Loading...
HomeMy WebLinkAboutProduct Approval i i I � MIAMI-DARE COUNTY ,PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) j 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 j T(786)315-2590 F(786)315-2599 www.miamidadexov/economy NOTICE OF ACCEPTANCE (NOA) Continental Materials,Inc. 1614 Old York Road ' Abington,PA 19001 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or-material tested for quality assurance purposes.If this product or material failsto perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material!fails to meet the requirements of the applicable building code. . This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. ' I DESCRIPTION: Continental Materials All Weather#30; Continental Materials All Weather#90 All LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filedland there has been no change in the applicable building code negatively affecting the performance of this product. i i TERMINATION of this NOA will occur after the expiration date or if there hasbeen a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOAt as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. j ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. i INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. j This NOA consists of pages 1 through 2. The submitted documentation was reviewed by Alex Tigera. i NOA No.: 12-0612.30 ruathI•naoe couNrr Expiration Date: 05/02/18 Approval Date: 05/02/13 Page 1 of 2 I j 1 I ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment r Material: Asphalt i PRODUCTS DESCRIPTION: i Test ;' Product Product Dimensions Specification Description Continental Materials All 36"x 72'rolls ASTM D 226 Type H Asphalt Saturated Felt Underlayment Weather#30 Continental Materials All 36"x 36'rolls ASTM D 6380 Class M Asphalt Saturated Felt Underlayment Weather#90 Type II I ' MANUFACTURING LOCATION: 1. Mexicali,Mexico EVIDENCE SUBMITTED: I Test Agency Test Identifier Test Na /Rep Date PRI Construction Materials CMI-031-02-01 ASTM D 226 I 05/09/12 Technologies CMI-032-02-01 ASTM D 6386,; 05/09/12 � i 1 INSTALLATION 1. Continental Materials All Weather#30 and All Weather#90 shall be installed in strict compliance with applicable Building Codes. , I LIMITATIONS: 1. Fire classification is not part of this acceptance. R 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. Continental Materials All Weather#30 and#90 underlayment shall be installed in strict compliance with applicable Building Code. 3. Continental Materials All Weather#30 and#90 underlayments shall not be left exposed)as a temporary roof for longer than 30 days of application. 4. All products listed herein shall have a.quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 5. All packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and a yellow line in the center of the roll to identify the ASTM Standard designation or the Miami-Dade County Product Control Seal as shown below. MIAM-DADE COUNTY END OF THIS ACCEPTANCE NOA No.: 12-061230 Mu►MI•DADe COUNTY Expiration Date: 05/02/18 Approval Date: 05/02/13 Page 2 of 2 i 1 r .I- Y I I 1 ' EXTERIOR RESEARCH&DESIGN,LLC. ICertificate ofA.thorization#9503 TRINI 1 1'�y I ERD 353 CHRISTIAN STREET,UNIT #13 QOi ' 1 OXFORD,CT 06478478 PHONE:(203)262-9245 ' FAX:(203)262-9243 I EVALUATION REPORT i Owens Corning Evaldation Report 037940.02.12-R7 One Owens Corning Parkway FL10674-1112 Toledo,OH 43659 1 'Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: . This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has,been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition!(2014) Florida Building Code sections noted herein. { a DESCRIPTION: Owens Corning Asphalt Roof Shingles j I LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. , I CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl�ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then its shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to thle user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: y►1t�npr,!�,q-- I Robert J.M.Nieminen,P.E. •�%�•C�l = '��.