HomeMy WebLinkAboutProduct Approval TABUILDING PRODUCTS CREEK ,Asphalt Shingles TECHNICAL"SERVICES,LLC I PRODUCT DESCRIPTION ,I II Elite Glass-Seal® 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 34ab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass=Seal 12-1/4"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self:sealing, 3-tab (Frederick•& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36",ASTM D 7158, Class Hself-sealing, 3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-�HVHZ only. 4 Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle •surfaced ;with mineral granules Joplin,Phillipsburg& complying with ASTM D-3462. Tuscaloosa) Heritage®Premium 13-1/4" x. 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle !surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) 4 Heritage®Premium 12" x 36",,ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral 'granule's complying with ASTM D 3462. Heritage®Vintage® 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7118,Clasb+H fibelass reinforced , (Phillipsburg) laminated architectural asphalt shingle surfaced with lmineralir9granules complying with ASTM D 3462. Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and AS M D 7,,1.58, Class H fiberglass (Dallas&Frederick). reinforced, laminated architectural asphalt shingle surfacea with mineral granules complying with ASTM D 3462. Heritages Woodgate12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced,•laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with;ASTM D 3462. Shingles shall be used in the non-HVHZ only. i• ' Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick.&Joplin). shingle surfaced with mineral granules complying with'lASTM D.3462. Vinta e®Hi and Ride 12"x 12`', ASTM D 3161, Class F fiberglass reinford,d, hi I 9 p 9 g p and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP15001.2 FL18355-R2 Page.2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61020-3. jThe manufacturer shall notify CREEK Technical Services,.LLC of any product changes or quality assurance changes throughout the duration'for which this report is valid. This evaluation report-does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressedberein. ,I p .I i ii M I 'I TAMO BUILDING PRODUCTSCREEK As halt Shin les` TECHNICA_ SERVICES, LLC INSTALLATION Elite Glass-Seal® Basic Wind Speed(Vut): Max. 194 mph (Frederick,Joplin& Basic Wind Speed(Va,d): Max. 150 mph Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plyw'o'od or wood plank for Glass-Seal new construction; Min.11 15/32 d in. plywood existing (Frederick,Joplin(Non- construction. HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for tin new construction;Min.7/16 in.OSB.exisg construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FB& equirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-1/8 inch e'xposureilin accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail;Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-1/8-inch 61xposure';in accordance with FBC requirements and manufacturer's., published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or T Nail Pattern"detailed below. NAILS .1 �, min Iii i I I. Nailing G-718" Area _..... ......... ........_ .......:_ I. i Butt Edge Figure 1. Elite Glass-Seal&Glass-Seal I i 4 Nail Pattern (Non-HVHZ only) ,i .i NAILS i Nailing __ 6-7/611 MM ........ .. ..... _ _ ......_ ..... II 5-118" I Butt Edge Figure 2. Elite Glass-Seal&Glass-Seal 6 Nail Pattern i T131315001.2 FL18355-R2 Page.3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3.IThe manufacturek shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. 1 i II' a i TAMKO BUILDING PRODUCTS CRE I 'Asphalt Shingles TECHNICAL SERVICES,LLC Heritage® Basic Wind Speed(Vut): Max. 194 mph (Dallas, Frederick,Joplin, Basic Wind Speed(Vasd): Max. 150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC re,gturements; & Solidly sheathed min. 19/32 in. plywood or wood plank for Heritage®Premium new construction; Min. 15/32'; in. plywood existing (Dallas, Frederick construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; ,i & Solidly sheathed min. 15/32 in. plywood 0.�wood plank for Heritage@Woodgate new construction; Min.7/16 in.OSB existing construction. (Dallas&Frederick) Underlayment: In accordance with FBC requirements. Min.slope; 2:12 and in accordance with FBC!1'requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. .1 Installation(HVHZ): Installed with 5-5/8 in. exposure in;accordance with RAS 115 and manufacturer's published'installation instructions. Shingles shall be attached using ''6 Nail"Pattern" detailed below. I ;, Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed,below.i I� I I IL FASTENERSNAIL ZON E i COMMON ;BOND FEX60SU RE 6-518" 12-112" 12-318" -► - 12-1/2' Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate,(Dallas) 4 Nail Pattern (non-HVHZ only) FASTENERS NAIL ZONE COMMON I BOND; Ell SURE 3-5/8" 1'=►I h-7-112'-►�+I-7-1/2"-►�+ll- 7-318"-�1-7-i f2"-�-7-1/2"-�l �f-1"; Figure 4. Heritage®& Heritage®Premium) I' u 6 Nail Pattern TBP15001.2' FL18355-R2 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. IThe manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duratiori for which this report is valid. This evaluation report does not.express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed:herein. 4 I I TAO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERVICES,LLC l NAIL ZONE! ASl'ENERS GOmmoN i36ND ' I i -1!$" T i ;[ EXPOSUREf 5518" ! ;! 1'" �1.7.1I2=�-7-1�2'�►�t7-318=1►�1-7=1/2�7r1/�u1►I �1=1" � ' r Figure 5. Heritage®Woodgate 6 Nail Pattern ��1"ii°i+ 12=112" ► i<--12-1/2"'- t ° ( Common Bond FASTENERS J 'Z \ I �a r 39-3/8" i j Figure 6. Heritage®, Heritage®Premium,&Heritage6 Woodgate Alternate 6 Nail Pattern PAINT CINE. i 7-7I8" ; --------:-_...._.-•------•-••-_----_....__..-........_....-•-------_.--_----•--- I�---•----..