EVALUATION REPORT I i
Palyglass USA,Inc. IEvaluatiion Report P22060.02.09-R22
3..50 Lyon Drive FL5259-R26
[late of Issuance;02/24/2009
Fernley,MVV 98408
(570)384-1230 Revision 22:-03/11/2017
i
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the�State of Florida.The1. documentation submitted has been reviewed by Robert Nieminen, P.E.
for, use of the product.under the Florida Building Code and Florida Building Code, Residential volume: The products
described herein have been evaluated for compliance with the 5 Edition (2014) Florida Building Code sections noted
herein. l'
DESCRIPTION; Polyglass Roof.Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assufdnce Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.EJf the,product'changes or the
referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityIERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in it's entirety.
iNSPEcn0N: Upon request, a copy of this entire Evaluation Report shall be provided to the ser by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building.OfficiaL
This Evaluation Report consists of pages 1 through 14.
Prepared by:
4��S 313 :yrfi•;�
' The facsimile seal appean'ng was authorized by Robert Nieminen,
js W P.E.on 03/1312017.Thisdoes not serve as an electronically
�� � signed documient. Si ned,seated;hardcopies have been
Robert:J.M.Nieminen,P.E. •-�,,TFs�o�`��,�: g � g
Florida Registration No.59166,Florida DCA ANE1983 ` l'✓r,,,,,,,,, t� transmitted to the Prodiiet Approval Administrator and to the
named client
i
CERTIFICATION OF INDEPENDENCE; C
1. I Trinity IERD does not have, nor does it intend.to-acquire or will it acquire, a financial interest many company manufacturing or
distributing products it evaluates.
2. TrinitylERD isnot owned,operated or controlled by any company manufacturing or.distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. j Robert,Nierninen,P.E.does riot have,nor will acquire,a financial interest in any otherentity involved in the approval process of the
product.
5. This is a building code evaluation._ Neither Trinity]ERD nor Robert Nieminen, P.E.are,in�any wayi the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting orldesign guidance-unless retained
specifically for that purpose..
l
i
1
• I
i
\J TRINITY ERD
ROOFING COMPONENT EVALUATION: !
1. SCOPE:
Product Category: Roofing
SubwCategory: Underiayment
! Compliance Statement: Roof Underlayments, as produced by Polyglass USA, lnc.,1have clemonstrated compliance with the
following-sections of the a Edition(20141'F arida Building Code through testing Iniiaccordance with the following Standards.
Compliance is:subject to the,installation Requirements and Limitations(Conditions of Use se0tirth herein.
2. STANDARDS: I ;
Section Orope Standard Year
1504,3.1 . Wind Uplift FM 4.474 2004
1504.3.1 Wind Uplift UL 1897 2004
1504.6 Accelerated Weathering ASTM 13154 2006
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.3,1507.3.3,1507.5.3;1507.7.3, Physical Properties ASTM D226 2006
1507.8.3;1507.9.3
1509.2.4,1507.2.9.2,1507.5:3,1507.7.3. Physical Properties ASTM D1970 ° 2009
1507.112 Physical Properties ASTM D6164 2005
i 1507.11.2. Physical Properties ASTM D6222 2008
1507.3.3 Installation Practice FRSA/TRI April 2012 ; 2012
1523.6.5:2.1 Physical Properties TAS 103 I i" 1995
3L REFERENCES:
I Entity Examination Reference Date
1 FM.Appro6als(TST 1867) Wind Uplift 3004091 03/12/2000
PRI(TST 5878) Physical'Properties PRI01111 04/08/2002
I PRI(TST 5878) Physical Properties PUSA-005-02-0101/31/2002
PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002
1 PRI(TST 5878) Physical Properties PUSA-013-02-•02 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02 03 i! 12/23/2002
f
PRI(TST 5878) Physical Properties PUSA-018-02-41 07/14/2003
j PRI(TST 5879) Physical Properties PUSA-028-02-02 07f13/2005
PRI(TST 5878) Physical Properties PUSA 033-02-01 01/22/2006
PRI(TST5878) Physical Properties PUSA-035-02-;Q1 09/29/2006
j
PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5879) - Physical Properties PUSA-061-02-02 ;' 01/28/2008
i PRI:(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA=083-0201 04/14/2008
PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009
MT1(TST 2508) Physical Properties 1X20H7A f 04/01/2008
MTI(TST 2508) Physical Properties RX14EBA I 01/29/2009
ERD(TST 6049) Physical Properties 11752,09.99-1 02/08/2000
ERD(TSE 6049) Wind Uplift 11757.08.01-1 1 08/13/2001
ERD(TST 6049) Wind Uplift 11776 06.02 d 01/16/2003
ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003
I ERD(TST 6049) Wind Uplift 01740.01.07 ! 01/04/2007