•,�,`.' The facsimile seal appearing was authorized by Robert Nieminen, s�:;, �.;y r„l.al:� is P.E.on 04/16/2016.This does not serve as an electronically signed :��JJhuina«<t Florida Registration No.59166,Florida DG4 ANE1983 document Signed,sealed hardwples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: I 1. TrinityI ERD does not have, nor does it intend to acquire or will it acquire, a financial interest,in any company manufacturing or distributing products it evaluates. I 2. TrinityI ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are,'in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting)or design guidance unless retained specifically for that purpose. I I f I ' 1 TRINITY I ERD ROOFING SYSTEMS EVALUATION: i ' 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles I Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: I' j Section Property Standard j Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161' 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 t , 3. REFERENCES: gniinf Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 I 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 i 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 i 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire*are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 DevonshireTm are fiberglass reinforced,5-tab asphalt roof shingles. j ' i • i 4.1.4 Duration•, TruDefinition Duration•, Duration Premium Cool, TruDefinition Duration* Designer Color Collection,TruDefinition•Oakridge, Oakridge and WeatherGuard®THP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip& Ridge Shingles, High Ridge,WeatherGuard• HP Hip& Ridge Shingles, ProEdge Hip &Ridge Shingles and DuraRidgeTm Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. I Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7 Cerdflcate of Authorization#9503 FL20674-R12 Revision 7:04/18/2016 + Paget of 8 I ' t I , i y I 7-' TRINITY I ERS 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC iTables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (V„It=194 mph). Refer to'�Section16 for installation requirements to meet this wind rating. { 5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus not herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (V„It=194 mph) . Refer to Section 6 for installation requirements to meet this wind rating. t 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance andl installaltion limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florlida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections;11507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: i 6.2.1 Installation of asphalt shingles shall comply with the manufacturer s current;published instructions, using minimum four (4) nails per shingle in accordance with FBC Section's 1507.2 or R905.2, with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. I ➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five�(5)nails per strip. i II g published information on wind resistance and install Refer to Owens Corning limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements; but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltunderlayritent Dei:k: Ritunaeda(lent I Declt � dkb Self•adhered. I undedayment Weatherl ocko und4layment Ddp edge Drip— Dtip.edge •0613---. edge edge l i Nails,located Natlslonted c 2=3"from save am,ed ;Install first Self-sealing adhesive :'' sdt ea ing adhesive St.n firsriPP" positioned along rromovedrsmp D nedalongeave shmglewhh ` \i 6 removed Starter Strip shingle overhangs eaves and rakes r tarter5UZp' eaJesandrekest/4'-3/4' /a 447 sPWsaveihangs t , I Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 Certijlcate ofAutharizatfon#9503 + FL10674-R12 I Revision 7:04/18/2016 Page 3 of 8 i I � ' I i I ' ��'JfRINITYIERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Monsird'or Area para Normal Mansard or, Area pars, Wind Areas High Wind deavanes,y WrndAreas HighlWind' desvanes.y Aree para vierrtoa normafes Areas, triontos fuertes 'Area pare vleirtas normales Ansa vlentos fuer;es. �" (A) r Ft z• (g z t• t (A)' t' r I z• lel z. t. tt• it• tzt �, tz I I W Exposure. 5 5i8"Exposure Exposici6h' ExiiosieiSs I 6.2.7 Minimum Nailing—Berkshire®: SeaLahnl kdp_ Sealant strip lira de settada. �{3 tua de sellador I„I I t� $th", $Yt $Vf $VP } , ,8�h. I 81h., 8w, 8 i Standard Fastening Pattern 6-Nail Fastening Pattern i i $aaiap(strip La Ura do sd fador i i! ' Vftea--���----►•.• .