Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 1 cr Professional Regulation SCIS Home l.op In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER:Public User Product Aoorovai Menu>Product or Aoolication Search>Application NOV 2 ?, 10� Search Criteria BY: Refine Search Code Version 2014 FL# 22513.8 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications FL# Type I Manufacturer Validated By $Aatus FL22513 New Masonite International National Accreditation& Approved FL#:FL22513.8 Management Institute Model:Wood-edge Steel Side-Hinged Door Unit (804)684-5124 Description:6'-8"3/4-Lite Glazed I/S or O/S Single or Double Door w/or w/o Sidelites Category:Exterior Doors Subcategory:Swinging Exterior Door Assemblies *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road Tallahassee FI a, 399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_. Product Approval Accepts: MON " FRE Credit Card safe https:Hfloridabuilding.org/pr/pr_app_lst.aspx 11/22/2017 Florida Building Code Online Page 1 of 3 Willi i o SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search db" Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail ®, FL# FL22513-RO Application Type New Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800)663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/13/2017 Date Validated 06/16/2017 Date Pending FBC Approval Date Approved 06/20/2017 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEO... 11/22/2017 Florida Building Code Online Page 2 of 3 Date Revised 11/21/2017 Summary of Products FL# Model,Number or Name Description 22513.1 HPC Wood-edge Steel Side-Hinged 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 RO C CAC N101 374i.01.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 RO II FL0212.odf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6-8"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 RO AE 514008.ndf system is required. Door top rails stamped"HPC".See DWG- Created by Independent Third Party: Yes MA-FL0212 for details. 22513.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S or O/S Single Door Unit Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 ROC CAC N1013747.04.udf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 RO II FL0215 odf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 3'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 RO AE 514009.odf system not required.See DWG-MA-FL0215 for details. Created by Independent Third Party: Yes 22513.3 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate if Approved for use in HVHZ:Yes FL22513 01374.1 Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +45/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 RO II FI Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 RO AE 514007.odf system not required on opaque panels,but is required on Created by Independent Third Party: Yes glazed sidelites. See DWG-MA-FL0215 for details. 22513.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque O/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 RO C CAC V 3747.04.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant,Yes 06/30/2021 Design Pressure: +50/-45 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 RO lI 1 Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 RO AE 514007.odf system not required on opaque panels,but is required on Created by Independent Third Party: Yes glazed sidelites.See DWG-MA-FL0215 for details. 22513.5 Wood-edge Steel Side-Hinged Door 8'-0"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 RO C CAC N1013747.06.