Loading...
HomeMy WebLinkAboutProduct Approval (2)BC1S Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BC1S Site Map Links WINdby�r Product Approval 4USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL9777-R9 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed F Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report ASTM D 1970 Florida License PE -74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Validation Checklist - Hardcopy Received FL9777 R9 COI OCR14002.6a FBC 2014 Evaluation Report Weather Non-HVHZ FINAL.pd Standard Year ASTM D 1970 2009 ASTM D 226 2006 ASTM G 155 2005 TAS 103 1995 UL 1897 2004 Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL # Model, Number or Name 9777.1 Weatherlock G Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. 9777.2 WeatherLock G (High Tear) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. .................................. 9777.3 Weatherlock MAT Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. 9777.4 Weatherlock MAT Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. 9777.5 WeatherLock Metal Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Method 1 Option D 04/12/2017 04/12/2017 04/13/2017 06/13/2017 jDescription Weatherproofing Underlayment Installation Instructions FL9777 R9 II OCR14002.6a FBC 2014 Evaluation Repor Weatherlock Non-HVHZ FINAL pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R9 AE OCR14002.6a FBC 2014 Evaluation R pc Weatherlock Non-HVHZ FINAL.pdf Created by Independent Third Party: Yes Weatherproofing Underlayment Installation Instructions FL9777 R9 II OCR14002.6a FBC 2014 Evaluation Repor Weatherlock Non-HVHZ FINAL pdf Verified By: Zachary R. Priest PE -74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R9 AE OCR14002.6a FBC 2014 Evaluation Repc Weatherlock Non-HVHZ FINAL pdf Created by Independent Third Party: Yes Waterproofing Underlayment Installation Instructions FL9777 R9 II OCR14002.6b FBC 2014 Evaluation Repor Weatherlock HVHZ.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R9 AE OCR14002.6b FBC 2014 Evaluation Repc Weatherlock HVHZ.pdf Created by Independent Third Party: Yes Waterproofing Underlayment Installation Instructions FL9777 R9 II OCR14002.6a FBC 2014 Evaluation Repor Weatherlock Non-HVHZ FINAL pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R9 AE OCR14002.6a FBC 2014 Evaluation Repc Weatherlock Non-HVHZ FINAL pdf Created by Independent Third Party: Yes Weatherproofing Underlayment Installation Instructions FL9777 R9 II OCR14002.6a FBC 2014 Evaluation Repo Weatherlock Non-HVHZ FINALpdf Verified By: Zachary R. Priest PE -74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R9 AE OCR14002.6a FBC 2014 Evaluation Repc Certificate of Authorization No. 29824 CREEK17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL_ SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 5T" EDITION (2014) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 12, 2017 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www.owenscorning.com Manufacturing Location: Brentwood, NH Houston, TX Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3, 1507.7.3.2 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) NEI -039-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) NEI-042-02-01REV2 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) NEI -045-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI -045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST6049) NEI -053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI -053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST6049) NEI -093-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST6049) OCF-237-02-01 UL 1897 2004 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies (TST6049) OCF-252-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) OCF-296-02-02 ICC -ES AC 188' 2012 ICC -ES AC 48 2012 PRI Construction Materials Technologies (TST6049) OCF-297-02-01.1 ASTM D 1970 2009 'Determined to be equivalent to ASTM D 226-06, Type I and II OCR14002.6a FL9777-R9 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock@ Self -Sealing Ice & Water Barriers WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2 -sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft. WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@) Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1 - Houston, TX) sq. rolls with nominal dimensions of 3 -ft x 33.3 -ft and 2 sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft. WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@) Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3 -ft x 66.7 -ft. WeatherLock@ Metal is permitted to be used with mechanically fastened asphalt shingles, metal roof panels or shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. (Brentwood, NH) The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-11 x 71.3 -ft. WeatherLock@) Specialty Tile & Metal is permitted to be used with mechanically fastened asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 (3M Company) or TILE BONDTm Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock@ G (High WeatherLockO G (High Tear) is a self -adhered, underlayment used as an alternative to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer (Houston, TX) modified bitumen underlayment. The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95 -sq rolls with nominal dimensions of 3 -ft x 65 -ft. WeatherLock@ G (High Tear) is permitted to be used with mechanically fastened asphalt shingles, metal roofing, slate shingles, wood shingles and wood shakes as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.6a FL9777-R9 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT APPLICATION OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers Min. Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail the underlayment 12 -inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 — WeatherLock Specialty Tile & Metal Only Roof Deck: Min. 15/32 -inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1 -1/4 -inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1 -5/8 -inch 0 tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -105 psf Pressure: OCR14002.6a FL9777-R9 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers A TECHNICAL SERVICES, LLC GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 5th Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer. R. p ri No 74021 _— O'.•• STATE OF : ,U P .•' _ . 10 ' / � IIIN Ai E CERTIFICATION OF INDEPENDENCE 2017.04.12 15:15:46 Oymry agnea er E.ei.r 0. p,ee, -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.6a FL9777-R9 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.