Loading...
HomeMy WebLinkAboutProduct Approval .. ,., ,, _\i -y.,sL'.�.'SMmTA.:+I�l:..��.&w:!1F.'idiiw:.Ak.'AaikYct..1 r f_... � � [1 _ _ 2 _ ,/ �� ...... � .. 'XIWILId nUIIU1ng uoae vruine I Page 1 of 2 fit �t}S�iW �.+�.��f� SCIS Home 1 Cog In ; User Registration Hot Topics j Submit Surcharge a Stats&Factsi Publications FOC Staff t BCIS Site Map i Links i 'Searcy. I I [' I Product Approval j USER:Public User it ii ,I Product Approval Menu>Product or Anollcation Search>Application List>Application Detail I ' FL# a L- FL2569-R12 Application Type Revision Code Version 2014 Application Status Approved I '' I; Comments Archived Product Manufacturer. Soprema,Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (819)478-2400 i memathieu@soprema.ca - � II Authorized Signature Marc-Etienne Mathieu j memathieu@soprema,ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memathieu@soprema.ca Quality Assurance Representative Jean-_Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggar Drummondville (888)811-3145 jfcote@soprema.ca i i it Category Roofing f�+ "I Subcategory Underlayments " Compliance Method Evaluation Report from a Florida Registered A Ichitect or a Licensed Florida Professional Engineei Evaluation Report-Hardcopy Received Florida Engineer-or Architect Name who developed Robert J. M. Nieminen i the Evaluation Report Florida License PE-59166 i Quality Assurance Entity UL LLC ' Quality Assurance Contract Expiration Date 07/17/2020 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL2569 R12 COI 2017 01'COI Niemine�df I I I I Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM D6163 2000 ASTM D6164 2005 FM 4474 2004 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995 TAS 110 2000 UL 1897 2004 i http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsK�QFEnckB 10... 11/1/2017 u .S:lullua nu11u1Ilg wue uniine Page 2 of 2 Equivalence of Product Standards Certified By I ' :Sections from the Code ,I Product Approval Method Method I Option D Date Submitted 06/1212017 Date Validated 06/13/2017 Date Pending FBC Approval 06/15/2017 Date Approved 08/08/2017 l' i Date Revised 10/09/2017` Summary of Products I FL# Model,Number or Description i Name 2569.1 , Soprema Roof Self adhering roof underlayments Underiayments Limits of Use Installation Instructions �'; �I Approved for use in HVHZ:No FL2569 R12 II 2017 06 FINAL ER SOPREMA 'CA UN ii FL2569- Approved for use outside HVHZ:Yes R12.adf II Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166 I Design Pressure:+N/A/-150 Created by Independent Third Party:Yes Other: 1.)Refer to ER Section 5 for Evaluation Reports j Limits of Use.2.)The design pressure FL2569 R12'AE 2017 06FINAL ERI SOPREMQ CA UNDERLAYMENTS FL2569 noted herein pertains to underlayment R12.Ddf systems used beneath adhesive-set tile Created by Independent Third Party:Yes i systems. Refer to ER Section.5.6.4 for ! I, details. I i Baek Next 1, Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 i The State of Florida is an AA/FFO.employer.Copyright 2007-2013 State of Florida ::Privacy State Statement::aer I.sibility Statement::Refund Statement I I � I, Under Florida law,email addresses are public records.Ir you do not want your e-mail address releaseld in response,to a public-records request,do not send electronic mail to this.entity.Instead,contact the office by phone or by traditional mail.If you have any questions„please contact 850.487.1395.*Pursuant to I Section 455.275(1),Florida Statutes,effective.October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.Howeverlemail addresses are puhlic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,FS.,please click here. ' Product Approval Accepts: I Credit Card Safe I - i II I http://www.floridabuilding-org/pr/pr_app_dtl.aspx?paraln=wGEVXQwtDgsKlQFEnckB 10... 11/1/2017 1 /✓ EXTERIOR RESEARCH&DESIGN, LLC. i`=•.,, 1 }I Certificate of Authorization#9503 a 353 CHRISTIAN STREET,UNIT#13 •,,' I ERD �I i OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT ' Soprema,Inc. Evaluation Report S18010.06.09-1110 1640 rue Haggerty FL2569-1112 I' Drummondville,Quebec J2C 5138 Canada Date of issuance:06/15/2009 (819)478-2400 ( Revision 10:06/12/2017 SCOPE: i I This Evaluation Report is issued under Rule 61G20-3 and,the applicable rules and regulations governing the use of construction,materials in the State of Florida.The documentation submitted Nasi been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Bui1cling Code, Residential Volume.. The products described_herein have been evaluated for compliance with the 5`h Edition 0014),Florida Building Code sections noted herein. i DESCRIPTION: Soprema Roof Underlayments a LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prodct(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes,agreement to notify Robert Nieminen, P.E. if the product u C:, changes or the referenced Quality Assurance documentation changes. Trinity ER, requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evailuated" may be displayed in advertising literature. if any portion of the Evaluation Report is displayed,then itishall be,done in' its entirety. I INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the`user by the manufacturer or its distributors and shall.be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: l 1 1. _..� "�� ��•t�� 1`^ter}• ! 01 Robertl.M.Nieminen,P.E. .. >,:•r ; The tacsimiteseat.appearing tijas authorized Ey Robert Nieminen, ,� ��`•. P.E.on 06/12/2017:This does not serve as an electronically signed IS Florida Registration No.59166,Florida DCA ANE1983 Nl;;4 document.5igned.'sealed hardcogres have been transmitted to the Product Approval'Administrator and to the named client i CERTIFICATION OF INDEPENDENCE: �;. 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial iinterest in'any company manufacturing or distributing products it evaluates. y l'. 