ERD(TST 6049) Physical Properties P5110:04.07-1 ! 04/11/2007
ERD(TST 6049) Wind uplift 09260.0308 i 03/21/2008
ERD(TSE 6049) Physical Properties P13450.08.091 08/13/2009
ERD(TST 6049) Wind Uplift 1330540.11.09-R1 1 11/30/2009
1 ERD(TST 6049) Physical Properties P111.030-11.611 11/30/2009
ERD(TST 6049) Wind Uplift P11030.11.0%2 , 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09 3 11/30/2009
ERD(TST 6049) Physical Properties P33360-06,10' 06/25/2010
ERD(TST 6049) Physical Properties P33370:03.11 03/02/2011
A Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22
certificate ofAuthorrzotion#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. C Revision 22:03/13/2011
Page 2 of 14
"t
i 'f '
f_)o
TRINITY IERD
fnti Examination Reference Date
ERD(TST 5049) Physical Properties P33370.04.11 I 04j26/2011
ERD(TST-6049) Physical Properties P37300.10.11 10/19/2011
ERD(TST 6049) Physical Properties P40390:08.12 it 08/06/2012
P40390.08.12=2
ERD(TSf15049) Physical Properties08/07/2012
ERD.(TST'6049) Physical Properties C41420 09.1223 09/11/2012
ERD(TST.6049) Wind Uplift
P391390:0113! 03/04/203.3
ERD(TST 6049) Physical Properties P45370.04.13 3 04/26/20'13
ERD(TST..6049) Wind Uplift P1738.02.07-k2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-�-Rl- 04/30/2013
ERD(TSTIJ049) Wind Uplift P416k.08.13' 08/06/2013
ERD(TST-6049) Wind Uplift P1175145.039 I RI 11/26/2013
ERD(TST�,�049) Wind Uplift P1 5.14 11781.11.03-112 11126/2013
P45270.0 11
ERD(TST 6049) physical Properties 1 05/12/2014
ERD(TSTT'049) 09/08/2014
6 Physical Properties
ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD-(TST 6049) Physical Properties 6020.09.14-3 I 09/00/2014
ERD(TST 6049) Physical Properties 6020.09.14-.4 09/08/2014
ERD(TST 6049) Physical Properties 6020.'09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/20I4
ERD(TST 6049), Physical Properties P44360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P43290J0.14I 10/17/2014
ERD(TST.6049) Physical.Propertles PLYG-SC75S( ')3A5 03/24/2015
ERD(TST:6049) Physical Properties P40390.04.15'1 04/03/2015
ERD TST 6049) Physical Properties PLY&SC8080,05.15-1 s 05/20/2015
II ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
M,(TST 6049) Physical Properties PLYG-SC8080.67A65 07/16/2016
ERD(TST.6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 1 11/01/2014
Miami-Diide(CER 1592) HVHZ.Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cress Ltg j 03/01/2008
Polyglass''USA Materials Affidavit Polystick SA Compound;', 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.04/24/2018
4 PRODUCT DESCRIPTION:
41 �
ene Urid r ec anic ii_6A
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base-sheet. i ;. ,
4.1.2 Elastobase V is a polye'ster-reinforced,SBS-.modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sleet.
Self Adhering
L
4.2.1 PoIVAick MTS is a nominal 60-mil thick rubberized asphalt waterproofing r6embrah!d,glass fiber reinforced,surfaced
with pblyolefinic film,surface;meets TAS 101
4.2.2 Poly§tick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly-flim surface;meetsTAS 103.
4.2.3 Polystfc.k.111M
�� -is,a nominal,-60.�mll thick rubberized asphalt waterproofing emb arie,glass fiber reinforced,with an
aggregate surface;meets ASTM D1970.
E�aluation Report P12060.02.09-R22
Exterior Rese6rch and Design,I.I.C.
Cert(cote of Authorization#9503 FBC NON-HVHZ EVALUATION FL52S9-R26
Polyglass USA,Inc. Revision 22-03113/2017
Page3 of 14
\JTRIM-rYIERD
4.2.4 Polystick TU Plus is a nominal 80-mil,thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets MW D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing Membrane, glass-fiber/polyester
reinforced,with a granular surface;meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max Is a nominal 60-mil thick rubberized asphalt waterproofing membrane With a 190 g/m' polyester
fabric surface;,meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP,.Polyflex SAP FR, Mule-Hide'SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet ASTM D6222.
4.2.8 Polystick Dual Pro'"' is a nominal 60-mil thick dual-layer rubberized asphalt walierproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.9 Polystick 11fle Pro'"' is a nominal 60-mil thick dual-iayer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103! I I
4.2.10 Polystick MU-X is 'a nominal 54-mil thick dual4ayer rubberized asph I ait waterproofing membrane, fiberglass
reinforced,with a polypropylene film surface; meets AC188 and physical quremlI ents ofASTM D1970 (See Section
5.8). T
lit
iiddd Under dVments:,,.-
F, i`i e r 136
nic.
