HomeMy WebLinkAboutProduct Approval TABUILDING PRODUCTS
CREEK ,Asphalt Shingles
TECHNICAL"SERVICES,LLC I
PRODUCT DESCRIPTION
,I II
Elite Glass-Seal® 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 34ab
(Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass=Seal 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self:sealing, 3-tab
(Frederick•& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4"x 36",ASTM D 7158, Class Hself-sealing, 3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-�HVHZ only. 4
Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle •surfaced ;with mineral granules
Joplin,Phillipsburg& complying with ASTM D-3462.
Tuscaloosa)
Heritage®Premium 13-1/4" x. 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas,Frederick, reinforced, laminated architectural asphalt shingle !surfaced with mineral granules
Phillipsburg& complying with ASTM D 3462.
Tuscaloosa) 4
Heritage®Premium 12" x 36",,ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick) laminated architectural asphalt shingle surfaced with mineral 'granule's complying with
ASTM D 3462.
Heritage®Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7118,Clasb+H fibelass reinforced
,
(Phillipsburg) laminated architectural asphalt shingle surfaced with lmineralir9granules complying with
ASTM D 3462.
Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and AS M D 7,,1.58, Class H fiberglass
(Dallas&Frederick). reinforced, laminated architectural asphalt shingle surfacea with mineral granules
complying with ASTM D 3462.
Heritages Woodgate12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced,•laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with;ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
i• '
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick.&Joplin). shingle surfaced with mineral granules complying with'lASTM D.3462.
Vinta e®Hi and Ride 12"x 12`', ASTM D 3161, Class F fiberglass reinford,d, hi
I 9 p 9 g p and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.2 FL18355-R2 Page.2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61020-3. jThe manufacturer shall notify CREEK
Technical Services,.LLC of any product changes or quality assurance changes throughout the duration'for which this report is valid.
This evaluation report-does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressedberein.
,I
p
.I i ii M
I
'I
TAMO BUILDING PRODUCTSCREEK As halt Shin les` TECHNICA_
SERVICES, LLC
INSTALLATION
Elite Glass-Seal® Basic Wind Speed(Vut): Max. 194 mph
(Frederick,Joplin& Basic Wind Speed(Va,d): Max. 150 mph
Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plyw'o'od or wood plank for
Glass-Seal new construction; Min.11 15/32 d in. plywood existing
(Frederick,Joplin(Non- construction.
HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
tin
new construction;Min.7/16 in.OSB.exisg construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FB& equirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-1/8 inch e'xposureilin accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail;Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-1/8-inch 61xposure';in accordance with FBC
requirements and manufacturer's., published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or T Nail Pattern"detailed below.
NAILS .1
�, min Iii i
I I.
Nailing G-718"
Area _..... ......... ........_ .......:_ I.
i
Butt Edge
Figure 1. Elite Glass-Seal&Glass-Seal I i
4 Nail Pattern (Non-HVHZ only)
,i
.i
NAILS
i Nailing __ 6-7/611
MM ........ .. ..... _ _ ......_ ..... II
5-118"
I
Butt Edge
Figure 2. Elite Glass-Seal&Glass-Seal
6 Nail Pattern
i
T131315001.2 FL18355-R2 Page.3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3.IThe manufacturek shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein. 1
i II' a
i
TAMKO BUILDING PRODUCTS
CRE I 'Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage® Basic Wind Speed(Vut): Max. 194 mph
(Dallas, Frederick,Joplin, Basic Wind Speed(Vasd): Max. 150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC re,gturements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Heritage®Premium new construction; Min. 15/32'; in. plywood existing
(Dallas, Frederick construction.
Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; ,i
& Solidly sheathed min. 15/32 in. plywood 0.�wood plank for
Heritage@Woodgate new construction; Min.7/16 in.OSB existing construction.
(Dallas&Frederick) Underlayment: In accordance with FBC requirements.
Min.slope; 2:12 and in accordance with FBC!1'requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .1
Installation(HVHZ): Installed with 5-5/8 in. exposure in;accordance with RAS
115 and manufacturer's published'installation instructions.
Shingles shall be attached using ''6 Nail"Pattern" detailed
below. I ;,
Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Pattern"detailed,below.i
I�
I
I IL
FASTENERSNAIL ZON E
i
COMMON
;BOND
FEX60SU
RE 6-518"
12-112" 12-318" -► - 12-1/2'
Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate,(Dallas)
4 Nail Pattern (non-HVHZ only)
FASTENERS NAIL ZONE
COMMON
I BOND;
Ell
SURE 3-5/8"
1'=►I h-7-112'-►�+I-7-1/2"-►�+ll- 7-318"-�1-7-i f2"-�-7-1/2"-�l �f-1";
Figure 4. Heritage®& Heritage®Premium) I' u
6 Nail Pattern
TBP15001.2' FL18355-R2 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. IThe manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duratiori for which this report is valid.
This evaluation report does not.express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed:herein.
4
I
I
TAO BUILDING PRODUCTS
CREEK Asphalt
Shingles
TECHNICAL SERVICES,LLC l
NAIL ZONE!
ASl'ENERS
GOmmoN i36ND
' I i
-1!$" T i
;[ EXPOSUREf 5518" ! ;!
