Loading...
HomeMy WebLinkAboutProduct Approval Certificate of Authorization No. 29824 17520 Edinburgh DriveCREEK Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 5T"EDITION (2014) Manufacturer: ALPHA PROTECH ENGINEERED PRODUCTS, INC. Issued June 22, 2015 301 South Blanchard Street Valdosta, GA 31601 (229)242-1931 http://www.alphaprotech.com ��� Manufacturing Locations: Valdosta, GA DEC 0 6 2011 Quality Assurance: RADCO, Inc. (QUA1990) PEh:1�I1'TI�dG SCOPEt. Ccunt L Category: Roofing , Subcategory: Underlayments a Code Sections: 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, 1507.8.3, 1507.9.3 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) AEP-017-02-01 ASTM D 226 2006 ASTM D 4869 2005e1 RADCO, Inc(TST1987) RAD-5212 AC 188 2012 Ramtech Laboratories,Inc.(TST6127) 13075-04-08 AC 188 2012 PRODUCT DESCRIPTION REXTM' SynFelt A mechanically attached,woven polypropylene underlayment(nominal weight=2.56 Ib/100ft2)used an alternative to ASTM D 226,Type I and Type II roofing underlayments, REXtreme A mechanically attached, woven polypropylene underlayment(nominal weight=2.97 Ib/100ft2)used an alternative to ASTM D 226, Type I and Type II roofing underlayments TECHNOply A mechanically attached, woven polypropylene underlayment(nominal weight=2.05 Ib/100ft2)used an alternative to ASTM D 226,Type I and Type II roofing underlayments TECHNO SB A mechanically attached,woven polypropylene underlayment(nominal weight=2.00 Ib/100ft2)used an alternative to ASTM D 226,Type I and Type II and ASTM D 4869, Type 11 and IV roofing underlayments APPLICATION INSTRUCTIONS Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Min. slope: 2:12. For slopes less than 4:12, the underlayment must be half-lapped a full 24" over the underlying course. Attachment method: Underlayment shall be attached in accordance with the FBC and manufacturer's installation instructions. At minimum, mechanically fastened with min. 12 ga. corrosion resistant ring shank nail with min. 1-inch diameter corrosion resistant round cap to a min. 3/4-inch penetration, 8" o.c. at side and end laps and 24" o.c in a staggered pattern along the center lines printed on the sheet. The side laps shall be a minimum 3" wide APT15001.1 FL12512-R4 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. a CREEK ALPHA PROTECH ENGINEERED PRODUCTS,INC. Underlayments TECHNICAL SERVICES, LLC and minimum 6"wide at the end laps. The underlayment is installed starting at the eave, with the length of the roll parallel to the eave with the printed side facing up. All side laps shall be installed to shed water from the deck. Allowable roof coverings: Asphalt shingles, slate shingles, clay and concrete tiles, metal roof panels and shingles, wood shakes and shingles LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance is not within the scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 7) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 8) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 9) Contact the manufacturer when installing at temperatures below the minimum application temperature. 10) The underlayment may be used as described in other current FBC product approval documents. 11) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 12) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 13) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 5th Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer. G\PRY R •p9/�c'�. 2015.06.2 No 74021 213:55:44 —04'00' STATE OF %�T••.�� O P.•���� Zachary R. Priest, P.E. �,�s •• • R 1, Florida Registration No. 74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT APT15001.1 FL12512-R4 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. s i , OPY MMM MIAMI-DADE COUNTY tme PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) _ www.miamidade.eov/economy V , TAMKO Building Products,Inc. s'`' 220 West 41 Street DEC J � �GS� Joplin,MO 64801 PER?fill"i t,'�:G SCOPE: St. Lucie Count:. FL This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Roof Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.15-0709.19 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. 