Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: DATE FILED: \� 11 PERMIT# n 1- U REVISION FEE: RECEIPT# PLANNING&DEVELOPMENT SERVIC Please advise asap if we can BUILDING&CODE REGULATION DIVISION install cabinet in new location 2300 VIRGINIA AVENUE T" QVI FORT PIERCE,FL 34982-5652 (772)462-1553 BY: ....................... APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE permit SLC 1711-0467 R/W 017-136 ADDRESS: 5811 Deer Run Dr#CATV,Fort Pierce 34951-at FPL pole in front yard of 5809 DETAILED DESCRIPTION OF PROJECT REVISIONS: because dense root system has made it impossible to dig,necessary to relocate Comcast cabinet to FPL pole/handhole between 5803 and 5805. Address has changed the location in GIS system, Selena Griffett approved relocation. CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: Fr13nn1574 ST. LUCIE CO CERT. #: 203A2 BUSINESS NAME: Gary J Gifford,Inc. QUALIFIERS NAME: Gary)Gifford ADDRESS: 350 SW Linden St CITY: Stuart STATE: FL ZIP: 34997 PHONE(DAYTIME): 772-286-0954 FAX: 772-219-0146 OWNER/BUILDER INFORMATION: NAME: Comcast-Anthony Springsteel,Construction Supervisor ADDRESS: 3960 RCA Blvd,Suite 6002 CITY: Palm Beach Gardens STATE: FL ZIP: 33410 PHONE(DAYTIME: 561-804-0973 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: n/a ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME): FAX: SLCCC: 9/23/09 Revised 06/30/17 REVISION PrI, Gary J.Gifford,Inc. EC 13001574 ',4 Electrical Contractor PCN: IORTHBLVO-•i-------------1- ............ 350 SW Linden Street 1313-502-0130-000-5 Stuart,FL 34997 0.0............. ' D FPL Service Address: 3 (772)286-0954 office (772)219-0146 fax 5811 Deer Run Dr#CATV s r` Fort Pierce 34951 Date: June 29, 2017 Meter AA15054 o Q v Project:Comcast Power Supply Job Description: Install new 1 Node SLO10B Comcast power supply cabinet and feeder on the south side of ' �.� Goif CMb FPL-Jose Hernandez FPL pole located approx.273 ft 772-489-6255 south of Turnpike Feeder Rd, 18 jose.hernandez@fpl.com ft west of Deer Run Dr. Remove �1. damaged power supply cabinet when the new one is energized _- -�INORIORb., - -- ----iNDRIORD V aec�a 'v �Jt�Q\KeF ee 05 ft o` FPL 18 ft z' old CAN ft f new CATV ' qd �er9`tied e��s e +/- 168 ft p�2 rem new CATV hand l — — — — hole, FPL Drilling and Engineering, Inc. BY: ...................... FIELD DENSITY TEST REPORT LAB NO: 177326-29 DAIS 11/6/2017 CLIENT: Premeir Pools&Spas Inc. ORDER NO: 12780 PROJECT: Polland Residence 7100 Sebastian Road Fort Pierce,Florida TECH: P.H TEST NO: LOCATION OF TEST DEPTH(IN) 1) Approx. East Side of Swimming Pool Patio Area 0-12 BFP 2) Approx.South Side of Swimming Pool Patio Area 0-12 BFP 3) Approx.West Side of Swimming Pool Patio Area 0-12 BFP 4) Approx.North Side of Swimming Pool Patio Area 0-12 BFP TEST NUMBER: 1) 2) 3) 4) MOISTURE CONTENT: 9.9% 9.1% 8.7% 8.2% FIELD DENSITY: 107.2 108.9 107.9 109.1 FIELD COMPACTION: 96.5% 98.1% 97.2% 98.2% PERCENT REQUIRED: 95% 95% 95% 95% MAXIMUM DRY DENSITY: 111.05 111.05 111.05 111.05 PROCTOR LAB NUMBER: 177325 177325 177325 177325 Respectfully Sub ted, D&N R 1 G& ENGI EF N ,INC. NOV 8 - 2017 Don rein,P.E. Florida Reg.#28585 1499 S.W. 30th Avenue • Suite#11 • Boynton Bea 1, __ Office: (561) 742-2988 • Fax: (561) 742-2987 Website: dndrilling.com • Email: Dan@dndrilling.com Drilling and Engineering, Inc. N01 3 Soils Laboratory Test Report Proctor Analysis ' ...................... Project: 12701 Date: 10/16/2017 Location: Building Pad Backfill Material Sampled by: P.H Client: Premeir Pools&Spas Inc. Tested by: D.Z Project: Swimming Pool Patio Sample# 177325 7100 Sebastian Road Fort Pierce,Florida Description: Grayish Brown M-F Grained Silica Sand s/Rock&Rock Fragments Mold Volume(FtA3) = 0.0333 Mold Weight(Lb) = 10.348 Soil Specific Gravity = 2.7 CAN M Can&Wet Soil Can&Dry Soil Mold&Moist Wet Density Dry Density Weight(g) Weight(g) Weight(g) Soil Weight(Lb)Moist Content(K)(lb/fM3) (Ib/k^3) 1 56.75 291.24 277.67 13.76 4.89 102.51 97.73 2) 56.75 293.45 275.98 14.08 6.33 112.19 105.51 3) 56.75 297.19 273.23 14.32 8.77 119.25 109.63 4 56.75 1 299.76 1 271.40 1 14.43 10.45 122.65 1 111.05 5 56.75 300.11 1 271.15 14.28 10.68 118.21 106.80 6) 56.75 303.10 269.12 14.14 12.63 113.76 101.01 Compaction Test 115 < 110 105 t= W 100 0 c 95 90 5 6 9 10 11 13 MOIST CONTENT(%) JDi ed, G& REVISION AV 8 - 2017 ' Florida Reg.#285851499 S.W. 30th Avenue • Suite#1 1 • Boynton Beach, FL 33426 Office: (561) 742-2988 • Fax: (561) 742-2987 Website: dndrilling.com • Email: Dan@dndrilling.cotn