Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4 NOV117 2 1 2017 `n7 ` Business & Professional Regulation BY: ...................... tiraicma SCIS Home 1 Log In User Registration Hot Topics Subhpy Facts f Publications j FBC Staff C SCIS Site Map i Links Search i b' Product pro al dprJR USER:PubliL E Product Approval Menu>Application Detail FL# FL14610-R4 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext 4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Timothy J. Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers,FL 33913 (800)432-2204 Ext 4314 thoard@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 AAMA/WDMA/CSA 101/I.S.2/A440 2011 ANSI/AAMA/NWWDA 101/I.S.2 1997 ASTM E1886 2005 ASTM E1996 2005 ASTM E1996 2009 TAS 201 1994 TAS 202 1994 TAS 202 1994 Equivalence of Product Standards Certified By https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7V 90... 11/20/2017 Florida Building Code Online Page 2 of 4 Product Approval Method Method 1 Option A Date Submitted 04/22/2016 Date Validated 01/30/2017 Date Pending FBC Approval Date Approved 02/02/2017 7L# roducts Model,Number or Name Description 143 Vinyl Impact HR(Horizontal 143 Vinyl Impact HR(Horizontal Sliding Window) Sliding Window) Certification Agency Certificate Appfove"&use in HVHZ:No FL14610 R4 C CAC NI013349.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2017 Design Pressure: +50.0/-50.0 Installation Instructions Other: Maximum Size Flange 74"x 63"Tip to Tip&Fin 73" FL14610 R4 II 08-02869.1)df x 62" Buck/Box.Approved as XO,OX. Frame material to be Verified By: Luis R. Lomas,P.E. 62514 rigid PVC from Deceuninck North America AAMA Certified Created by Independent Third Party: Yes (DEP-1) Evaluation Reports FL14610 R4 AE 513680.odf Created by Independent Third Party: Yes 14610.2 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14610 R4 C CAC NI006178.02-R3.odf Approved for use outside HVHZ:Yes FL14610 R4 C CAC NI006178.04-R2.odf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure: +45.0/-45.0 06/30/2020 Other: Maximum Size 53"x 51",OX or XO Installation Instructions FL14610 R4 II 08-02698A.oddf Verified By: Luis R. Lomas,P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14610 R4 AE 513477A.Ddf Created by Independent Third Party: Yes 14610.3 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14610 R4 C CAC NI009471.01-R2-sianed.odf Approved for use outside HVHZ:Yes FL14610 R4 C CAC NI009471.03-Rl-signed.pdf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure: +35/-35 04/30/2020 Other: Maximum Size 112"x 63",XOX Installation Instructions FL14610 R4 II 08-02692.odf Verified By: Luis R. Lomas,P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14610 R4 AE 513467 .odf Created by Independent Third Party: Yes 14610.4 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL14610 R4 C CAC NI006178.01-R2-sianed.odf Approved for use outside HVHZ:Yes FL14610 R4 C CAC NI006178.03-Rl-sianed.odf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: N/A 06/30/2020 Other: Maximum Size 74"x 63",OX or XO Installation Instructions FL14610 R4 II 08-02693.odf Verified By: Luis R. Lomas,P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14610 R4 AE 513468.odf Created by Independent Third Party: Yes 14610.5 Series"FWI 1000"Aluminum Series"FWI 1000"Aluminum Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14610 R4 C CAC NI010658.01-R1-sioned.