HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online
Page 1 of 2
a
ProfessionalRegulation
?,•,
BusinessSOS Home Log in User Registration Hot Topics Submit Surcharge Stats&Fads Publications FBC Staff MS Site Map Links Search
��
Professibnal cilProduct Approval
' USER:Public User
L a < "i
Product Approval Menu>Product or Application search �r
>AoohcaUon List>Application Detail �j
FL# FL16048-R1 NOV 2 7 L01t7
Application Type
Revision {'ER"f{?"Tf iNIG
Code Version 2010 St. Lucie Co
untv, r F�
Application Status Approved
Comments
Archived
f
Product Manufacturer
Address/Phone/EmailTRI-BUILT Roofing Produ ` Y
�ff '� "
9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.rulz@tribuiltmateriaisgroup.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterialsgroup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.raiz@tribuiltmateriaisgroup.com
Quality Assurance Representative
Address/Phone/Emall
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/24/2015
Validated By John W. Knezevlch, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 Rl COI Trinity ERD Cl Nieminen 2013 odf
Referenced Standard and Year(of Standard)
t d Year
ASTM D1970 2001
ASTM G155 2005
FM 4474 2004
FRSA/TRI 07320 2005
TAS 103 1995
L,++—
. Florida Building Code Online Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/28/2013
Date Validated 08/29/2013
Date Pending FBC Approval 09/08/2013
Date Approved 10/18/2013
Summary of Products
FL Model:Jj
Number or Name 'Description
16048.1 TRI-BUILT Roof Self-adhering, modified bitumen roof underlayments
erla ments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16048 R1 II er082713FINAL ABP UNDERLAYMENTS FL16048-
Approved for use outside HVHZ:Yes R1.Ddf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-315 Created by Independent Third Party: Yes
Other: 1.)The design pressure noted herein Evaluation Reports
pertains to use of foam-on the systems FL16048 R1 AE er082713FINAL ABP UNDERLAYMENTS FL16048-
overtop the self-adhering underlayment for IR1.odf
one particular application. See ER Section Created by Independent Third Party: Yes
5.5.2 for details. 2.)Refer to ER Section 5 for
other Limits of Use.
Baoh Next
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32WPhone:850.487-1824
The State of Florida is an AA/EEO employer.Copyright 2007.2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not
send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.
'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees ncensed under Chapter 455,F.S.must provide the Department
with an email address if they have one.The smalls provided may be used for official communication with the Ilcensee.However email addresses are public
record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455,F.S.,please click ttct.
Product Approval Accepts:
®® W
vcurity%. -i
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization *9503
TRINITY ERD 353 CHRISTIANOXFORD,, UNIT #13
CT 6478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Allied Building Products Corp / Evaluation Report A42960.10.12-111
TRI-BUILT Roofing Products FL16048-Rl
9050 Louisiana Street Date of Issuance: 10/25/2012
Merrillville, IN 46410 Revision 1: 08/27/2013
SCOPE:
This Evaluation Report Is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nleminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Each unit shall bear labeling In accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityJERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or Its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
+ The facsimile seal appearing was authorized
y, by Robert Nleminen,P.E.on 08/27/2013
s *•'a= This does not serve as an electronically signed
Robert J.M. Nieminen P.E. ''•,E`y ;�•••• �; document. signed,sealed hardcoples have been
' � ,.•' transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1983 to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved In the approval process of the
product.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by Allied Building Products
Corp., have demonstrated compliance with the following sections of the Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation
Requirements and Limitations/ Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001
1507.5.3
1504.6 Accelerated Weathering ASTM G155 2005
1504.3.1 Wind Uplift FM 4474 2004
1507.3.3 Installation Practice FRSA/TRI 07320 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity examination Reference Date
ERD (TST6049) Physical Properties P33360.06.10 07/01/2010
ERD (TST6049) Physical Properties P33370.03.11 03/02/2011
ERD (TST6049) Physical Properties P33370.04.11 04/26/2011
ERD (TST6049) Physical Properties P369.09,11 09/01/2011
ERD (TST6049) Physical Properties P37300.10.11 10/19/2011
FM Approvals (TST1867) Wind Uplift 3004091 01/12/2000
PRI (TST5878) Physical Properties PUSA-083-02-01 07/01/2008
UL, LLC. (QUA9625) Quality Control Multiple-Listing Agreement 02/27/2012
UL, LLC. (QUA9625) Quality Control Multiple-Listing Agreement 04/12/2012
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/24/2015
4. PRODUCT DESCRIPTION:
4.1 Self-Adherina Underlayments:
4.1.1 Tri-Built Granular-P Shingle Underlayment is a nominal 60-mil thick rubberized asphalt
waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM
D1970.
