HomeMy WebLinkAboutProduct Approval B
usiness & Professional
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FOC Staff 8CIS Site Map Links Search
b
a
*Product ApprovalUSER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail E
FL# FL18355-R2 �� � ��
Application Type Revision
Code Version 2014 Pr_R:/ilk i Ir1Ci
Application Status Approved St. Lucie COJ,It\f, ,_,_
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc. c
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden @tamko.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
-_ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
-- Validation Checklist-Hardcopy Received
Certificate of Independence FL18355 R2 COI TBP15001.2 FBC 2014 Product Evaluation Report
Shingles.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 3161 2009
ASTM D 3462 2009
ASTMD D 7158 2008
TAS 100 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method i Option D
Date Submitted 12/16/2015
Date Validated 12/18/2015
Date Pending FBC Approval 12/19/2015
Date Approved 02/10/2016
Date Revised 05/09/2017
Summary of Products
FL# Model,Number or Name Description
18355.1 Glass-Seal, Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Vintage, Hip and Ridge,and Vintage
Hip and Ridge Shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL18355 R2 II TBP15001.2 FBC 2014 Product Evaluation_
Approved for use outside HVHZ:Yes Report ShinDles.odf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL18355 R2 AE TBP15001.2 FBC 2014 Product Evaluation
.RRR%lort hingles.Ddf
Created by Independent Third Party: Yes
Back Nez
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Ftorida is an WEED employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
—
lilts. il-00-1 Khcl E
Credit Card
Safe
CREEK
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5T"EDITION(2014)
Manufacturer: TAMKO BUILDING PRODUCTS Issued December 14, 2015
220 West 4`h Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick. MD
Dallas,TX
Tuscaloosa,AL
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties,Wind Resistance,Wind Driven Rain
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1
PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995
UL LLC(TST9628) 02NK9507 ASTM D 3161 2009
UL LLC(TST9628) 04NK24366 ASTM D 3462 2009
UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1
UL 2390
ASTM D 7158 2008d
UL LLC(TST9628) 06NK03898 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 08CA59132 ASTM D 3161 2009
UL LLC(TST9628) 09NK07896 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 10CA50498 ASTM D 3462 2009
UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2009
UL LLC(TST9628) 11 NK14014 ASTM D 3161 2009
ASTM D 3462 2009
UL LLC(TST9628) 12CA24551 ASTM D 3161 2009
UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1
UL LLC(TST9628) 4787043752 ASTM D 3161 2009
UL LLC(TST9628) 4787148748 ASTM D 7158 2008d
ASTM D 3161 2009
ASTM D 3462 2009
TBP15001.2 FL18355-R2 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass-Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass-Seal 12-1/4"x 36", ASTM D 7158. Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg & complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg & complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 12" x 36 ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage®Vintage(D 17-1/2"x 40",ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced.
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas &Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritages Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.2 FL18355-R2 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
INSTALLATION
Elite Glass-Seal@ Basic Wind Speed(V,d,): Max. 194 mph
(Frederick,Joplin& Basic Wind Speed(V w): Max. 150 mph
Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Glass-Seal new construction; Min. 15/32 in. plywood existing
(Frederick,Joplin(Non- construction.
HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Undedayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattem"or"6 Nail Pattem"detailed below.
NAILS
w
Nailing-; -.. . .... _................. ................
._.._.....------...... . . fr7/s"
Area - ---------------.....-------------------......------.......-.......---------------....
5-118"
Hutt Edge
Figure 1. Elite Glass-Seal&Glass-Seal
4 Nail Pattern (Non-HVHZ only)
NAILS
Nailing _ ....__......._......-...... -.......- ► ..... __..... - 6-7/813
Area --.......-__....--_...-.__......_................. ......- _......_
5-118"
Butt Edge
Figure 2. Elite Glass-Seal&Glass-Seal
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
Lam
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
Heritage® Basic Wind Speed (V,,,,): Max. 194 mph
(Dallas, Frederick,Joplin, Basic Wind Speed (Vasa): Max. 150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Heritage®Premium new construction; Min. 15/32 in. plywood existing
(Dallas, Frederick construction.