1'" �1.7.1I2=�-7-1�2'�►�t7-318=1►�1-7=1/2�7r1/�u1►I �1=1" � ' r
Figure 5. Heritage®Woodgate
6 Nail Pattern
��1"ii°i+ 12=112" ► i<--12-1/2"'-
t ° ( Common Bond
FASTENERS
J
'Z
\ I
�a r
39-3/8" i
j Figure 6. Heritage®, Heritage®Premium,&Heritage6 Woodgate
Alternate 6 Nail Pattern
PAINT
CINE. i
7-7I8" ; --------:-_...._.-•------•-••-_----_....__..-........_....-•-------_.--_----•--- I�---•----..�-N ZONE
AIL.
r II
t: OF..
i, ; COMMON
BOND
EXPO
5-5/81,,SURE,
t I
i
ACCEPTABLE, , I
FASTENER LOCATION f
D O NOT FASTEN.
ALONG`EDGE OF
- - - - - COMMONr'BOND I; f
PREFERRED
FASTENER ;I
LOCATION
Figure 7. Heritage@(Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3,4,and 6 may be placed in the nail zone asdescribed above
I'
TBP15001.2 FL18355-R2 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer�shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the�lduration'for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
r
i
I,
i
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage®Premium Basic Wind Speed(Vut): Max. 194 mph
(Frederick) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min., 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed..min. 15/32 in. plywood er wood plank for
new construction;Min.7/16 in.OSB'existing construction.
Underlayment: In accordance with-FBC requirements.
Min.slope: 2:12 and in accordance with FBC;requirements. Refer to
the manufacturer's application instruction's when installing
shingles at slopes greaterithan 21:,12. .
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published ;installation instructions.
Shingles shall be attached using""6 Nail(Pattern" detailed
below.
Installation (.Non-HVHZ): Installed with 6 in. exposure in,' -accordance with FBC
requirements and manufacturer's. published installation
instructions. Shingles shall be attached using either"4 Nail
Pattern"or"6 Nail Patterol'detailed below.lj
i
I
NAIL ZONE/
FASTENERS COMMON BOND
i,
511211 EXPOSURE 5"
1"-►I -- 11"-►�--- 12"
Figure 8. Heritage®Premium(Frederick)
4 Nail Pattern (non-HVHZ only) i
NAIL ZONE/
FASTENERS COMN16N BOND
II IE II
5112" EXPO U E 5"
�n
[1l9'/2'+V+— 9u 3n 9112" 4--11 h
Figure 9. Heritage®.Premium (Frederick), it
6 Nail Pattern f'
I ;
TBP15001.2 FL18355-R2 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61020-3.;The manufacturer.shall notify CREEK
Technical Services,.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
III I
i
i
I 1
TAM.KO BUILDING PRODUCTS
CREEKAsphalt Shingles
TI=CHNICAL SERVICES,LLC
Heritage®Woodgate Basic Wind Speed(Vut): Max. 194 mph
(Frederick) Basic Wind Speed(Vam): Max. 150 mph l e
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/116 in.OSB existing construction.
Underlayment: In accordance with FBC requirements. w
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instruction's when installing
shingles at slopes greater'than 21:0.
Installation (Non-HVHZ): Installed with 5 in. exposure in ,accordance with FBC
requirements and manufacturers; published installation
instructions. Shingles shall be attached using either'A Nail
Pattern"or"6 Nail Pattern'detailed below:'
, I
i
NAILIONE/�'
FASTENERS COMMON BOND
II
i
5-U2" EXPOSURE 5'111'
i'
11" 12-3/8"—I►�I— 11"
Figure 10. Heritage®Woodgate(Frederick) II
4 Nail Pattern (non-HVHZ only)
P
j
NAIL ZON E1
COMMON BOND
FASTENERS ; , f
C yt
J'11f.1. I i
j1EXPOSURE 5j
I
9-1/2" 1"
!' I
Figure 11. Heritage®Woodgate(Frederick)
6 Nail Pattern ! {
I
I
,I
I
I
TBP15001.2 Fl-18355-R2 I Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. iThe manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
I ,
' I I
'I
i
S�
TAMKO BUILDING.PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES,LLC
Heritage@ Vintage® Basic Wind Speed(V,fl1): Max. 194 mph
(Phillipsburg) Basic Wind Speed Msd): Max. 150 mph
Deck(HVHZ): In,accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Mina 15/32; in. plywood existing
construction. "
Deck(Non-HVHZ): In accordance with FBC r Iquirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/1b in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBCrequirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater'than 21:'12.
Installation HVHZ : Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using!'"6 Nail!Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with. FBC
i requirements and manufacturers' published installation
instructions. Shingles shall'be attached using either"5 Nail
Pattern"or"6 Nail Pattern"detailed below!
' N max aposure i
T -9 t��ma z Rb0•h ;
t Fastener � I'
6" I! tV3il In
II
orp
1 T•112"
Exposure
�+---la?M•� �+—lama"—+{
d
Figure 12. Heritage®Vintage.®
5 Nail Pattern (non-HVHZ only)
�O' E7R10117R '
Notch
A
$
6. F3steneis
NOV
Zone
17-V X. j
7-]Ar--�-757/!'
_I 1,
Figure 13. 'Heritage®Vintage'
6 Nail Pattern_
TBP15001.2 FI-18355-R2 ! Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,.installation,recommended use,or other product attributes that are not
specifically addressed herein.