4.3.1 Elastoflex 6 TU is a polyester reinforced, modified bitumen the underlayment composed of an sand-surfaced SBS
modified bitumen back-side and granule-surfaced APP modified bitumen top-side;., Elastoflex G TU is for use as an
alternate to "Mineral Surface Roil Roofing" (ASTM D638.0, Class M)-in the "Single;Ply System" from FRSA/TRI April
2012.(04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adher6d' the roof systems.
4.3.2 Elastoiflex S6 G and Elastoflex S6.G Flit are polyester reinforced,SBS modified bitumen cap Sheets;meet ASTM D6164.
t I I,,
Elastoflex S6 6 and Elastoflex S6 G FR are for use as an alternate o "Mineral Sufface R611 Roofing" (ASTM D6380,
Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mech I dhicallyfastened the roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied"Cap Sheer in thel'."Two Ply System"from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use at an
alternate to Hot Asphalt applied "Cap Sheer in the "Two Ply System" fr I Orn FRSA/TRI April 2012 (04-12) beneath
mechanically fastened the roof systems.
4.8.3 Polyflex G and Polyflek 6 FR are polyester reinforced, APP modified bitumen) cap sheets; meet ASTM 06222.
Polyflex G is for use`as an alternate to Heat Applied "Cap Sheer in the "Two Ply System"from FRSA/TRl April 2012
(04-12)beneath mechanically fastened or adhered the roof systems. Polyflex 4"is for use an alternate to Heat
l 13 1se a-
Applied "Cap Sheet" in the"Two Ply System" from FRSA/TRI April 2012 (04-12) b1eheath.'mechanically fastened file
roof systems.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert 14 it:,,ut ien, P.Ei are, in,any way,the Designer of
Record for any project on which this Evaluation Report, or previous versions ther'dof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Unde rlayments may be used with any prepared root cover where the!product is specifically referenced
within FBC approval documents. If not listed, a request may be made;to the Authority Having Jurisdiction for
ii approval based on this evaluation combined with supporting data for the prepared roof covering.
Werlor Researth and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate ofAuthotization#9503 FBC NON-HVHZ EVALUATION I FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 4 of 14
C�o
I I {I
TRINITY ERD
5.5 Allowable Roof Covers:
COVERTALE 2 ROOF
7,
Underlayffient Asph.alt Shingles Nall-On Tile Foam-On Tile Metal Wood Shakes Slate
ishingles
Yes YesYes
Elastobase. Yes Yei Yes
(Base sheet in 2-ply system) (Base Sheet ln.2-ply system)
Efastobase Yes Yes P Yes Yes Yes Yes
(Base Sheet int-ply system) (Base Sheet In 2-p system)
rulyulabb G2.4 Ddse No Yes Yes I Nol No No
(Base Sheet in 2-ply system) {Base Sheet in 2-ply system
Polyglass APP Base No Yes Yes
(Base sheet In 2-pfysystem) (Base Sheetin 2-ply system) •I NoH No No
Polystick MTS Yes Yes No Yes' Yes Yes
Polystick WS PLUS Yes Yes No,- Yes Yes Yes
Polystick WXe Yes No No No! Yes Yes
Polystick*TU P Yes Yes Yes (See 5.5.1) 1 No{jYes Yes
Polystick tU,Plus -Yes Yes Yes (See 5.5.1) 1 Yes Yes Yes
Polystick TU Max No Yes Yes (See S.51) Yes:1, No No
Polystick Dual Pro Yes Yes No Yegi Yes Yes
Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yeg.;�' Yes, Yes
Polystick IVIIJ-X yet No No Yes'!: Yes Yes
Elastoflex S6,G Yes Yes Yes (See 5.5.1) No,, Yes Yes
Elastoflex 5.6G FR Yes Yes No No, Yes Yes
Elastof1mGTIJ Yes Yes Yes (See 5.5.1) No,I i Yes Yes
Polyflex G • Yes Yes Yes (See 5.5.1) Yes Yes No,1.
Polyflex GTR Yes Yes No No;l, Yes Yes
Polyflex SAPor SAP FR Yes Yes Yes (See 5.5.1) No'' Yes Yes
Mule-Hide 5A-APP Cap Sheet
or SA APP Cap Sheet(FIR)
Yes Yes Yes (See S-5.1) NO Yes Yes
I
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayTent combinations.
r.