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7V90... 11/20/2017 REVISIONS REV DESCRIPTION DATE APPROVED A REVISED PER NEW TESTING 02/23/15 R.L. NOTES: 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE REQUIREMENTS OF THE FLORIDA BUILDING CODE. DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 17. ALL FASTENERS TO BE CORROSION RESISTANT. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 1/8" THICK MINIMUM MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 19. APPROVED CONFIGURATIONS: X0, OX. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED 20.UNITS MAY BE INSTALLED WITH OR WITHOUT FLANGE. COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE Of SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:02/24/2015 w E�ISt�/'I1 AAAAIOf1�66A�ALsysrea \ 51111111//// TABLE OF CONTENTS SERIES 4241 HR PVC HORIZONTAL SLIDING WINDOW _*• 0 6 *� 71 1/2" x 59 1/2" SHEET NO. DESCRIPTION �` ST'ATE OF •�` NOTES 1 NOTES DRAWN DWC No REV �'�• cIt P•• 2 ELEVATION TJH 08-00937 A ���`S'S• �G��`� 3 — 5 INSTALLATION DETAILS SCALE NTS I DATE 01/29/10 sNEET1 OF 5 RIF 71 1/2" MAX. FRAME WIDTH REVISIONS REV DESCRIPTION DATE APPROVED A REVISED PER NEW TESTING 02/23/15 R.L. r6MAX. . 11 3/4" MAX. O.C. 6" MA 3/4"1/8" ANN. .090" PVB BY SOLUTIA 1/8" ANN. 1/8" ANN. jEXTERIOR INTERIOR 59 1/2" 5/8" GLASS MAX. BITE FRAME XO HEIGHT ❑ ❑ SIKAFLEX 552 w GLAZING COMPOUND GLAZING DETAIL NOTES: 6' MA 1. MAXIMUM SASH SIZE: 35" X 56" 2. MAXIMUM D.L.O.: 32 1/2" X 54 1/2" 3. (8) 3/8" x 3/16" WEEP SLOT 3" FROM EACH CORNER AT BOTTOM RAIL AND GLAZING POCKET SERIES 4241 HORIZONTAL ROLLER PVC HORIZONTAL 4. (2) 1" X 3/16" WEEP SLOT AT EACH END OF SILL INTERMEDIATE LEG SLIDING WINDOW 5. (2) 3/8" X 1/8" WEEP SLOT 3 1/2" FORM EACH CORNER OF EXTERIOR SILL TRACK 6. (4) 1" X 1/8" WEEP SLOT 3" FROM EACH CORNER OF EXTERIOR SILL TRACK EXTERIOR VIEW 7. (2) 1 1/4" X 1/4" WEEP SLOT W/FLAP 3" FROM EACH CORNER OF EXTERIOR SILL FACE. DPRESSURE RATING IMPACT RATING t50PS LARGE AND SMA L5�OPSL ISSYLfiMPAZ`T SIGNED:02/24/2015 Eastern HARDWARE SCHEDULE «�+ =w•� t1 i 'GEN 9 �� A. (2)METAL CAM LOCK AT 7"FROM EACH END OF LOCK STILE `�."�\ SF,LT B. (2)METAL ROLLER AT EACH END OF BOTTOM RAIL SERIES 4241 HR PVC HORIZONTAL SLIDING WINDOW *• 0 95Y *� 71 1/2" x 59 1/2" %�` C. ALUMINUM REINFORCEMENT 10300084 AT FIXED MEETING STILE =.0 D. ALUMINUM REINFORCEMENT 10300082 AT LOCK STILE,TOP AND BOTTOM RAIL ELEVATION p0•• TAT OF. E. ALUMINUM REINFORCEMENT(10300207)ATIAMBSTILE DRAWN: DWI;NO- 37 �fOR10P'G��\�� SCALE ��TJH 08SOOE937 A 7s/ONALIE?���\ NTS 01/29/10 2 OF 5 1/2" MIN. REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED WOOD FRAMING A REVISED PER NEW TESTING 02/23/15 R.L. OR 2X BUCK BY OTHERS1 3/8" MIN.