�-N ZONE AIL. r II t: OF.. i, ; COMMON BOND EXPO 5-5/81,,SURE, t I i ACCEPTABLE, , I FASTENER LOCATION f D O NOT FASTEN. ALONG`EDGE OF - - - - - COMMONr'BOND I; f PREFERRED FASTENER ;I LOCATION Figure 7. Heritage@(Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3,4,and 6 may be placed in the nail zone asdescribed above I' TBP15001.2 FL18355-R2 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer�shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the�lduration'for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. r i I, i CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Heritage®Premium Basic Wind Speed(Vut): Max. 194 mph (Frederick) Basic Wind Speed(Vasd): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min., 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed..min. 15/32 in. plywood er wood plank for new construction;Min.7/16 in.OSB'existing construction. Underlayment: In accordance with-FBC requirements. Min.slope: 2:12 and in accordance with FBC;requirements. Refer to the manufacturer's application instruction's when installing shingles at slopes greaterithan 21:,12. . Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published ;installation instructions. Shingles shall be attached using""6 Nail(Pattern" detailed below. Installation (.Non-HVHZ): Installed with 6 in. exposure in,' -accordance with FBC requirements and manufacturer's. published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Patterol'detailed below.lj i I NAIL ZONE/ FASTENERS COMMON BOND i, 511211 EXPOSURE 5" 1"-►I -- 11"-►�--- 12" Figure 8. Heritage®Premium(Frederick) 4 Nail Pattern (non-HVHZ only) i NAIL ZONE/ FASTENERS COMN16N BOND II IE II 5112" EXPO U E 5" �n [1l­9'/2'+V+— 9u 3n 9112" 4--11 h Figure 9. Heritage®.Premium (Frederick), it 6 Nail Pattern f' I ; TBP15001.2 FL18355-R2 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61020-3.;The manufacturer.shall notify CREEK Technical Services,.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. III I i i I 1 TAM.KO BUILDING PRODUCTS CREEKAsphalt Shingles TI=CHNICAL SERVICES,LLC Heritage®Woodgate Basic Wind Speed(Vut): Max. 194 mph (Frederick) Basic Wind Speed(Vam): Max. 150 mph l e Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/116 in.OSB existing construction. Underlayment: In accordance with FBC requirements. w Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instruction's when installing shingles at slopes greater'than 21:0. Installation (Non-HVHZ): Installed with 5 in. exposure in ,accordance with FBC requirements and manufacturers; published installation instructions. Shingles shall be attached using either'A Nail Pattern"or"6 Nail Pattern'detailed below:' , I i NAILIONE/�' FASTENERS COMMON BOND II i 5-U2" EXPOSURE 5'111' i' 11" 12-3/8"—I►�I— 11" Figure 10. Heritage®Woodgate(Frederick) II 4 Nail Pattern (non-HVHZ only) P j NAIL ZON E1 COMMON BOND FASTENERS ; , f C yt J'11f.1. I i j1EXPOSURE 5j I 9-1/2" 1" !' I Figure 11. Heritage®Woodgate(Frederick) 6 Nail Pattern ! { I I ,I I I TBP15001.2 Fl-18355-R2 I Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. iThe manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. I , ' I I 'I i S� TAMKO BUILDING.PRODUCTS CREEKAsphalt Shingles TECHNICAL SERVICES,LLC Heritage@ Vintage® Basic Wind Speed(V,fl1): Max. 194 mph (Phillipsburg) Basic Wind Speed Msd): Max. 150 mph Deck(HVHZ): In,accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Mina 15/32; in. plywood existing construction. " Deck(Non-HVHZ): In accordance with FBC r Iquirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/1b in.OSB existing construction. Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBCrequirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater'than 21:'12. Installation HVHZ : Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using!'"6 Nail!Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with. FBC i requirements and manufacturers' published installation instructions. Shingles shall'be attached using either"5 Nail Pattern"or"6 Nail Pattern"detailed below! ' N max aposure i T -9 t��ma z Rb0•h ; t Fastener � I' 6" I! tV3il In II orp 1 T•112" Exposure �+---la?M•� �+—lama"—+{ d Figure 12. Heritage®Vintage.® 5 Nail Pattern (non-HVHZ only) �O' E7R10117R ' Notch A $ 6. F3steneis NOV Zone 17-V X. j 7-]Ar--�-757/!' _I 1, Figure 13. 'Heritage®Vintage' 6 Nail Pattern_ TBP15001.2 FI-18355-R2 ! Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,.installation,recommended use,or other product attributes that are not specifically addressed herein. I � ; I , � i i CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC l' Hip&Ridge Basic Wind Speed(Vut): Max. 194 mph I (Frederick&Joplin) Basic Wind Speed W.,d): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/,32 in. plywood or wood plank for new construction; Min.j 15/32, in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in, plywood or wood plank for new construction;Min.7116 in.OSB existing construction. Underlayment: In accordance with FBC requirements. "' Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall lie away from the prevailing wind. it Directio4n of prevailing wind Start 5-1/8" exposure here— Start here Figure 1 5-1/8"exposure �' 11 •+ 11" 5 - `,- ;I fl ? Fastener Faste0er Figure 2 1,4» Figure 3 li . Figure 14. Hip&Ridge(Frederick&Joplin) j , �I � I i ! TBP15001.2' FL18355-R2 Page.9 of 11 This evaluation report is provided for State of Florida:product approval under Rule 61020-3. IThe manufacturet•shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed;herein. it I . I ' CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC i Vintage@ Hip&Ridge Basic Wind Speed(V,dt): Max.194 mph (Phillipsburg) Basic Wind Speed Msd): Max. 150 mph Deck(HVHZ); In accordance with FBC requirements; J Solidly sheathed min. 19/32 in. plywood Or wood plank for new construction; Min. 15/32 .in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; 1 Solidly sheathed min. 15/.,32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underlayment: In accordance with FBC requirements. Ij Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation'instructions. The direction of the exposed end shall be' away from the prevailing wind. j I; I p II Direction of prevailing wind r , tart �5.,;' exposure I ' re- Fn Start91'11 here Figure 1 5" exposure lot 5 DFF�-L'� Fastenertener' �5-1/2" r `5-1/2, i I 1/4" Figure 2 Figure!3 I , j Figure 15. Vintage®Hip&Ridge(Phillipsburg) I j ii I ' I I I i i i TBP15001.2 FL18355-R2 Page 10 of 11 This evaluation report is provided for State of Florida product approval under.Rule 61 G20-3. IThe manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. I it F ' 1 I ' I R® TAMKO BUILDING PRODUCTS EEK I Asphalt Shingles TECHNICAL SERVICES,LLC I LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and.cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D7158 applies to exposure'B&C with a building mean roof height of 33-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities anddebris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment applicaltion. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, 'and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive i and code compliant detail shall prevail. l ` 8) All products listed in this report,shall'be manufactured under a quality assurance program it compliance with Rule 61620-3. I ' COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance,with the Florida Building Code 5t'Edition(2014)as evidenced in the referenced documents submitted by the Named manufacturer. ,`�G�PFtY R p,c?�,,,, 2015.12.14 ' No 24021 13:44:19 � 05'1 . 3 STATE OF .:�4t] T%• 'c P •'��` Zachary R. Priest,P:E. R V'-"C?N � Florida Registration ,o.74021' A,E ��� Organization No.ANE9641 'it I II CERTIFICATION OF INDEPENDENCE CREEKTechnical Services,LLC does not have,nor will it acquire,a financial interest in any cl mpany manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. j � I Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved inithe approval process of the product. I ' II ,I I i END OF REPORT TBP15001.2 FL18355-R2 Page 11 of.11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration'for whicl this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. a I 9/24/2015 Florida Building Code Online Florida Departmentd BCIS Home ? Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications ! FBC Staff i i BCIS Site Map Links Search y Business; gjjj Product PCOfeSSI naI USER:PubliccUProval Regulation Product Approval Menu>Product or ADDlicatlon Search>Application List>Application Detail i FL# FL10758-R6 Application Type Revision I Code Version 2014 Application Status Approved U Comments } Archived I Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkwaly Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com ,I Authorized Signature Greg Keeler greg.keeler@owenscorning,com l Technical Representative Greg Keeler ! i Address/Phone/Email 2790 Columbus Road li Granville, OH 43023 ! (740)321-6345 greg.keeler@owenscorning.com ! Quality Assurance Representative li Address/Phone/Email i. i l Category Roofing l Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered'lArchitect or a Licensed Florida Professional Engineer 14' I Evaluation Report-Ha'rdcopy Received ' it ' it Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity Miami-Dade BCCO-QUA Quality Assurance Contract Expiration Date 04/13/2018 Validated By Locke Bowden Validation Checklist- Hardcopy:Received I Certificate of Independence FL10758 R6 COI CR14063 2 2014IFBC noniHVHZ Evaluation Report Owens Cornina Vents 060514.pdf ; !' i Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1709.2 hops://foridabuilding.org/pr/Pr_app dtl.aspx?param=wGEVXQwtDgvldAvlteOY0%2bC3zFtrydg9ubWMrxzLHkv1rEPVYDHgEQp/o3d%3d 1/2 i I� i I I 9124/2015 Florida Building Code Online i i Product Approval Method Method 2 Option B i Date Submitted 02/23/2015 Date Validated 02/24/2015 i Date Pending FBC Approval 03/01/2015 {I Date Approved 04/15/2015 Summary of Products I ' FL# Model,Number or Name Description I it 10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic`ridge vents for installation Moisture Ridge Vents in shingle roof systems ! ' Limits of Use Installation Instructions Approved for use in HVHZ:No FL10758 R6 II 6CR14003.2 201JFBC nonHVHZ Evaluation Approved for use outside HVHZ:Yes Report Owens Cdrning Vents 060514.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other: Refer to evaluation report Evaluation Reports ( y FL10758 R6 AEIIOCR14003.2 2014 FBC nonHVHZ Evaluation Report Owens COrninO Veilts 060514.pdf Created by Independent Third Party: Yes u r 10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent Roof Vent With Exterior Louver I i' I d ' is Limits of Use Installation Instruction's I4 Approved for use in HVHZ:No FL10756 R6 II IOCR1400'3.2 20141FBC nonHVHZ Evaluation Approved for use outside HVHZ:Yes Report Owens Cornina Vents 060514.Ddf Impact Resistant: N/A Verified By: Zachary R, Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to evaluation report. Evaluation Reports FL10758 R6 AEIOCR14003.2 2014 FBC nonHVHZ Evaluation e ort Owens C6rnlnq Vdhts 0 0514. df reated by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Aidge Ventilation System-i j Limits of Use Installation Instructions Approved for use HVHZ: No FL30758 R6 II 1OCR14003:'2 2014:FBC nonHVHZ Evaluation Approved for use o ide HVHZ:Yes Resort Owens Cornino Vents 060514.pdf Impact Resistant:N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other:Refer to evaluation report. Evaluation Reports FL10758 R6 AEI OCR14003.2 2014 FBC nonHVHZ Evaluation Report Owens Cornina Vents 060514.12df Created by Independent;Third Party: Yes I • kkoc6c Next ' �� Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Staten ::Accessibility Statement::Refund Statement I' Under Florida law,email addresses are public records.If you do not want your e-mail address released I Ilresponse tda'public-reicords request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please;contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must'provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. I ,' I Product Approval Accepts: SCCUYItY}ILY'RtCa i I a i I i I I. �I i ;I ' f I i i https://fioridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgv1dAvlteOYO%2bC3zFtrydg9ubWMrxzLHkv1rEPVYDH9EQ%3d%3d 2/2 I. N 1W Certificate of Authorization No.29824 CREEM17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 0 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23, 2015 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www.owenscornino.com I Manufacturing Plants: Rohnert Park, CA;Orrick, MO; Baldwyn, MS; Niles,OH ! j I I Quality Assurance: Miami-Dade BCCO—QUA(QUA1591) 1 SCOPE Category: Roofing Ij Subcategory: Roofing Accessories that are an Integral Part of the Roofing System it Code Sections: 1709.2 Properties: Roof Ventilation REFERENCES I it ; II Entity Report No. Standard ;I ; Year Architectural Testing,Inc(TST1558) 01-38660.04 TASiI100(A) II 1;995 i Architectural Testing,Inc(TST1568) 01-38660.05 TAS i100(A) i! 1y995 Architectural Testing,Inc(TST1558) C1774.01-109-18 TAS I110 1,995 ASTM D 635', 2006 I ASTM D 19291 2001e01 i ASTM D 2843; 2004e01 PRI Construction Materials Technologies(TST5878) AVIG-005-02-01 ASTM D 635 i 2006 ASTM D 1929, ; 2001e01 ASTM D 2843 2004e01 PRI Construction Materials Technologies(TST5878) AVIG-006-02-01 ASTM G 155 1, 2005a PRI Construction Materials Technologies(TST5878) OCF-111-02-01 ASTM D 635;i , 2006 ASTM D 1929 2001 e01 ASTM D 2843, 2004e01 PRI Construction Materials Technologies(TST5878) OCF-112-02-01 ASTM G 15511 2005a PRI Construction Materials Technologies(TST5878) OCF-116-02-01 TAS' 10(A) 1, ' 1;995 PRI Construction Materials Technologies(TST5878) OCF-223-02-01 TASi1110(A) II 1995 PRI Construction Materials Technologies(TST5878) OHI-007-02-01 TAS,100(A) ;! 1;1995 PRODUCT DESCRIPTION AND APPLICATION ji I I� I, I! VentSure• 4-Foot Strip 1-1/4" x 14-7/8" x 48" low-:profile attic ridge vent consisting'of a two-layer nylon- Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. 48" t , I - 14-7/8" OCR14003.2 FL10758-R6 !I I' h Page 1 of This evaluation report is provided for State of Florida product approval under Rule 61 G20-3.;IThe mariufactur&shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration"for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not I specifically addressed herein. I; ' I I I I. d ,I I OWENS CORNING ROOFING AND ASPHALT LLC C j VentSurem Roof Ventilation oft-REE". I TECHNICAL SERVICES, LLC I .I Deck Type: Roof deck shall be constructed of closely fitted sheathing;for new or existing construction. Roof deck shall be designedand instialled inilaccordnce with FBC requirements. ;i Roof slope: Minimum 3:12 to maximum 16/12 11 Installation Height: Maximum 60-ft I Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6-inches from the rake edges. Apply a %-inch wide bead of ASTM D 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga.2%-inch galvanized ring shank nails (shall comply'with FBC Section 1506.5) provided with!the vent.' Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 4�7-inches from the start of each vent piece. i Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga. 2%-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) prvided with'the vent or as directed by the shingle manufacturer's installation instructions. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles ! I! VentSuree'Low Profile . 18"x 24°x 2-3/16"(32°x 23"flange base)static off-ridge ventjcomposed of ASTM Slant Back Roof Vent A653 galvanized steel(available with painted finish). ,Material'shall conform with with Exterior Louver: FBC Section 150.7.4.31. I } dtxRHT " � Ll I ' i f �. r _t ZEDUT -+h IT r I i Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed ini'accordance with FBC requirements. OCR14003.2 FL10758-R6I Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3._I1The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not ! specifically addressed herein. it , II ' it I I i OWENS CORNING ROOFING AND ASPHALT LLC d' VentSure®Roof Ventilation Uml.* EK i� TECHNICAL SERVICES, LLC ' Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft I Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately p-inches from the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM p'4586 roofing cement around inner and outer flange. Place vent directly over the Able, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c,and 1-inch from:loutsidej edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per vent). ;f j � 1 Install baffle in %-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with;I:FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring 1,inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. ' Allowable Roof Coverings: Asphalt shingles , ' �I l I VentSure"Rigid Roll 5/8"x 11-1/4"x 20'attic ridge vent composed of high density polypropylene with a Ridge Vent: spun-bond polypropylene fabric. I' i Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in laccordance with FBC requirements. I Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft it Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12;inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to thelfield shfingles. Center the vent over the opening, and fasten the vent 241 finches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall coply withi�FBC Section 1506.5), ensuring%-inch penetration through wood deck. I; Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails(shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's in'stallatio'n instructions, ensuring%-inch penetration through wood deck. Outside edges' of the shingles shall be sealed with flashing cement. i4 ii Allowable Roof Coverings: Asphalt shingles OCR14003.2 FL10758-R6 d I �, ` ;i Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3.liThe manufacturer:,shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration,for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. it i i I I i OWENS CORNING ROOFING AND ASPHALT LLC VentSure®Roof Ventilation CKEEK I !, TECHNICAL SERVICES, LLC I LIMITATIONS !