Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
M(AMI•DADE MIAMI-DADE COUNTY e PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) WWW•miamidade.Qov/economy PGT Industries 1070 Technology Drive, ,DEC 1 2 2017 North Venice,Fl.34275 PR!'ili 17, G SCOPE: St. Lucie C This NOA is being issued under the applicable rules and regulations governor%"ftdFsb of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"5470"Vinyl Sliding Glass Door(Reinforced)-N.I. APPROVAL DOCUMENT: Drawing No. SGD-5470,titled"Vinyl Sliding Glass Door NOA",sheets 1 through 19 of 19,prepared by manufacturer,dated 10/05/15, signed and sealed by Anthony L.Miller,P.E.,bearing the Miami-Dade County Product Control Renewal stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:None: Approved Hurricane Protection devices,complying w/FBC,as applicable are required. Limitations: 1. See table 1(sheet 7)and table 2(sheet 8)of this approved drawing set for applicable SGD unit sizes, design pressures,reinforcements types, glass types,sill riser(detail sheet 4)and anchor requirements. 2. Rigid White PVC,Tan(Non-white)Rigid PVC and Brown coated(Painted or laminated)white Rigid PVC to be labeled per referenced NOA's requirements. 3. Egress operable doors must comply with min clear width or height per FBC requirement,as applicable. 4. Pocket walls under separate approval,to be reviewed by Building official. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and series and following statement: "Miami-Dade County Product Control Approved",noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA#15-0409.04 and consists of this page 1,and evidence pages E-1 &E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Jorge M.Plasencia,P.E. NOA No.15-1210.02 QMIAMMI.DADS COUNTY Expiration Date: April 21,2021 Approval Date: March 3,2016 ti�y Page 1 PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 11-0107.09) 2. Drawing No. SGD-5470,titled"Vinyl Sliding Glass Door NOA", sheets 1 through 19 of 19, prepared by manufacturer, dated 10/05/15, signed and sealed by Anthony L. Miller,P.E. B. TESTS 1. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 3) Water Resistance Test,per FBC,TAS 202-94. 4)Forced Entry Test,per FBC,TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc., Test Report No.FTL 6637(samples A-1 thru A-5),dated 11/19/10, signed and sealed by Jorge A. Causo, P.E. (Submitted under NOA No. 11-0107.09) 2. Additional test report No.FTL 6638 (samples A-1 thru A-22)per TAS 201/203-94, issued by Fenestration Testing Lab,Inc., dated 11/19/10, signed and sealed by Jorge A. Causo,P. E. (Submitted under NOA No. 11-0107.04) 3. Additional test report No. FTL 8717,issued by Fenestration Testing Lab, Inc., dated 12/07/15, revised on 02/15/16 and 02/24/16,signed and sealed by Idalmis Ortega,P. E. (Submitted under NOA No. 15-1210.01) 4. Additional test report No.FTL 8546 issued by Fenestration Testing Lab, Inc.,dated 11/06/15, revised on 01/04/16 and 02/11/16, signed and sealed by Idalmis Ortega,P.E. (Submitted under NOA No. 15-1210.01) 5. Additional test report No.FTL 8547 issued by Fenestration Testing Lab, Inc., dated 12/04/15, revised on 02/15/16, signed and sealed by Idalmis Ortega,P. E. (Submitted tinder NOA No. 15-1210.01) 6. Additional test report No.FTL 8548 issued by Fenestration Testing Lab, Inc.,dated 12/04/15, revised on 01/04/16 and 02/11/16, signed and sealed by Idalmis Ortega, P. E. (Submitted under NOA No. 15-1210.01) 7. Additional test report No.FTL 8549 issued by Fenestration Testing Lab,Inc., dated 12/04/15, revised on 12/04/15 and 02/11/16,signed and sealed by Idalmis Ortega,P. E. (Submitted under NOA No. 15-1210.01) 8. Additional test report No. FTL 8552 issued by Fenestration Testing Lab, Inc.,dated 12/04/15, revised on 02/15/16, signed and sealed by Idalmis Ortega,P. E. (Submitted under NOA No. 15-1210.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis,complying with FBC-2014,prepared by PGT, dated 12/09/15 and last revised on 02/15/16, signed and sealed by Anthony L.Miller, P.E. Jorge M.Plasencla,P.E. Pr duct Control Unit Supervisor NOA No.15-1210.02 Expiration Date: April 21,2021 Approval Date: March 3,2016 E-1 PGT Industries NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED C. CALCULATIONS (continued) 1. Glazing complies with ASTME-1300-02, -04 & -09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources(RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 15-0528.14 issued to Vision Extrusion Ltd for their"White Rigid PVC",expiring on 09/30/19. 2. Notice of Acceptance No. 15-0528.11 issued to Vision Extrusion Ltd for their"VE 1000 Tan (Non-White) Rigid PVC",expiring on 12/29/16. 3. Notice of Acceptance No. 15-0528.15 issued to Vision Extrusion Ltd for their"Brown Coated (Painted or Laminated)White Rigid PVC", expiring on 09/30/19. 4. Test reports No(s). 10-002-792(A), 10-06-M0527, 535753-09,per ASTME-84,ASTMD1929 and ASTMD-635,issued by EXOVA to Vision Extrusion for cellulosic composite material. {Submitter)under NOA No. 11-0107.04) F. STATEMENTS 1. Statement letters dated 12/09/15 indicating compliance to FBC 2014(5`h Edition) and"No financial interest",prepared by PGT, signed&sealed by Lynn Miller,P.E. 2. Letter of lab compliance,part of the above test reports. G. OTHER 1. Notice of Acceptance No. 15-0409.04,issued to PGT Industries,for their Series"5470"Vinyl Sliding Glass Door(Reinforced)—N.I.", approved on 06/18/15 and expiring on 04/21/16. Jorge M.Plasencia,P.E. Z uct Control Unit Supervisor NOA No.15-1210.02 Expiration Date: April 21,2021 Approval Date: March 3,2016 E-2 SERIES 5470, NON-IMPACT RESISTANT SLIDING GLASS DOOR TABLE A: INCLUDING POCKETS &900/1350 CORNERS Group Anchor Substrate Frame ad Edge In,!m6 dment "MIN. THREADS BEYOND THE METAL PT Southern Pine se emb e' SUBSTRATE.METAL GENERAL NOTES: (SG=0.65 P•wo r &16' 1-31 1)GLAZING TYPE OPTIONS:SEE GLAZING DETAILS ON SHEET 10. 