<r EMBEDMENT 1 3/8" MIN. BACKER ROD 1/4" MAX. EMBEDMENT & APPROVED SHIM SPACE 1/4" MAX SEALANT O SHIM SPACE a a 0 0 #10 WOOD SCREW 0 INTERIOR 1/2" MIN. Do EDGE DISTANCE o #10 WOOD SCREW INTERIOR p WOOD FRAMING AC� D EXTERIOR OR 2X BUCK BY OTHERS EXTERIOR BACKER R00 & APPROVED SEALANT a #10 WOOD JAMB INSTALLATION DETAIL t3 O WOOD FRAMING OR 2X BUCK INSTALLATION BACKER ROD SCREW & APPROVED 1/4" MAX. SEALANT Q SHIM SPACE WOOD FRAMING �7 OR 2X BUCK 1 3/8" MIN. BY OTHERS EMBEDMENT 1/2" MIN SIGNED:02/24/2015 EDGE DISTANCE E/3TERN MCHRECiIIRK�� TICAL SS SECTION WOOD FRAMING OR2XOBUCK 1MSTALLATION Eastern `\\\J\5 R I to 4f ,......_,..."_.....a"".. ` = .as,n ` •�G ENS' J+ 'w F' NOTES: SERIES 4241 HR PVC HORIZONTAL SLIDING WINDOW *.• `•'0 ( *' 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, 71 1/2" x 59 1/2" �� NOT SHOWN FOR CLARITY. INSTALLATION DETAILS p• $$TAT OF 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE :: DESIGNED IN ACCORDANCEWITHASTME2112 DRAWN. DwcNo. REV SCALE DATE TJ08 500937 A s/ONALI�N��`� NTS 01/29/10 3 OF 5 REVISIONS 3/4" MIN REV DESCRIPTION DATE APPROVED EDGE DISTANCE A REVISED PER NEW TESTING 02/23/15 R.L. 1/4" MAX. METAL SHIM SPACE STRUCTURE BY OTHERS APPROVED O SEALANT 0 1/4" MAX. a SHIM SPACE a ❑ F3 INTERIOR 0 #10 SMS OR 3/4" MIN o 0 SELF DRILLING EDGE DISTANCE SCREW --- #10 SMS OR SELF DRILLING SCREW EXTERIOR INTERIOR D METAL BACKER ROD EXTERIOR STRUCTURE & APPROVED BY OTHERS SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION a #10 SMS OR SELF DRILLING SCREW BACKER ROD & APPROVED SEALANT Q 1/4" MAX. SHIM SPACE METAL STRUCTURE BY OTHERS 3/4" MIN. EDGE DISTANCE SIGNED:02/24/2015 VERTICAL CROSS SECTION EA4TERN AnwrtEcnnu 3Y3TENe \\\ METAL STRUCTURE INSTALLATION � � Eastern °:��. �����it- `p n -DOMESTIC AVE \\_\� • 4f/' FOgT NYER3.r�sw,x `r,•��O ENSF,S _. .._.._"e.... n„ _ NOTES: SERIES 4241 HR PVC HORIZONTAL SLIDING WINDOW =*• 0125*� 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, 71 1/2" x 59 1/2� �AT(ATc� OF NOT SHOWN FOR CLARITY INSTALLATION DETAILS w 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DRAWN 11-NO. RFV i�'�••'c[ 0 \� DESIGNED IN ACCORDANCE WITH ASTM E2112 /�tS sJH cALE DATE 08-00937 A ///�s�pIVALL�?���\ NTS 01 29 10 S4 OF 5 2 1/2" MIN. RMSIDNS EDGE DISTANCE REY DESCRiPnON G�iE APPRaJED CONCRETE/MASONRY A REVISED PER NEW TESTING 02/23/15 R.L. BY OTHERS °• a < ° a 1 1/4" MIN. OPTIONAL 1X BUCK ° '° °d EMBEDMENT SEE NOTES 3 — 7 SHEET 1 CONCRETE/MASONRY BY OTHERS ' BACKER ROD & APPROVED 1/4" MAX. OPTIONAL 1X BUCK a 1/4" MAX. SEALANT SHIM SPACE SEE NOTES 3 — 7 •' SHIM SPACE B SHEET 1 00a3/16" TAPCON ' INTERIOR Q0 3/16" TAPCON ° � o • EXTERIOR INTERIOR 2 1/2" MIN. C3 EDGE DISTANCE v D EXTERIOR BACKER ROD & APPROVED 1 1/4" MIN. SEALANT EMBEDMENT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION BACKER ROD 3/16" TAPCON & APPROVED SEALANT /4" MAX. NOTES: OPTIONAL 1X BUCK a r 1 SHIM SPACE SEE NOTE 3 — 7 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SHEET 1 NOT SHOWN FOR CLARITY 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 CONCRETE/MASONRY ° SIGNED:02/24/2015 BYMS a 1 1/4" MIN. pE`u 'sea \111111//1 G• ° ° EMBEDMENT Eastern E,�TE.,,�TK . \9 R• LO�1 G /w 16111 pOMESTIG AVE \\ 4fFL 2 1/2" MIN. SERIES 4241 HR PVC HORIZONTAL SLIDING WINDOW *• 0y612b 71 1 LLA x 59 TAIL EDGE DISTANCE INSTALLATION DETAILS p• TAT OF VERTICAL CROSS SECTION LDRAWN owc No. RFV i0.• ••jO[ P•• '� CONCRETEAIIASONRYINSTALLATION /RFs.•ORVD HonrE 08-00937 A s�ONAL1�?���\ NTS 01/29/10 5 OF 5