Phillipsburg &Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements;
& Solidly sheathed min. 15/32 in. plywood or wood plank for
Heritage®Woodgate new construction; Min. 7/16 in. OSB existing construction.
(Dallas&Frederick) Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-518 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either A Nail
Pattern"or"6 Nail Pattern"detailed below.
FASTENERS NAIL ZONE
j:��/COMMON
BOND
10S
URE 5-5/8"
1 "
12-1/211-►� 12-3/8" -► - 12-1/2` �--V
Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
FASTENERS NAIL ZONE
COMMON
BOND
6-1/8" EXPOSURE 5-5/8"
1"—►, r-1/2" - -1/2"-►� 7-3/8"-0} -7-1/2"-►h-r-1/2`�
Figure 4. Heritage®& Heritage®Premium
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
PRODUCTS
TAMKO BUILDINGAsphalt Shingles
TECHNICAL SERVICES,LLC
NAIL ZONE/
STENERS7 COWON BOND
t f T
RE 5 5/8"
EXPOSURE
1:1--q �7-1i2'+7-1/2-444--7-3/8+7-1/2+7-1/2a� 1
Figure 5. Heritage®Woodgate
6 Nail Pattern
12-1/2"
FASTENERS Common Bond
7
C,
LA 0 7
CL (0
X
W
Figure 6. Heritage®, Heritage®Premium, & Heritage®Woodgate
Alternate 6 Nail Pattern
PAI NT
LINE
7-7/811 ZONE
---EDGE OF
COMMON
BOND
EXPOSURE
5-5/81,
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
—-------------- ---------- COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage® (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.2 FL18355-R2 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for Mich this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
Heritage®Premium Basic Wind Speed(VW,): Max. 194 mph
(Frederick) Basic Wind Speed(Va�d): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Undedayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"4 Nail
Pattem"or"6 Nail Pattem"detailed below.
NAIL ZONE/
FASTENERS /COMMON BOND
51/2" EXPOSURE 5"
Figure 8. Heritage®Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERS /COMMONBOND
51/2" EXPO RE 5"
Figure 9. Heritage®Premium (Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODUCTS
CREEKAsphalt Shingles
TECHNICAL SERVICES, LLC
Heritage®Woodgate Basic Wind Speed (V"it): Max. 194 mph
(Frederick) Basic Wind Speed(Vag,): Max. 150 mph
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either'4 Nail
Pattern"or"6 Nail Pattern"detailed below.
NAIL ZONE:
FASTENERS COMMON BOND
T
EXPOSURE 5"
12-3/8"— —
Figure 10. Heritage®Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONE/
FASTENERS COMMON BOND
t
5-1/2 EXPOSURE 5'
9-1/2"—43' -9-3/8 ►*34 9-1/2"
Figure 11. Heritage®Woodgate (Frederick)
6 Nail Pattern
TBP15001.2 FL18355-R2 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Heritage@ Vintage@ Basic Wind Speed(Vut): Max. 194 mph
(Phillipsburg) Basic Wind Speed(Vasa): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Undedayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturers published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"5 Nail
Pattern"or"6 Nail Pattern"detailed below.