TABLE*'2i4'
AMOWAkititE ES(VE ERWM MTCO
M3!q0oNs
Florida Product
Adhesive Underi6ymentis
Approval
Convenience Products'Touch-'n FL14506 Polystick TU Plus,Polystick'TU Max 1,
Seal Stornil3ond Roof-rile Adhesive
Dow TlleBondl FL717 Polystick TU P,Polystick TO Plus,Po"i0ex SAP or-rile Pro
Polystick TILI P,Polystick TO Plus,Polystickfll Max,Polystick Tile Pro,
ICP Adhesives Pplyset"AH-180 FL6332 ElastciflexGTU,ElaistoflexS6 G,Polyflex G.Polyflex SAP,Polyflex SA Cap
Fit;Mule-Hide SA- PPCapSheet ule-Hi SA-APP Cap Sheet(FR)
Hide
Polystick TU P,Polystick TO Plus,PWstick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TO,Elastofiek'S6 G,Po,1Yflex G,Polyflex SAP,Polyflex SA Cap
FR,Mule-Hide SA-APP CaO,Sheet o r!"Mi6le-Hicle SA-APP Cap'Sheet(FR)
Polyglass Po)yL6k Roof Tile FL17855 Polystick TU Plus or FOIYSIEICK TU Max
Adhesive. I
j
Referto Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,LLC• I Evaluation Report P12060.02.09-R22
Cwielcte ofAuthorizatfoo M03 FBC WON-HVHZ EVALUATIONFL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 5 of 14
I
,i
' TRINITY j ERC?
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to: �'
➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; Ne.w or,existing, unprimed OSB; ASTM D41 primed OSB; SOUtherri:;Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete;- Huber'l Engineered Woods "ZIPSystem" Panels
(designed and installed to meet wind loads for project).
Note:Polyglassdoes not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathingshould be cleaned of all dirt and debris prior to application.of Polystic(emembranes.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
i.
➢ ASTM D41,primed structural concrete.
Polyflex G.or Polyflex G FR torch-applied to:
ASTM D41 primed structural concrete.
5.6.2 Bond-to-insulation:
Polystick(all variations),Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA'-APP Cap Sheet(FR)self-adhered
to:
ASTM C1289, Type II, Class 1 po€yisocyanurate or Type V polyisocyanurate j'bmposite insulation; Dens Deck
DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU,Elastoflex S6G or Elastoflex S6 G FR in hot asphalt to:
t Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR.torch-applied to: j
➢ ASTM D41 primed-structural.concrete;Dens Deck Prime or SECURO.CK Gypsum-Fiber Roof Board.
I
Far installation under mechanically attached prepared roof coverings, insulationshall be attached per minimum
requirements of the prepared_roof covering manufacturer's Product Approval. For.instailations under foam-on tile
systems;insulation attachment shall be designed by a qualified design professional and€nstalled based on testing of
the insulat€on/underlaymerit system in accordance with FBC Section 1504.3!1. I i
5.6.3 Bond to Mechanically Attached Base Laver: ;
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile P=ro selfaaheredto:
➢ ASTM D226,Type-1 or 11 felt;Elastobase;Elastobase P or Mule-Hide Nail Base.
Elastoflex_G TU,Elastoflex 86 G or Elastoflex S6 G FR in hot asphalt to:
i ➢ ASTM D226,Type I or.11 feit;.Elastobase;Elastobase P,Muie-Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
I ➢ Elastobase;•Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APO tase.
For installations.under mechanically attached prepared roof coverings, base layer 'shall be attached per minimum
codified requirements. For installations under foam-on the systems, base layer;shall be attached per minimum
' requirements:of FRSA/TRI April 2011,(04-12),Appendix A,Table 1,or as listed in S
ection S.6.4 herein,or as tested in
accor
nce with
BC
Wind Resistancer U F odl
on 1504.3.1.
5.6.4 Wierlavme t Systems in Foam-On Tile Aoalicatiori�: FRSA p
JTRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foamlon the 1 ystems, where the underlayment
f forms part of%the load-path. The following wind uplift limitations apply to underlayment.systems that are not
addressed in FRSAJTRI April 2012(04-12)and are used in foam-on the appiicatlonsl:j+Maximum Design Pressure is the,
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).;Refer to FRSAJTRI April 2012(04-
12),Appendix;A,Table 1A or FBC 1609 for determination of design wind loads. 1
Exterior Research and Design,ILC. Evaluation Report P12060.02.09-R22
1FL5259-R26
' certificate ofAuthorizotion#950 FBC NON-HyHZ EVALUAiiON I
Polyglass BSA,Inc. Revision 22:03/13/2017
Page 6 of 14
i
I _.
TRI
NiTYIERD
5.6.4.1 Maximum Design Pressure -90 Ps
Deck- Min.15/32-inch plywood to meet project requirements to satistaction Or Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-97.5 pst-
Deck: Un.S5/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply, .'(Optional)Polystick MTS PLUS,self-adhered
Undeelayment:'Polystick TU P,Polystick TU'Plus,Polystitk TU Max,Polyflex SAP,Polyflex SAP, FR,Mul,e-Hide,SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FIR),self-adhered and back-nailed within the;selvedge edge Side laps using 12 ga.x
.1Y."ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced,12-inch o.c.