812,steel SMS SUBSTRATE TO'MEET MIN. (06)or 410 B.S. Aluminum.thickness) FNeP-hooJemb 318' 1/e• STRENGTH AND THICKNESS 2)DESIGN PRESSURES: SMS, 0.125'min.INcknses P•hook 3/8' 118' A.NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS PER ASTM E1300. (min.11 Steel.A36' HeedISIIVJemb 3/8' 0.080' REQUIREMENTS PER 0.080'min.thlokneeeNIHoadIS1111,1amb -hook 31P 0.060• CURRENT FLORIDA BUILDING B.POSITIVE DESIGN LOADS BASED S I TESTED PRESSURE,WATER TEST PRESSURE AND GLASS PER ASTM El300. A thnads/n) Steel Stud,A653 Or.33' 0.071. 14 0a. CODE AND TO BE REVIEWED 3)ANCHORAGE:THE 33-1/3°/s STRESS INCREASE HA8 NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.MATERIALS, 0.071'min.tNoknese -hook 0.07' 4 Oa. BY 1'HE AUTHORITY HAVING INCLUDING BUT NOT LIMITED TO STEEL SCREWS,THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS 1/4'Eloo P.. outhern Pineamb 1• I-No, JURISDICTION. SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE(FBC). Ultecon S0"0.65 -hook 1• 13/9• 4)SHUTTERS ARE REQUIRED PER FBC REQUIREMENTS,AS APPLICABLE. 1/4•Elco 410 P.T.Southern Plas .1VJemb 1' .3/8' FOR STEEL STUDS6)INSTALLATION SCREWS&FRAME SPLICES TO BE SEALED WITH NARROW JOINT SEALANT. S.S.CrateFlez 50.0.65 -hook 1' 1.318' MIN,FUW6 KSI& 6)REFERENCES(NOA'S):ELCO ULTRACON,CRETEFLEX&AGGREGATOR ANCHOR NOAS,VISION EXTRUSION,LTD, B 812.sisal wood P.T.Southern Pine SAUJamb g/19' 1-318' MIN.FY=33 KSI. WHITE RIGID PVC NOA,VE 1000 TAN 202 AND LIGHTER SHADES(NON-WHITE)RIGID PVC NOA AND BROWN COATED screw G6 So-0.65 -took 11116' 1319• (PAINTED OR LAMINATED)WHITE RIGID PVC NOA Concrete P hook I. 1-9ro1/4' •UNOROUTED CMU"VALUES REFERENCES(TEST REPORTS):FTL-8337,6338.8646-8649.8652&8717;EXOVA-10-002-792(A)&10.006-10231; Ull ltraEloo .In.2.65 kel Flead/SIIVJamb 1.3118' 13/8' CAMBRIDGE 535763-09; oon Ungrouted CMU, Jamb 1• 1-1/4• MAY BE USED FOR GROUTED LAS Tke 7)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FBC, INCLUDING THE GBO P-faok 1• t/4• CMU APPLICATIONS. UrigroNs U. Jamb 1.314' 1- HIGH VELOCITY HURRICANE ZONE(HVHZ).THE RIGID WHITE,BROWN&TAN PVC MANUFACTURED BY VISION 1/4'Elco 410 ASTM C-90 P•hook 1• 4' 1.1/4' EXTRUSIONS,LTD.HAS BEEN TESTED TO COMPLY WITH THE FBC FOR PLASTICS,(COMPONENT REQUIREMENTS). S.S.CreteFlax Concrete HsadlSIIVJemb i-3119r 144• IMPACT RATING 8)DOOR SIZES MUST BE VERIFIED FOR COMPLIANCE WITH EGRESS REQUIREMENTS PER THE FBC,AS APPLICABLE. min.3.36 kel P-hook 1' 4' NOT RATED FOR MISSILE 9)DRAWINGS DEPICT EXTERIOR-GLAZING,HOWEVER INTERIOR-GLAZING MAY BE SUBSTITUTED. Conorele Heed/S111/Jamb 1-1/21 1316• IMPACT RESISTANCE 10)THE 6470 SERIES SLIDING GLASS DOOR MAY ALSO BE KNOWN AS THE 470 SERIES. min.2.22 kel P-hook 1-11 1319' 114'Elco 186 (min. CMU, Jamb 2• 11414' DESIGN PRESSURE RATING S.S.AOare-Gator ASTM G90 P-hook 2• 1-1/4' ANCHOR NOTES: P.T.Southern Pine Hsad/SEVJanb 1.3/9• SEE TABLES 1,2&B1,B2 1)FOR CONCRETE/CMU SUBSTRATE APPLICATIONS IN MIAMI-DADE COUNTY,USE ONLY MIAMI-DADE COUNTY SG-0.55 P-hook 1' 1.3116• ON SHEETS 7&8 APPROVED ELCO ANCHORS.SEE TABLE A ON THIS SHEET FOR EMBEDMENT,EDGE DISTANCE AND SUBSTRATE Concrete ea SIII/Jsmb 2-112• 1.3/61 REQUIREMENTS. 1/4•Elco min.2.85ks1) P-hook 2.1/7 1.3/8• 2)FOR OTHER SUBSTRATE APPLICATIONS SEE TABLE A ON THIS SHEET. Ullracon Unrrouled CMU, Jamb 2.1ir 1-1/4' 3)WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2'THICK.PROPERLY SECURED,1X WOOD BUCKS ARE OPTIONAL p ASTM G90 P-hook 2.1/T 11-114• IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU.WOOD BUCKS DEPICTED AS 2X ARE 1-1/2"THICK OR Concrete sadlSl Jamb 2412' 13141 PRODUCT RENEWED 1!4'Elco 410 min.3.35 kei P-hook 2-1/2• +s comp)Ing with the Florida GREATER.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. S S.crco,110 U routed CMU, Jam 2112 1.1Iq eullding odo BUCK DESIGN AND INSTAL-LATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD&TO BE ng NOA-No. 15-1210.02 REVIEWED BY THE BUILDING OFFICIAL. ASTM 090 P-hook I 2-1/2' 1-1/4' E+ptr+tion g+11004/2112021 4)METAL SUBSTRATE TO MEET MIN.STRENGTH AND THICKNESS REQUIREMENTS PER THE FBC AND TO BE REVIEWED BY BY THE AUTHORITY HAVING JURISDICTION. By NOTES.............1 Ml+nai ado ProdMd control 6)IF SILL IS TIGHT TO SUBSTRATE,GROUT OR OTHER MATERIAL IS NOT REQUIRED.IF USED,NON-SHRINK, EXAMPLE CONFIGS..........2 NON-METALLIC GROUT,MAX.1/4"THICK&3400 PSI MIN.,(DONE BY OTHERS)MUST FULLY SUPPORT THE ENTIRE INSTALL DETAILS..............3.6 LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE,AND TRANSFER SHEAR LOAD TO SUBSTRATE.IF DP/ANCHOR TABLES 7-8 SUBSTRATE IS WOOD,308 FELT PAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE,OR AS EXAMPLE............................9 APPROVED BY THE AUTHORITY HAVING JURISDICTION. GLAZING DETAILS............10 STANDARDS USED: ANCHOR LOCATIONS..-....11-16 2014 FLORIDA BUILDING CODE(FBC),6TH EDITION PANEL TYPES...................17 INSTRUCTIONS: ASTM E1300-09 EXTRUSIONS.....................18 1) KNOWING THE REQUIRED DESIGN PRESSURE OF THE OPENING,THE ANCHOR REQUIREMENTS FOR ANSUAF&PA NDS-2012 FOR WOOD CONSTRUCTION ACCESSORIES..................19 11I II/ THE SLIDING GLASS DOORS MAY BE DETERMINED FROM DESIGN PRESSURE TABLES 1 OR 2, ALUMINUM DESIGN MANUAL,ADM-2010 SCREEN DETAILS.............20 ��71�1�YNN Ml� DEPENDING ON THE REINFORCEMENT LEVEL DESIRED. i 2)LOCATE THE SLIDING GLASS DOOR SIZE ON THE TABLE,USING THE FRAME HEIGHT AND THE AISIS700-07/S2.2010 PARTS LIST........................21 �� tO�• E''<Fp '�:'J S '••.icy; NOMINAL PANEL WIDTH IF YOUR EXACT SIZE IS NOT LISTED,ROUND UP TO THE NEXT GREATER LISTED 8105 WIDTH AND/OR HEIGHT. VINYL SLIDING GLASS DOOR NOA 10/06115 .;4<r po.5 _ 3)CHOOSE WHICH ANCHOR GROUP(A-D)IS MOST APPLICABLE.ANCHORS ARE DEFINED IN TABLE A, W THIS SHEET,ALONG WITH THE CORRESPONDING SUBSTRATE,MINIMUM EMBEDMENT AND MINIMUM GENERAL NOTES J ROSOWSKI '.I/Q �f 6 t EDGE DISTANCE. < - TI 4)FROM THE DESIGN PRESSURE TABLES(TABLES 1 OR 2),VERIFY THAT THE OPENING'S REQUIRED l.p ee tt . CERT.OF RUTH.r2g296 R _ _-_ 4� 'SOX.'