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +40/-40 Installation Instructions Other:Evaluated for use in locations adhering to the FL22513 RO 11 FL0217.udf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 8'-0"max nominal size. Evaluation Reports When impact resistance is required, hurricane protective FL22513 RO AE 514007.udf system is required. See DWG-MA-FL0217 for details. Created by Independent Third Party: Yes https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEO... 11/22/2017 Florida Building Code Online Page 3 of 3 22513.6 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single Door Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 RO C CAC N1013747a0, Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +70/-70 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 RO II FL0211.Ddf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed.3'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 RO AE 514010.odf system not required.See DWG-MA-FL0211 for details. Created by Independent Third Party:Yes 22513.7 Wood edge Steel Side-Hinged Door 6'-8"Opaque I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22513 RO C CAC NI01 747.df Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2021 Design Pressure: +55/-55 Installation Instructions Other:Evaluated for use in locations adhering to the FL22513 RO II FL0211.Ddf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 RO AE 514008.Ddf system not required on opaque panels,but is required on Created by Independent Third Party: Yes glazed sidelites.See DWG-MA-FL0211 for details. 22513.8 Wood-edge Steel Side-Hinged Door 6'-8"3/4-Lite Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL22513 RO C CAC NI013747 03 Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other: Evaluated for use in locations adhering to the FL22513 Rn H FL0214.pdf Florida Building Code,including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements do not exceed the Created by Independent Third Party: design pressures listed. 12'-0"x 6'-8"max nominal size. Evaluation Reports When impact resistance is required,hurricane protective FL22513 RO AE 5140fi p f system is required. See DWG-MA-FL0214 for details. Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. ' Product Appro�val Accepts: No r Credit Card ,Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46QEO... 11/22/2017 NOTICE OF PRODUCT CERTIFICATION h « Company: Masonite International Corporation Certification No.: NI013747.03 1955 Powis Road Certification Date: 06/08/2017 West Chicago, IL 60185 Expiration Date: 06/30/2021 Product: Wood-Edge Steel 3/4-Lite or Less Glazed Inswing or Outswing Door w/Full-Lite or Less Non-Impact Rated Sidelites(w/Wood Frame unless noted) Specification: TAS 202-94/ASTM E330-02 Glazing: Insulating Glass(Tempered) The"Notice of Product Certification"is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listin at www.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute(ANSI). Inswing Glazed Structural Water Test Report Number Configuration or or Maximum Design Test Drawing Number& Outswin Opaque Size Pressure Pressure Comments X I/S Glazed 3'0"x 6'8" +50/-50 0.0 psf NCTL-110-19469-1 Single 3/4-Lite Max Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-FL.0214-17 X O/S Glazed 3'0"x 6'8" +50/-50 3.0 psf' NCTL-110-19469-1 Single 3/4-Lite Max 4.5 psfMaximum Panel Size:3'0"x 6'8" 7.50psf' Anchor Details-DWG-MA-FL0214-17 XX I/S Glazed 6'0"x 6'8" +50/-50 0 psf NCTL-110-19469-1 Double 3/4-Lite Max Maximum Panel Size:3'0"x 6'8" Anchor Details-DWG-MA-FL0214-17 XX O/S Glazed 6'0"x 6'8" +50/-50 3.0 psf NCTL-110-19469-1 Double 3/4-Lite Max 4.5 psf' Maximum Panel Size:3'0"x 6'8" 7.50psf' Anchor Details-DWG-MA-FL0214-17 XO/OX I/S Glazed 6'0"x 6'8" +50/-50 0 psf NCTL-110-19469-1 Single w/Sidelite 3/4-Lite Max Door Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FL0214-17 XO/OX O/S Glazed 6'0"x 6'8" +50/-50 3.0 pst' NCTL-110-19469-1 Single w/Sidelite 3/4-Lite Max Door 4.5 psf' Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Full-Lite Max S/L 7.50psf' Anchor Details-DWG-MA-FL0214-17 OXO I/S Glazed 9'0"x 6'8" =50/-50 0 psf NCTL-I 10-19469-1 Single w/Sidelites 3/4-Lite Max Door Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Full-Lite Max S/L Anchor