I � ;
I ,
� i
i
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC l'
Hip&Ridge Basic Wind Speed(Vut): Max. 194 mph I
(Frederick&Joplin) Basic Wind Speed W.,d): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/,32 in. plywood or wood plank for
new construction; Min.j 15/32, in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15132 in, plywood or wood plank for
new construction;Min.7116 in.OSB existing construction.
Underlayment: In accordance with FBC requirements. "'
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall lie away from the
prevailing wind. it
Directio4n of prevailing wind
Start 5-1/8" exposure
here—
Start
here
Figure 1 5-1/8"exposure
�' 11
•+ 11"
5 - `,- ;I fl
? Fastener Faste0er
Figure 2 1,4» Figure 3 li .
Figure 14. Hip&Ridge(Frederick&Joplin)
j
,
�I
� I
i
! TBP15001.2' FL18355-R2 Page.9 of 11
This evaluation report is provided for State of Florida:product approval under Rule 61020-3. IThe manufacturet•shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed;herein. it
I .
I '
CREEK
TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
i
Vintage@ Hip&Ridge Basic Wind Speed(V,dt): Max.194 mph
(Phillipsburg) Basic Wind Speed Msd): Max. 150 mph
Deck(HVHZ); In accordance with FBC requirements; J
Solidly sheathed min. 19/32 in. plywood Or wood plank for
new construction; Min. 15/32 .in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements; 1
Solidly sheathed min. 15/.,32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements. Ij
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation'instructions. The
direction of the exposed end shall be' away from the
prevailing wind. j I;
I p II
Direction of prevailing wind
r ,
tart �5.,;' exposure I '
re-
Fn
Start91'11
here
Figure 1 5" exposure
lot
5 DFF�-L'�
Fastenertener'
�5-1/2" r `5-1/2,
i
I
1/4"
Figure 2 Figure!3
I ,
j Figure 15. Vintage®Hip&Ridge(Phillipsburg)
I j
ii
I '
I
I I i
i
i
TBP15001.2 FL18355-R2 Page 10 of 11
This evaluation report is provided for State of Florida product approval under.Rule 61 G20-3. IThe manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
I
it F
' 1
I
' I
R® TAMKO BUILDING PRODUCTS
EEK I Asphalt Shingles
TECHNICAL SERVICES,LLC
I
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and.cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D7158 applies to exposure'B&C with a building mean roof height of 33-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities anddebris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment applicaltion.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, 'and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
i and code compliant detail shall prevail. l `
8) All products listed in this report,shall'be manufactured under a quality assurance program it compliance with
Rule 61620-3.
I '
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance,with the Florida Building
Code 5t'Edition(2014)as evidenced in the referenced documents submitted by the Named manufacturer.
,`�G�PFtY R p,c?�,,,, 2015.12.14
'
No 24021 13:44:19
�
05'1 .
3 STATE OF .:�4t]
T%• 'c P •'��` Zachary R. Priest,P:E.
R V'-"C?N � Florida Registration ,o.74021'
A,E ��� Organization No.ANE9641
'it
I II
CERTIFICATION OF INDEPENDENCE
CREEKTechnical Services,LLC does not have,nor will it acquire,a financial interest in any cl mpany manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation. j
� I
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved inithe approval process of the
product.
I '
II
,I I
i
END OF REPORT
TBP15001.2 FL18355-R2 Page 11 of.11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration'for whicl this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
a
I
9/24/2015 Florida Building Code Online
Florida Departmentd BCIS Home ? Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications ! FBC Staff i i BCIS Site Map Links Search y
Business; gjjj
Product
PCOfeSSI naI USER:PubliccUProval
Regulation
Product Approval Menu>Product or ADDlicatlon Search>Application List>Application Detail
i
FL# FL10758-R6
Application Type Revision
I
Code Version 2014
Application Status Approved
U
Comments }
Archived I
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkwaly
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
,I
Authorized Signature Greg Keeler
greg.keeler@owenscorning,com l
Technical Representative Greg Keeler ! i
Address/Phone/Email 2790 Columbus Road li
Granville, OH 43023 !
(740)321-6345
greg.keeler@owenscorning.com
! Quality Assurance Representative li
Address/Phone/Email i.
i
l
Category Roofing l
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered'lArchitect or a Licensed
Florida Professional Engineer 14'
I Evaluation Report-Ha'rdcopy Received '
it ' it
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity Miami-Dade BCCO-QUA
Quality Assurance Contract Expiration Date 04/13/2018
Validated By Locke Bowden
Validation Checklist- Hardcopy:Received
I
Certificate of Independence FL10758 R6 COI CR14063 2 2014IFBC noniHVHZ Evaluation Report
Owens Cornina Vents 060514.pdf ; !'