•,, F..... DESIGN PRESSURE IS MET OR EXCEEDED.USE THE ANCHOR QUANTITIES SHOWN. 1070 TECHNOLOGY DRIVE n � c`SSI 5)INSTALL AS PER THE GUIDELINES OF THIS SHEET-SET. �r,/r r UM 1 r t 1111 8)ADDITIONALLY,SEE THE EXAMPLE ON SHEET 9. N.VENICE,FL 34275 - A.LYNII MILLER,P.E. (941)-480-1600 SGD-6470 NTS 1OF21 f MD-5470.0 k4 P.tt.reeTOp MAX.UNIT WIDTH MAX.UNIT WIDTH MAX.UNIT WIDTH ► NOM.PANEL WIDTH _ - NOM.PANEL WIDTH NOM.PANEL WIDTH _ � NOM.PANEL WIDTH MAX.UNIT WIDTH PER TABLES 1&2 PER TABLES 1&2 PER TABLES PER TABLES 1&2 MAX.UNIT®-, /{ I MAX..UNl IT / / I MAX.UNIT ® E/${l I t I MAX.UNLIT ll ( HEIGHT Ik" HEIGHT / / I HEIGHT � Cil 1 1 PER TABLES 1&2 1 PER TABLES 1&2 / / roc�r I LIZ TABESR1&2 / AIPER TABLES 1&2 / / wcrtar l 1-PANEL 2-PANEL 3-PANEL CONFIGURATIONS 4-PANEL CONFIGURATIONS CONFIGURATIONS CONFIGURATIONS MAX.UNIT WIDTH - MAX.UNIT WIDTH MAX.UNIT WIDTH NOM.PANEL WIDTH NOM.PANEL WIDTH NOM.PANEL WIDTH 7T PER TABLES 1&2 PER TABLES 1&2 PER TABLES 1&2 T— 77-}���-•—� I I MAX.UNIT s MAX.UNIT ��� I MAX.UNIT l / `m HEIGHT I I / I HPIERT / a,Tw I" I]EIGHT 1&2 rwn. PER TABLES 1&2 / I PER TABLES I&2 / / / / / / TABLES g 5-PANEL CONFIGURATIONS 6-PANEL CONFIGURATIONS VCORNER,TYP. Qw.1m coy V "M`I vm.uaroe coRwR slue MAX.UNIT WIDTH — — MAX.UNIT WIDTH --____ _ PRODUCT RENEWED v ftl T wltli th.Florld. NOM.PANEL WIDTH NOM.PANEL WIDTH Building Coda PER TABLES 1&2 T NoA.-No. 15-1210.02 PER TABLES 1&2 Expiration Dah 04/21/2021 ` g 1 1---- --- __ M HEIGHT C�7 9 I / I MAX.UNIT f �I+ ( � l 1 r I Mlaml-0 Product Con I HEIGHT 1J I ' I" PER TABLES 1&2 / / / / / / 1g PER TABLES 1&2 / / / / / / / I � J 7-PANEL CONFIGURATIONS _ 8-PANEL CONFIGURATIONS CONFIGURATIONS NOTES: ")C=OPERABLE PANEL 1)ALL CONFIGURATIONS SHOWN ARE ALSO AVAILABLE AS POCKET CONFIGURATIONS AT EITHER OR BOTH JAMB "0",INOPERABLE PANEL DLO WIDTH=NOM.PANEL WIDTH-8-9/18" `` I I11 I III' , �1 ��� ( LOCATIONS.EXAMPLE:4-PANEL XXXX IN POCKET(p)CONFIGURATION CAN BE pXXXXp,pXXXX OR XXXXp.OXXX IN "P"=POCKET POCKET DLO HEIGHT-DOOR HEIGHT-11-1/78"PANEL HEIGHT=DOOR HEIGHT-2-1/2' 'vcr�sE '•LYNN 4f,.e POCKET CONFIGURATION CAN BE OXXXp. .; 'i:' '•.is 2)90"&135•CORNER CONFIGURATIONS ARE A COMBINATION OF ANY 2 STRAIGHT CONFIGURATIONS. VINYL SLIDING GLASS DOOR NOA 10/05/15 =do Ilo�.G87�05..� EXAMPLE CONFIGURATIONS JROSOWSKI �b w 3)POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND IS TO BE DESIGNED BY OTHERS AND ` REVIEWED BY THE AUTHORITY HAVING JURISDICTION. K < =�1'• o X�;v DETAIL LETTER %Oc ••.......... 4)FOR NOM.PANEL WIDTH,SEE TABLES 1&2. CERT.OF RUTH.N40206 = , 1070 TECHNOLOGY DRIVE �� '� `Sf 0NA��j\`\ 6)MAX.ALLOWABLE FRAME SQUARE FOOTAGE=472.858 FT' L—SHEET NUMBER N.VENICE,FL 34275 1(941)-480-1000sMD-5470.0NTS 2 O 21 � MD-5470.0 i4 A.LYNNNIUAKP.E. P.El wes DETAIL Al DETAIL 131 METAL TYP.,SEE ANCHOR THRU Ill= ASTRAGAL DETAIL C1 DETAIL D1 NOTE 4,SHEET 1;MIN.OF 3 .. NAsFACNO EKT. INTERLOCK WTO NETAL THREADS BEYOND THE CONCRETE/CMU PER S ANCHOR REQUIREMENT FRAME WIDTH METAL UBSTRATE 1/4"MAX. REQUIRED IF DOOR 19 TYP.ANCHOR TYPE, .; HEIGHT IS OVER 96' 21 9e EMBEDMENT AND %MAX .c. w r EDGE DISTANCE PER "•: 2: EDGE SUBSTRATE,SEE +'. DISTANCE TABLE A,SHEET 1& •+`'..: n q o e DAYLIGHT NOTE 3,BELOW � OPENINGIN7ERIQH n 2e _ a o WIDTH EMBEDMENT 7--��N(1111X1 - u I r EDGE ��- .j�.. \ d d d d EDGE DISTANCEj.'�.'-.-, 2a DRlxa 01 I 82 ER DISTANCE /...: - .. 94 I I SEE NOTE 6, ]11� - SEE NOTE 8, 2a O Te 27 0 26 Q4"MAX. ---I / 1X OR 2X WOOD THIS SHEET I I SEE NOTE 8, � �THIS SHEET - ° / BUCKSTRIP,SEE a2 THIS SHEET EMBEDMENT ANCHOR / \ / SEE NOTE 9,THIS SHEET Zo NOTE 4,SHEET 1 L_—————- _ #8 X 3/4'SMS REINFORCEMENT SCREW;T PER STILE,LOCATED AT CENTERLINE AND 8", TYP.ANCHOR TYPE, PLATE EVERY // HORIZONTAL SECTION(XXX SHOWN EMBEDMENT AND B'&12"FROM ENDS(FACTORY INSTALLED). EDGE DISTANCE PER ANCHOR � ����` SUBSTRATE,SEE LOCATION 2 DETAIL C2 DETAIL RY DETAIL B2 'TABLE A,SHEET i d DETAIL A2 INTERLOCK INTO MAso�v ��� ASTRAGAL 2X WOOD BUCKSTRIP OR NOTE 3,BELOW INTOzx WOOD to REOUIRED IF DOOR EMBEDMENT �� FACING Ni. FRAMING,SEE ANCHOR 9e DAYLIGHT 21 91 HEMaHT IS OVER 96' 1/4„MAx NOTE 3,SHEET 1 OPENING r 22 1 INTERIOR ( PRODUCT RENEWED WIDTH I t•• EDGEI I .comp syIny 1 DISTANCE Bwlth tho Florida oudinp Cod. TYP.ANCHOR TYPE, p SEE NOTE a,THIS SHEET O •' y I I NOA-No. 18-1210.02 EMBEDMENT AND xa 27 M 26 -_ .l I I Expiration Date 04/21/2021 EDGE DISTANCE PER 9a 23 a TYP.ANCHOR TYPE, I I By SUBSTRATE,SEEy�g EMBEDMENT AND Mlaml D ►rodual Control TABLE A,SHEET 1& o° o aI q P ` EDGE DISTANCE NOTE 3,BELOW PER SUBSTRATE, SEE TABLE A,SHEET Irmmimd d DISTDANCE Lam d 1&NOTE 3,BELOW I EMERIOR I I--------J I-�1/4"MAX. PANEL WIDTH — CONCRETE/CMU PER ASTRAGAL MAY BE EMBEDMENT HORIZONTAL SECTION(XO SHOWN) ANCHOR REQUIREMENT INSTALLED IN EITHER FIXED PANEL CLIP& INTERIOR OR NO LYNN Atilt,, NOTES ANCHORS,SEE EXTERIOR DIRECTION. �'ON'1,,......, ,P 1 DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. REINFORCEMENT TYPES/SEE NOTE 8,THIS BHEETI DETAIL SHEET 19 r JGENSf ) ALL PARTS IDENTICAL. 2)REFER TO ANCHOR NOTES,SHEET 1. FOR ALL LOCKSTIlE3 3)SEE SHEET 13 FOR ANCHOR LOCATION&SPACING,FOR ASTRAGALS, , FIXED j(•: NO.58TO5 ANCHOR QUANTITIES,SEE TABLES 1&2. STILES AND xa Om VINYL SLIDING GLASS DOOR NOA 10/05/15 - 0:= 4)CONTINUOUS ANCHOR PLATE,ITEM#8,IS REQUIRED AT ALL HORIZONTAL MILS _ ..LLI.