Details-DWG-MA-FL0214-17 OXO O/S Glazed 9'0"x 6'8" X50/-50 3.0 psf' NCTL-110-19469-1 Single w/Sidelites 3/4-Lite Max Door 4.5 psf' Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Full-Lite Max S/L 7.50psf' Anchor Details-DWG-MA-FL0214-17 OXXO I/S Glazed 12'4"x 6'8" +50/-50 0 psf NCTL-110-19469-1 Double w/Sidelites 3/4-Lite Max Door Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6.8" Full-Lite Max S/L Anchor Details-DWG-MA-FL0214-17 OXXO O/S Glazed 12'4"x 6'8" X50/-50 3.0 psf' 110-10-19469-1 Double w/Sidelites 3/4-Lite Max Door 4.5 psf' Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Full-Lite Max.S/L 7.50 sf' Anchor Details-DWG-MA-FL0214-17 1-Denotes Bumper Outswing Threshold 2-Denotes USeries Outswing Threshold 3-tli-Dam Outswing Threshold National Accreditation& Management Institute,Inc./4794 George Washington Memorial Highway/Hayes,VA 23072 Tel:(804)684-5124/Fax: (804)684-5122 NAMI AUTHORIZED SIGNATURE: �1 A 00 u7 11 1 1 MASONITC. 149"MAX. OVERALL FRAME MOTH � - p0 27" MAX 36.375" MAX. 21" MAXQ 3/4-LITE WOOD-EDGE STEEL DOOR UNIT D.L.O. PANEL WIDTH D.L.0_ 37.5" MAX. Q Q FB'-B"DOUBLE DOOR WITH/WITHOUT SIDELITES W/ASTRAGAL FRAME WIDTH J O GENERAL NOTES ac w O 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO ~ C U THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM ? _ DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, W 117() DOES NOT EXCEED THE DESIGN PRESSURES LISTED. X �' 2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), '0 HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. U7 LLJ 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION. 0 v m '-3 HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. m 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING: o_ TEST DESCRIPTION DESIGNATION LITE FRAME_ '3 SELF IGNITION TEMP 1ASTM D7929 B42 'F > 650 'F g�W RATE OF BURNING A11 STM 5635 1.28 IN MIN ILx^1 SMOKE DENSITY ASTM 52843 70.270 ro TENSILE STRENGTH- ASTM D638 1.8% DIFF COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 0 0 DOUBLE DOOR UNIT W,/SIDELITES a a Adderdw to NAM } Ge(Mralvn No.-AM2/17#7 m Reviewed Br DateRevieve V) z 0 (_N 1111 1111 1111 1111 ®® 11® 11 1 11 ,111 11® 11 ui p SINGLE DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT WISIDELITES DOUBLE DOOR UNIT W/SIDELITES WITH SIDELIIE WITH SIDELITE 0 Z WHERE WATER INFILTRATION PERFORMANCE IS u�te: 5 26 11 TABLE OF CONTENTS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE SHEET # DESCRIPTION CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S HIGH DAM 0 S ./.. ,/ SCALE: N.T.S. X 37.5-_ +50.0 -50.0 +50.0 -50.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 oma_�, SWS 1 TYPICAL ELEVATIONS & GENERAL NOTES XX 74 +50.0 -50.0 +50.0 -50.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 2 ANCHORING LOCATIONS & DETAILS OX or XO 75 +50.0 -50.0 +50.0 -50.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 - O. " �` 3 ANCHORING LOCATIONS & DETAILS XO 112.5 +50.0 -50.0 +50.0 4 -50.0 N A +20.0 -20.0 +30.0 4 -30.0 +50.0 -50.0 KURT BALTHAZOR DRAWING N0: OXXO 149 +50.0 -50.0 +50.0 -50.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 FLORIDA P.E. 156533 DWG-MA-FLO214-17 SHEET 1 or 3 CL Do 0 6" SEE DETAIL 3.. 6"4� �CO E' Q O 3. I 3' I 3"-{ - 3" 3" 3" j (�J I I I i 6" 6'� 6" 6'--13•� [1-- I —�6" 6" o o 0 �U • M — N n < a SEE DETAIL tai) W J J Q Q ;-T SEE DETAIL oSEE DETAIL .G. - Oq --- - W W - - "C" •_ Q K Q N • Pu A M O Q a G G H M H o 6" 6" 3" g�� m 6" 6" N z� I I I r � I I I I m U 3. m oma 3'-� 3. 3" 3' 3" 3" 6' 6" al a 6" SEE DETAIL 6 .F. #8 x 2" m ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH #8 x 2" #10 x 5/8" THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH #10 x 5/8' FOR A 1.375" THROW #8 x 2 #10 x 1" DETAIL "E" ASTRAGAL DETAIL "F" ASTRAGAL Z 0 � #10 x 2-112" ATTACH ASTRAGAL RETAINER BOLT � #10 x 1" STRIKE PLATE TO FRAME #10 x 5/8" AS SHOWN. DETAIL "C" DETAIL "D" w a 0.9621 HOT MEET p ELASTOMER�� 1.375" f /6 X 1-1/2-PHS T T Adderdum to NAW Z:.