Wind Load Calculation
Property Information Building Information Owner: McClure Wind Zone: 160 MPH. Address: 31 LaVilla Way Exposure Category: B Ft Pierce,F134951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. JU Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) j Height(in) Elevation(ft)JI Pressure(psf) Pressure(psf) 1 Int 26 46 7 32.5 -35.2 ..................................................... ............----............_...............-_._.......-....-._..................................................__..__................................ 2 Int 53 60 7 30.8 -33.6 _.-.--.._.__.. _ _..........---._ .... _............... ..-... ........ ..__.._ ...--._. ....... 3 End 107 65 7 29.2 -36.8 ....... __ . _ ._........--- -._...... ------. . ............__ .........................---— ...... 4 End 107 65 7 29.2 -36.8 ........... ........ ...... __.................................-......................................_...--- - .... ......... 5 Int 107 65 7 29.2 31.9 ......_ _ .................. ....................................................... ................._.............._....-----...................................... . .... .............................................---..__..._................................... . 6 End 74 71 7 29.7 -38.0 .._ —... .._.._._._.-....----.. --..........__..._._ _..._-........ __...._ .........._ 7 Int 26 46 7 32.5 8 Int 37 71 7 31.2 -34.0 9 Int 37 71 7 31.2 -34.0 ----- --------------------- 10 Int 26 46 7 32.5 -35.2 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.Sth Edition(1014)Florida Building Code. Page 1 of 1