4y4k NOA No.: 15-1215.10 MIAMMADE COUNTY Expiration Date: 12/01/20 E M Approval Date: 05/26/16 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck TyRe: Wood SCOPE This approves TAMKO's Heritage,Heritage Woodgate and Heritage Premium asphalt shingles,manufactured by TAMKO Building Products,Inc.,as described in this Notice of Acceptance and designed to comply with the Florida Building Code High Velocity Hurricane Zones. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Heritage 131/4"x 39 3/8" TAS 110 Dimensional asphalt shingle. Manufacturing Location #1, 2, 3 Heritage Woodgate 131/4"x 39 3/8" TAS 110 Dimensional asphalt shingle. Manufacturing Location #1,3 Heritage Premium 131/4" x 393/8,, TAS 110 Dimensional asphalt shingle. Manufacturing Location # 1, 2, 3 MANUFACTURING LOCATIONS 1. Dallas,TX 2. Tuscaloosa,AL 3. Frederick,MD EVIDENCE SUBMITTED Test Agencx Test Identifier Test Name/Revort Date Underwriters Laboratories, Inc. TAS 107&UL 790 04CA44252 02/25/05 ASTM D3462 02NK33813 09/23/02 ASTM D 3462 &TAS 107 R2919 Letter 03/10/11 ASTM D3462 4789110543 08/26/14 TAS 107 02/19/15 ASTM E 108 08/26/14 ASTM D3161, Class F 4787043752 10/20/15 PRI Asphalt Technologies, Inc. TAS 100 TAP-129-02-01 05/26/05 TAS 100 TAP-130-02-01 05/26/05 TAS 100 TAP-131-02-01 05/26/05 PRI Construction Materials Technologies LLC TAS 100 TAP-303-02-01 12/12/14 TAS 100 TAP-307-02-01 02/10/15 TAS 100 TAP-317-02-01 09/02/15 MIAMFDiADE COUNTY NOA No.: 15-1215.10 Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 2 of 6 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shingles shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115. 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail `A',attached. 5. Nailing shall be in compliance with Details'B', attached. LABELING Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved"or with the Miami-Dade County Product Control Seal as seen below: 9M:1:90KOUNTY . .• BUILDING PERMIT REQUIREMENTS As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. NOA No.: 15-1215.10 MIAMMAD,COUNTY Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 3 of 6 DETAIL A HERITAGE,HERITAGE WOODGATE,AND HERITAGE PREMIUM All dimensions are in inches. 5TH COURSE 4TH COURSE 3RD COURSE 2ND COURSE 23 1ST COURSE 29 Full DETAIL B HERITAGE SHINGLE FIG. 1 FASTENING PATTERN All dimensions are in inches 39-3/8" _I 47 1" 7'/i' 7'/2" 73/811 7 1/2 7'/2" 1"- 13-1/4„ BI� >I��I��I��I� =�H - ------ ----- --•-----•-•------- - - ------------ ---- ::i'..... ...... ..............!..........._.------ ......................... Exposure fir NOA No.: 15-1215.10 MIAMFDADE COUNTY Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 4 of 6 DETAIL B (CONTINUED HERITAGE SHINGLE FIG. 2 ALTERNATE FASTENING PATTERN 12112"' 1 i i t Gprnman Bond FASTENERS 9 i 4 39-30HERITAGE SHINGLE (TUsCALOOSA,AL) FIG. 3 ALTERNATE FASTENING PATTERN HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG. 1 OR FIG.2. VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE. PAINT LINE.. 7-718 -- - ---Ifi1ML Z7N1= COMMON S i BOND EXPOSURE 5-5/811 ACCEPTABLE FASTENER LOCATION DO NOT FASTEN ALONML MON t+GE tD PREFERRED FASTENER LOCATION NOA No.: 15-1215.10 MIAMI•DADECOUNTY Expiration Date: 12/01/20 ` Approval Date: 05/26/16 Page 5 of 6 HERITAGE WOODGATE & HERITAGE PREMIUM SHINGLES FIG. 4 FASTENING PATTERN All dimensions are in inches 39-3/8" _I BIZ I6I / 7%" 1" � >1< � — IH 13-1/4" ------ -------- ------------------------------------------------- Exposure END OF THIS ACCEPTANCE NOA No.: 15-1215.10 MIAMFDADE COUNTY H, Expiration Date: 12/01/20 Approval Date: 05/26/16 Page 6 of 6