` o INSWING THRESHOLD BUMPER O/S THRESHOLD HOT MEET • vz BITE ELASTOMER GeOdFAKANo.: o1' v Z � ":x„••ti^ ReAawed By: DATE: 5126117 -` SCALE N.T.S. 1.482' 1.75' 1.047 12i£8145 ��� TYPICAL GLAZING DETAIL DWG.BY: SINS T T NON-IMPACT GLASS CHK.er: DRAWING NO.: Z—SERIES 0/S THRESHOLD HIGH DAM O/S THRESHOLD OWG-MA-FLO214-17 SHEEP 2 of 3 SEE DETAIL3• 6` —{ 6" 0 Q 00 "E" SHT. 2 —{ _L 3" 6" 3 36 3" 3+ O 6" 6' 6" I I I I 16" 6" QNO cc 3QLL O M^ W f Q Z CL T a SEE DETAIL a I_W— Ln U }"D' SHT. 2 — — Ln z J J Ld SEE DETAIL o o " C' SHT. 2 A w — — w o n B A M A v G i 4 6` I i I I I i I I I I I co �o I I g' N z 3" 3' 3 3""1 h—3" .6 6' 3. v SEE DETAIL 6. 6" �I o "F" SHT. 2 6- HARDWARE SCHEDULE a 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND m SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. ATTACHMENT DETAIL 1.25 >, f 2. 4" X 4" FULL MORTISE BUTT HINGES. 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, MIN _025" MAX 1"X1/2' CORRUGATED #10X2" WOOD SCREW SIGNED AND SEALED BY ROBERTO LOAAS, PE SHIM 3" FROM EACH END 6" FROM EACH END N (FLORIDA #62514) WITH THE LOWEST (LEAST) AND 7" OC AND 12" OC o FASTENER RATING FROM THE DIFFERENT FASTENERS CL BEING CONSIDERED FOR USE. JAMB, HEAD, AND ACRYLIC LATEX #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE TYPICAL MASONRY ACRYLIC CAULK SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR ANCHOR INSTALLATION CAULK CL LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". o WOOD SCREW EDGE DISTANCE MIN 3/4". COMBINATION WOOD COMBINATION WOOD • MULLION BOXED MULLION BOXED 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM 1MSN � (BOXED) (BOXED) ANSI AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT _0.25" OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MAX �3�o6D SCREWS" z MINIMUM EMBEDMENT OF 1-1/4 EACH END CL—I �— AddendrtoNAM wTE: 5125117 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO 1 f' • Ce dcalpnNo.: 011 Y _ SMI: N.T.S. TRANSFER LOADS TO STRUCTURE. Rev awed 6y: owc.er: SINS Data 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. TYPICAL WOOD BUCK cw.ffy: ANCHOR INSTALLATION o"""A"c NO INTEGRAL WOOD DWG-MA-FLO214-17 MULLION (CHS) smm 3 ov 3 L. Roberto Lomas P.E. 1432 Woodford Rd Manufacturer: Masonite Lewisville,NC 27023 Report#: 514008 434-688-0609 Date: 05/01/2017 rllomasicvirlomaspe com Test Report: N/A Product: Double Door with and Without sidelites 12'x6'8"(wood frame) scope: This analysis provides calculations,quantities,and spacing requirements for installing product to substrate,and it applies only to the product described herein.These calculations comply With requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/6 w/out gap: a. With threads present in shear plane Fastener type:#10 wood screw (NDS 2012,TR12) Nominal diameter: D: 0.190 in Gap: g'. 0.0000 in Root diameter: or: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p'. 1.140 in Screw bending yield strength: F„y: 80,000 psi Side member: Douglas Fir-Larch(6=0.50) Main member: Spruce-Pine-Fir(6:0.42) Side member thickness: 1,= 1.000 in Main member thickness: tm 1.500 in Side member dowel bearing strength: FW= 4,650 psi Main member dowel bearing strength: F,m= 3,350 psi Side member dowel bearing length: I,= 1.000 in Main member dowel bearing length: 1T= 1.140 in Mode I, Mode I, Mode II Mode III,• Mode III, Mode IV qm= 636.5 lbs/in qs= 884 lbs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.0014 P= 725.61 lbs P= 884 lbs B: 1.07 B: 0.57 8: 0.5 B: 0.000 Kp= 2.400 Ko= 2.400 C: -427.67 C: -253.62 C: -267.7 C: -93.6 Z.= 302 lbs Z.