4.1.2 Tri-Built Tile and Metal HT Underlayment is a nominal 60-mil thick dual-layer rubberized
asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets
ASTM D1970 and TAS 103.
4.1.3 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-
surfaced, SBS modified bitumen roof underiayment, with a 36-inch sheet width.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111
Certificate of Authorization#9503 FL16048-Rl
Revision 1: 08/27/2013
Page 2 of 6
TRINITY ERa
5.3 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product
Is specifically referenced within FBC approval documents. If not listed, a request may be
made to the AH] for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.4 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1: ROOF COVER OPTIONS
Asphalt Foam-On Wood
Underlayment Shingles Nail-On Tile Tile Metal Shakes& Slate
Shingles
Tri-Built Granular-P Shingle Yes No No No Yes Yes
Underlayment
Tri-Built Tile and Metal HT Yes Yes Yes Yes Yes Yes
Underlayment See 5.4.1
Tri-Built Sand-R SA Shingle Yes No No No Yes Yes
Underlayment
5.4.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile
adhesion / long term aging data from an accredited testing laboratory is provided.
Tri-Built Tile and Metal HT Underlayment with Polyfoam PolyPro AH160
L Tri-Built Tile and Metal HT Underlayment with Dow TileBond
5.5 Allowable substrates are noted below:
5.5.1 Direct-Bond to Deck:
Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment
applied to:
New untreated plywood;
:- ASTM D41 primed new untreated plywood;
Existing plywood;
ASTM D41 primed existing plywood;
y ASTM D41 primed OSB;
Southern Yellow Pine;
ASTM D41 primed Southern Yellow Pine;
y ASTM D41 primed structural concrete,
Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads
for project).
Note:Allied Building Products Corp. does not require priming of new or existing plywood sheathing for use
with Tri-Built Granular-P Shingle Underlayment or Tri-Built Tile and Metal HT Underlayment. New or
existing plywood sheathing should be cleaned of all dirt and debris prior to application of these TRI-BUILT
membranes.
Tri-Built Sand-R SA Shingle Underlayment applied to:
:- Plywood;
ASTM D41 primed plywood.
Note: While not required over plywood, Allied Building Products Corp. recommends priming the deck if the
final roof cover is not slated for installation within 24 hours.
Note: Allied Building Products Corp. requires tongue-and-groove board decking be covered with plywood
or OSB prior to installation of the self-adhering underlayment.
5.5.2 Wind Resistance for Underlayment Systems in Foam-On Tile Al2nlications: FRSA/TRI 07320
does not address wind uplift resistance of all underlayment systems beneath foam-on tile
systems, where the underlayment forms part of the load-path. The following wind uplift
limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are
used in foam-on the applications. Maximum Design Pressure is the result of testing for wind
load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of
design wind pressures.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-Ri
Certificate of Authorization#9503 FL16048-R1
Revision 1: 08/27/2013
Page 3 of 6
TRINITY ERD
5.5.2.1 Maximum Design Pressure = -315 Dsf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Tri-Built Tile and Metal HT Underlayment.
5.5.2.2 All other direct-deck, adhered TRI-BUILT underlayment systems beneath foam-on the systems
carry a Maximum Design Pressure of-45 psf.
5.5.3 Bond-to-Insulation:
:- ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite
insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum-Fiber Roof
Board.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached
per minimum requirements of the prepared roof covering manufacturers Product Approval. For
installations under foam-on tile systems, insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM
4470,Appendix K or TAS 114,Appendix J.
5.5.4 Bond to Mechanically Attached Base Laver:
Y ASTM D226,Type I or II felt.
Note: For installations under mechanically attached prepared roof coverings, base layer shall be attached
per minimum codified requirements. For installations under foam-on tile systems, base layer shall be
attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
5.6 Exposure Limitations:
5.6.1 Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment shall
not be left exposed for longer than 90-days after installation.