� 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance withlit a 20114 FBC. 4) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. IIII : !I 5) Owens Corning vents shall be installed in strict compliance with Ithis evaluation] report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 6) Deck substrates shall be clean, dry, and free from any irregularities and(debris. All fasteners in the deck shall be checked for protrusion prior to installation. l 7) Installation of the roof assembly is outside the scope of this evaluation. 8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. I I COMPLIANCE STATEMENT I I' I The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with ;the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. ' I ,,���►„�.►�,,,,, ' 2015 02 2 R. . .�,G E N 314:48:59 No 74021 . _ I * _051001 0'.� STATE 0 F :��/ I' .0 AI O r ����` Zachary R. Priest, PI.E. �i,�ss, •........ �C?�.` Florida Registration No.74021 % Organization No.AKE9641 it CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. I CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. � Ih Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. I Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. t I' i i END OF REPORT I f OCR14003.2 FL10758-R6 ;• Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which'his report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. � it I 6/30/2015 Florida Building Code Online i� no M. Florida Lepar(II1ent?r BCIS Home Log In User Registration Hot Topics Submit Surcharge € Stats&Facts 1 Publications ' FBC Staff 1`II BCIS Slte Map ! Links ' ' !Search ; Busines ) ' I ' " s 'Product Approval �r Professi -�I USER:Public User Regulation Product Aooroval Menu>Product or Application Search>Aoolication List>Application Detail I I• � I FL# FL2569-R9 Application Type Revision Q Code Version 2014 Application Status, Approved Comments I f' i 4 Archived II ' Product Manufacturer Soprema, Inc. (Canada) I Address/Phone/Email 1640 rue Haggarty Drummondville, NON-US 00000 ! (819)478-2400 Ext 3327 I memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathieu@soprema.ca I' P ! Technical Representative Marc-Etienne Mathieu I, Address/Phone/Email 1688 Jean-Berchmans-Michaud ` Drummondville, NON-US 00000 (819)478-2400 Ext 3327 I' imemathieu@soprema.ca I. Quality Assurance Representative Jean-Francois Cote, Ph.D. I Address/Phone/Email 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Category Roofing '•I i Subcategory Underlayments II III Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Ha�dcopy Received j 6•, Florida Engineer or Architect Name who developed Robert J. M. Nieminen it the Evaluation Report I Florida License PE-59166 I I Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy,Received Certificate of Independence FL2569 R9 COI 2015 01 COI Niemlinen.Ddfl Referenced Standard and Year(of Standard) Standard I, Year ASTM D1970 I 2009 ASTM D6163 2000 I ASTM D6164 2005 FM 4474 I 2004 FRSA/TRI April 2012(04-12) 2012 TAS 103 I i1 1995 I 1'', haps://floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xYIX2%2f%2bLT9p188%3d 1/2 i p a _ 6/30/2015 Florida Building Code Online TAS 110 2000 I Equivalence of Product Standards Certified By 'I 4 Sections from the Code- i e r ' Product Approval Method Method 1 Option D I� � I Date Submitted 04/17/2015 Date Validated 04/21/2015 Date Pending FBC Approval 04/25/2015 ' I Date Approved 06/23/2015 Date Revised 06/29/2015 a 6 I. Summary of Products FL# Model,Number or Name Description - I 2569.1 Soprema Roof Self adhering roof underlayment's L. Underlayments ..... ;I Limits of Use Installation Instructions Approved for use in HVHZ:No FL2569 R9 II 2015 04 FINAL ER SOPREMA CA�UNDERLAYMENTS FL2569- Approved for use outside HVHZ:Yes R9.12df �I Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166 Design Pressure: +N/A/-90 Created by Independent Third Party: Yes i Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reportsij Use. 2.)The design pressure noted herein FL2569 R9 AE 2015 04 FINALI ER SOPREMA CA' UNDERLAYMENTS FL2569- pertains to underlayment systems used R9.Ddf beneath adhesive-set tile systems. Refer to Created by Independent Third Party: Yes . ER Section 5.6.4 for details. 'dacEr Kid I it f' I o contact us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 II II The State of Florida is an AA/EEO employer.Copydaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released Inlresponse to'la,public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850:487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must$rovide the;Department with an email address if they have. one.The emails provided may be used for official communication with the licensee.However email addresses arel'pliblic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.Td determineIf you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: i I i• I I I � P I 1 i `I I I' lel I 91 I i https://floridabuilding.org/pr/pr_app U.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xYIX2%2f%2bLT9pl88%3d 2/2 ' I i� a!•e _ sd� III„ I I I EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 ERD 353 CHRISTIAN STREET,UNIT#13 1 ' Et\ OXFORD,CT 06478 PHONE:(203)262-9245 i FAX:(203)262-9243 EVALUATION REPORT I it Soprema,Inc. 