Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2 a ProfessionalRegulation ?,•, BusinessSOS Home Log in User Registration Hot Topics Submit Surcharge Stats&Fads Publications FBC Staff MS Site Map Links Search �� Professibnal cilProduct Approval ' USER:Public User L a < "i Product Approval Menu>Product or Application search �r >AoohcaUon List>Application Detail �j FL# FL16048-R1 NOV 2 7 L01t7 Application Type Revision {'ER"f{?"Tf iNIG Code Version 2010 St. Lucie Co untv, r F� Application Status Approved Comments Archived f Product Manufacturer Address/Phone/EmailTRI-BUILT Roofing Produ ` Y �ff '� " 9050 Louisiana Street Merrillville,IN 46410 (201)842-2449 david.rulz@tribuiltmateriaisgroup.com Authorized Signature David Ruiz david.ruiz@tribuiltmaterialsgroup.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david.raiz@tribuiltmateriaisgroup.com Quality Assurance Representative Address/Phone/Emall Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/24/2015 Validated By John W. Knezevlch, PE Validation Checklist-Hardcopy Received Certificate of Independence FL16048 Rl COI Trinity ERD Cl Nieminen 2013 odf Referenced Standard and Year(of Standard) t d Year ASTM D1970 2001 ASTM G155 2005 FM 4474 2004 FRSA/TRI 07320 2005 TAS 103 1995 L,++— . Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/28/2013 Date Validated 08/29/2013 Date Pending FBC Approval 09/08/2013 Date Approved 10/18/2013 Summary of Products FL Model:Jj Number or Name 'Description 16048.1 TRI-BUILT Roof Self-adhering, modified bitumen roof underlayments erla ments Limits of Use Installation Instructions Approved for use in HVHZ: No FL16048 R1 II er082713FINAL ABP UNDERLAYMENTS FL16048- Approved for use outside HVHZ:Yes R1.Ddf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-315 Created by Independent Third Party: Yes Other: 1.)The design pressure noted herein Evaluation Reports pertains to use of foam-on the systems FL16048 R1 AE er082713FINAL ABP UNDERLAYMENTS FL16048- overtop the self-adhering underlayment for IR1.odf one particular application. See ER Section Created by Independent Third Party: Yes 5.5.2 for details. 2.)Refer to ER Section 5 for other Limits of Use. Baoh Next Contact Us:: 1940 North Monroe Street,Tallahassee FL 32WPhone:850.487-1824 The State of Florida is an AA/EEO employer.Copyright 2007.2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395. 'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees ncensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The smalls provided may be used for official communication with the Ilcensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455,F.S.,please click ttct. Product Approval Accepts: ®® W vcurity%. -i EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization *9503 TRINITY ERD 353 CHRISTIANOXFORD,, UNIT #13 CT 6478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Allied Building Products Corp / Evaluation Report A42960.10.12-111 TRI-BUILT Roofing Products FL16048-Rl 9050 Louisiana Street Date of Issuance: 10/25/2012 Merrillville, IN 46410 Revision 1: 08/27/2013 SCOPE: This Evaluation Report Is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nleminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Each unit shall bear labeling In accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityJERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or Its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: + The facsimile seal appearing was authorized y, by Robert Nleminen,P.E.on 08/27/2013 s *•'a= This does not serve as an electronically signed Robert J.M. Nieminen P.E. ''•,E`y ;�•••• �; document. signed,sealed hardcoples have been ' � ,.•' transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved In the approval process of the product. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by Allied Building Products Corp., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.5.3 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity examination Reference Date ERD (TST6049) Physical Properties P33360.06.10 07/01/2010 ERD (TST6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST6049) Physical Properties P369.09,11 09/01/2011 ERD (TST6049) Physical Properties P37300.10.11 10/19/2011 FM Approvals (TST1867) Wind Uplift 3004091 01/12/2000 PRI (TST5878) Physical Properties PUSA-083-02-01 07/01/2008 UL, LLC. (QUA9625) Quality Control Multiple-Listing Agreement 02/27/2012 UL, LLC. (QUA9625) Quality Control Multiple-Listing Agreement 04/12/2012 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/24/2015 4. PRODUCT DESCRIPTION: 4.1 Self-Adherina Underlayments: 4.1.1 Tri-Built Granular-P Shingle Underlayment is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.1.2 Tri-Built Tile and Metal HT Underlayment is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.1.3 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand- surfaced, SBS modified bitumen roof underiayment, with a 36-inch sheet width. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111 Certificate of Authorization#9503 FL16048-Rl Revision 1: 08/27/2013 Page 2 of 6 TRINITY ERa 5.3 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are as follows: TABLE 1: ROOF COVER OPTIONS Asphalt Foam-On Wood Underlayment Shingles Nail-On Tile Tile Metal Shakes& Slate Shingles Tri-Built Granular-P Shingle Yes No No No Yes Yes Underlayment Tri-Built Tile and Metal HT Yes Yes Yes Yes Yes Yes Underlayment See 5.4.1 Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment 5.4.