6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.6 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054 6 odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 15054.7 g. DuraGard fixed Window Extruded Vinyl Direct Glazed "Impact" Fixed Window utilizing a Nail Fin Installation (0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II Inst 15054 7 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Inst 15054.7 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.7.odf additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 15054.8 h. DuraGard Fixed Window Extruded Vinyl Direct Glazed "Impact" Fixed Window with Flange (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II Inst 15054.8.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Inst 15054.8 for Design Pressure Ratings, any FLI5054 R4 AE EVAL 15054 8 odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 15054.9 1. 4600 Fixed Window Extruded Vinyl Direct Glazed "Non -Impact" Fixed Window utilizing a Nail Fin Installation (O configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL15054 R4 II Inst 15054.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.9 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.9.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 15054.10 ). 4600 fixed Window Extruded Vinyl Direct Glazed "Non -Impact" fixed Window with Flange (O configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL15054 R4 II Inst 15054.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Inst 15054.18 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.10.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 15054.11 k. 4650 Fixed Window - Impact Extruded Vinyl Direct Glazed "Impact" Fixed Window utilizing Rated - HVHZ a Nall Fin Installation (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15054 R4 It Inst 15054.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.11 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.11.odf additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 15054.12 1. 4650 Fixed Window - Impact Extruded Vinyl Direct Glazed "Impact" Fixed Window with Rated - HVHZ Flange (0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15054 R4 II INST 15054,12.0 Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.12 for Design Pressure Ratings, any FLI5054 R4 AE EVAL 15054 12 odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 15054.13 m. 9600 fixed Window Extruded Vinyl Direct Glazed "Non -Impact" fixed Window utilizing a Nail Fin Installation (0 configuration) hllps:lMoridalxiiding.orglpr/pr app dtl.aspx7param=wGEVXOwtDquS73Fr2ZyiP18Ew9YUwBR28MUZO%2fzDBlcbWTMk)(BrJA%3d%3d 315 6/1/2017 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II INST 15054 13.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports other. See INST 15054.13 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.13.0df additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 15054.14 n. 9600 Fixed Window Extruded Vinyl Direct Glazed "Non -Impact" Fixed Window with Flange (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II INST 15054.14.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon R Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other. See INST 15054.14 for Design Pressure Ratings, any FLIS054 R4 AE EVAL 15054.14.odf additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 15054,15 o. 9650 fixed Window - Impact Extruded Vinyl Direct Glazed "Impact" Fixed Window utilizing Rated a Nall Fin Installation (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II INST 15054.15.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.15 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.15.Ddf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. 15054.16 p. 9650 Fixed Window - Impact Extruded Vinyl Direct Glazed "Impact" Fixed Window with Rated Flange (0 configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15054 R4 II INST 15054.16.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.16 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.16.odf additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 15054.17 q. 9650 fixed Window - Impact Extruded Vinyl Direct Glazed "Impact" fixed Window utilizing Rated - HVHZ a Nail Fin Installation (O configuration) Lim@s of Use Installation Instructions Approved for use In HVHZ: Yes FL15054 R4 II INST 15054.17.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.17 for Design Pressure Ratings, any FL15054 R4 AE EVAL 15054.17.odf additional use limitations, Installation instructions and Created by Independent Third Parry: Yes product particulars. 