= 368 lbs P= 331 lbs Ms= 46.8 in-lbs Mm: 46.8 in-lbs Ko= 2.400 P= 297 lbs P= 319 lbs P= 263 lbs Min.Design value: Z= 110 lbs Z= 138 lbs K�= 2.400 Ko= 2.400 Ko° 2-400 Duration Factor: Cp= 1.6 Z= 124 lbs Z= 133 lbs Z= 110 lbs Allowable Design Value(ZCo): Z'= 175 lbs/anchor Solid members w/4 w/out gap: a. With threads present in shear plane Fastener type:#10 wood screw (NDS 2012,TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb= 80,000 psi Side member: Douglas Fir-Larch(6=0.50) Main member: Steel strap/clip Side member thickness: t,= 1.000 in Main member thickness: t„= 0.048 in Side member dowel bearing strength: F�= 4,650 psi Main member dowel bearing strength: F,,,= 61,850 psi Side member dowel bearing length: I,= 1.000 in Main member dowel bearing length: 1„= 1.140 in Mode I,• Mode I, Mode II Mode IIIm Mode III, Mode IV qm= 11752 lbs/in qs= 884 lbs/in A: 0.0003 A: 0.00059 A: 0.00033 A: 0.0006 P= 13397 lbs P= 884 lbs B: 1.07 8: 0.57 B: 0.5 8: 0.000 KD= 2.400 Kp= 2.400 C: -4038.9 C: -3864.9 C: -267.7 C: -93.6 Z„= 5582 lbs Z.= 368 lbs P= 2287 lbs Ms= 46.8 in-lbs Min= 46.8 in-lbs Kt,= 2.400 P= 2126 lbs P= 420 lbs P= 392 lbs Min.Design value: Z= 163 lbs Z= 953 lbs Ko= 2.400 KD= 2.400 Ko= 2.400 Duration Factor: Cp= 1.6 Z= 886 lbs Z= 175 lbs Z= 163 lbs Allowable Design Value(ZCo): Z'= 262 lbs/anchor Fastener type: 1/4"ITW Topcon N.O.A.16-1222.06 Substrate: Hollow block Minimum embedment: 1.25 in Edge distance: 4.00 in Tabulated shear design value: Z= 202 lbs Edge distance: 2.00 in Tabulated shear design value: Z= 161 lbs Actual edge distance: 2.50 in Reduction factor: 0.85 ```\` Spacing: 4.00 in Tabulated shear design value: Z = 202 lbs \�` R . L o Spacing: 2.00 in Tabulated shear design value: Z= 164 lbs �� • V q Actual spacing: 3.00 in Reduction factor: 0.91 `•\rj E N ly Allowable Design Value(Zf, ): Z"= 155 lbs/anchor _�y • r Minimum anchor capacity: 155 lbs/anchor 061 • '� • • Note:Anchors with the least capacity is used for calculations to quality anchors with higher capacity. ~� ` • TAT OF ; j �p'�••;c�ORIOP• 11(il Luis R. Lomas P.E. FL No.: 62514 1 of 3 5/2/2017 L. Roberto Lomas P.E. 1432WoodrordRd. Manufacturer: Masonite Lewisville,NC 27023 Report k 514008 434-688-0609 Date: 05/01/2017 rllornas(cDlrlornaspe corn Anchor calculations minimum required anchors 36.38 36.38 Design pressure: 60.0 psf Max. Anchor Al Al � Area Load Ind. Zone O.C. Cap. Load Result nzyynz 79.25 (ft') (lbs) (in) (in) (lbs) Qty (lbs) Al Al Ar 2.3 138 N/A N/A 155 1 138 OK Az 1 7.7 463 6.00 21.00 155 5 93 OK 72.75 A3 7.7 463 N/A N/A 155 3 154 OK 37.50 36.38 36.38 37.50 Design pressure: 60.0 psf Max. Anchor At Aa j/� Al � Zone Area Load Ind. Cap.p. Load Result Y / Y Y (ft) (lbs) (in) (in) (lbs) `qty (lbs) A2 79.25 A, 2.4 146 N/A N/A 155 1 146 OK At M At AZ7.9 473 6.00 21.00 155 5 95 OK A3 7.8 468 N/A N/A 155 4 117 OK 147.75Aa 2.3 138 N/A N/A 155 1 138 OK AS 7.7 463 N/A N/A 155 3 154 OK Anchor Locations: Double door -36.38-- -- - 36.38 - - 6.00 TYP. 6.00 TYP.� 18.19 TYP. 3.00 TYP. T_ 61_ 13.45 MAX.I O.C. 79.25 L 0 � \C, 6.00 •�'��% 6.00 =*' 0 5 •*= TATOF ;,Qj� /ONAL�ti?��� lith Luis R. Lomas P.E. FL No.: 62514 2 of 3 5/2/2017 L. Roberto Lomas P.E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514008 434-688-0609 Date: 05/01/2017 rllomas(c)Irlomaspe.com Double door with sidelites 37.50 36.38 36.38 37.50 18.75 TYP. 6.00 TYP. — 6.00 TYP. 18.19 TYP. 3.00 TYP.. 1 I 6.00 1 13.45 MAX.O.C. I 79.25 6.00 Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE#10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16"TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE#10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2"MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:I //� B.CONCRETEI MINIMUM SPECIFIC GRAVITY NIMUM COMP ESSE OF OF 2,000 PSI. ��`\��� R O"' j C.MASONRY:HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. ti V `�\G E %9 (P 'rte D.METAL STRUCTURE:STEEL 18GA(.048")FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI ` • .052"THICK MINIMUM 051 • #- 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE '— DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. V t " �p , TAT OF 00 Luis R. Lomas P.E. FL No.: 62514 3 of 3 5/2/2017