'Evaluation Report S18010.06.09-R7 1640 rue Haggerty FL2569-R9 Drummondville,Quebec J2C 5138 Date of Issuance:06/15/2009 Canada ! Revision 7:04/17/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations(governing the use of construction materials in the State of Florida. The documentation submitted has been reviewedl by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code; Residential Volume. The products described herein have been evaluated for compliance with the 5 thEdition (2014) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to tNe product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.Eli if the product changes or the referenced Quality Assurance documentation changes. Trinity]ERD requires a comrlete review of'his Evaluation Report relative to updated Code requirements with each Code Cycle. !i li ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity]ERD Evaluated"1 may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall.be done in its erntirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the BuildingOfficial. This Evaluation Report consists of pages 1 through 6. I Prepared by: i 0.1.-S-,�s_ . i pi, ,� A. The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. �7l�FS �»�Cr. �` P•E.on04/17/2015.This does notserve asanelectronically signed Florida Registration No.59166,Florida DCA ANE1983 e..�,,J�I�N'a\ �.s document.Signed;sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: II 1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any companyl manufacturing ori distributing products for which the evaluation reports are being issued. !1 II • it 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen,•P.E. are, in any way,-'the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used.for permlittinar o I r design guidance unless retained specifically for that purpose. f II i it 9 II I I' T.INI` `Y ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards . Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: I ' ' Section Property Standard I II Year 1504.3.1 Wind Resistance FM 4474 2004 1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 ) 2009 1507.4.5.1,1507.5.3,1507.7.3 1507.11.2 Physical Properties ASTM D6163 d 2000 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 TAS 110 Accelerated Weathering TAS 110 1 2000 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) !i 2012 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2' 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007 ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-Rl 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10!1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion Si1150.O5.101R1 09/09/2010 ERD(T5T6049) Physical Properties/Tensile Adhesion S11150.05.091R2 'i 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.111 11/09/2011 ERD(TST6049) ASTM D1970 540540.02.1341 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.141 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645!02.15 ,; 11 02/13/2015 ERD(TST6049) Physical Properties/Accelerated Weathering SOPC-SC85201114 04/17/2015 M-D(CER1592) HVHZ Compliance 09-1005.02 �; 11/04/2010 M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014 ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 ! 10/01/2014 PRI(TST5878) Physical Properties SOP-064-02-01 11 12/03/2013 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: F 4.1 Lastobond TU HT is a self-adhering,non-woven polyester fabric surfaced,SBS modified bitumen roof underlayment. 4.2 Lastobond Shield is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.3 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.4 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.5 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.6 Lastobond 195 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment. 4.7 Lastobond is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roofunderlayment. 4.8 Lastobond Eco is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment. Exterior Research and Design,LLC. 1 Evaluation Report S18010.06.09-R7 CertWcate of Authorization#9503 I FL2569-R9 Revision 7:04/17/2015 j Page 2 of 6 IT.RRINITY! ERD 4.9 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBSimodified bitumen roof underlayment. ! ! 4.10 Resisto LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.11 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.12 Resisto LB1244 is a self-adhering,glass-mat reinforced,sand-surfaced,SBS modified,bitumenl roof underlayment,with a 44-inch sheet width. 4.13 Colphene FR GR is a self-adhering,fiberglass reinforced,granule-surfaced,SBS modified bitumen roof underlayment. 4.14 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof underlayment. t S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert 1 i 1 len, P.E.;;are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. i i 5.2 This Evaluation Report is not for use in the HVHZ. ii 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the,product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for,approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are follows: i. 1TABLET:-ROOF COVER OPTIONS Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate Shingles Shingles Lastobond TU HT Yes Yes YesI Yes Yes Yes See 5.5.1 Lastobond Shield/Pro HT-N Yes No No it I No ii Yes Yes Lastobond Shield HT/Pro HT-S Yes No No Yes` Yes Yes Lastobond/Lastobond 195 Yes No No j No Yes Yes Lastobond ECO /Resisto LB1236, Grip-Rite Eave&Valley Protector/ Yes No No Ni.. Yes Yes Resisto LB1244 ;i . Lastobond Smooth Seal HT Yes No No Yes Yes Yes Ye Colphene FR GR Yes Yes See 555.1 No Yes Yes i Unilay(e) Yes Yes Yes I No No No Batten Only See 5.5.1 li 5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion /long term aging data from an accredited testing laboratory is provided. Underlayment Adhesive(s) Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBond'"Roof Tile Adhesive(FL717) Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) i Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R7 