i
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1709.2
hops://foridabuilding.org/pr/Pr_app dtl.aspx?param=wGEVXQwtDgvldAvlteOY0%2bC3zFtrydg9ubWMrxzLHkv1rEPVYDHgEQp/o3d%3d 1/2
i
I�
i I
I
9124/2015 Florida Building Code Online i
i
Product Approval Method Method 2 Option B
i
Date Submitted 02/23/2015
Date Validated 02/24/2015 i
Date Pending FBC Approval 03/01/2015 {I
Date Approved 04/15/2015
Summary of Products
I '
FL# Model,Number or Name Description I it
10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic`ridge vents for installation
Moisture Ridge Vents in shingle roof systems ! '
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10758 R6 II 6CR14003.2 201JFBC nonHVHZ Evaluation
Approved for use outside HVHZ:Yes Report Owens Cdrning Vents 060514.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other: Refer to evaluation report Evaluation Reports ( y
FL10758 R6 AEIIOCR14003.2 2014 FBC nonHVHZ Evaluation
Report Owens COrninO Veilts 060514.pdf
Created by Independent Third Party: Yes
u r
10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent
Roof Vent With Exterior Louver I i'
I d ' is
Limits of Use Installation Instruction's I4
Approved for use in HVHZ:No FL10756 R6 II IOCR1400'3.2 20141FBC nonHVHZ Evaluation
Approved for use outside HVHZ:Yes Report Owens Cornina Vents 060514.Ddf
Impact Resistant: N/A Verified By: Zachary R, Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to evaluation report. Evaluation Reports
FL10758 R6 AEIOCR14003.2 2014 FBC nonHVHZ Evaluation
e ort Owens C6rnlnq Vdhts 0 0514. df
reated by Independent Third Party: Yes
10758.3 VentSure Rigid Roll Ridge Vent Aidge Ventilation System-i j
Limits of Use Installation Instructions
Approved for use HVHZ: No FL30758 R6 II 1OCR14003:'2 2014:FBC nonHVHZ Evaluation
Approved for use o ide HVHZ:Yes Resort Owens Cornino Vents 060514.pdf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:Refer to evaluation report. Evaluation Reports
FL10758 R6 AEI OCR14003.2 2014 FBC nonHVHZ Evaluation
Report Owens Cornina Vents 060514.12df
Created by Independent;Third Party: Yes
I
• kkoc6c Next ' ��
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Staten ::Accessibility Statement::Refund Statement
I'
Under Florida law,email addresses are public records.If you do not want your e-mail address released I Ilresponse tda'public-reicords request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please;contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must'provide the Department with an email address If they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here. I ,' I
Product Approval Accepts:
SCCUYItY}ILY'RtCa i I a
i I
i
I
I. �I
i
;I
' f
I
i
i
https://fioridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgv1dAvlteOYO%2bC3zFtrydg9ubWMrxzLHkv1rEPVYDH9EQ%3d%3d 2/2
I.
N 1W Certificate of Authorization No.29824
CREEM17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
0
EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23, 2015
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465
www.owenscornino.com I
Manufacturing Plants: Rohnert Park, CA;Orrick, MO; Baldwyn, MS; Niles,OH ! j
I I
Quality Assurance: Miami-Dade BCCO—QUA(QUA1591) 1
SCOPE
Category: Roofing Ij
Subcategory: Roofing Accessories that are an Integral Part of the Roofing System it
Code Sections: 1709.2
Properties: Roof Ventilation
REFERENCES I
it ; II
Entity Report No. Standard ;I ; Year
Architectural Testing,Inc(TST1558) 01-38660.04 TASiI100(A) II 1;995
i Architectural Testing,Inc(TST1568) 01-38660.05 TAS i100(A) i! 1y995
Architectural Testing,Inc(TST1558) C1774.01-109-18 TAS I110
1,995
ASTM D 635', 2006
I ASTM D 19291 2001e01
i ASTM D 2843; 2004e01
PRI Construction Materials Technologies(TST5878) AVIG-005-02-01 ASTM D 635 i 2006
ASTM D 1929, ; 2001e01
ASTM D 2843 2004e01
PRI Construction Materials Technologies(TST5878) AVIG-006-02-01 ASTM G 155 1, 2005a
PRI Construction Materials Technologies(TST5878) OCF-111-02-01 ASTM D 635;i , 2006
ASTM D 1929 2001 e01
ASTM D 2843, 2004e01
PRI Construction Materials Technologies(TST5878) OCF-112-02-01 ASTM G 15511 2005a
PRI Construction Materials Technologies(TST5878) OCF-116-02-01 TAS' 10(A) 1, ' 1;995
PRI Construction Materials Technologies(TST5878) OCF-223-02-01 TASi1110(A) II 1995
PRI Construction Materials Technologies(TST5878) OHI-007-02-01 TAS,100(A) ;! 1;1995
PRODUCT DESCRIPTION AND APPLICATION ji I
I� I, I!
VentSure• 4-Foot Strip 1-1/4" x 14-7/8" x 48" low-:profile attic ridge vent consisting'of a two-layer nylon-
Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for
Vents: installation in shingle roof systems.
48"
t ,
I -
14-7/8"
OCR14003.2 FL10758-R6 !I I' h Page 1 of
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3.;IThe mariufactur&shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration"for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
I specifically addressed herein. I;
' I I
I
I. d
,I
I
OWENS CORNING ROOFING AND ASPHALT LLC
C
j VentSurem Roof Ventilation
oft-REE". I
TECHNICAL SERVICES, LLC
I .I
Deck Type: Roof deck shall be constructed of closely fitted sheathing;for new or existing
construction. Roof deck shall be designedand instialled inilaccordnce with FBC
requirements. ;i
Roof slope: Minimum 3:12 to maximum 16/12 11
Installation Height: Maximum 60-ft I
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 6-inches from the rake
edges. Apply a %-inch wide bead of ASTM D 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga.2%-inch galvanized ring shank nails
(shall comply'with FBC Section 1506.5) provided with!the vent.' Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 4�7-inches from the start of each
vent piece. i
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section. Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga. 2%-inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) prvided with'the vent or as directed by the
shingle manufacturer's installation instructions. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles ! I!