2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it"evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company)manufacturing or distributing products for which the evaluation reports are being issued. } 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the 4 product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any ? project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I • ; i 4 i! "ITRINITYIERD ROOFING COMPONENT EVALUATION: ({ .1. SCOPE: :Product Category: Roofing {) Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, h Ilve demonstrated compliance with the following sections of the Florida Building Code through testing in accordance iwith the following Standards. Compliance is subject to the installation Requirements and Limitations/Condlitions off:Use set forth herein. 2. STANDARDS: Section Property Standard I III Year 1504.3.1 Wind Resistance FM 4474 2004 1504.3.1 Wind Uplift UL 1897 2004 1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009 1507.2.9.2,1507.4.5.1, I 1507.5.3,1507.7.3 I 1 1507.11.2 Physical Properties ASTM D6163 r 2000 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 TAS 110 Accelerated Weathering TAS 110 j 2000 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12)j 2012 3. REFERENCES: l I, i Inti Examination Reference 'I Date ERD(TST6049) ASTM D 1970/TAS 110 2968.05.04 2 i �a 05/14/2004 ERD(TST6049) Physical Properties 2757.02.051 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05 2 i 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05' 07/15/2005 a 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05 Rl I ; 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 S13190.0210'9-RI ;i 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 S31370.03'10-1-R1 i 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05 110 R2 13 09/09/2010 ERD(TST6049) physical Properties/Tensile Adhesion S11150.0510'9-R2 10/05/2010 ERD(TST6049) ASTM D1970 S37210.11111 11/09/2011 ERD(TST6049) ASTM D1970 S40540.02113-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02114-1 i 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 I ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-'Rl 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.041 ti 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 i; 05/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation'' Exp.10/16/2017 �I 4. PRODUCT DESCRIPTION: 4.1� Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced; SBS!modified bitumen roof I �G underlayment. 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. i i1 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven pc surfaced,SBS modified bitumen roof underlayment;available in 3.3 ft x 65 It rolls. Exterior Research and Design,U.C. Evaluation Report 518010.06.09-1110 Certificate of Authorization 0503 FBC NON-HVHZ EVALUATION FL2569-R12 Soprema,Inc. I 3 Revision 10.06/12/2017 Page 2 of 7 �I i 4.4 Lastobond Shield HT is aself-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene urfaced,,''SBS modified bitumen roof underlayment available in two widths;36 and 45 inch, I 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-siurfaced,�`ISBS modified bitumen roof underlayment. � -4.8 Lastobond Eaves Protection Sheet is a self-adhering,glass-mat reinforced sand!'surfaced, SBS modified bitumen roof underlayment. 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced,''SBS modified bitumen roof underlayment. 4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment. 4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced,?SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-matll'einforced,sand-surfaced,SBS ! modified bitumen roof underlayment,with a 36-inch sheet width. 4.13 RESISTO L81244 is a self-adhering, glass-mat reinforced, sand-surfaced;+SBS modified bitumen roof underlayment,with a 44-inch sheet width. •i 4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granulejsurfaced, SBS modified bitumen roof underlayment. ; S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert NiernIn, n, P"E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. i 5.3 Fire Classification is not part of this report, refer to current Approved Roofing Materials Directory for fire ratings of this product. 1 ; 1 5.4 Soprema Roof Underlayments may be used with any prepared roofIcover where the product is specifically referenced within FBC approval documents., If not listed,a request may be;made Fto the Authority Having Jurisdiction for approval based on this evaluation combined,with supporting data for the prepared roof covering. t 5.5 Allowable roof covers applied atop the underlayments are follows- TA ROOF COVER OPTIONS Asphalt Nail-On Foam-Ong !_r I+Wood Shakes& Underlayment Metal Slate i Shingles Tile Tile (! ,; Shingles ' Lastobond TU HT Yes Yes Yes Yes ! Yes Yes See 5.5.ill Lastobond Shield J Pro HT-N/ Yes No No I No Yes Yes RESISTO SA SMOOTH PLY 40 II i" Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes Lastobond Eaves Protection { 1''1 Yes No No f No Yes Yes Sheet/Lastobond 195 Exterior Research and Design,U.C. ! l Evaluation Report 518010.06.09-1110 Cervicate afAuthorization#9503 FBC NON-WKEVALUATION FL2569-R12 Sopretna,Inc. Revision 10:06112/2017 Page 3 of 7 i i' ERD TABLE 1 ROOF COVEROPTIONS ;( Asphalt Nail-On Foam-On I Wood Shakes& Underiayment wai Slate Shingles Tice Tile �) j Shingles Lastobond:ECO /RESISTO `l •-LMGfip=Rite Eave&-Valley Yes No No I INo Yes Yes Protector[RESISTO LB1244 . Iii Lastobond Smooth Seal HT Yes No No Yes Yes Yes I � Colphene FR GR Yes Yes Yes I) No Yes Yes See 5.5.1 1; 5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/long term aging data from an accredited testing laboratory is provided. I� , UnderlaymentAdhesives) Lastobond TU HT ECP Adhesives"Polyset AH-160"(FL6332);Dow Chemical"TileBond""a Roof Tile Adhesive"(FL717) Colphene FR GR ICP Adhesives"Polyset AH-160"(FL6332) '5.6 Allowable substrates are