5.6-4.3 Maximum Design Pressure=-105 ptf: ILII
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-18600
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP TR,Mule-Hide SA-APP Cap Sheet and
Mule=Hlde SA-APP Cap.Sheet(FR)1_ self-adhered and back-hailed within the selvedge-edge side laps using 12 ga.x
IYV ring shank nails through 32 ga.,1-5%8"diameter tin caps spaced,112-inch&'.ci.
5.6.4.4 Maximum Design Pressure=-135 y
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Aut I h I ority Having Jurisdiction.
Primer: (Optional)P(3160 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood Joints.
Base Ply; (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,PolystickTU Max,Polyflex SAP,Polyflex SAO�FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.5 Maximum Design Pressure=-315 P_
Deck: Structural concrete to meet project requirementsto satisfaction of Authority;i Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Tile Pro,Polynex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6-4.6 Maximum Design Pressure=-622.5 pd
I ., . di
Deck: Structural concrete to meet project requirements to satisfaction of Authority HavingJuns iction.
Primer: Pisiod or ASTM 641 1 1 i I
:
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Poiyflex G,torch-applied.
5.6.4.7 Maximum Design Pressure=-30.0 Osf`
Deck: Min.15/32-Inch OS3 to'meet project requirements to satisfaction oflAuthorliyHavingJutisdiction.
Base Sheet: Elastobase or Mule-Hide,Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-Inch long x 1-inch head diameter round metal cap nailsi
Spacing: -6-inch o.c.at the 3-inch wide side laps and 6-Inch o.c.at two(2)equ'ally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TLI P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP�FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.8 Maximum Design Pressure.=-37.5 psf*
Deck: �-Min.15/32-inch plywood to meet project requirements to satisfaction of,Put�iorityHavingJurisdiction.
Base Sheet: 'Elastobase or Mule-Hide Nall Base(poly-film.top surface)
Fasteners: 11 ga.x 1.25-inch Iong x 1-inch head diameter round metal cap nails
Spacing: 6-inch ci.c,at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Rase Ply: (Optional)Polystick MTS PLUS,self-adhered I
Underlayment:Polystick TU P,PolystickTU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
,Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. ! Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATIONFL5259-R26
Polyglass USA,.Inc. Revision 22:03/13/2017
Page 7 o 14
"
TRIN17 Yr ER®
5.6.4.9 Maximum Design Pressure=47.5.psf*:
Deck: Min.19/32-lnch,plywoodto meet project requirements to satisfaction of Authority Having,Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type Afelt
Fasteners: 11 ga.x 3:25=inch long x1-inch head diameter round metal'cap nail
Spacing: 6-Inch o.c.at 3-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
i Base Sheet One(1)layer ASTM D226,Type 11 felt I
Fasteners: 12 ga.x2.25-Inch x 3/8-inch head diameter annular ring shank roofing nails jtA-5/8-inch diameter tin caps
f Spacing: 4-inch o.c.atthe 2-inch:wide side laps and.4-inch o.c.attwo(2)equally spaced staggered center rows.
i Base Ply: (optional;for use With self:adhering underlayment only)Polystick MTS PLUS),self-a&red
Underlayment:;Polystick TUT,Polystick TU Plus,,Polystick TU Max,Polyflex SAP,Polyflex SAP!FR,Mule-Hide.SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied iriifull mopping of hot asphalt.
5.6.4.11 Maximum Design Peesst re=-45psf*: I !'"
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)'layers ASTM D226,Type 11 felt
Fasteners: 11 ga.x1.25-inch long x 3/8-inch head diameter annular ring shank roofing lis at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c..atthe Nrich wide side.laps and"9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: :(Optional for use with self-adhering underlayment only)Polystick MTS PLUS!self-adhered
Underlayment:Polystick TU P;Polystick TU Plus,Polystick TU Max,PolyflexSAP,Polyflex SAP;FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered orElastoflex G TU o�Elastofl'ex S6.6,�applied in full mopping of hat
iasphalt.
! 5.6.4.12 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inctf plywood to meet project requirements to satrsfactlon of Authority Having Jurisdiction.
Base Sheet: Elastobase(saridecitop surface for hot-asphalt or torch-applied cap or poly-film surface'for torch-applied cap).
Fasteners: Simplex.MAXX:Cap Fasteners,
Spacing: 97inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:%stoflex G TU or ElastoflexS6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4-13 Maximum Design Pressure==52.5 psf: ( '
Deck: Min.15/32-inch plywoodto meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded.top surface for hot-asphalt or torch-applied cap or poly-filrn surface for torch-applied cap)
Fasteners: Simplex,MAXX Cap Fasteners '
Spacingt 9-inch o.c.at the.2-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex'0 TU or Eiastoflex S5 G,applied in full mopping of hot asphalt or Polyflex G,,torch-applied.