- INSTALLATION,HORIZONTAL XSECT.1S J ROSOWBKI �� `• a FRAME ANCHOR LOCATIONS. Z. o'•, 5)PANEL WIDTH DOES NOT INCLUDE INTERLOCK OR ASTRAGAL ADD-ON. • ` < '•fin'. s lot•'' CO` 8 SEE TABLES 1&2 FOR REINFORCEMENT REQUIREMENTS.ALL FOR 1/ AN •.;,LOµ,••' a` REINFORCEMENTS ARE APPROXIMATELY THE FULL LENGTH OF IMERLONLY j O CERT.OF OL GY D , ',,A �eC�•S�ON�� ONLY 1070 TECHNOLOGY DRIVE �� 77I„IItI,t t THE EXTRUSION.REFER TO TEST REPORTS FOR EXACT DIMENSIONS. STANDARD HD N.VENICE,FL 34275 7)SEE SHEET 20 FOR SCREEN DETAILS. (941)•480-1800 SGD-5470 NTS 3 OF 21I 1$ MD-5470.0 A.LYNN MILER,P.E. P.E.a 68705 DETAIL E1 TYP.ANCHOR TYPE,EMBEDMENT DETAIL E2 DETAIL E3 DETAIL E4 Wf0 MASONRY I AND EDGE DISTANCE PER Iwo woo D INTO MASONRY INTO METAL DADE APPROVED MULLION,FBC tx eucxsraw SUBSTRATE,SEE TABLE A,SHEET COMPLIANT ALUMINUM/STEEL 1&NOTE 3,THIS SHEET 2X WOOD BUCKSTRIP OR TYP.ANCHOR TYPE.EMBEDMENT FRAMING OR STEEL STUD.MAY FRAMING,SEE ANCHOR CONCRETEICMU EDGE ANp EDGE DISTANCE PER CONCRETE/CMU PER BE VERTICAL OR HORIZONTAL. PER ANCHOR DISTANCE NOTE 3,SHEET 1 SUBSTRATE,SEE TABLE A,SHEET \ANICHOR REQUIREMENT SEE SUBSTRATE PROPERTIES, REQUIREMENT + EDGE 1&NOTE 3,THIS SHEET EDGE TABLE A,SHEET 1 DISTANCE DISTANCE EMBED- EDGE DISTANCE r MENT ( EMBEDMENT .•`� EMBEDMENT EMBEDMENT - I1/4"MAX. - 114"MAX. e 1 X OR 2X WOOD 1/4"MAX. ° IHI 1/4"MAX. ffTYP. ° 114"MAX, t ° / BUCKSTRIP,SEE ° 6o ANCHOR NOTE 3, Q° TYP.ANCHOR TYPE,EMBEDMENT AND OR TYPE,EMBEDMENT AND T SHEET1 —EDGE DISTANCEPERSUBSTRATE,SEE TANCE PER SUBSTRATE,SEE / TABLE A.SHEET 1&NOTE 3,THIS SHEET TABLE A.SHEET 1&NOTE 3,THIS SHEET 33 NOTES / Loa<srlLEs, 1)DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. _- ASTRAGALS, 2)REFER TO ANCHOR NOTES,SHEET 1. FIXED STILES 3)SEE SHEETS 11&12 FOR ANCHOR LOCATION&SPACING, AND #8 X 3/4"SMS REINFORCEMENT FOR ANCHOR QUANTITIES,SEE TABLES 1&2. DLO WIDTH-NOM.PANEL WIDTH-8.0/16" NoalzoNru SCREW;3 PER RAIL,LOCATED AT 4 CONTINUOUS ANCHOR PLATE,ITEM#8,IS REQUIRED AT DLO HEIGHT-DOOR HEIGHT-I IAil 6" ANCHOR PLATE A7 RAILS CENTERLINE AND 0"FROM ENDS ALL FRAME ANCHOR LOCATIONS. PANEL HEIGHT-DOOR HEIGHT-2-1/2" EVERY ANCHOR (FACTORY INSTALLED) 5)SEE SHEET 20 FOR SCREEN DETAILS. LOCATION DAYLIGHT 6)SEE TABLES 1&2 FOR REINFORCEMENT REQUIREMENTS. OPENING FRAME SEE � PANEL ALL REINFORCEMENTS ARE APPROXIMATELY THE FULL HEIGHT HEIGHT NOTE o, HEIGHT SILL RISER LENGTH OF THE EXTRUSION.REFER TO TEST REPORTS FOR EXACT DIMENSIONS. PRODUCT RENEWED THIS SHEET VARIES WITH as eom 1yIny with the Florida REQUIRED BUDA-Mo Codi EXTERIOR POSITIVE Now Wo. 13-1210.02 O 4 DESIGN 390_� Imo— expiration o •04 21/2021 8 PRESSURE, r e ><xTeaxlfl et oa as SEE SHEETS' •300—rl ham— T Diem t• a_roduee eontm a 7&8. 990 r- I sa R 2e 900 � 2.847 2.370 1/4"MAX. W26HOWN 1.793 3.464 j 4.041 GROUT AS - ° #43.45 ALSO APPLY.829 � 2.887 NEEDED,SEE t° Mo -� 1.917 ANCHOR NOTE _11 6,SHEET 1 ° s 12 2-1/2"=TOTAL 080 •080 060 .080 _ © 1/4'MAX. O °� 8 SILL HEIGHT SILL RISER SILL RISER SILL RISER SILL RISER Lt L 111 °2(2-1/2"TOTAL O(3Al2"TOTAL O(4-1/10`TOTAL �°(4-618"TOTAL ��� Y%YNN SILL HEIGHT) SILL HEIGHT) SILL HEIGHT) SILL HEIGHT) ��1� ''cswa'U<<F EMBED- ` , EMBEDMENT EDGE - :' �L F •.P MENT 4 (STANCE L4 VINYL SLIDING GLASS DOOR NOA 1 10/06/16 >c I4o.,58705 !r EDGE + TYP.ANCHOR TYPE, TYP.ANCHOR TYPE, J INSTALLATION,VERTICAL X-SECT. J ROSOWSKI . 0 DISTANCE EMBEDMENT AND 2X WOOD BUCKSTRIP OR EMBEDMENTAND ,-7 EDGE DISTANCE FRAMING,SEE ANCHOR EDGE DISTANCE o X s iV X1, CONCRETEICMU PER SUBSTRATE, NOTE 3,SHEET 1 PER SUBSTRATE, CERT.of AUTN.#z>tz°S _ �� ; '•FConIDn,. ��\: PER ANCHOR IDETAIL F1 SEE TABLE A, DETAIL F2 SEE TABLE A, 1070 TECHNOLOGY DRIVE �� �'l;�,`Sf0NIA); REQUIREMENT SHEET 1&NOTE 3, ETA(oD SHEET 1&NOTE 3, N.VENICE,FL 34275 — 1/'1 it MILLER,IP.E. WTO MA80NRY THIS SHEET gg THIS SHEET (941)-480-1600 SOD-5470 NTS 4 OF 21 d>� MD-5470.0 d P E F°egos I 7 NTI ERIOR u, TI Q Z INTERIOR 4 ZB Y6 M 76 OR 26 37 96 MAX 16.6'O.C. INTERIOR 1 1� Y6 SEE 19 --- se MAX 3 MIERIOR DETAIL H2 6.O.C. o P 19 BEE SHEET 19 --- XTE 90' a N ❑ I GI OUTSIDE CORNER 3s 00' Q LILI 36 INTERIOR 26 2E 04 MAX 16.6.O.C. Tim EXIITE�R609 37 ❑� 136• V tt 90' � q DETAIL G1 DETAIL H1 13s• MAX18.6.O.0 94 �[] � O �. INSIDE CORNER 8181DE CORNER 40 EXTERIOR INTERIOR61 t - 1E 3.WO.Y 10 M so EXTERIOR E fVl O O eG PRODUCT RENEWED n plyyOI LlnIth the Florida Bulldiny Gw NOA-No. 15-1210.02 135 Q Expiration Do1/2021 RUMOR ey M..-Do r v t Control 7 NOTES 1)DETAILS APPLY TO 2.3 AND 4 TRACK CONFIGURATIONS. u 25 1 ,t T 2)SEE SHEETS 14 Q 16 FOR ANCHOR LOCATION&SPACING,FOR ANCHOR u u QUANTITIES,SEE TABLES 1$2. 33 3s 3)CORNER ASTRAGAL MAY BE EITHER TO THE INTERIOR OR EXTERIOR, { 4 VYNN 4V, 36 DEPENDING ON CONFIGURATION. DETAIL G2 MAX 15.6.O.C.96 - 136• BSE SAX HEET- 79 od EXTERIOR #VINYL SLIDING GLASS DOOR NOA 10/0688 * 14,.50705 OUTSIDE CORNER p _ = CORNER ASTRAGAL HORIZ.XSECT. #1 J ROSOWSKI R ■t ''a'O '•.FLORTOP••'• �� CERT.OF RUTH.8792 N 1070 TECHNOLOGY DRIVE ,S%Nffi- N.VENICE,FL 34276 (941)•480-1800 IISGD-6470111 NTS 111 6 OF 21 d# MD-6470.0 Jill P. A.LYNEd Bp06N PZ M6AER DETAIL 11 DETAIL 12 OPTIONAL NOW IWO MASONRY wro MASONRY STRUCTURAL ANCHORS FOR EDGE CONCRETE/CMU INTERIOR POCKET INTERIOR 9t 21 >!2 TYP.ANCHOR TYPE,EMBEDMENT PER ANCHOR DISTANCE JAMB 33 21 27 AND EDGE DISTANCE PER REQUIREMENT. 6EE FIG 1, SUBSTRATE,SEE TABLE A, " INTERIOR POCKETS MUST THIS SHEET 30 SHEET 1&NOTE 3,BELOW '`', M FIGURE 1 INTERLOCKSAT POCKETS: INCLUDE A NONSTRUCTURAL, FOR DOOR HEIGHTS 96"AND LESS: FRAME JAMB TO REDUCE THE i 1° OPT. POSSIBILITY OF WATER — INFILTRATION. '•:: 1/4"MAX. 4118 d v Pr. EMBEDMENT �' ' , •: ANCHOR POCKET BY OTHERS,SEE tr r. NOTE 6 BELOW. EXTER10 ' MENT-:*''•:"' e+i4H o FOR DOOR HEIGHTS OVER 96" OPT. n 1/4"MAX. q j ANCHOR v to e7 21.9" SEE FIG 1, MAX.O.C. TYP.ANCHOR TYPE,EMBEDMENT CONCRETE/CMU THIS SHEET 31 30 AND EDGE DISTANCE PER � EDGE PER ANCHOR 28 21 SUBSTRATE,SEE TABLE A,SHEET 1 DISTANCE REQUIREMENT &NOTE 3,BELOW INTERIOR POCKET EXTERIOR POCKET 22 - o, --- 21 TYP.ANCHOR TYPE,EMBEDMENT METAL TYP.,SEE ANCHOR NOTE AND EDGE DISTANCE PER 4,SHEET 1;ANCHOR LENGTH TO SUBSTRATE,SEE TABLE A,SHEET 1 E OT3,BE BE A MIN.OF 3 THREADS BEYOND &N2X WOOD BUCKSTRIP OR PRODUCT RENEWED THE METAL SUBSTRATE EDGE FRAMING,SEE ANCHOR ae com I Ing with the Florida DISTANCE ■ulldinp&ode EDGE NOTE 3,SHEET 1 Now-No. 15-1210.02 DETAIL 13 DISTANCEn� -OPT.ANCHOR OPT.ANCHOR Explratlon Date04/21/2021 INTOMETAL EMBEDMENT By r 107 oPT 1 �� 17 OPT. MIamI- i Product antro EMBEDMENT J1/'4" DETAIL 14 1/4"MAX. MAX JJ q I—vvOOO EXIEnRIOH V 10 SEE FIG I• SEE FIG 1, d THIS SHEET�1 THIS SHEET 30 26 27 €iS1ERlo 22 :t N 2e `���1,1%11.YNNI EXTERIOR POCKET Af//c rrrr, EXTERIOR POCKET .. F NOTES DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. Ll ALUMINUM SLIDING GLASS DOOR NOA 10I06H6 ft}' 110.,p705 2)REFER TO ANCHOR NOTES,SHEET 1. 