noted below: 5:6.1 Direct-Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to: Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primedIlOSB;Soothern',Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. ; ' Colphene FR GR applied to: li > Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. ' 'i Note: ! , v While'not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. I i} > Soprema requires tongue-and-groove board decking be co' ith plywood or OSB prior to installation of the self-adhering underlayment 5.6.2 Bond-to-Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond j195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector, RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR applied to: 9 Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof cove in s, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval For installations under foam-on tile systems (Lastobond TU HT only),insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix. s I I , r I Exterior Research and Design,LLC. Evaluation Report S18010.06.09-RIO Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION 1 ! FL2569-1112 Soprema,Inc. ii Revision 10:06/12/2417 Page 4 of 7 i TRI lTYERD 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY j40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 1195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-oh the systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12)': a 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications:; FRSA/TRI April 2012 (04-12)' does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind)uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on the applications. Maximum Design Pressure is the result of testing for wind load relsistancel based on allowable wind.loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 11 margin!of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 psf: I Deck: Min. 15/32-inch plywood to meet project requiremel is to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf: I' r Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. l Primer: Elastocol.600c + .j Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. � I 5.6.4.3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority HavinglJurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust-'and 'debris that may inhibit adhesion. All sheathing fasteners shall be driven flus' i with;the surface. All sharp j splinters and wood projections shall be removed%sanded', �l Primer: (Optional)RESISTO EXTERIOR PRIMER �I i Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly ;roll using hand roller and/or ! weighted roller to ensure there are no voids, and ensure'there'are no voids/bridging at j side and end-laps, i it 5:6.4.4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project regi irements to satisfaction of Authority Having Jurisdiction. �i Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch lap's and;,6-inch o.c, in three (3), j equally spaced rows in the center of the sheet. Underlayment: LastobondTU HT or Colphene FR GR,self-adhered 1 i 1 Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-1110 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.2569-1112 So rema,Inc. P � Revision 10:06/12/2017 Page 5 of 7 I I� a .I i TRINITY'ERD 5.7 Exposure Limitations: I ' Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco; Lastobond Smooth Seal HT, RESISTO L61236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be lelft exposed for longer than 30- days after installation. i Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond!,Shield HT or Lastobond I Pro HT-S shall not be left exposed for longer than 90-days after installation Lastobond TU HT or Colphene FR GR shall not be left exposed for longerthan 180-hays after installation. 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the''�specifcs noted below. II I 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate{with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER(if applicable).6_3 Lastobond TU HT.Lastobond Shield Lastobond Pro HT-iU RESISTO SA SM10! OTH PLY 40 Lastobond Shield HT, Lastobond Pro HT-S, Lastobond Eaves Protection Sheet, Lastobond 1'95, Lastobond Eco Lastobond Smooth Seal HT,RESISTO LB1236 Grip-Rite Eave&Valley Protector RESISTO LB1,244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM, D1970�lunderlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: While priming is optional, Soprema recommends priming with Ela�stocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft'of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in. place, peel-off the reliease film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. I,! Horizontal seams should be minimum 3-inches, configured to shed water,: Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course blelow. All over-granule end-laps shall be sealed using either heat-welding or hot air welding technlgues. When installing at slopes above 8:12, Soprema recommends backinailing in-the overlap area at the top of the sheet at 12-inch o.c. I I I For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the,irelease paper and center sheet over valley or ridge. Drape and press sheet into place, working from the(center of the valley or ridge in each direction. For valleys,apply the sheet starting at the'lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR oniv): i Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual .and Table 1 herein, using the Iinstructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6:4 herein for Wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. i y Exterior Research and Design,LLC. Evaluation Report 518010.06.09-1110 Certificate of Authorization#95a3 FBC NON-HVHZ EVALUATION i, I F1.2569-1112 Soprema,Inc. Revision 10:06/12/2017 "I Page 6 of 7 than these limitations,all tiles shall be loaded onto a nominal V 2"horl I z6ntal 6atten to prevent slippage |