Certificate of Authorization#9503 FL2569-139 Revision 7:04/17/2015 Page 3 of 6 I ' I I ' IV TRINITYJ ERD 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT or Lastobond IPro HT-Slapplied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, Resisto LB1236, Grip-Rite I.Eave & Valley Protector, Resisto LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM 1)41'pHmed structural concrete. l Colphene FR GR applied to: ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: I i ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema rJ commends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue-and-groove board decking be covered withlywoodlor OSB prior to installation of the self-adhering underlayment. i 5.6.2 Bond-to-Insulation: i, I Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond!Pro HT-S or Colphene FR GR applied to: ➢ DensDeck DuraGuard;DensDeck Prime;SECUROCK Gypsum-Fiber Rol Board. For installation under mechanically attached prepared roof coverings, insulatiori'shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,,Appendix D or TAS 114,Appendix J. 5.6.3 Bond to Mechanically Attached Base Laver: ;� ;I, �i I Lastobond Shield,Lastobond Pro HT-N,Lastobond Shield HT,Lastobond Pro HT-S orColphere FR GR applied to: ➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. !i For installations under mechanically attached prepared roof coverings, baselayer shall Up attached per minimum codified requirements. For installations under foam-on the systems,base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not i address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlaym int systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications:, Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,,and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBG 1504.9 has already been applied ).i Refer to FBC 1609 for determination of design wind pressures. it 5.6.4.1 Maximum Design Pressure=-45.0 psf. I Deck. Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)Elastocol Stick or Elastocol 600c Underlayment: Colphene FR GR,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf. ;I Deck: Structural concrete to meet project requirements to satisfaction of AHJll Primer: Elastocol 600c ' Underlayment: Colphene FR GR,self-adhered. i lu 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached'with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in, three,equally spaced rows in the center of the sheet. Underlayment: Colphene FR GR,self-adhered it Exterior Research and Design,LLC: Evaluation Report 518010.06.09-R7 j Certificate of Authorization 719503 t FL2569-R9 iI Revision 7:04/17/2015 Page 4 of 6 �I i II I t I � I i I i� it ERD TRINITY' 5.6.4.4 Maximum Design Pressure=-90.0 psf. I Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Underlayment: Unilay(e)mechanically attached with Soprafix Polymer Batten Ba'r(PBB)�or Soprafix Metal Batten Bar (MBB),with Soprema #15-EL fasteners spaced 16-inch o.c. within the 5-inch wide, self- adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air welding techniques. 5.7 Exposure Limitations: 5.7.1 Lastobond Shield,Lastobond Pro HT-N,Lastobond,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Resisto LB1236,Grip-Rite Eave&Valley Protector or Resisto LB1244 shall not be'left exposed for longer than 30-days after ' I I' installation, I, { 5.7.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than,90-days'after installation. 1 1 5.7.3 Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longer;lthan 180-days after installation. 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published i'stallation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below i 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick,or Elastocol 600c.(if applicable). i 6_3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT.(Lastobond Pro HT-S, Lastobond Lastobond'195. Lastobond Eco: Lastobond Smooth Seal HT. Resisto LB1236 Grip'-Rite Eave & Valley Protector Resisto LB1244 or Colphene FR GR: 1� 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: i1 While priming is optional,Soprema recommends priming with Elastocol Stick or Elastocol 6'c if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and'peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membralne as far'as possible. Once the entire length of membrane is in place, peel-off the release film diagonally whiler,holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical 'seams,, hould be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. �I ! When installing at slopes above 8:12,Soprema recommends back-nailing im the overlap area at the top of the sheet at 12-inch o.c. !i For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge.Drape and press-sheet into place,working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. I, 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to+RSA/TRI April 2012 (04-12) Installation Manual and Table Wherein; using the instructions noted above as a guideline. f' For Colphene FR GR in foam-on tile applications, reference is made to Section 5:6.4 herein for wind resistance limitations. � Tile shall be loaded and staged in a manner that prevents tile slippage and/or damageIf to the underlayment. � a P II Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R7 Certificate of Authorization#9503 FL2569-R9 Revision 7:04/17/2015 y' Page 5 of 6 �I i i y I � i i I ITYER® 6_4 Unila e : II 6.4.1 Non-Tile Applications or Nail-On.Battened Tile Applications: �I j Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12)Installation Manual(if!applicable). I Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach ` the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap nails spaced 36-inch o.c. Apply ithe second course in a water-shedding manner with self-adhering