15054.18 n 9650 Fixed Window - Impact Extruded Vinyl Direct Glazed "Impact" Fixed Window with Rated - HVHZ Flange (O configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15054 R4 II INST 15054.18.udf Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15054.18 for Design Pressure Ratings, any FLIS054 R4 AE EVAL 15054.18 udf additional use limitations, installation Instructions and Created by Independent Third Party: Yes product particulars. Back Neat Contac Us :: 2601 Blair Store Road. Tallahas�e FL 32399 Plane: 850-4B]-1824 The State of Florida Is an AA/EEO employe¢ Coovdaht 2(1 State of nodda.:: Pdvaw Statement :: Accessiblil N Statement :: Refund Statement Under Florida law, email addresses are public records. U you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida statutes, effective October 1, 2014 licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The email. provided may be used for official communication with the llcensee. However email addresses are pudic record. If you do not wish to supply a personal address, please provide the Department with an email address which an be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dirk he. . product Approval Accepts: hftps:llloridabuilding.uglpr/pr_app_ol.wpx?param=wGEVXQwtDq S73Fr2ZyiPl8Ew9YUwBR2BMUZO%2fzDBickxATMk)BrJA"/o3d%3d 4/5 \aienMNew SOuM YAndoos PERMANENT�R itla PMdoOAPP.l$VL-15054FI.NC-Omwim VL15054 I] DI<I�.150511]-18.6m,FL-1EM18 O 21 s T ap cp ro .m 03 �0 9n o'� S nm m-3 3 0 m ^i S2 g ox_ 0 0 z O -,. Z Z �C n g3W=6 � a m, mP_ 0 m3 3 0� >m p0 a2*5 a 3m 1 UC vm n Dz 0T ms 2m.o m �eii $ cm ymr3a o�mm' 0 ro p06 ° � mm' mon< /ice( 00 m as O N ggg On ' a C '� Q C a o. �• go -o E CL Ey xy E5.1"MAX.OVEAALLflN H9GHT—�{ !.: F W MAX FRAME HEIGHT S gg0 K x �SD $ 0 gSOL V W + jjl� O L` O �y�� S ft i, I, �"`AO ••• Q PROM" oaevneM. PnpaM .� t �'•/!�vtry9'/w�'a•:' f i NEW SOUTH 4] do F. 5.1,-W P.E Ne. 13409 N $ iIp Z GDBUILDING CONSULTANTS. INC.YY m PART OR ASSEMBLY: m TYPICAL ELEVATION, DESIGN PRESSURES & GENERAL NOMIFEWE P.O. Box 230. Valdoo. FL 33595 Phone No.: 813919] 9. .8 9. cA N .559. 1j NO DATE BY REVISIONS O SC)I S Y.W. BuiuY�xo Caxeuuisu'e Ixe. J SwM WMa+I MAMu+F.MWutll woAst�pPiwJA1L-lSRN FlwtlK-M-*qA -L OnOIYL.1& 17-1&492-: NJ• w NN N� m a • a <. 4 � N ° Nw T N R� � N � N N x • � a'. s � N � 2-A N N N N \\\\1111111/lll j holt r� PIIOCVCf. Pwr.r % o `.s 3 4 P.L ft. 4340 1V Y 2 N 'I�I111111111\\\\\, Q O1 PARE R��M w BUIL CgOULTANT0. INC. w HORI7WAL y�1 PA 0" 230. Va01m. il- S3lGO !b CRM SECTIONS PNaM Ne.: GMS 41" IwPf CA Na 9R1S wt s w.w. wwwmw mnw�iwrww iwa �OMiw�VMwSaM wndon PBtlAANFM�T1oitl�waEitl AppwW�L'1503wiNwd�C-Oawi^9�FL-ISOH(MUNI '3305 LMOAMS3.3 W, I NEW SOUTH P. BMnMtlt �. B B rutP.0. Bow ANCHORING ^Ne Oao�a w.w.• Na43M .j D U1.MNM.SWNNMEPn RM4W0lNb�IN gyy.y/apwlM'15D11Rffi\C- omwkVM-L 1]IIN(IF1.1 11-18Ag1.1 f� N 9gg a it $$ e 11'MNL O.C.') LOL o it II'MNCO.Q_" n y,�-�-Iat L „\\\1\IIIIIIII/I/I 4 RROOUCf: NEW SWIM,/ J`,*,;� //Illlllll\\ \ Q i+n [ L -1 m PNR OR ASSfl19.n. (.� lOM1CWO COMIIlUNM NO. VI S S" a FRA11E ✓�.� P.O. 2m m. R J]OYO YaM adClpRa� Pnwu xo.. 81a 2W rss ow w. "13 �OYN4\NM 59uN WYMPM rrpp/iN@1rylptlr poAst epgpgb�R'1505� ihuP�C- p�igOjl'1505� pONPFt'I505� 1)-18085-1 4 Nw�a«G)r 3 ; a m Oflm>� v e. w°*s°Mnioa i m 8 ssoo m � PM w BILL OF MATUM S. COYPONEN75 s MAIDlO OETAKS I!IMDI q VY P.O. Bov vMm 1k rave u REVISIONS 8J � QIL �_ 3 ; a PROD C NEW sa1rN v e. w°*s°Mnioa i m C y m PM w BILL OF MATUM S. COYPONEN75 s MAIDlO OETAKS I!IMDI q VY P.O. Bov vMm 1k rave u REVISIONS E RW R W Building Consultants, Inc. Consulting and Engineering Services for the Building Industry B C P.O. Bos 230 Voldcu, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Cerlificare of Authorization Na. 9813 Product Sub Category Manufacturer Product Name Category AAMA/WDMAICSA101/I.S.2/A440-08 Architectural Testing, Inc. Shawn G. Collins, P.E. ATI D7687.04-401-44 ASTM El 886-05 / E1996-06 NewSouth Window Solutions 9650 Fixed Window ATI C9933.06-401-44 AAMANVDMA/CSA101/I.S.2/A440-08 4901 Oak Fair Blvd Impact Rated - HVHZ Windows Fixed Tampa, FL 33610 wl Flange 2. Dade County NOA Materials (513)264.0129 Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for NewSouth Window Solutions, based on Rule Chapter No. 61G20-3, Method 1A of the State of Florida Product Approval, Dept. of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product anchoring drawing has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). See the Certification Agency Certificate for sizes, specifications & ratings. 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ', this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. For 2x stud framing construction, anchoring of these unites shall be the samae as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL -15054.18 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL -15054.18 for size and design pressure limitations. Supporting Documents 1. Test Report No. Test Standard Testing Laboratory Signed by ATI C9901.03-401-44 AAMA/WDMAICSA101/I.S.2/A440-08 Architectural Testing, Inc. Shawn G. Collins, P.E. ATI D7687.04-401-44 ASTM El 886-05 / E1996-06 Architectural Testing, Inc. Shawn G. Collins, P.E. ATI C9933.06-401-44 AAMANVDMA/CSA101/I.S.2/A440-08 Architectural Testing, Inc. Shawn G. Collins, P.E. ATI C9933.05-401-18 TAS 201, 202, 203-94 Architectural Testing, Inc. Shawn G. Collins, P.E. 2. Dade County NOA Materials 14-0423.16 Saflex PVB Interlayer (Eastman Chemical Co.) 13-0129.27 DuPont SentryGlas Interlayer 3. Drawing No. Prepared by last;# Signed &Sealed by No. FL -15054.18 RW Building Consultants, Inc. (CA #9813)gi:.H fi,.;4jA Lyndon F. Schmidt, P.E. 4. Calculations Prepared by Signed & Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) ,�, n„ Lyndon F. Schmidt, P.E. Nc ^.„t & � 7 N • `a � STATE ::t• .'. O R t p �w Lyndon F. Schmidt, P.E. FL PENo. 43409 -0�9� /1612015 Sheen of 1 Ali 181161110%