��— s� r' -►• , R 8. ' 8 i1t. 111 2., h Asphah reofo fig cemeni Cenento ddtacho de astalyd. Mansard or Steep Slope Fastening Patterri 1 I 1 I , Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117 Certificate of Authorizadon#9503 ' F1.10674-1132 Revision 7:04/18/2016 } Page 4 of 8 I I 1 1 1 i I I i !''' TRINITY I ERD. 6.2.8 Minimum Nailing—Devonshire ': I , I 1" 7" 8" 8" I__8L__. �" I 1" i B -" H I 1 47 • p0Ye4 al 1 Nails d 53/8"exposure Sealant location 31 Exposid6nde5-5(4pu1Ig UhicadbndefSellador sw• ` �_ Ten 1"S ots of As halt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern i 6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration® Premium Cool &TruDefinition Duration Designer Color Collection: _ I r 4-Nall Fastening Pattern' I 6?NellFastening Pattern, SuroNafldvfastenhq ana wxrm SMNantWMM9"Wki h NaII.TYP1nt I Nail lypleal. +r t" m �•.m�..es.,w •m >w,.o o.mcm,�s.w,a .. eo.«,.r�o .i.LT�se.,c>,"«." .a..•,ra,.e+..vv • 6.1A'riafa- 64/6F1 I .6-69• li 1 Standard Fastening Pattern !I6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12. ! SuroNelW feetenln9 eros raoin ' ..,Na6,ryplul I.. I 1• @' ! 6.116•5. I I Four f•6twtl of IupnaR Roomg Cement Mansard or Steep Slope Fastening Patter I I , ! i I � I I Exterior Research and Design,U.C. I Evaluation Report 037940.02.12-R7 Certiftcate of Authorization#9503 F110674-R12 Revision 7:04/18/2016 Page 5 of 8 I I Y '`? TRINITY I ERD: I 6.2.1 Minimum Nailing—TruDefinition�Oakridge®,Oakridge®: , 4Nail-Ratter 6=NallPatteii� 40p!4ew4.davos. Esquonavoir6davos t' I T IE— ;r•_—�I IE— ,r—tel 4 i 668 E+glosure Nail,' 5618 ExposuELI re, 5Jr1Na9. 6458" to aonde55/BPu10: Cfaroi Exposaemnde55/8prdg BgMWposyle. Cfivas P ...t F.xposF+zdade5b/8pufg � :E><posraonde66/Spufg. LI i Standard Fastening Pattern �6-Nail Fastening Pattern 'FasteningforSlopes,GreaterThari`21;12 SureNslk9 rafr0nln9 oreaMM N.O,'rypiW , +^. +r +r r I I'I Fouri•Spo+sol ASPrWt RoonngC-' f Mansard or Steep Slope Fastening Pattern i 6.2.1 Minimum Nailing—WeatherGuard®HP: i. I 1' 1- ilnalriltli;Vb1� � , Si••� t wi`rre'1�N11 liui , • I I i i I, Exterior Research and Design,U.C. Evaluation Report 037940.02.12-117 Certykate oJAuthorliatlon#9503 F1.306741132 Revision 7:04/18/2016 Page 6 of 8 I i I I' , i , I I { I I ' t � 1 TRINITY ERD: 6.3 Hip&Ridge Shingles: { I 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge,WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4) nails per shingle. Installation of DuraRidgeTMl Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Referl,to Owens Corning published information on wind resistance and installation limitations, including thel use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: FIg..1! T Fig.2 �'•' _"prewiGnsvuna s ') SideViiw; A..., Naffs Nails,-, III- f'I Nails I _.• 7� 2: 70'L ed 2-.�• A� I 1• 4. Piece I 1 I 1- A I I I I I I I I I I L j Exposure` I I 1 � 1 I I 1 I i I U 1' I . 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig C &RidgeS6gle Fas9t9ening Elg. pr�ba Wllltl 44 A TopVkwprawflV'rl Nalls--`"�4'4 NOILs flails A; f 5, � ose= re V. Exposure III 1'; i "I L , f , i ' t , I Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization 119503 I FL10674-1112 Revision 7:04/18/2016 f Page 7 of 8 �I TRINITY l ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: 11i Prevailin $t8n'Jaid r l Fastening; Wind Direction Seslent Ship' Pattern, I, Exposure Fasten 7'f: 6°exposure' i.Co`ver Exposed 1 �:": ! •+ Fastenerswith., Roof Cemerrt' 6.3.6 Minimum Nailing—DuraRidgel Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. !Refer to Owens Corning published installation instructions for their minimum requirements. We FFaiaiin Wind i)I�cetlan.,.. TeP -Pla Diroit,ondom,metcdrrant� .I�-. V(msvperlor, 1'I -Oirora6ndoltiiaim'prodwni�nfa �I t - S J 9 N Y 1 h." 'LbID Naito---mayh „, •: Ovwm C.olN,g SugoNaVl' i w' Clmrrol 5 � e ;1 1 I ;l 1•�� .i is � m�~''a., �- i s, 4. �l„�kil 1 - I I i ' 7. (LABELING: I ' 7.1 Labeling shall be in accordance with the requirements the Accredited Qluality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. I 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. , 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. t 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- f , i Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7 Certlflcate of AuthorizaHon#9503 FL30674-R12 Revision 7:04/18/2016 J Page 8 of 8 I � i i �