aa'
yFxPOSUM
T Nuech
6., Fasteners ►Sil
— — — — — — — — — — — ♦ — — — —
17.1l2"
S"
1 posu re
4-6
41a— -41n vin otn ;
>,
�+--101W---I
Figure 12. Heritage®Vintage®
5 Nail Pattern (non-HVHZ only)
40r Expmm
i NWdf
Q� n Nd
- - - Zara
17-1/2'
r
erpo�uA
—Figure-+113. Heritage®Vintage°
6 Nail Pattern
TBP15001.2 FL1B355-R2 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES,LLC
Hip&Ridge Basic Wind Speed(Vui): Max. 194 mph
(Frederick&Joplin) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction;Min.7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start 5-1/8" exposure
here—
start II
Figure 1 here 5-1/8"exposure
lop V
? Fastener ? Fastener
Figure 2 1/41'
/4n Figure 3
Figure 14. Hip &Ridge (Frederick&Joplin)
TBP15001.2 FL18355-R2 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
r CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
Vintage®Hip& Ridge Basic Wind Speed(V,,,,): Max. 194 mph
(Phillipsburg) Basic Wind Speed(Vasd): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements.
Installation: Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
Start 5" exposure
here—
�'
Start
here y' exposure
Figure 1
Fastener
I Fastener
Figure 2 1/4�� Figure 3
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
TBP15001.2 FL18355-R2 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 33-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 51"Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
��►tttta'►iii
`,`,G�PaY R 2 015.12.14
No 74021 13:44:19
•* _ �,..�.��,..� -05'00'
STATE OF �4J
Zachary R. Priest, P.E.
S O R Florida Registration No. 74021
,5`0NA;� `�� Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.2 FL18355-R2 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
( EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization#19503
TRINITY f ERD F9EC 1 201? 353 CHRISTIAN STREET, UNIT#13
P;.R"�?i3�liJG OXFORD, CT 06478
St. !ucie County, FL (203) 262 9245
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R22
150 Lyon Drive Y s" ei> FL5259-R26
Fernley, NV 98408 x # ' Date of Issuance: 02/24/2009
(570)384-1230 ;, Revision 22:03/13/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5t6 Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
The facsimile seal appearing was authorized by Robert Nieminen,
P.E.on 03/13/2017. This does not serve as an electronically
Robert J.M. Nieminen, P.E. signed document. Signed,sealed hardco ies have been
Florida Registration NO.59166,Florida DCA ANE2983 ✓r.;� ;`+ transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 50 Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prone Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1504.3.1 Wind Uplift UL 1897 2004
1504.6 Accelerated Weathering ASTM G154 2006
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006
1507.8.3,1507.9.3
1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009
1507.11.2 Physical Properties ASTM D6164 2005
1507.11.2 Physical Properties ASTM D6222 2008
1507.3.3 Installation Practice FRSA/TRI April 2012 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
En�tit L Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST 5878) Physical Properties PRIO1111 04/08/2002
PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002
PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002
PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005
PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006
PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006
PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008
PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009
MTI(TST 2508) Physical Properties 1X20H7A 04/01/2008
MTI(TST 2508) Physical Properties RX14E8A 01/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003
ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007
ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008
ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009
ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009
ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010
ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FOC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 2of14
TRINITY ERD
Entity Examination Reference Date
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.04/24/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
4.2 Self-Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,surfaced
with polyolefinic film surface;meets TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly-film surface;meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,with an
aggregate surface;meets ASTM D1970.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization x/9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc Revision 22:03/13/2017
Page 3 of 14
TRINITY ERS
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface;meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m' polyester
fabric surface;meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet ASTM D6222.