3)SEE SHEET 13 FOR ANCHOR LOCATION&SPACING,FOR ANCHOR QUANTITIES,SEE TABLES 1&2. U P-HOOK EXAMPLES,HORIZ.XSECT. J ROSOWSKI _ _1 ttI 4)SEE TABLES 1&2 FOR REINFORCEMENT REQUIREMENTS, e < + %-1', /K'�b 5)INTERIOR OR EXTERIOR POCKETS APPLICABLE FOR ALL INSTALLATION METHODS. CERT.OF RUTH.02929 �-p 8 .0 '• FLORIOt.' 6)POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND IS TO BE DESIGNED BY OTHERS LOGY DRIVE AND REVIEWED BY THE AUTHORITY HAVING JURISDICTION. 1070 TECHNOLOGY N.VENICE, O 34275I11I i 1 (941)-480-1800 SGD-5470 NTS 6OF21 4 MD-6470.0 �# A.LYNN MILLER,P.E. P.E.O E8711S i TABLE 1: -- -- - — — — — -- — — - --- Design Pressure(DP)and Anchor Quantities Required, (for all approved configuratlons on Sheet 2) Use this table for: Door Unit Height ANCHORAGE TYPE PER SUBSTRATE REQUIRED TO ACHIEVE THE DESIGN PRESSURE,USING THE ANCHOR QUANTIES LISTED BELOW.SEE TABLE A, Astragal Reinforcement#29 80' 84" 96" SHEET 1 FOR COMPLETE ANCHOR LIMITATIONS. Lockslils Reinforcement#25 or#26 68-15/16'DLO Height 72-16/16"DLO Height 84-15/18'DLO Height THE MAXIMUM DP AT THESE ANCHOR QUANTITIES.ADDITIONALLY,THE Sid.Interlock Reinforcement#27 Anchor Group Anchor Group Anchor Group MAXIMUM POSITIVE DP DUE TO THE SILL HEIGHT MUST ALSO BE A 1 B 1 C I D A 1 B 1 C ID A I B IC D / CONSIDERED,SEE TABLE Bt,THIS SHEET. Design Pressure +127.11-127.1 psf +120/-120 psf +102.9/•102.9 psi #OF ANCHORS THROUGH THE HEAD&SILL.(EX:FOR C3+1,3 ANCHORS 19-1l8• Head/Sill C50 C3+1 C3+1 C3+1 C5+1 C3+1 C3+1 C3+1 C5+1 C3+1 C3+1 C3+1 CLUSTERED AT PANEL MEETING POINT AND 1 ANCHOR REQUIRED AT 24" DLO Jamb 6 5 6 6 5 5 8 6 5 6 6 5 _ MIDSPAN OF PANEL). Width P-hook 7 7 7 7 7 7 7 7 8 8 8 8 —TOTAL#OF ANCHORS THROUGH THE JAMB. Design Pressure +106.3/-106.3psf +100,2/-100.2 psf +05.3/-85.3p3f \_THE#OF ANCHORS REQUIRED THROUGH THE P-HOOK, 25-1/8' Head sill C6+1 C3+1 C3+1 C3+1C5+1 C3+1 C3+1 C3+1 C5+1 C3+1 C3+1 C3+1 PERPENDICULAR TO THE GLASS. 30" DLO Width Jamb 5 6 8 5 5 6 8 5 6 6 6 6 P-hook 7 7 7 7 7 7 7 B 1 0 1 0 1 e 3 Design Pressure +92.9/-92.9psf +87.3/-97.3psf +73.0/-73.8psf HeaNSlll C5+1 C3+1 C30 C3+1 C5+1 C3+1 C3+1 C3+1 C5+1 C3+1 C3+1 C3+1 o. 38` DLO Jamb 5 5 6 5 5 5 6 5 5 5 6 6 Width P-hook 7 7 7 7 7 1 7 1 7 7 8 8 8 8 DLO Design Pressure +79.4/-78.4 psf +70.4/-78.4 psf +65.8/-85.8 psf 3HeadiSlll C5+2 C3+1 C3+1 C3+1 C5+2 C3+1 C3+1 C3+1 C5+1 C3+1 C3+1 C3+1 42' DLO 5 5 6 5 TABLE B1: Jamb 5 6 5 5 5 5 8 Width Water-Limited FIG 1; P-hook 7 7 7 7 7 7 7 7 8 8 8 8 (+)Design Pressure OH LENGTH Design Pressure +60/-60ps1 +60/-60Par +60/-60Psf SIII Nom.SIII Max.(+)DP 43.1/0" Head/SillC3+2 C3+1 C3+1 03+1 C3+2 C3+1 C3+1 C3+1 C5+2 C3+1 C3+1 C3+1 40" OLD - Riser Height Allowed DOORASSEMBLIES Width Jamb 5 5 5 5 6 5 5 5 6 5 e 5 None 1-11/18" SeeNote2 INSTALLED WHERE THE P-hook 7 7 7 7 7 7 - 7 7 B 1 8 1 0 B w OVERHANG(OH)LENGTH IS PRODUCT RENEWED 42 2-1/2" +30.7 psi = EQUAL TO OR GREATER THAN ea comp)y ing with the Florlda = amidine Code 43 31/2 +80.0 psf 0 THE OVERHANG HEIGHT IS NOA-wn, 15-1210.02 USED IN EXAMPLE ON SHEET 0 44 4.1/16" +80.0 pef EXEMPTED FROM WATER INplretlon Dete04/21/2021 45 4-518" +100.0 psf j INFILTRATION RESISTANCE. ey DLO WIDTH=NOM.PANEL Miami-D da Product Control WIDTH DLO HEIGHT D ORHEIGHT1/18' 8" `14N4" PANEL HEIGHT=DOOR HEIGHT-2-1/2" / TABLE NOTES_ Q; �- L!VINYL SLIDING GLASS DOOR NOA10/05/16 ' No.58705 - 1)IF WATER INFILTRATION RESISTANCE IS REQUIRED,THE LESSER VALUES OF EITHER TABLE 1 -._—_._ _ __ _ AND TABLE 81 DETERMINES THE WATER LIMITED(+)DP. DP&ANCHOR QUANTITY TABLE & J ROSOWSKI I - 2)IF WATER INFILTRATION RESISTANCE IS NOT REQUIRED OR OVERHANG IS PER FIG 1,A SILL ±'U' RISER IS NOT REQUIRED.IF SO,+DP'S SHOWN IN TABLE 1 MAY BE USED. _e e ,�U'. sT E 3)SEE SILL RISER TYPES ON SHEET 4. _ CERT.of AUTH.#29296 �� c FlOitivP' C9�` a - 4)SHEET APPLIES TO 2,3 AND 4 TRACK CONFIGURATIONS. 1070 TECHNOLOGY DRIVE o S, ' 5)REFER TO ANCHOR NOTES,SHEET 1. �� S G N.VENICE,FL34275 - - — rliiul�' 0)SEE SHEETS 11.18 FOR ANCHOR LOCATION&SPACING A.LYNN MILLER P.E. N.VE ICE, L SGD-5470 NTS 7OF 21 11 MD-5470.0 jO1. PEF6e705 TABLE 2. Design Pressure(DP)and Anchor Quantities Required, (for all approved conftgurattons on Sheet 2) ANCHORAGE TYPE PER SUBSTRATE REQUIRED TO ACHIEVE THE DESIGN Use this table for: Door Unit Height PRESSURE,USING THE ANCHOR QUANTIES LISTED BELOW,SEE TABLE A, Astragal Reinforcement#29 a0" 84' 96" 108" 120" SHEET 1 FOR COMPLETE ANCHOR LIMITATIONS. Loekstlle Reinforcement#26 68-15/18"DLO Height 72-16118"DLO Height 84-16/16"DLO Height 98-16/16"DLO Height 108-15/16"DLO HelghlTHE MAXIMUM DP AT THESE ANCHOR QUANTITIES.ADDITIONALLY,THE HD Interlock Reinforcement 028 Anchor Group Anchor Group Anobor Group Anchor Group Anchor Group MAXIMUM POSITIVE DP DUE TO THE SILL HEIGHT MUST ALSO BE A 8 C D A B G D A B C D A B C D A B C D CONSIDERED,SEE TABLE 62,THIS SHEET. Design Pressure +169.4/-169.4 psf +160/-160 psf +137.1/-137.1 psf +120/-130 pal +106.7/-116.8 psi #OF ANCHORS THROUGH THE HEAD&SILL.(EX:FOR C3+1,3 ANCHORS 19.1/8' CLUSTERED AT PANEL MEETING POINT AND 1 ANCHOR REQUIRED AT Head/Sill C5+1 C6t1 C5+1 C3+1 CSN C5t1 C6+1 C3+1 C5+1 C5+1 C5+1 C3+1 C5t1 C5+1 C5+1 C3+1 C5N C5+1 C5+1 C3+ 24" DLO Jamb 5 5 7 6 5 5 7 5 5 5 7 5 6 8 a B 6 6 8 6 MIDSPAN OF PANEL). Width -- TOTAL#OF ANCHORS THROUGH THE JAMB. P-hook 7 7 7 7 7 1 7 7 1 7 8 8 a 8 9 9 9 B 1010 10 10 THE#OF ANCHORS REQUIRED THROUGH THE P-HOOK, Design Pressure +141.8/-141.8p3f +133.6/-133.6psf +113.0/-113.8psf +99.1/-107.4p3f +87.8/-95.1 psf PERPENDICULAR TO THE GLASS. 