Loading...
HomeMy WebLinkAboutOC Product aproval SLC t Business &Professional Regulation BETS Home 1, Lag In I User Registration ' Hat Toptcs Submit Surcharge Scats&Facts Publications FBC staff i BCIS Site Map Links Search Or 4 Product Approval USER:Pub1c User Pmdur[Apurcval Menu>Product or Application Search a Application L,,Si>Application Detail FL# FL10674-1112 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sa ncra nt@owensco rnig.corn Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert I.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R12 COI 2D16 01 COI Nieminen. ddf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 Summary of Products FL* Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R12 II 2Q15 04 FINAL _ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL1067+Ri2.adf Impact Resistant:N/A Verified By: Robert].M.Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section S. Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT SINGLES FL1Q674-R12.pdf Created by Independent Third Party:Yes $act Next Contact Us::2601 Blair Stone Road.Tallahassee&3Z399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::A5ccessibility Statement::Refund Statement Under Porida law,email addresses are public records..If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.most provide the Department with an email address if they have one,The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S„please click here. Product Approval Acemapts: F_ limid :. PmWW Credit Card Safe EXTERIOR RESEARCH &DESIGN,LLC. J` Certificate of Authorization#J9503 TRINITY : p 353 CHRISTIAN STREET, UNIT#13 Ef\© OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R7 One Owens Corning Parkway FL10674-1112 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: +��545.,trrrra.ri� The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. j t �J]L q 4`4 P.E.on04/lg/2016.This does not-as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 document.signed,sealed hardcopies bay bean transmitted�the Product Approval Administrator and to the named d ient CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.F.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY .ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7A,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 R. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Qua Iity Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic'and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles, 4.1.3 Devonshire'"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration', TruDeffnition® Duration', Duration' Premium Cool, TruDefinition* Duration' Designer Color Collection, TruDefinition'Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 CLdficare of Autherbratfnn#9503 FL10674-R12 Revision 7:04/18/2016 Page 2 of 8 TR.INFY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Va,d= 150 mph (V It= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (Vrdt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INsTALIATION: 6.2 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire'shingles require minimum five(5)nails per shingle. ➢ WeatherGuard'lip shingles require minimum six(6)nails per shingle. ➢ Devonshire"'shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus, wed Felt underlayment Deck F-ek unde�taym t Weathe!Loc _ weaslrerL¢drt ,. Sell adheredundedapmant WeatherLosk° underlayment Dr�P Drip edge edge adge ftka h k W Nails located T—r from me 2"3"from eave install first selhsealing adhesive Starter Str��r positioned along eave y,�fi $°� ` poanfwud aWnp Wve removed shingle stRth 6"removed Starter Starter Strip shingle overhangs eaves and rakes 1�,='i" Sauter Snip Pjus owrhars2seavas and rakes tra^-314^ Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Autharization#9503 F1.10674-1112 Revision 7:04/19/2016 Page 3 of 8 TRINITY ERa 6.2.6 Minimum Nailing—Classic"&Supreme: a � 7WsndAw*a* Normal Mansard or Area pare Mansard or Area paWind Anew High Wind dezvanas y High WindArea para vianros normales Areas vientaa fuerte+ s noFinalea Areas viamoa fwrtes 2- i- rS"Exposure n 6.2.7 Minimum Nailing--BerkshireO: Sealant strip Sealant strip La tira de segadar /La Lira de seflador +—...�._►a.+ . • (--r •a e ••----.f— a 0-0-0 8 v. r 1 1 Standard Fastening Pattern 6-Nail Fastening Pattern Sealant s1riip La tka de seliadar .41, ra ----------aa s- •e ra P 9 Yt" 8 Yf 8 Yt a Yt' 5" 1 1 1 T' AVMN motilgcement Caawto de tatha de astalta Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-RJ 2 Revision 7:04/18/2016 Page 4 of$ TRINITY ERD 6.2.8 Minimum Nailing—Devonshire'": '�..� ts..—]r �I 8" 8" • N �` Gsvos -- ____ Nails ........ 5-518"exposure Sealant location T Exposid6n de 5.5/8 puig T Ubicacv6n del sellador . Ten t"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern 'Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration Premium Cool &TruDefinition Duration Designer Color Collection: 4-Nail Fastening Pattem 6-Nall Fastening Pattern StasNanA txtenirrp area width SUVw�I®PastitNtp atra vridltt 1" 12" ..Y 4 I 7r '1'. 12 All El F� jj s-tra" 6AR^ b17B"531E" J F1 F� R Standard Fastening Pattern 6-Dail Fastening Pattern Fastening For Slopes Greater Than 21:12 s,rewa-,wt.t.%eo..rdth s 12 1r J SOW¢y{^ Pow 1"Spats of AlphO Rooang Ce t Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Certificate of Authorizotion#9503 FI-10674-1112 Revision 7:04/18/2016 Page 5 of 8 i TRINITY ERD 6.2.1. Minimum Nailing—Tru Definition'Oakridge®,Oakridge®: 4 Nail Pattern 9 Nail Pattern Esquamo con 4 ciavos Esquema con 6 davos 1, 1„ 1^ T i WW'Fxposure Naas 5519"Exposure 5518"EY ue Was SSff Exposure Erposteiende55/BPufE Cleves €upnsirrandeySiSputg p� filar r FxpasFoian de 5 5!8 paig. fipesicdin de!i.�/8 pzQg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 au..rw�r,r.+n�ma+wiam r Hsi NR�ce� f 72' #I! 12• ales•sue _ sar 1^saw arnaph+n IloaflAg c.m.m Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuar& HP: aline aft Vbvr FF � �7 .� Vi�ihs Viral .:,4"► ,•.•ass .:..,• rc bm Exterior Research and Design,LLC, Evaluation Report 037940.02.12-117 Cerrihcare ofAurhorization N9503 FL10674-1112 Revision 7:04/18/2016 Page 6 of 8 TRil�li'Y'ERQ 6_3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, WeatherGuard'HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of QuraRidgel Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Failing—Berkshire®Hip&Ridge and High Ridge: Fig.4 4 Pl Fig.2 f..-_ evaFnp ViMld Uiredba A Toplhew Side View Nds MAN 4 1 Top LaukOW 2� qqm I I I I I p I I k I I I ! I I 6"--►1 8' �I �imosure �I ul 1 I E E 6.3.4 Minimum Nailing—WeatherGuard'HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 4 TOPVIew E_..Prev�rtNl�wind '� 6Faactbn - `\ Nails-----------.-i, A 44 NOIIS Malls T' P 4 a' AA e ! I I ; 1 Y i v w Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-R12 Revision 7.04/18/2016 Page 7 of 8 TRINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard r-- .-3�•.-.--—. Wind Direction Fastening Sealant Strip Pattern ll g'Ecposure [� Seelwrt 1Z' 7l- t Fuiee 7'h` B'Irrpesure Cover Eripased Frra3a ' with Roof Cement 6.3.6 Minimum Nailing—DuraRidgel Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. rtsaf�ng'I15rd @k�etwi V ra rp:�4sn '�-6wrtf don du wow � Yscasgxirecx I .. tlertscft -woo trr*dCPT*"P! u_;i • � • Rxa¢rrs G§xriny Sur<clsr i., I } r I� I� slSti� L i i ,adbfi 12- f 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named Q4 entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization#9503 FL10674-1112 Revision 7:04/18/2016 Page 8 of 8