4.2.8 Polystick Dual Pro" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.9 Polystick Tile Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.10 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of an sand-surfaced SBS
modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the'Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the `Two Ply System"from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization x9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 4 of 14
TRINITY ERD
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Shingles Nall-0n Tile Foam-0Wood Shakes Slaten Tile Metal &Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Elastobase P Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base sheet In 2-ph system)
Polyglass G2 Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply m)
Yes Yes No No No
Polyglass APP Base No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Polystick MTS Yes Yes No Yes Yes Yes
Polystick MTS PLUS Yes Yes No Yes Yes Yes
Polystick IR-Xe Yes No No No Yes Yes
Polystick TU P Yes Yes Yes (See 5.5.1) No Yes Yes
Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick Dual Pro Yes Yes No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes (See S.5.1) Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes Yes
Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes
Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes
or SA-APP Cap Sheet(FR)
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS)
Florida Product
Adhesive Underlayment
Approval s
Convenience Products'Touch'n
FL14506 Polystick TU Plus,Polystick TU Max
Seal StormBond Roof Tile Adhesive
Dow TileBondTM FL717 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset°AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap
FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap
FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polyglass PolyLok Roof Tile FL17855 Polystick TU Plus or Polystick TU Max
Adhesive
t Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-1122
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 5 of 14
T' T�INITY ERD
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations),Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods 'ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered
to:
ASTM C1289, Type ll, Class 1 polyisocyan u rate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
'- Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P or Mule-Hide Nail Base.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section 5.6.4 herein,or as tested in
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 6of14
TRINIl1( ERD
5.6.4.1 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet (FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga. x
lY<"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.4.3 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR), self-adhered and back-nailed within the selvedge-edge side laps using 12 ga. x
1'/,"ring shank nails through 32 ga., 1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.5 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG 100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.6 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.7 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.8 Maximum Design Pressure=-37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 7 of 14
TRINITY ERD
5.6.4.9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt.
5.6.4.10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Poly-flex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
5.6.4.11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot
asphalt.
5.6.4.12 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.13 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.14 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.15 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 8 of 14
QrTRINI-fy ERD
5.6.4.16 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.17 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.18 Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.19 Maximum Design Pressure=-75 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underloyment)
Fasteners: Dekfast#14 with Dekfast Hex plates, OMG #14 HD with CMG 3"Galvalume Steel Plates, CMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.20 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.21 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3" Round Metal Plates or CMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.22 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 9 of 14
TRINITY ERD
5.6.4.23 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underloyment)
Fasteners: Dekfast#14 with Dekfast Hex plates, OMG#14 HD with OMG 3"Galvalume Steel Plates, OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.24 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.25 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.26 Maximum Design Pressure=-112.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.27 Maximum Design Pressure=-120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied-
S.6.4.28 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.29 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FLS259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 10 of 14
TRINITY ERS
5.6.4.30 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS,TU P,TU Plus, TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as
set forth in Section 5.3, Note 1 of ASTM D1970-09,should be established as to slip resistance.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self-adhered, Elastoflex G TU,
Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied.
6.3.3 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization 89503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 11 of 14
,, TRINITY ERD
6.4 Polystick MTS,MTS PLUS, IR-Xe,TU P,TU Plus,TU Max,Dual Pro,Tile Pro or MU-X or Polyflex SAP,Polyflex SAP FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR):
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
Note: Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM
D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and
seller,as set forth in Section 5.3, Note 1 of ASTM D1970-09,should be established as to slip resistance.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter
metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back-nailed.
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 Ib. hand = 4
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of T
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric). ="
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps(min. 28 Ib roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick 1R-Xe or Polystick MU-X):
Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.4 herein.
For nail-on tile systems over Polystick MTS, battens are required for loading/staging of the tile.
For nail-on tile systems over Polystick MTS PLUS:
Battens are required for loading/staging of lugged tile regardless of slope.
i Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 12 of 14
TRINITYERD
6.4.4 Two(2)Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under
foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is
allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in the applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System"from FRSA/TRl April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet' in the'Two Ply System"from FRSA/TRl April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply
System" from FRSA/TRl April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied"Cap Sheet' in the'Two Ply System"from FRSA/TRl April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRl April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet'in the`Two Ply System"from FRSA/TRl April 2012(04-12) beneath mechanically fastened the
roof systems.
6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in the applications:
✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet' in the'Two Ply System"from FRSA/TRI April
2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied applied "Cap Sheet' in the 'Two Ply System" from
FRSA/TRl April 2012(04-12)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end
laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
Exterior Research and Design,U.C. Evaluation Report P32060.02.09-R22
Certificate of Authorization#9503 FBG NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 13 of 14
T' TR1N1TYi:ERD
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6.7.4 For nail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight
(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 14 of 14