VentSuree'Low Profile . 18"x 24°x 2-3/16"(32°x 23"flange base)static off-ridge ventjcomposed of ASTM
Slant Back Roof Vent A653 galvanized steel(available with painted finish). ,Material'shall conform with
with Exterior Louver: FBC Section 150.7.4.31. I }
dtxRHT " �
Ll
I '
i f
�.
r _t
ZEDUT -+h
IT r
I i
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed ini'accordance with FBC
requirements.
OCR14003.2 FL10758-R6I Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3._I1The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
! specifically addressed herein. it
, II
' it
I
I
i
OWENS CORNING ROOFING AND ASPHALT LLC
d' VentSure®Roof Ventilation
Uml.* EK
i�
TECHNICAL SERVICES, LLC '
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft I
Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately p-inches from
the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM p'4586 roofing cement
around inner and outer flange. Place vent directly over the Able, ensuring the vent
sits flat on the roof. Fasten vent 4-inches o.c,and 1-inch from:loutsidej edge of flange
with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per
vent). ;f j
� 1
Install baffle in %-inch bed of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with;I:FBC Section 1506.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring 1,inch penetration through
wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement.
' Allowable Roof Coverings: Asphalt shingles , '
�I l
I VentSure"Rigid Roll 5/8"x 11-1/4"x 20'attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun-bond polypropylene fabric. I'
i
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in laccordance with FBC
requirements.
I
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft it
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 12;inches from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to thelfield shfingles. Center
the vent over the opening, and fasten the vent 241 finches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall coply withi�FBC Section 1506.5),
ensuring%-inch penetration through wood deck. I;
Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails(shall comply with FBC Section
1506.5) or as directed by the shingle manufacturer's in'stallatio'n instructions,
ensuring%-inch penetration through wood deck. Outside edges' of the shingles shall
be sealed with flashing cement. i4
ii
Allowable Roof Coverings: Asphalt shingles
OCR14003.2 FL10758-R6 d
I �, ` ;i Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3.liThe manufacturer:,shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration,for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein. it
i
i
I I
i
OWENS CORNING ROOFING AND ASPHALT LLC
VentSure®Roof Ventilation
CKEEK
I
!,
TECHNICAL SERVICES, LLC
I
LIMITATIONS !�
1) Fire Classification is outside the scope of this evaluation.
2) This report is not for use in the HVHZ.
3) The roof deck and deck attachment shall be designed by others in accordance withlit a 20114 FBC.
4) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3. IIII : !I
5) Owens Corning vents shall be installed in strict compliance with Ithis evaluation] report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shall be enforced.
6) Deck substrates shall be clean, dry, and free from any irregularities and(debris. All fasteners in the deck
shall be checked for protrusion prior to installation. l
7) Installation of the roof assembly is outside the scope of this evaluation.
8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications. I
I
COMPLIANCE STATEMENT I I'
I
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with ;the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
' I
,,���►„�.►�,,,,, ' 2015 02 2
R. .
.�,G E N 314:48:59
No 74021
. _ I
* _051001
0'.� STATE 0 F :��/ I'
.0 AI O r ����` Zachary R. Priest, PI.E.
�i,�ss, •........ �C?�.` Florida Registration No.74021
% Organization No.AKE9641 it
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation. I
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
� Ih
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation. I
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. t
I' i
i
END OF REPORT I
f
OCR14003.2 FL10758-R6 ;• Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which'his report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
� it
I
6/30/2015 Florida Building Code Online
i�
no
M.
Florida Lepar(II1ent?r BCIS Home Log In User Registration Hot Topics Submit Surcharge € Stats&Facts 1 Publications ' FBC Staff 1`II BCIS Slte Map ! Links ' ' !Search ;
Busines ) '
I '
" s 'Product Approval �r
Professi -�I USER:Public User
Regulation
Product Aooroval Menu>Product or Application Search>Aoolication List>Application Detail I I• �
I
FL# FL2569-R9
Application Type Revision Q
Code Version 2014
Application Status, Approved
Comments I f'
i 4
Archived II '
Product Manufacturer Soprema, Inc. (Canada) I
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000 !
(819)478-2400 Ext 3327
I
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
I' P
! Technical Representative Marc-Etienne Mathieu I,
Address/Phone/Email 1688 Jean-Berchmans-Michaud `
Drummondville, NON-US 00000
(819)478-2400 Ext 3327 I'
imemathieu@soprema.ca
I.