5.6.4.14 Maximum Design Pressure=-52.5 psf:
Deck: Min.15 324nch Isatisfaction
h s
/, p ywood'to meet_project requirements to satisfacti�n of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P;Polystick TU Plus,Polystick TU Max,PolyflexSAP,Polyflex SA FR,Mule-Hide SA=APP Cap Sheet and
Mule-Hide SA-APP`Cap Sheet(FRI,seif-adhered.
5.6.4-1S Maximum Design.Pressure -52.5 psf:
Deck: Min.15/32-Inch plywood.to meet project requirements to satisfaction of Authority Hexing Jurisdiction.
.Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 64nch o.cratthe 3-inch wide-side.laps.and 6-inch o.c.at four(4)equally space',,staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot aspl%alt or PaI' lex G,torch-applied.
jjIl ;
i Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate ofAuthodzotion!19503 FBC NON-HVH2 EVALUATION i Ft5259-R26
i 1 Polyglass USA,Inc. i Revision 22:03/13/2017
{ Page 8 of 14
i I i�
i
i
IF)O
TRIN `1I I ERD
5.6.4.16 Maximum Design Pressure==60 psf: I 11
Deck: Min..19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top.surface for hot-asphalt or torch-applied cap or poly-ficin surface for torch=applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 15/84nch diameter tin caps
Spacing: 8-inch o.c.-at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G torch-applied.
5.6.4.17 Maximum Design Pressure=-60 psf �'
Deck: 'Min.19/32-inch plywood'.to meet.project requirements to satisfaction of Authority Havmg,Jurisdiction.
Base Sheet: =Elastobase(sanded top•surface for hot-asphalt or torch-applied cap'or poly-filrn surface for torch-applied cap)
Fasteners: 'OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: '12-inch q.c.at the 4-inch wide side laps and 12-inch o.c.at:two(2)equally sp,ced staggered center rows.
Underlayment:;Eiastoflez G TU or Elastoflex SEG,applied in full mopping of hot asphalt or Po. ex G;torch-applied.
5.6.4.18 Maximum Design Pressure=-67.5 psf I,
Reck: Min.15/32-inch plywood-to meet project requirements to satisfacti I
n of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underloyment)
Fasteners: 12 ga.x 1.25-inch'long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side.laps and-8-inch o.c.at four.(4)equally'spac id staggered center rows.
Underlayment-Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt for torch-applied or Polyflex_.G,torch-
applied.
I 5.6.4.19 :Maximum Design Pressure=-75 psf.
Deck: Min.15/32-inch plywoodto meet project requirements to satisfaction of Authlority Having Jurisdiction,
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of.torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"GalvalumCSteel Plates,OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Ins ul cation Plates or Simplex MARX Cap
Fasteners
Spacing: l0 inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)'equally spiaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt ar torch=applied or Polyflex G, torch-
applied. I .
i 5.6.4.20 Maximium Design Pressure=-90 psf: f
Deck: _Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Hai ing.lunsdietion.
Base Sheet: Elastobase(sanded top surface forhot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MARX Cap Fasteners I {
Spacing: 6-Inch o.c.at the 2-inch wide side laps and 6-Inch o.c.at two(2)equally spaced fstagg6red center rows.
i Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Po'lyflex G,torch-applied.
5.6.4.21 Maximum Design Pressure=-90 pd:
{ Deck: IVIin.15/32-inchI `
p ywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Fiat Bottom Metal
I Plates i �i
i Spacing: 64nch o.c,at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Eiastoflex G TU or Elastoflex G,applied in full mopping of hot asphIalt or Polyflex G,torch-applied.
i 5.6.4.22 Maximum Design Pressure 90 psfi• I €
Deck: Min.15/32 inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface) i4
I
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates ,
'Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex 6 TU or Elastoflex S6 G,applied in full mopping of hot.asphalt.
i
Exterior Research and Design,U.C. Evaluation Report P12064.02.09-R22
Certificate ofAuth6fization#9903 FBCNON-HVH2EVALUATION FL5259-1126
Polyglass USA,Inc. i Revision 22:03/13/2617
Page 9.of 14
I`
TRINI )))ERD
5.6:4.23 Maximum Design Pressure==90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underiuyment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD.with OMG-3"G,aivalum6 Steei Plates, OMG Roofgrip.#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3=,inch insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: +9-inch o.c.at the 4-inch wide side laps and 9-inch o.c,at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mopping,of hot)asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.24 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfacti9n of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) I
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails ate 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment-Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Poilyflex SA 1'FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.25 Maximum Design Pressure=-105 psf: i
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap'or poly=fill In surface for torch-applied cap)
Fasteners: Simplex MAXX.Cap Fasteners
Spacing: 6-inch mc.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G.TU or Elastoflex S6 G,applied in full mopping of hot asp alt or Palpflex G„torch-applied.