25 1/6" Head/Sill C5+2 C5+1 C6+1 C3+1 C5+1 C5+1 C5+1 C3+1 C5+1 C5+1 C5+1 C3H C5+1 C5+1 C5+1 C3+1 C6+1 C5v1 C5+1 C3+1 30' DLO Jamb 5 6 7 6 5 6 7 5 6 6 7 5 6 6 8 6 6 6 8 a Width P-hook 7 7 7 7 7 7 7 7 a 8 6 8 9 9 9 9 10 10 10 10 Design Pressure +123.9/-123.9psf +116.4/-116.4psf +98.5/-98.5psf +85-3/-92.4ps/ +75.3/-8f.8ps/ 31-1/9" Head/Slll C5+2 C5+1 C5+2 03+1 C5+2 C5+1 C5+2 C3+1 C5+2 C5+1 C5+1 C3+1 m+1 C6+1 C5+1 C3+1 C5+1 C5+1 C5+1 C3+1 FIG 1: 35' DLO Jamb 5 6 7 5 5 5 7 5 5 5 7 6 6 6 8 8 a 6 6 6 OH LENGTH Width P-hook 7 7 7 7 7 7 7 7 a B 8 8 9 9 9 9 10 10 10 10 DOOR ASSEMBLIES Design Pressure +104,5/-104.5psf +104.5/-104.5psi +87.8/-87.6psf +75.7/-82ps1 +66.6/-72psf INSTALLED WHERETHE 5 37-1/a" Head/SIN C6+2 C3+2 C5+2 C3+1 C5+2 C6+2 C5+2 C3+1 05+2 C5+1 C5+2 C3+1 C5+2 C5+1 C5+2 C3+1 C5+1 C6+iC5+1 C3+1 2 OVERHANG(OH)LENGTH IS IL 42' DLO Jamb 6 6 7 6 5 5 7 5 5 5 7 6 a a 8 6 6 6 8 8 EQUAL TO OR GREATER THAN Width = THE OVERHANG HEIGHT IS P-hook 7 7 7 7 7 7 7 7 8 8 0 8 9 9 9 9 10 10 10 10 O 0 Design Pressure +80/-80Ps1 +80/-Bops( +80/-80ps1 +60/-85psf +60/-65ps/ EXEMPTED FROM WATER Z 43-1/8" -- INFILTRATION RESISTANCE. 48' DLO Haed/SIII C5+2 C3+2 C5+2 C3+1 C512 C3+2 C5+2 C3+1 C5+2 C5+2 C5+2 CSN C5+2 C3+1 C5+2 C3+1 C5+2 C5+1 C5+2 C3+1 Width Jamb 6 5 a 6 6 5 6 5 5 6 7 5 6 6 7 6 6 8 a 6 P-hook 7 7 7 7 7 7 7 7 6 8 8 8 g 9 9 9 10 1 10 10 10 TABLE B2: PRODUCT RENEWED Design Pressure +74.1/-74.1 psf +74.1/-74.1 psi +63.8/-03.8 psf Water-Limited se comptylna with the Frond• 49-1/8" BulIdina odd• 64" DLO Head/Slit C5+2 C3+2 C3+2 C3+1 C5+2 C3+2 G5+2 C3+1 C5+2 C3+2 C5+2 C3+1 (+)Design Pressure NOA-No. 13-1210.02 Width Jamb 5 6 6 5 5 5 6 5 5 5 6 5 Sill Nom.Bili Max.(+)DP Expiration Date 04/21/2021 P-hook 7 7 7 7 7 7 7 7 6 8 8 8 Riser Height Allowed Not available in these sizes. ay 60 p Design Pressure +80/-60ps/ +601- sf +60/_60ps! None 1-11/18" See Note 2 Miami- •_Product ontro 55-116" HeadlSill C3+2 C3+2 CC3 3+2 +1 C5+2 C3+2 C3+2 C3+1 C5+2 C3+2 C5+2 C3+1 42 2-1/2" +38.7 f 60' WldI Jamb 5 5 6 5 6 5 5 5 5 6 8 6 43 3.112' +80.0 psf P-hook 7 7 7 7 7 7 7 7 8 8 8 6 44 4-1/16" +80.0 psf 45 1 4-5/8" +100.0 1 DLO WIDTH=NOM.PANEL WIDTH-8-9118" DLO HEIGHT-DOOR HEIGHT-11-1/16" \J��p���LYNN A PANEL HEIGHT=DOOR HEIGHT-2-112" a�•. 1cFlrsr p , TABLE NOTES: v �.; -- I - Ru,58705 1)IF WATER INFILTRATION RESISTANCE IS REQUIRED,THE LESSER VALUES OF EITHER TABLE 2 VINYL SLIDING GLASS DOOR NOA 10/05/15 AND TABLE B2 DETERMINES THE WATER LIMITED(+)DP. f DP&ANCHOR QUANTITY TABLE ra J ROSOWSKI TfO 2)IF WATER INFILTRATION RESISTANCE IS NOT REQUIRED DR OVERHANG IS PER FIG 1,A SILL J -- -- ----. %� •, 1 IJJRISER IS NOT REQUIRED.IF SO,+DP'S SHOWN IN TABLE 2 MAY BE USED. as nN 3)SEE SILL RISER TYPES ON SHEET 4. CERT.OF RUTH.#29296 - _ �a F'•..«Rto•.��\; 4)SHEET APPLIES TO 2,3 AND 4 TRACK CONFIGURATIONS. 1070 TECHNOLOGY DRIVE a+ "01111101" 6) ` 5)REFER TO ANCHOR NOTES,SHEET 1. N.VENICE,FL 34275 - �- 6)SEE SHEETS 11-16 FOR ANCHOR LOCATION&SPACING _ -- I A.LYNN MILLER.P.E. (041)-480-1800 SGD-5470 NTS dr 8 OF 21 f MD-6470.0 ( P.E955705 EXAMPLE: - 3-PANEL,3 TRACK,STRAIGHT CONFIGURATION-PXXX, FRAME JAMB REQUIRED HEgD SPLICE INT CENTERLINE CENTERLINE SEE FIGURE BELOW FOR ADDITIONAL INTERIOR MOUNT POCKET,46'X 84"NOM.PANELS, 0INTERIOR POCKETS OF INTERLOCK OF INTERLOCK ANCHOR INFORMATION. 8' CENTERLINE CENTERLINE CENTERLINE LAMINATED,IG GLAZING,ANCHOR GROUP A IN WOOD SUBSTRATE, MAX. OF PANEL 1 -OF PANEL 2 OF PANEL 3 PROJECT DESIGN PRESSURE REQUIRED:+48.21-58.6 PSF POCKET BY OTHERS,SEE NOTE 8, SHEETS - v2• 25-3/8*MAX. e• _ '+2'ANCHORAGE. 2 ANCHORA[aE, ANCHORAGE, '-• MAX AX. SHEET12 SHEET 12 Sf IEET 12 *C3'CLUSTER. 'C3'CLUSTER.12 EXTERIOR SHEET I2 SHEET I2 END ANCHOFUOE (MIN.1 ANCHOR) SEE POCKET JAMS 15 SPLICE NOTE: INSTALLATION ON HEAD ANCHORAGE DETAILS OPT.ANCHOR EXTERIOR NONSTRUCTURAL ANCHORS MAY SETS PXXX(3-TRACK) TO AID IN BE ADDED INFIELD AS NEEDED TO ALIGNMENT ALIGN THE HEAD OR SILL IF A 4 SPLICE OCCURS WITHIN A POCKET. SILL SPLICE INTERIOR CENTERLINE CENTERLINE __SEE FIGURE BELOW FOR ADDITIONAL OF INTERLOCK OFWTERLOCK ANCHOR INFORMATION. a" CENTERLINE CENTERLINE CENTERLINE �J MAX. OFPANEL I OFPANEL 2 OF PANEL 3 POCKETBY p p o e - EXTERIOR 1-NTERiQR OTHERS.SEE _ -- �� NOTE 6, 0 o a o p SHEET 8 Y2• 25-318'MAX.INK _ g' +2'ANCHONAOE, ANCHORAGE. ANCHORAGE, MAX SHEET II SHEET II SHEETII 'C3'CLUSTER• 'C3'CLUSTER, 12,MAX. 218• SHEET11 SHEET II END ANCHORAGE EXTERIOR FRAME JAMB SEE POCKET JAMB (MIN.i ANCHOR) • REQUIRED® INBTALLATIONON SILL ANCHORAGE DETAILS O.C. INTERIOR POCKETS SHEET 1)KNOWING THE PRODUCTS REQUIREMENTS,SCAN THROUGH TABLES I&2 PXXX(3-TRACK) PRODUCT ggRENEWED FOR A DESIGN PRESSURE THAT MEETS OR EXCEEDS THE REQUIREMENT OF BuildinglCodoW with the Flo rlda +48.2/-58.8 AT A NOM.PANEL SIZE OF 48"X 84'.FROM TABLE 1,SHEET 7,THE END PANEL ANCHOR EXCEPTION: Now-No. 15-1210.02 DESIGN PRESSURE IS+80/-80 WHICH EXCEEDS THE PROJECT DESIGN DISTANCE TO NEXT CLUSTER — Expiration Dob 04/21/2021 PRESSURE REQUIREMENTS. T00E25,VS.O.C.ORLESS By I FOR WOOD INSTALLATION USING ANY I HiIaWslft I q+2 Mb -D ro uo!Con/ro ANCHOR IN GROUP A(SEE TABLE A),TABLE I Jamb 1 SHOWS ANCHOR REQUIREMENTS OF: P h°DI' _ --- A 2)ANCHOR LOCATION DETAILS,CAN BE FOUND ON: 61 MAX. HEAD(CLUSTER ANCHORS):SHEET 12 FOR THE"C3"CLUSTER ANCHORS AT CENTERLINE OF END PANEL e'MAX. THE INTERLOCK/ASTRAGAL. FOR SILL(SHOWN)AND HEAD,ANCHORS AT THE OPT.ANCHOR TO AID IN \ 1 HEAD(INTERMEDIATE ANCHORS):SHEET 12 FOR THE"+2 ANCHORS AT THE MIDPOINT OF END PANELS ARE ONLY REQUIRED IF THE . ALIGNMENT ` MIDSPAN OF EACH PANEL. O.C.DISTANCE TO THE NEXT ANCHOR CLUSTER IS OVER P-HOOK JAMB SILL(CLUSTER ANCHORS):SHEET 11 FOR THE'C3"CLUSTER ANCHORS AT 25.3/8",OTHERWISE ANCHORS ARE NOT REQUIRED AS LI I4ITi ANCHORAGE ANCHORAGE ... (/u7 THE INTERLOCK/ASTRAGAL. PER THE FIGURE ABOVE: �� ON SILL(INTERMEDIATE ANCHORSI:SHEET 11 FOR THE"+2 ANCHORS AT THE l?.