Quality Assurance Representative Jean-Francois Cote, Ph.D. I
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Category Roofing '•I i
Subcategory Underlayments II III
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Ha�dcopy Received j
6•,
Florida Engineer or Architect Name who developed Robert J. M. Nieminen it
the Evaluation Report I
Florida License PE-59166 I I
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy,Received
Certificate of Independence FL2569 R9 COI 2015 01 COI Niemlinen.Ddfl
Referenced Standard and Year(of Standard) Standard I, Year
ASTM D1970 I 2009
ASTM D6163 2000
I ASTM D6164 2005
FM 4474 I 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 I i1 1995
I 1'',
haps://floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xYIX2%2f%2bLT9p188%3d 1/2
i p
a _
6/30/2015 Florida Building Code Online
TAS 110 2000
I
Equivalence of Product Standards
Certified By
'I 4
Sections from the Code-
i
e
r '
Product Approval Method Method 1 Option D I�
� I
Date Submitted 04/17/2015
Date Validated 04/21/2015
Date Pending FBC Approval 04/25/2015 '
I Date Approved 06/23/2015
Date Revised 06/29/2015 a
6 I.
Summary of Products
FL# Model,Number or Name Description -
I
2569.1 Soprema Roof Self adhering roof underlayment's L.
Underlayments ..... ;I
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R9 II 2015 04 FINAL ER SOPREMA CA�UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R9.12df �I
Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-90 Created by Independent Third Party: Yes
i Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reportsij
Use. 2.)The design pressure noted herein FL2569 R9 AE 2015 04 FINALI ER SOPREMA CA' UNDERLAYMENTS FL2569-
pertains to underlayment systems used R9.Ddf
beneath adhesive-set tile systems. Refer to Created by Independent Third Party: Yes .
ER Section 5.6.4 for details.
'dacEr Kid I it
f'
I o
contact us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 II
II
The State of Florida is an AA/EEO employer.Copydaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released Inlresponse to'la,public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850:487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must$rovide the;Department with an email address if they have.
one.The emails provided may be used for official communication with the licensee.However email addresses arel'pliblic record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.Td determineIf you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts: i
I i•
I
I
I � P
I 1
i
`I
I I'
lel
I 91
I i
https://floridabuilding.org/pr/pr_app U.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xYIX2%2f%2bLT9pl88%3d 2/2
' I i�
a!•e _ sd� III„
I
I
I
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
ERD
353 CHRISTIAN STREET,UNIT#13
1 ' Et\ OXFORD,CT 06478
PHONE:(203)262-9245
i FAX:(203)262-9243
EVALUATION REPORT I it
Soprema,Inc. 'Evaluation Report S18010.06.09-R7
1640 rue Haggerty FL2569-R9
Drummondville,Quebec J2C 5138 Date of Issuance:06/15/2009
Canada ! Revision 7:04/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations(governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewedl by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code; Residential Volume. The
products described herein have been evaluated for compliance with the 5 thEdition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to tNe product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.Eli if the product changes or the
referenced Quality Assurance documentation changes. Trinity]ERD requires a comrlete review of'his Evaluation Report
relative to updated Code requirements with each Code Cycle. !i li
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity]ERD Evaluated"1 may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall.be done in its erntirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the BuildingOfficial.
This Evaluation Report consists of pages 1 through 6.
I
Prepared by: i
0.1.-S-,�s_ .
i pi, ,� A. The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E. �7l�FS �»�Cr. �` P•E.on04/17/2015.This does notserve asanelectronically signed
Florida Registration No.59166,Florida DCA ANE1983 e..�,,J�I�N'a\ �.s document.Signed;sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE: II
1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any companyl manufacturing ori distributing products for
which the evaluation reports are being issued. !1 II • it
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen,•P.E. are, in any way,-'the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used.for permlittinar o I r design guidance unless retained
specifically for that purpose.
f
II i it
9
II
I
I'
T.INI` `Y ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following
sections of the Florida Building Code through testing in accordance with the following Standards . Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
I ' '
Section Property Standard I II Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 ) 2009
1507.4.5.1,1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 d 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 1 2000
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) !i 2012
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2' 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-Rl 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10!1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion Si1150.O5.101R1 09/09/2010
ERD(T5T6049) Physical Properties/Tensile Adhesion S11150.05.091R2 'i 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.111 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.1341 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.141 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645!02.15 ,; 11 02/13/2015
ERD(TST6049) Physical Properties/Accelerated Weathering SOPC-SC85201114 04/17/2015
M-D(CER1592) HVHZ Compliance 09-1005.02 �; 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 ! 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 11 12/03/2013
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
F
4.1 Lastobond TU HT is a self-adhering,non-woven polyester fabric surfaced,SBS modified bitumen roof underlayment.
4.2 Lastobond Shield is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available
in two widths;36 and 45 inch.
4.3 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.4 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch.
4.5 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment.
4.6 Lastobond 195 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
4.7 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roofunderlayment.
4.8 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment.
Exterior Research and Design,LLC. 1 Evaluation Report S18010.06.09-R7
CertWcate of Authorization#9503 I FL2569-R9
Revision 7:04/17/2015
j Page 2 of 6
IT.RRINITY!
ERD
4.9 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBSimodified bitumen roof
underlayment. ! !
4.10 Resisto LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with
a 36-inch sheet width.
4.11 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment,with a 36-inch sheet width.
4.12 Resisto LB1244 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified,bitumenl roof underlayment,with
a 44-inch sheet width.
4.13 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment.
