HomeMy WebLinkAboutProduct Approval I]IADE
FILE COPY
MIAMN .
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
Continental Materials,Inc.
1614 Old York Road
Abington,PA 19001
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Continental Materials All Weather#30; Continental Materials All Weather#90
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 2.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0612.30
MIAMEQADE COUNTY Expiration Date: 05/02/18
Approval Date: 05/02/13
Page 1 of 2
ROOFING COMPONENT APPROVAL
Catesory: Roofing
Sub-Cateaory: Underlayment
Material: Asphalt
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Continental Materials All 36"x 72' rolls ASTM D 226 Type H Asphalt Saturated Felt Underlayment
Weather#30
Continental Materials All 36"x 36' rolls ASTM D 6380 Class M Asphalt Saturated Felt Underlayment
Weather#90 Type H
MANUFACTURING LOCATION:
1. Mexicali, Mexico
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials CMI-031-02-01 ASTM D 226 05/09/12
Technologies
CMI-032-02-01 ASTM D 6380 05/09/12
INSTALLATION
1. Continental Materials All Weather#30 and All Weather#90 shall be installed in strict compliance with
applicable Building Codes.
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. Continental Materials All Weather#30 and#90 underlayment shall be installed in strict
compliance with applicable Building Code.
3. Continental Materials All Weather #30 and #90 underlayments shall not be left exposed as a temporary roof for
longer than 30 days of application.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
5. All packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and a
yellow line in the center of the roll to identify the ASTM Standard designation or the Miami-Dade County
Product Control Seal as shown below.
MIAMMADE COUNTY
gj
11...•
END OF THIS ACCEPTANCE
NOA No.: 12-0612.30
CMLALMFDADE COUNTY Expiration Date: 05/02/18
Approval Date: 05/02/13
Page 2 of 2
4 ,
EXTERIOR RESEARCH & DESIGN, LLC.
4 '
"2,/4�-:�-=r Certificate of Authorization k9503
TRINITY ERD 353 CHRISTIAN STREET,UNIT#13
l sEd! OXFORD,CT 06478
PHONE:(203)262-9245
r,
FAX: 203 262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1119
FILFCOPV
1 Campus Drive FL1
Parsippany, NJ 07054 Date of Issuance: 01/03/03/20082008
Revision 19: 12/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
1No 3?.xs •••�.
r
g+ATE OF ;•z4 c
Robert J.M. Nieminen P.E. F$ •.•• ''G� The facsimile seal appearing was authorized by Robert Nieminen,
en,or= At'p`, P.E.on 12/15/2015.This does not serve as an electronically signed
-.J�.nn�t�r:•
Florida Registration No.59166, Florida DCA ANE1983 document. Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,R905.2.3 Physical Properties ASTM D1970 2009
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 01NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CAS367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R19
Certificate of Authorization#9503 FL10124-R17
Revision 19: 12/15/2015
Page 2 of 6
TRINITY ERS
Entity Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA068S6 05/15/2009
UL(TST 1740) ASTM D3161,D71S8,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D71S8,133462 10CA35554 03/05/2010
UL(TST 1740) ASTM D3161,D71S8, D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158, D3462 10CA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D71S8,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158, D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158, D3462 4786875675 07/17/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Mobile,AL 06/19/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Myerstown,PA 07/21/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Tuscaloosa,AL 06/26/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Michigan Cty,IN 05/14/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Shaffer,CA 07/16/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 06/24/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Minneapolis,MN 07/14/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 07/10/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Baltimore,MD 07/21/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Tampa,FL 06/26/2015
UL, LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 07/15/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21, Ennis,TX 07/09/2015
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 07/16/2015
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax', Royal Sovereign' and Sentinel' are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot', Camelot' ll, Country Mansion' II, Glenwood'", Grand Canyon', Grand Sequoia', Grand Sequoia'
IR, Monaco', Sienna', Timberline American Harvest', Timberline' ArmorShield'"° ll, Timberline' Natural
Shadow', Timberline HD', Timberline' Cool Series, Timberline Ultra HD' and Woodland' are fiberglass
reinforced, laminated asphalt roof shingles.
4.1.3 Slateline' is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip& Ridge Shingles:
4.2.1 Seal-A-Ridge' Ridge Cap Shingles, Seal-A-Ridge' IR Impact-Resistant Ridge Cap Shingles and Timbertex'
Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strips:
4.3.1 Pro-Start' Starter Strip Shingles and WeatherBlocker'" Premium Eave/Rake Starter Strip are starter strips
for asphalt roof shingles.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R19
Certificate of Authorization#9503 FL10124-R17
Revision 19:12/15/2015
Page 3 of 6
F)o
TRINITY ERD
4.3.2 QuickStart`I Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified
bitumen starter strip,nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-inch or less.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vdsd = 150 mph (V,„ = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in all wind zones up to
Vd,d= 150 mph(V,„ = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip and
QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
Camelot, Camelot Il, Grand Canyon, Grand Sequoia, Grand Sequoia IR, and Woodland require minimum
five(5) nails per shingle.
Slateline requires minimum six (6) nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1119
Certificate of Authorization#9503 FL10124-1117
Revision 19: 12/15/2015
Page 4 of 6
CQ
TRINITY ERD
6.4 Hip& Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles and Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles shall
comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-
inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof &
Flashing Sealant".
115 Sealant
1^ (292 mm) 1" Sellante
(25 mm) (25 mm) Enduit d6tancheite
I 12
(305 mm)
Nail
Clavo
6 5i8'-7 5/8" Clouer
(168-194 mm)
12" _
(305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current
published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and
beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
I' ' Se,.At
1' {191��n; t' SggantQ
rr-' X25 rnm `
Gram•' ^e'--rc1c•t
I
v acv
4
6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.S. Staples are not permitted.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R19
Certificate of Authorization 119503 FL10124-R17
Revision 19: 12/15/2015
Page 5 of 6
QTRINITY ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625; (847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1119
Certificate of Authorization#9503 F1.10124-1117
Revision 19: 12/15/2015
Page 6 of 6