5.6.4.26 Maximum Design Pressure=-112.5 nsf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having jurisdiction.
jBase Sheet: Elastobase"or"Mule-Hide Nail Base(poly film top surface)
Fasteners: "11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails aft-5/8-inch diameter tin caps
Spacing: -6-inch o.c,at the 4-41nch wide side laps and 6-inch o.c.:at four(4)equally spaced.staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps C
Base Ply: Polystick-MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
'
Mule-HideSA-APP Cap Sheet(FR),self-adhered. i
5.6.4.27 Maximum Design Pressure=-120 psf: I
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
JBase Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-flim surface fortorch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"E ound Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equa#ily space'd'staggeied center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or P610, ex G,torch-applied.
1 5.6.4.28 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-Inch plywood to meet,project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners, Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal insulation Plates
Spacing: 64nch o.c.at the 4-Inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:ElastoflexG TU or Elastoflex S6 G,applied in full mopping of hot asphalt.l
5.6.4.29 All other direct-deck, adhered Polyglass Underlayment systems beneath foam.-on Mile systems carry a Maximum
Design Pressure of-45 psf. 1 1
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVH2 EVACUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
{ Page 10 of 14
I,
i -.
i
I
i
TPJNIT ERD
5.6.4-30 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed
"that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design.
pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density
designed by a qualified:design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29 and Roofing Application Standar d RAS 117. Assemblies marked
I with anasterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention'Data Sheet 1-29 (January
I 2016)for Z062/3 enhancements.
f5.7 Exposure limitations: I I
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation. I
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be'left exposed for
longer than 180-days after installation.
i Polyflex SAP or SAP FR, or Mule-Nide SA-APP Cap Sheet or SA-APP Ca p Sheen (ER) does not have an exposure
!
i limitation, unless the prepared roof covering is to be adhesive-set tile, m�whuh e``a se the;maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex$6 G FR or Polyflex G or Polyflex G FR does not have an.exposure limitation,unless the
prepared roof`covering is to be adhesive=set tile (Elastoflex S6 G or PolyFlex G only), inwhich case the maximum
exposure is 180;days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefi'raient of friction than ASTM D226
roofing felt in a dry-condition,tested at:standard laboratory conditions. Agreementibetween purchaser and seller,as.
set forth in Section 5.3,Note 1 of ASTM D1970-09,should be established as':I o slip resistance.
6: INSTALLATION:
6.1 Polyglass Roof. Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics-noted below.;
6.2Re-fasten any loose decking panels, and check for protruding nail heads. Sweep thie,substrate thoroughly to remove
any dust and debris prior to application,and,prime the substrate(if applicable).
6 3 Elastobase,Elastobase,-R9 Mule-Hide
6.3.1 Shall be-installed in compliance with the codified requirements for ASTM D226,Type'11 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
t;
Reference is.made to the current edition of the NRCA Steep-slope Roofing'Manual'and ARMA recommendations for
installing shingle underiayments and flashings
j,I
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule-Hide SA-APP Cap Sheet or SA=APP Cap Sheet (FR), Dual Pro or Tile Pra; self-adhered, Elastoflex G TU,
Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyfleu 6 or Poiyflex:G FR,torch applied.
6.3.3 Tile Anblications: #
Reference is made to FRSA/TRI April 2012(04-12)installation Manual and Table i herein,using the instructions noted
aboveas'a guideline.
5 f '
i
j
:Euterior Research and Design,U.C. ; Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION l F1.5259-1126
Polyglass USA,Inc. ( Revision 22:03/13/2017
i
Page 11 of 14
V
I I
I
I
1 ERCP
1 L�
6 4 Polystick MTS,MTS PLUS,iR Xe,1 U P,TU;PIus,TU Max,i)uai Pro,Tiie Pro Ior MU-X or Potyflex SAP,Poiyflex 5AP'FR,
Mule tilde SA APPCap Sheet or Nitaule-tilde SA APP Cap Sheet{FR}. � ;. j� ',,,�?� ,...Y.'.. 4 '�>.. .
6.4.1 Shall be installed in compliance with the codified requirements for'ASTM D1970 underlayment in FBC Sections 1507
for the"type of prepared roof covering to be installed.
Note; Polystick MUX has beerr'found through comparative testing.to,have a lessercoefficient of friction than ASTM
D226 roofing felt in a dry condition, tested.at standard laboratory,conditions. Agreement between purchaser and
seller,as set forth in Section 5.3,Note 1 of ASTM D1970-04,should be established a(s to slip,resistance.
6.4.2 Direct to-Deck with Mechanically Fastened Roof Covers: 4
All self-adhering materials,with the exception of Polystick TU Plus,Polyflex SAPorSAP,FR and Mule-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet(FR).should be back-nailed in-selvage edge seam in',accordance with Polyglass/Mule-
Hide,Back Nailing Guide. Nails shall be corrosion resistant,11 gauge ring-shank type with a minimum 1-inch'diameter
metal disk or?Simplex-type metal cap-nail, at a minimum rate of i1 " D.C.� Polystick TU Plus should be back-nailed
using the.above noted fasteners and spacing,in area marked"nail area,area paralclavar"`,on the face of membrane.