4.14 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
t
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert 1 i 1 len, P.E.;;are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose. i i
5.2 This Evaluation Report is not for use in the HVHZ. ii
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the,product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for,approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows: i.
1TABLET:-ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate
Shingles Shingles
Lastobond TU HT Yes Yes YesI Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N Yes No No it I No ii Yes Yes
Lastobond Shield HT/Pro HT-S Yes No No Yes` Yes Yes
Lastobond/Lastobond 195 Yes No No j No Yes Yes
Lastobond ECO /Resisto LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No Ni.. Yes Yes
Resisto LB1244 ;i .
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Ye
Colphene FR GR Yes Yes See 555.1 No Yes Yes
i
Unilay(e) Yes Yes Yes I No No No
Batten Only See 5.5.1 li
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion /long term aging data from an
accredited testing laboratory is provided.
Underlayment Adhesive(s)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond'"Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
i
Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569-139
Revision 7:04/17/2015
Page 3 of 6
I '
I
I '
IV
TRINITYJ ERD
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT or Lastobond IPro HT-Slapplied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, Resisto LB1236, Grip-Rite I.Eave & Valley Protector,
Resisto LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM 1)41'pHmed structural concrete.
l
Colphene FR GR applied to:
➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
I i
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema rJ commends priming with
Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue-and-groove board decking be covered withlywoodlor OSB prior to installation of the
self-adhering underlayment.
i
5.6.2 Bond-to-Insulation: i, I
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond!Pro HT-S or Colphene FR
GR applied to:
➢ DensDeck DuraGuard;DensDeck Prime;SECUROCK Gypsum-Fiber Rol Board.
For installation under mechanically attached prepared roof coverings, insulatiori'shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4474,,Appendix D or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver: ;� ;I, �i
I
Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT,Lastobond Pro HT-S orColphere FR GR applied to:
➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. !i
For installations under mechanically attached prepared roof coverings, baselayer shall Up attached per minimum
codified requirements. For installations under foam-on the systems,base layer shall be attached in accordance with
FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
i
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlaym int systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications:, Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,,and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBG 1504.9 has already been applied ).i Refer to FBC 1609 for
determination of design wind pressures. it
5.6.4.1 Maximum Design Pressure=-45.0 psf. I
Deck. Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 600c
Underlayment: Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf. ;I
Deck: Structural concrete to meet project requirements to satisfaction of AHJll
Primer: Elastocol 600c
' Underlayment: Colphene FR GR,self-adhered. i
lu
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached'with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in, three,equally spaced rows in the
center of the sheet.
Underlayment: Colphene FR GR,self-adhered
it
Exterior Research and Design,LLC: Evaluation Report 518010.06.09-R7
j Certificate of Authorization 719503 t FL2569-R9
iI Revision 7:04/17/2015
Page 4 of 6
�I
i
II
I
t I �
I
i I i� it
ERD
TRINITY'
5.6.4.4 Maximum Design Pressure=-90.0 psf. I
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Ba'r(PBB)�or Soprafix Metal Batten
Bar (MBB),with Soprema #15-EL fasteners spaced 16-inch o.c. within the 5-inch wide, self-
adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air
welding techniques.
5.7 Exposure Limitations:
5.7.1 Lastobond Shield,Lastobond Pro HT-N,Lastobond,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Resisto
LB1236,Grip-Rite Eave&Valley Protector or Resisto LB1244 shall not be'left exposed for longer than 30-days after
' I I'
installation, I, {
5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than,90-days'after installation.
1 1
5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer;lthan 180-days after installation.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published i'stallation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below i
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick,or Elastocol 600c.(if applicable).
i
6_3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT.(Lastobond Pro HT-S, Lastobond
Lastobond'195. Lastobond Eco: Lastobond Smooth Seal HT. Resisto LB1236 Grip'-Rite Eave & Valley Protector
Resisto LB1244 or Colphene FR GR: 1�
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
i1
While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 6'c if the final roof cover
is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and'peel back the first 3 ft of release
film.
Adhere the exposed part to the substrate and unroll the remaining membralne as far'as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally whiler,holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical 'seams,, hould be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using
either heat-welding or hot air welding techniques. �I !
When installing at slopes above 8:12,Soprema recommends back-nailing im the overlap area at the top of the sheet
at 12-inch o.c. !i
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge.Drape and press-sheet into place,working from the center of the valley or ridge in each direction. For
valleys,apply the sheet starting at the lowest point and work upward.
I,
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to+RSA/TRI April 2012 (04-12) Installation Manual and Table Wherein; using the instructions
noted above as a guideline. f'
For Colphene FR GR in foam-on tile applications, reference is made to Section 5:6.4 herein for wind resistance
limitations.
�
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damageIf to the underlayment.
� a
P
II
Exterior Research and Design,I.I.C.
Evaluation Report 518010.06.09-R7
Certificate of Authorization#9503 FL2569-R9
Revision 7:04/17/2015
y' Page 5 of 6
�I
i
i
y
I �
i
i
I ITYER®
6_4 Unila e : II
6.4.1 Non-Tile Applications or Nail-On.Battened Tile Applications: �I j
Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if!applicable).