sidellaps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-"inches and staggered not less than 2-ft from vertical seams in the course below. All over- granule end-laps shall be sealed using either heat-welding or hot air welding techniques. Tile (if applicable) shall be loaded and staged in a manner that prevents tile;slippage and/or damage to the underlayment. � ;' I 6.4.2 Foam-On Tile Applications: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and jTable 1 hip rein. II il ' I Apply sheet parallel to the roof edge and,starting at the eave with the selvedge-edge upslope,mechanically attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar (MBB)with Soprema#15-EL fasteners spaced 6-inch o.c. Apply the second courseiin a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over- granule end-laps shall be sealed using either heat-welding or hot air welding techniques. Tile shall be loaded and staged in a manner that prevents tile slippage and or damage to the underlayment. I i 7. BUILDING PERMIT REQUIREMENTS: II As required by the Building Official or Authority Having Jurisdiction in order top evaluat,the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule161G20-3 OA requirements. 9. QUALITY ASSURANCE.ENTITY: I' UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- j i II I' i i i I � !I I ' I I I i ! I Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-R7 Certificate oJAuthorizotion 19503 FL2569-R9 Revision 7:04/17/2015 Page 6 of 6 'i I 'I -0M imNvoo out Mi Rzo Howl KH 04 r .w 1 k BCIS Home Log In j User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map j Links Search i FI rich Product Approval ' USER:Public User Product Aooroval Menu>Product or Aoolication Search>Application List>Application Detail r 9 � FL# FL18355-R2 Application Type Revision Code Version 2014 Application Status Approved Comments Archived 1. Product Manufacturer TAMKO Building Products, IhC. Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com I' Authorized Signature Kerri Eden kerri_eden@tamko.com 'I j Technical Representative Address/Phone/Email Quality Assurance Representative i Address/Phone/Email Category Roofing ii Subcategory Asphalt Shingles 1 i l� I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden Validation Checklist-Hardcopy.Received Certificate of Independence FL18355 RZ COI TBP15001 2 FBC 2014 Product Evaluation Report Shinales.odf 1' I ll Referenced Standard and Year(of Standard) Standard Year ASTM D 3161 2009 ASTM D 3462 2009 ASTMD D 7158 I 2008 I TAS 100 'I 1995 Equivalence of Product Standards 'I Certified By Sections from the Code I Product Approval Method Method 1 Option D Date Submitted12/16/2015 Date Validated 12/18/2015 Date Pending FBC Approval 12/19/2015 Date Approved 02/10/2016 Date Revised 05/09/2017 l' Summary of Products p til FL# Model,Number or Name Description , 18355.1 Glass-Seal, Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles Heritage, Heritage Premium, Heritage Woodgate, Heritage i Vintage, Hip and Ridge, and Vintage Hip and Ridge Shingles Limits of Use Installation Instructions 10 Approved for use in HVHZ:Yes FL18355 R2 1I TBP15001.2 FBC 2014 Product Evaluation Approved for use outside HVHZ:Yes Report Shinales.bdif Impact Resistant: N/A Verified By: Zachary R. Priest PE;74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL18355 R2 AEITBP15001.2 FBC614 Product Evaluation Report Shingles.'odf Created by Independent Third Party: Yes S4ack Next � i, �, i I Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phol e:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement i' Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must 1provide thelDepartment with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available tolihe public.To determine if you are a licensee under Chapter 455,F.S.,please clicke e. Product ApprovalAccepts: it I Credit Card Safe i I I 'I l Certificate of Authorization No.29824 CCRIEEK175,20 Edinburgh Dr r Tampa,FL 33647 TECHNICAL SIERVICFS, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 5TH EDITION(2014) Manufacturer: TAMKO BUILDING PRODUCTS Issued December 14, 2015 220 West 4"'Street 11 . Joplin,MO 64801 (417)624-6644 r Manufacturing Plants: Joplin, MO Phillipsburg,KS Frederick,MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE .Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 1100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS-100 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 1100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 1100 1995 PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-1'30-02-01 TAS 1100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 1, 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS'100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS1100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 63811• 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TASI�00 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161, 2009 UL LLC(TST9628) 04NK24366 ASTM D 3462 2009 UL LLC.(TST9628) 05NK28006 ASTM D 63811 2008(2013)e1 UL 2390 1' ASTM D 7158 2008d UL LLC(TST9628) 06NK03898 ASTM D 3161f 2009 ASTM D 3462 2009 UL LLC(TST9628) 08CA59132 ASTM D 3161 2009 UL LLC(TST9628) 09NK07896 ASTM D 3161• 2009 ASTM D 3462- 2009 UL LLC(TST9628) 1OCA50498 ASTM D 3462 2'009 UL LLC(TST9628) 10CA64882 ASTM D 3161 2009 UL LLC(TST9628) 11NK14014 ASTM D 3161; 2009 ASTM D 3462 - 2009 UL LLC(TST9628) 12CA24551 ASTM D 3161 2009 UL LLC(TST9628) 4786110543 ASTM D 6381, 2008(2013)e1 UL LLC(TST9628) 4787043752 ASTM D 3161' 2009 UL LLC(TST9628) 4787148748 ASTM D 7158 2008d ASTM D 3161 2009 ASTM D 3462 2009 I TBP15001:2 FL18355-R2 I Page 1 of 11 This evaluation reportis provided for State of Florida product approval under Rule 61G20-3. jThe manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration,for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. I i, i ' i