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Tri-Built Tile and Metal HT Underlayment with Polyfoam PolyPro AH160 L Tri-Built Tile and Metal HT Underlayment with Dow TileBond 5.5 Allowable substrates are noted below: 5.5.1 Direct-Bond to Deck: Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment applied to: New untreated plywood; :- ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; y ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; y ASTM D41 primed structural concrete, Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note:Allied Building Products Corp. does not require priming of new or existing plywood sheathing for use with Tri-Built Granular-P Shingle Underlayment or Tri-Built Tile and Metal HT Underlayment. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of these TRI-BUILT membranes. Tri-Built Sand-R SA Shingle Underlayment applied to: :- Plywood; ASTM D41 primed plywood. Note: While not required over plywood, Allied Building Products Corp. recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: Allied Building Products Corp. requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.5.2 Wind Resistance for Underlayment Systems in Foam-On Tile Al2nlications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam-on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-Ri Certificate of Authorization#9503 FL16048-R1 Revision 1: 08/27/2013 Page 3 of 6 TRINITY ERD 5.5.2.1 Maximum Design Pressure = -315 Dsf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Tri-Built Tile and Metal HT Underlayment. 5.5.2.2 All other direct-deck, adhered TRI-BUILT underlayment systems beneath foam-on the systems carry a Maximum Design Pressure of-45 psf. 5.5.3 Bond-to-Insulation: :- ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum-Fiber Roof Board. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturers Product Approval. For installations under foam-on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470,Appendix K or TAS 114,Appendix J. 5.5.4 Bond to Mechanically Attached Base Laver: Y ASTM D226,Type I or II felt. Note: For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment shall not be left exposed for longer than 90-days after installation. 5.6.2 Tri-Built Sand-R SA Shingle Underlayment shall not be left exposed for longer than 30-days after installation 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self-Adhered Underlayment Requirements as of 02/14/2011" for limitations for self-adhering underlayments used beneath tile roof systems. TABLE 2:TILE SYSTEM OPTIONS PER FRSA/TRI 07320/8-05 System Underlay Section Reference Product(s) Option System One: 5 3.02E Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment Mechanically Fastened Tile, No. 30/Self-Adhered Base Layer:ASTM D226,Type II Unsealed or Sealed 6 3.02F Underlayment Top Layer: Tri-Built Tile and Metal HT Underlayment System Underlayment System Two: 4 3.021) Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment Mechanically Fastened Tile, No. 30/Self Adhered Base Layer:ASTM D226,Type II Sealed Underlayment 5 3.02E Underlayment Top Layer: Trl-Built Tile and Metal HT System Underlayment System Four"A": 4 3.021) Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment Adhesive-Set Tile,Unsealed No. 30/Self Adhered Base Layer:ASTM D226,Type II or Sealed Underlayment 5 3.02E Underlayment Top Layer: Tri-Built Tile and Metal HT System Underlayment System Four"B": 3 3.02C Self-Adhered Underlayment Trl-Built Tile and Metal HT Underlayment Adhesive-Set Tile, Sealed No. 30/Self-Adhered Base Layer: ASTM D226,Type II Underlayment System 4 3.021) Underlayment Top Layer:Tri-Built Tile and Metal HT Underlayment Exterior Research and Design,LLC. Evaluation Report A42960.10.12-Ri Certificate of Authorization#9503 FL16048-R1 Revision 1: 08/27/2013 Page 4of6 TRINITY ERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with Allied Building Products Corp. / TRI-BUILT published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Built Granular-P Shinale Underlayment and Tri-Built Tile and Metal HT Underlayment: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For non-tile applications: 6.3.2.1 Back-nail selvage edge seams in accordance with the Allied Building Products Corp. / TRI- BUILT Back-Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. The head lap membrane is to cover the area being back-nailed. 6.3.2.2 All seal-lap seams (selvage laps) must be firmly rolled with a minimum 28 Ib. hand roller to y ensure full contact and adhesion. For Tri-Built Tile and Metal HT Underlayment, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Overlap Seam;Tri-Built Tile and Metal HT Underlayment 6.3.2.3 Install to ensure full contact with approved substrates. Allied Building Products Corp. / TRI- BUILT require a minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.3.3 For the applications (Tri-Built Tile and Metal HT Underlayment only): 6.3.3.1 Reference is made to Section 6.3.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4 Tri-Built Sand-R SA Shinale Underlayment: 6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non-tile aoolications: 6.4.2.1 While priming is optional, Allied Building Products Corp. recommends priming the deck if the final roof cover is not slated for installation within 24 hours. 6.4.2.2 Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111 Certificate of Authorization#9503 FL16048-RI Revision 1: 08/27/2013 Page 5 of 6 TRINITY ERD 6.4.2.3 Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. 6.4.2.4 Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. 6.4.2.5 Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. 6.4.2.6 When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c, 6.4.2.7 For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. B. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC - QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42960.10.12-Ri Certificate of Authorization#9503 FL16048-111 Revision 1: 08/27/2013 Page 6 of 6