The head lap-membrane is to:coyer the area being back-nailed. (� ,
All seal-lap seams ('selvage laps) must be
firmly rolled with a minimum 28 lb. hand
i roller to ensure full contact and adhesion.
For Dual Pro and.Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
i,
View of Ovelap Sear of Dual Prod and Tile Pro
All over-fabric,and over-granule end-laps shall have a 64nch wide, uniform layer of,Polyplus 50 Premium Modified
Wet/DrV Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TCI Plus,Dual Pro and Tile Pro may not be used in any exposed a plication such as crickets,exposed valleys,
or exposed roof to wall details `
Repair of Polysticic,membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement:or
Polyglass PGSI)0 Modified Cement to the area in need of repair,followed by a'minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand roiled in place over the repair areal Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minirrium of 40-lb weighted-roller or,on steep slopes,use of a stiff broom1with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min;28 lb'roller)or small areas of the
i roof that are riot accessible to a large roller or broom.
1 6.4.3 rile Applications.(not allowed for Polystick1R-Xe or Polystick MUX): I ti
Reference is made to FRSA/T9I April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
i above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet ar,�f d self-adhering top sheet(s),Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-22),Table 1.
For adhesive-set file applications,refer to Section 5.6.4 herein. I '
For nail-on tile?systems over Polystick MTS;battens are required for loading]staging{of the tile.
For nail-on tilesystems over Polystick MTS PLUS:
Battens are required for loading/staging of lugged tile regardless of slop e.
➢ Battens are required for loading/staging of flat tile at slopes in excess of-5:12. 'ry
Exterior Research and Design,CLC.. i Evaluation Report P12060.02.09-R22
Certificate ofAutl offtdon#9503 FBC NON-HVHZ fVAWATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
i Page 12 of 3:4
I:
PG
f
l
�pTRINIIY I ERCP
6.4.4 Two(2)Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TO P,TU Plus, !U Max;;Tile Pro,MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated.with
the top-layer'material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired.
Polystick MTS.PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Proor Polyf`,k SAP is allowable for use under
foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is
allowable if a 2-ply Underlayment system is desired.
6 5 Elestoftex G TU,Elastofletc S6 G or_Elastoflex S6 G FR `
6.5.1 Elastoflex G TU,Elastoflex S6.13 or Elastoflex S6 G FR shall be installed in complianee with current Polyglass published
installation requirements. For use in.file applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the"Single
Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened file roof systems or the Hot Asphalt
applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012,(04-12)beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roo in' M$D6380,Class M)in the"Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tilqroof systems or the Hot Asphalt
applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex 56 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRt April 2012(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt
applied"Cap Sheet"in the."Two Ply System"from FRSA/TRl April 2012(04-12)beneath;mechanically fastened the
roof systems.
6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR scall be fully asphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-Inch wide, offset
minimum 3 feet from course to course. Side-and end laps shall be fully adhered in a complete mopping of hot asphalt
With asphalt extending approximately 3/8-inch beyond the lap edge
6 6_'- Polyflex1G or PoIV,lex G FR_ ? )
6.6.1 Polyfigx G or Polyflex G FRshall be installed in compliance with current Polyglass p6blished installation requirements.
For use in tile applications:
✓ Polyflex'G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two'jPly System"from FRSA/TRI April
2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G OR is for use as an alternate to the Heat Applied applied "Gap Sheet" in the "Two Ply System" from.
FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof Syst.i'ms(Base Sheet Limited per 5.6.3).
i'
6.6.2 Polyflex G or Polyflex G FR shall. be fully torch-applied to the substrates,noted Vin'Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide,,off-set minimum 3 feet fromcourse to course. Side and end
i laps shall be fully heat-welded and inspected to ensure minimum 3/84 ch flow of modified compound beyond the lap
r edge.
t
r i
i
Exterior Research and Design,U.C. i Evaluation Report P12060.02.09-R22
Certiftate afAuthodzadon#9503 FBC NON-HVH2 EVALUATION � FL5259 R26
Polyglass USA,Inc # Revision 22:03/13/;017
I �ra Page 13 of 14
1,I
,
\\�- TRINITYJERD
667. Tile Staeink
6:7:1 Tile-shall be loaded and staged in a manner that prevents file slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for the staging.
6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and:FRSA/TRI April 2012(0442)must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed,.such as the use of'battens or nail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6J:4 For mail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for lo ding/ of lugged tile rep,diess of slope.
Battens are required for loading/staging of flat the at slopes in excess o'f.5:12. p
6:7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight
(48)hours.
I
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANuF;kcrURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.,Rule 61620-3 QA requirements.
9. QUAuTy ASSURANCE ENTITY:
UL,LLC=QUA5625;(314)578-3406;k.chancelior@us.ul.com i
-
END OF EVALUATION REPORT-