•'��CENSF' ..P DETAILS DETAILS MIDSPAN OF EACH PANEL. ais JAMB:5 ANCHORS,SHEET 13 FOR GEN.LAYOUT. VINYL SLIDING GLASS DOOR NOA E 10/05/15 = h: H°•50705 FOR PRODUCT REFERENCES,ALSO SEE: P-HOOK:7 ANCHORS,SHEET 13 FOR GENERAL - A)SHEET 2 FOR ALLOWABLE CONFIGURATIONS AND EXACT LAYOUT. STRAIGHT DOOR EXAMPLE a J ROSOWSKI LOCATIONS OF CROSS-SECTION DRAWINGS. B)SHEET 10 FOR SPECIFIC GLAZING TYPES. 3 INSTALLATION DETAILS INTO WOOD CAN C SHEET 17 FOR ALLOWABLE PANEL TYPES AND CALL NAMES. CERT•of AurH.la+azoe : F BE FOUND ON: � m �. S 'C�•�. E)SHEETS 4&18 SHEET 18 FOR OR EXTRUSION ADDITIONAL ECTION DRAWINGS. RA IN S. HEAD 6 SILL:SHEET 4 1070 TECHNOLOGY DRIVE _ _ '/,S�C�NA�•� �' JAMB:SHEET 3 N.VENICE,FL 34275 F)SHEET 21 FOR A BILL OF MATERIALS. P-HOOK SHEET (941)-480-1800 SGO-5470 NTS 9OF21 �� MD-5470.0 �$ A.LmE"=PJE` SILICONE HOT-MELT BUTYL STRUCTURAL SILICONE —3AWNOM. STRUCTURAL 1/4"NOM FOAM- POLYISOBUTYLEN WITH 1-1110'Nom. WITH DESICCANT DESICCANT 3/10"T GLAS6 Ts 7B EXT.GLASS EXT.GLASS 11/18"AIR SPACE n Te 3/18"T GLASS pgINTEDI ` LAMINATED ,0LA8B WT.GLASS 82 N /'SURFACE Te KODISPACE SUPER ESTER N PRODUCT IS'EXTERIOR- I I 718"NOM. 4SGTPS Te SPACER®NXT�' TOWARDS THE EXIRID:R. I i IS BITE ``J INTER-OR I I PRODUCT IS'INTERIOR- I 70 GLAZED"IF 082.8315 TOWARDS THE INTERIOR ALUMINUM REINFORCEMENT POLYISO- DESICCANT FILL AREA SUTYLENE 5116"NOM. GLASS DETAIL 5/1 S-NOM. BEAT BUTYL 6 SILICONE SEAL PRODUCT RENEWED DESICCANT ROLL-FORMED_ y y FOAM STAINLESS STEEL NOTES: Bul dlnp lyl Yiwlth 1M pbrlda EXT.GLASS 1)BACKBEDDING SURFACES SHALL NOT BE PAINTED OR LAMINATED. OA-Mo. 15-1210.02 EXT.GLASS 2)PRODUCT MAY BE EITHER INTERIOR OR EXTERIOR GLAZED, Expiration Date 04/21/2021 "T"=TEMPERED By Mla roduct Contfol INT.GLASS INT-GLASS XL EDGE TT SPACER DURASEALO 7e SPACER TN LYNN Pq 2�tj Nc.58705 VINYL SLIDING GLASS DOOR NOA 10/05/15 = = GLAZING DETAILS 8 J ROSOWSKI 0`•, ¢PES6 ` "A STF CERT.of AUTH.#29298 FP1.01101"" 1070 TECHNOLOGY DRIVE N.VENICE,FL 34275 A.LYNN MILLER,P.E. (941)-480-1600 rj�,SGD�-64701NT9 1P.E.v88T00 SILL CLUSTER ANCHORS LAYOUT: SILL"+"INTERMEDIATE ANCHORS LAYOUT: ASTRAGAL OR ASTRAGAL OR PANG INTERLOCK INTERLOCK PANEL PANEL CEWERLINE CENTERLINE CENTERLINE 4' CENTERLINE _4' CENTERLINE 4• 4' o o o & f e FX79_RIQR FYOERIOR EXTEWOR EXTERIOR EXTERIOR 1�I 2-7RACKCUIBTER'C3• 2-TRACK CLUSTER*CV 2-TRACK INTERMEDIATE �/ 2-TRACKINTERMEDIATE �J 2-TRACK INTERMEDIATE ANCHOR LOCATIONS ANCHOR LOCATIONS 'W ANCHOR LOCATION Y2'ANCHOR LOCATIONS •R3'ANCHOR LOCATIONS ASTRAGAL OR ASTRAGAL OR INTERLOCK INTERLOCK PANEL PANEL PANEL CENTERLINE 4" CENTERLINE 4' CENTERLINE CENTERLINE 4'• CENTERLINE qa EXTERIOR -4 -3.22" EXTERIOR 3.22"— — EXTERIOR EXTERIOR 3.2'L" EXTERI .22" 3-TRACK CLUSTER'C3' V 3-TRACK CLUSTER'CW 3-TRACK INTERMEDIATE 3-TRACK INTERMEDIATE '� 3-TRACK INTERMEDIATE ANCHOR LOCATIONS ANCHOR LOCATIONS •N'ANCHOR LOCATION •R2'ANCHOR LOCATIONS '-3'ANCHOR LOCATIONS ASTRAGAL OR ASTRAGAL OR PANEL PANEL PANEL INTERLOCK INTERLOCK CENTERLE CENTERLINE CENTERLINE CEMERIINE IN q• CENTERLINE q^ 41, 0 o e � o o EXTERIOR M�� 3. EXTERIOR — �—3.22' EXTrLERIURR EXTERIOR E%TTEE'-11011 ID I-THACKCLUSTER v 4-TRACK CLUSTER v 4-TRACK INTERMEDIATE 10 3-TRACK INTERMEDIATE v 4-TRACK INTERMEDIATE 'C3'ANCHOR LOCATIONS 'CS'ANCHOR LOCATIONS '*1'ANCHOR LOCATION 'W ANCHOR LOCATIONS 'N'ANCHOR LOCATIONS NOTES: FiGUREsPERTAIN 70 TMFouowwcSILL 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. NOTES: INIERMEDIAIE ANCHOR LOCATRXL9: 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. -- 2)TRACK-TO-TRACK DISTANCE IS 2.376' W2.375. 2)TRACK-TO-TRACK FOR ALL SILLS: DISTANCE IS 2,375' 2.375" FOR ALL SILLS: PRODUCT RENEWED U111111 N!!! HD�RN�SYI 6 1 BPllding ICodawith the P..... \ ��oNl LYNN FIGURED PERTAIN TO TINE FOLLOWING BILL �IOOII 7 NDA-No. 15.1210.02 4F. -•,3CEN$4'•,P,IT CLUSTER ANCHOR LOCATIONS tr e„P "uon O t 04/21/3021 '•.,�� LI VINYL SLIDING GLASS DOOR NOA 10105115 By _ ' No.!i0705 Min 1- •Pro net Control ANCHOR LOCATIONS A p J ROSOWSKI ;� 5t':i W ;per•. . STA ��� CERT.OF RUTH.Y282S8 R Na %� ••.••..• L�`� embitl 61 1070 TECHNOLOGY DRIVE k as ".ANNSS/ONAt;RRT F-hook N.VENICE,FL 34276 -- A LYNNMILLERPE. (941)-480-1800 SOD5470 1 NTS 11 OF 21 4 MD-8470.0 f NN MILLES HEAD CLUSTER ANCHORS LAYOUT: HEAD"+"INTERMEDIATE ANCHORS LAYOUT: ASTRAOALOR ASTRAOALOR PANEL PANEL. `\� INTERLOCK 4• INTERLOCK 4• PANEL CENTERLINE 4" CENTERLINE CENTERLINE CENTERLINE CENTERLINE 4" MERIQ� 3.22• EXTERIOR 3,22• EXTERIOR nnEXTERIOR 3.22• TEnnRIOR 3.22• 2-TRACK CLUSTER-CT 2-TRACK CLUSTER*C6" V 2-TRACK INTERMEDIATE � 2-TRACK INTERMEDIATE v 2-TRACK INTERMEDIATE ANCHOR LOCATIONS ANCHOR LOCATIONS W'ANCHOR LOCATION ANCHOR LOCATIONS 'rJ'ANCHOR LOCATIONS ASTRAGAL OR ASTRAGAL OR INTERLOCKINTERLOCK PANEL PANEL PANEL _ CENTERLINE 4• CENTERLINE 4" CENTERLINE CENTERLINE 475„ CENTERLINE 4" 1- - EXTERIOR. -ti 3.22" EXT fE �RIOR --�1 3.22" EXTERIOR EXTERIOR EXTERIOR K INTERMEDIATE 3-TRACK MEDIATE -TRACK LNTERME(XATF 3-TRACK ANCHO CLUSTER N'Cr �/ J•RACK ANCHOR LOCATIONS 3 1RAANCHOR LOCATION v W ANCHOR LOCATIONS ONS +3•ANCHOR LOCATIONS ` ANCHOR LOCATIONS ANCHOR LOCATIONS ASTRAGAL OR ASTRAGALOR PANEL INTERLOCK-�- INTERLOCK y CENTERLINE CENT RLNNE CENTERUNE CENTERLINE 4 CENTERLINE 4 4 EXT�fE'1R R 3,22" EXTERIOR F�--3.22" EXTERIOR EXTERIOR EXTERIOR - -�- 3.22" 4-TRACK CLUSTER V I-TRACK INTERMEDU.TE 4-TRACK INTERMEDIATE`r2' 4-TRACK INTERMEDUTE'-J' 4-TRACK CLUSTER •r P ANCHOR LOCATION ANCHOR LOCA71ONS ANCHOR LOCATIONS 'CJ'ANCHOR LOCATIONS 'CYANCHOR LOCATIONS NOTES: FIOURE!PERTAIN TO THE FDUOMNGHEAD 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. NTERMEDIATE ANCHOR LOCATIONS, NOTES: 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. DI TRACK-IS 2.37 CK DISTANCE IS 2.376' 