5.6.2 Tri-Built Sand-R SA Shingle Underlayment shall not be left exposed for longer than 30-days
after installation
5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self-Adhered Underlayment Requirements as of
02/14/2011" for limitations for self-adhering underlayments used beneath tile roof systems.
TABLE 2:TILE SYSTEM OPTIONS PER FRSA/TRI 07320/8-05
System Underlay Section Reference Product(s)
Option
System One: 5 3.02E Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment
Mechanically Fastened Tile, No. 30/Self-Adhered Base Layer:ASTM D226,Type II
Unsealed or Sealed 6 3.02F Underlayment Top Layer: Tri-Built Tile and Metal HT
Underlayment System Underlayment
System Two: 4 3.021) Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment
Mechanically Fastened Tile, No. 30/Self Adhered Base Layer:ASTM D226,Type II
Sealed Underlayment 5 3.02E Underlayment Top Layer: Trl-Built Tile and Metal HT
System Underlayment
System Four"A": 4 3.021) Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment
Adhesive-Set Tile,Unsealed No. 30/Self Adhered Base Layer:ASTM D226,Type II
or Sealed Underlayment 5 3.02E Underlayment Top Layer: Tri-Built Tile and Metal HT
System Underlayment
System Four"B": 3 3.02C Self-Adhered Underlayment Trl-Built Tile and Metal HT Underlayment
Adhesive-Set Tile, Sealed No. 30/Self-Adhered Base Layer: ASTM D226,Type II
Underlayment System 4 3.021) Underlayment Top Layer:Tri-Built Tile and Metal HT
Underlayment
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-Ri
Certificate of Authorization#9503 FL16048-R1
Revision 1: 08/27/2013
Page 4of6
TRINITY ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with Allied Building Products
Corp. / TRI-BUILT published installation requirements subject to the Limitations set forth in
Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate (if applicable).
6.3 Tri-Built Granular-P Shinale Underlayment and Tri-Built Tile and Metal HT
Underlayment:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D1970
underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 For non-tile applications:
6.3.2.1 Back-nail selvage edge seams in accordance with the Allied Building Products Corp. / TRI-
BUILT Back-Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with
a minimum 1-inch diameter metal disk or Simplex-type metal cap nail, at a minimum rate of
12" o.c. The head lap membrane is to cover the area being back-nailed.
6.3.2.2 All seal-lap seams (selvage laps)
must be firmly rolled with a
minimum 28 Ib. hand roller to y
ensure full contact and adhesion.
For Tri-Built Tile and Metal HT
Underlayment, align the edge of the
top sheet to the end of the glue
pattern (the sheet will overlap the
fabric).
Overlap Seam;Tri-Built Tile and Metal HT Underlayment
6.3.2.3 Install to ensure full contact with approved substrates. Allied Building Products Corp. / TRI-
BUILT require a minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom
with approximately 40-lbs of load applied for the field membrane. Hand rollers are
acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are
not accessible to a large roller or broom.
6.3.3 For the applications (Tri-Built Tile and Metal HT Underlayment only):
6.3.3.1 Reference is made to Section 6.3.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4 Tri-Built Sand-R SA Shinale Underlayment:
6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 For non-tile aoolications:
6.4.2.1 While priming is optional, Allied Building Products Corp. recommends priming the deck if the
final roof cover is not slated for installation within 24 hours.
6.4.2.2 Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel
back the first 3 ft of release film.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111
Certificate of Authorization#9503 FL16048-RI
Revision 1: 08/27/2013
Page 5 of 6
TRINITY ERD
6.4.2.3 Adhere the exposed part to the substrate and unroll the remaining membrane as far as
possible.
6.4.2.4 Once the entire length of membrane is in place, peel-off the release film diagonally while
holding the membrane tight. Firmly roll the membrane into place to achieve a bond.
6.4.2.5 Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams
should be 6-inches and staggered not less than 2-ft from vertical seams in the course below.
All over-granule end-laps shall be sealed using either heat-welding or hot air welding
techniques.
6.4.2.6 When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing
in the overlap area at the top of the sheet at 12-inch o.c,
6.4.2.7 For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper
and center sheet over valley or ridge. Drape and press sheet into place, working from the
center of the valley or ridge in each direction. For valleys, apply the sheet starting at the
lowest point and work upward.
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
B. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL, LLC - QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-Ri
Certificate of Authorization#9503 FL16048-111