FL #
FL10674-R12
Application Type
Revision
Code Version
2014
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
V Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL10674 R12 COI 2016 01 COI Nieminen.odf
Standard
ASTM D3161
ASTM D3462
ASTM D7158
Year
2009
2009
2008
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/18/2016
Date Validated 04/19/2016
Date Pending FBC Approval 04/20/2016
Date Approved 06/08/2016
Date Revised 10/10/2017
Summary of Products
FL # Model, Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge shingles
Shingles and Starters
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Installation Instructions
FL10674 R12 II 2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R12.odf
Impact Resistant: N/A
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES F1_10674-R12.Ddf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
W eCh
Credit Card
Safe
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization 119503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.02.12-R7
FL10674-1112
Date of Issuance: 02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
Or
• 1
•%,�'��+'= C ? tv.lrs�
The facsimile seal appearing was authorized by Robert Nieminen,
,�'��,S�iQ U �,L',.•`�
P.E. on 04/18/2016. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2008
3. REFERENCES:
Entity
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Control
Service Confirmation, R2453
Exp. 08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme® are fiberglass reinforced, 3 -tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles.
4.1.3 Devonshire'" are fiberglass reinforced, 5 -tab asphalt roof shingles.
4.1.4 Duration", Tru Definition® Duration®, Duration Premium Cool, Tru Definition® Duration Designer Color
Collection, TruDefinition�Oakridge ®, Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgell Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 FL10674-R12
Revision 7: 04/18/2016
Page 2 of 8
TRINITY I ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are
acceptable for use in all wind zones up to Vasd = 150 mph (Vit = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlavment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshirem shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
➢ Devonshire'" shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing — Starter Strip Shingle and Starter Strip Plus:
Felt underlaytnent
Deck
Self -adhered
WeatherLod&
underlaynsent
Drip edge
;J
� 4 �
Nails located
2"'-3' from save
krataR first
SelFseafing adhesive
Starter
=
shingle6'rernoved
positioned along esus
Starter Strip shingle overhangs eaves and rakes V -V
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Fett underbyment Dat Se"hered
weaned "
undedayment
Drip edge
edge
t' ftallslocatad
2'49"ftonteeve
Nstall first Starter Strip PWsSdkodkvg &&asivs
with rremoved alongpositioned save
Starter Strip Pkn ovwMnps eaves and rakes 114'-314"
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 3 of 8
6.2.6 Minimum Nailing — Classic' & Supreme:
Normal Mansard or Area para
Wind Areas High Wimd desvanes y
Area pare vionto" nerrnaies Areas vientas tuerres
(A) �" �' Y'
S`Exposure
Exposicidn
6.2.7 Minimum Nailing — Berkshire':
Sealant strip
La lira de ,eBador
V, R VP � R VI
Standard Fastening Pattern
Normal Mansard or Area para
Wind Areas High Wind desvenes y
Area pare vientos norma$" Areas vfentos fuertes
5 5i8' Exposure
Exposicidn
6 -Nail Fastening Pattern
Sealant strip
La trra de saffador
8 I 8„t 8 i421 8ir211
r
r
1 ~ Asphah ro0ingoemeni
Comato de who do istafto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Certificate ojAuthoriration #9503 F1.10674-1112
Revision 7: 04/18/2016
Page 4 of 8
6.2.8 Minimum Nailing — Devonshire'"':
7w 8" 8" 8- 7-
1.
I
W8" exposure Sealant location
Exposki6n de 5 -5/8 ping Ubicaci6n del sallador
Standard 6 -Nail Fastening Pattern
RINITY ER
Nails
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition" Duration®
Designer Color Collection:
4 -Nan Fastening Pattern
aunweoft"W a awe wltlm
wi6 baler
N, w
Standard Fastening Pattern
Exterior Research and Design, LLC.
Certificate of Authorization #9503
"all Fastening Pattern
Su�Hulo taerobv a wam
wii, rypied
y^ 12^ tr t
6 -Nail Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Evaluation Report 037940.02.12-117
F1.10674-1112
Revision 7: 04/18/2016
Page 5 of 8
6.2.1 Minimum Nailing —TruDefinition�Oakridge®, Oakridge®:
4 Nail Pattern
Esquema con 4 clavos
y. 1.
I� V — ►I I'r— 12-
-vl
5 5!8" Exposure Nails 5 518" Exposure
Erposicinude5619pulg. Ctavas Exposicionde6516pulg.
Standard Fastening Pattern
6 Nail Pattern
Esquema con 6 cfavos
t y.
55/8" Exposuie Nails 55/8' Ex Po -
sure
Claws
Exposiddn de 5 5/e pulg. Exposicion de 5 64 ping.
6 -Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
SucNF�9 aaanttt�RrRa.wm
i r
N.1, Typ I
,.;,..-,.-� .. — ___ _1 Fnxy it • I
ltlf 33,'6"
Fou t" Spots of NPhsn Roon+lg C`isfMfit
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing — WeatherGuard® HP:
Exterior Research and Design, LLC.
Certificate of Authorization #9503
single site View
FmIum 71rwmoh NO Lir
Ci6manifMum ♦ A
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 6 of 8
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuarda HP Hip and Ridge Shingles and
ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidgel" Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Fig. 2
Top View 9d.'Am
Nails Nails
TT Top Laminated 2"
3" BCQ I
1 !
Ir.
! I
!
i
-- - __
12-
6.3.4
z -
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Fig. A q v
P[evanYg wind
lNnaclbn C�`` A
Nails
A 1 I
1 I
I I
Exp sary
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Fig. C Hip & Ridge Shingle Fastening
Top view
Nails Nails !
•
i
i
Exposure i
! _ IJ
12
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction Seelent strip
A--' 6' Expense
Fades 7'h"
Cevw Exposed
Fasteners whh
Rea# Cement
Standard 11'�
F�rnning
12' Sealant
6" Exposure
12-
6.3.6 Minimum Nailing — Dura Ridge" Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Top Ykw
Yue M Pkh
i^ Vista superior �.
Ka
90
cis
I
I
'J J
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625 ; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 FL10674-1112
Revision 7: 04/18/2016