I
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach
` the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap nails spaced 36-inch o.c. Apply
ithe second course in a water-shedding manner with self-adhering sidellaps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-"inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile (if applicable) shall be loaded and staged in a manner that prevents tile;slippage and/or damage to the
underlayment. � ;' I
6.4.2 Foam-On Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and jTable 1 hip rein.
II il ' I
Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach
the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar
(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c. Apply the second courseiin a water-shedding manner with
self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a
watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-
granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents tile slippage and or damage to the underlayment.
I i
7. BUILDING PERMIT REQUIREMENTS: II
As required by the Building Official or Authority Having Jurisdiction in order top evaluat,the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule161G20-3 OA requirements.
9. QUALITY ASSURANCE.ENTITY:
I'
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT- j
i
II
I'
i
i
i
I
� !I
I ' I
I
I
i
! I
Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-R7
Certificate oJAuthorizotion 19503 FL2569-R9
Revision 7:04/17/2015
Page 6 of 6
'i
I
'I
-0M imNvoo out Mi
Rzo Howl KH
04
r .w
1 k
BCIS Home Log In j User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map j Links Search i
FI rich
Product Approval
' USER:Public User
Product Aooroval Menu>Product or Aoolication Search>Application List>Application Detail r
9 � FL# FL18355-R2
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
1.
Product Manufacturer TAMKO Building Products, IhC.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com I'
Authorized Signature Kerri Eden
kerri_eden@tamko.com
'I
j Technical Representative
Address/Phone/Email
Quality Assurance Representative
i
Address/Phone/Email
Category Roofing ii
Subcategory Asphalt Shingles
1 i
l�
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
Validation Checklist-Hardcopy.Received
Certificate of Independence FL18355 RZ COI TBP15001 2 FBC 2014 Product Evaluation Report
Shinales.odf
1' I
ll
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3161 2009
ASTM D 3462 2009
ASTMD D 7158 I 2008
I TAS 100 'I 1995
Equivalence of Product Standards 'I
Certified By
Sections from the Code
I
Product Approval Method Method 1 Option D
Date Submitted12/16/2015
Date Validated 12/18/2015
Date Pending FBC Approval 12/19/2015
Date Approved 02/10/2016
Date Revised 05/09/2017 l'
Summary of Products p til
FL# Model,Number or Name Description ,
18355.1 Glass-Seal, Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Heritage Premium,
Heritage Woodgate, Heritage i
Vintage, Hip and Ridge, and Vintage
Hip and Ridge Shingles
Limits of Use Installation Instructions 10
Approved for use in HVHZ:Yes FL18355 R2 1I TBP15001.2 FBC 2014 Product Evaluation
Approved for use outside HVHZ:Yes Report Shinales.bdif
Impact Resistant: N/A Verified By: Zachary R. Priest PE;74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL18355 R2 AEITBP15001.2 FBC614 Product Evaluation
Report Shingles.'odf
Created by Independent Third Party: Yes
S4ack Next � i, �,
i
I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phol e:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
i'
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must 1provide thelDepartment with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available tolihe public.To determine if you are a licensee under Chapter
455,F.S.,please clicke e.
Product ApprovalAccepts: it
I
Credit Card
Safe
i
I
I
'I
l
Certificate of Authorization No.29824
CCRIEEK175,20 Edinburgh Dr
r
Tampa,FL 33647
TECHNICAL SIERVICFS, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5TH EDITION(2014)
Manufacturer: TAMKO BUILDING PRODUCTS Issued December 14, 2015
220 West 4"'Street 11 .
Joplin,MO 64801
(417)624-6644 r
Manufacturing Plants: Joplin, MO
Phillipsburg,KS
Frederick,MD
Dallas,TX
Tuscaloosa,AL
Quality Assurance: UL LLC(QUA9625)
SCOPE
.Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 1100 1995
PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS-100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 1100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 1100 1995
PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-1'30-02-01 TAS 1100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 1, 1995
PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS'100 1995
PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS1100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 63811• 2008(2013)e1
PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TASI�00 1995
UL LLC(TST9628) 02NK9507 ASTM D 3161, 2009
UL LLC(TST9628) 04NK24366 ASTM D 3462 2009
UL LLC.(TST9628) 05NK28006 ASTM D 63811 2008(2013)e1
UL 2390 1'
ASTM D 7158 2008d
UL LLC(TST9628) 06NK03898 ASTM D 3161f 2009
ASTM D 3462 2009
UL LLC(TST9628) 08CA59132 ASTM D 3161 2009
UL LLC(TST9628) 09NK07896 ASTM D 3161• 2009
ASTM D 3462- 2009
UL LLC(TST9628) 1OCA50498 ASTM D 3462 2'009
UL LLC(TST9628) 10CA64882 ASTM D 3161 2009
UL LLC(TST9628) 11NK14014 ASTM D 3161; 2009
ASTM D 3462 - 2009
UL LLC(TST9628) 12CA24551 ASTM D 3161 2009
UL LLC(TST9628) 4786110543 ASTM D 6381, 2008(2013)e1
UL LLC(TST9628) 4787043752 ASTM D 3161' 2009
UL LLC(TST9628) 4787148748 ASTM D 7158 2008d
ASTM D 3161 2009
ASTM D 3462 2009
I
TBP15001:2 FL18355-R2 I Page 1 of 11
This evaluation reportis provided for State of Florida product approval under Rule 61G20-3. jThe manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration,for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein. I i,
i