2.375" 2)TRACK-TO-TRACK FOR ALL HEADS: DISTANCE IS 2.376" ailElv--l"dinPlyt-9od. 5" FOR ALL HEADS: PRODUCT RENEWED � LYNN Head/SIII 1 ith WmmeFlorlaa OPV F E pp(6�IeFgl READ P hook 7 NOA-No. 154210.02 �a' VLENSF'•.FQ ClUl1ER ANCHOR LOCATIONS. Explratlon Data 04/21/2021 * No.WAY) / VINYL SLIDING GLASS DOOR NOA 10!06/16 Ma -0 Ptudwt Conlrol y I o ANCHOR LOCATIONS B J ROSOWSKI -0 A '•. b� ST r Jamb 5 i�1070 TECHNOLOGY DRIVE -Db 7 N.VENICE,FL 34275 _ - xx (941)-460-1600 SGD•64T0 NTS 12 OF 21 MU-5470.0 4 A.LYNN MILLER,PE. P.E.S 68706 P-HOOK ANCHORS LAYOUT: JAMB ANCHORS LAYOUT,(PARTIAL VIEW): FgIIAESPERTAIN roDIE FOILOYNNOJAYBANC11011LOCAlKSIf 2.375" 4.76" 7.126" 6 l l MAX. HJ—b C3H 21.6" 21.8" 21.8" Jelrih 5 �d MAX. MAX. MAX. P•hook O C EXTERIOR O C EXTE R U.0 EXTERIOR 1 L OPT.ANCHOR - TOAID IN- ALIGNMENT 1 5" a, b' NOTES: MAX. MAX, MAX. 1)STANDARD ANCHOR LOCATIONS SHOWN. FOR 3 1 4-TRACK JAMBS,ANCH 2 TRACK FRAME I 3-TRACK FRAME 4-TRACK FRAME BE LOCA ED N ADJACENT TRACKS R&MAY / JAMB ANCHORS JAMB ANCHORS JAMB ANCHORS (SIMILAR TO THE 2-TRACK JAMB)AS REQUIRED TO MEET MIN.EDGE DISTANCE CONSTRAINTS. 12" MAX, JAMB JAMB JAMB (3)WEEP NOTCHES (4)WEEP NOTCHES (5)WEEP NOTCHES �Y PER END 0 1"X.500" PER END 0 1"X.510' PER END Q 1"X,600' (r SILL SILL � EXTERIOR SILL (� EXTTEERIOR EXTERIO T (3)TRACK WEEP HOLES s"MAX, EVERY 24"01.125"X.190"; \ (6)TRACK WEEP HOLES \ OPT.ANCHOR (1)WEEP NOTCH EVERY EVERY 24"01.126"X.190'; — (10)TRACK WEEP HOLES ` TO AID IN 24'0 1.376"X.600" (1)WEEP NOTCH EVERY EVERY 24"Q 1.126"X.190"; ALIGNMENT 24"@ 1.376"X.500" (1)WEEP NOTCH EVERY 24"@ 1.376"X.600" NOTES: 1)SEE TABLES I&2 FOR EXACT QUANTITY SILL WEEPHOLE LAYOUT(2,3&4 TRACKS) PRODUCT RENEWED LtniiuJ OF ANCHORS REQUIRED IN THE P-HOOK. a,oompiyyl with the fl.ddu ♦♦``L LYNN '��� Betiding Co a ♦ i . FKiMEB PEA TAN/IOINE FOLLOWING POGKlr JAMB NDA-No. 15-1210.02 'N' ""r ENs• _ IP-HOOKI ANCHOR LOCATIONS: - ` ��•:' V @ '•.9 Expiration Pat*04/21/2021 Yf No.60706 d VINYL SLIDING GLASS DOOR NOA 10/05/15 h;,f ANCHOR LOCATIONS C &- J ROSOWSKIsW H�ed1581 CORV 3*1 CERT.OF AUTK 02aZ9B - ii S Junb 5 1070 TECHNOLOGY DRIVES ''pis/ONA1.F�.``♦ P-hook — I — N.VENICE,FL 34275 (9 {� (941)•400-1600 SGDd470 NTS 13 0E 21 64 MD-6470.0 A.LYNN MILLER.P.E. PFJ W706 HEAD 90e CORNER CLUSTER ANCHORS LAYOUT: SILL 90e CORNER CLUSTER ANCHORS LAYOUT: Fo!0F01AEN5G 0-C0RNEgBItL ARCH MLOCA7KS18: Ifln 4- 4" 4 4. Ll .�1 o L4* eHeedISIN 1 jamb I 3 - EXTERIOR - EXTERIOR •hook 7 2-TRACK SO'CORNERR2-TRACH 90•CORNERNER n 'G'ANCHOR LOCATIONS 'C6'ANCHORLOCATIONS `/ 2-TRACK90CORNER TER 2-TRACK 00'CORNER EXTERIOR (USE NA IERE'C3'IS SPECIFIED) (U3EYMERE'C5•IS SPECIFIED) •G'ANCHOR-LOCATIONS '06'ANCHOR LOCATIONS J-L (USE WHERE-CT IS SPECIFIED) (USE WHERE-CW 16 SPECIFIED) PRODUCT RENEWED 614- 4,. 4' 4 —co ft11g with the Florida NOa.A-no Code )�\ j N OA-No. 15-1210.02 jExpiration MIB 04/21/2021 4" 4„ - 4"_. a !y _ min b Pr met Contra EXTERIOR -3.22' EXTERIOR 3'22". 3'22 3-TRACK 90CORNER 3-TRACK 90•CORNER n— 3-TRACK 60'CORNER E IOR 3-TRACK 60•CORNERXTP TERIOR 'C4•ANCHOR LOCATIONS V 'CS'ANCHOR LOCA-TIONS4J` r't (USE WHERE'C3'13 SPECIFIED) (USE WHERE•C6'IS SPECIFIED) 'CI'ANCHOR LOCATIONS 'C6'ANCHOR LOCATIONS 1 y (USE WHERE•C3•IS SPECIFIED) (USE WHERE TV 16 SPECIFIED) v q' q" 4" 4' 4" Na w 3.22" 3.22" F �. 4-TRACK90'CORNER EXTERIOR 4-TRACK 90•CORNER EXTERIOR EXTE EXTER R �i, 'G'ANCHOR LOCATIONS -'06'ANCHOR LOCATIONS ,� 4•TRACK 90'CORNER 4-TRACK 90•CORNER ,SS1ON P , (USE 4'ANCHWHERE RIS SPECIFIED) (USE WHERE IS SPECIFIED) 'C4•ANCHOR LOGA710NS 'CB'ANCHOR LOCATIONS (USE WHERE'C3-IS SPECIFIED) (USE WHERE TV IS SPECIFIED) A.LYNN MILLER P.E. _ NOTES: P'E�6ETo6 FIGURES PERTAIN TO THE FOLLOWING 90'CORNER 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. HEAOAWHORLOCATKIIS: VINYL SLIDING GLASS DOOR NOA $ 10/05/15 90• 2)DETAILS DEPICT ANCHOR QUANTITY AND SPACING,AND WOULD BE ANCHOR LOCATIONS D J ROSOWSKI SIMILAR FOR OUTSIDE(SHOWN)AND INSIDE CORNER CONFIGURATIONS. IN INEdl9Y1 C 1 � -- a Jamb 1 6 3)TRACK-TO-TRACK ® .a P'h00k T—I DISTANCE IS 2.375" 2.376" 2.376` CERT.OFAtnFiY292� « « FOR ALL HEADS AND SILLS: 1070 TECHNOLOGY DRIVE N.VENICE,FL 34276 (941)-480-1600 SOD-5470 NTS '140F21 4 MD-5470.0 HEAD 135°CORNER CLUSTER ANCHORS LAYOUT: SILL 135°CORNER CLUSTER ANCHORS LAYOUT: Fa�NU1�36-CORNER&u ANCNOR LOCAIIDNk 136 4" ° 4" 4' 4" o e 4" • Heedl9tll 1 ER 3 22" EXTERIOREXTERIO EXTERIOR p-hook 7 4" 4" 2-TRACK 196'CORNER 2-TRACK 135-CORNER 2-TRACK 135'CORNER 2-TRACK 136'CORNER 'C4'ANCHOR LOCATIONS 'C6'ANCHOR I OCATIONS 'C4'ANCHOR LOCATIONS 'CS'ANCHOR LOCATIONS (USE WHERE*C3*IS SPECIFIED) (USE WHERE'C5-IS SPECIFIED) (USE WHERE'Cr IS SPECIFIED) (USE WHERE-05'IS SPECIFIED) 4' 4" 4" 4" e e PRODUCT RENEWED q• 4" as complying with the Plodd° Building Ooda 4 J NOA-No. 15-1210.02 ° J ExplradonDat*04121/2021 EXTERIOR E%TERI TERIO_a EXTE IOR (� By 3.22' 3 3.22" MIa -D redual on ro( 3-TRACK 13.`i CORNER 3-TRACK 136'CORNER 'C{'ANCHOR LOCATIONS 'C8'ANCHOR LOCATIONS 3-TRACK 136'CORNER 3-TRACK 135'CORNER (USE WHERE-03.16 SPECIFIED) (USE WHERE-C6'IS SPECIFIED) ANCHOR LOCATIONS 'CW ANCHOR LIGATIONS (USEE WHERE'C3'IS SPECIFIED) (USE WHERE'C5-IS SPECIFIED) 4" #4" , 4' 4" • ��LLYNN • No.58705 jo EXTER)OR � - EXTERIOR E RWR 51%I'L- �� 21�y �—3.22" %�X' a p �`�.' 4-TRACK 135'CORNER v 4-TRACK 135'CORNER v .........•- C� 'C-TRACK 13*CORNER 'CB'ANCIIOR LOCATIONS 4-TRACK IW CORNER A-TRACK 136'CORNER li sS �, (USEYIHEREOR ISSPECIFIED) (USEN81FAEOR IS SPECIFIED) 'C4'ANCHOR LOCATIONS 'C8'ANCHOR LOCATIONS �rI NAi;T of (USE WHERE'C3'13 SPECIFIED) (USE WHERE'CV 18 SPECIFIED) A LYNN MILLER,P.E. NOTES: P.E.r 66706 FKMEe PERTAIN 7071EFOLOWWO/36'COINER 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. HE01DANCRORLOCA7KX1s A VINYL SLIDING GLASS DOOR NOA 10/05/16 136 2)DETAILS DEPICT ANCHOR QUANTITY AND SPACING,AND WOULD BE — SIMILAR FOR OUTSIDE(SHOWN)AND INSIDE CORNER CONFIGURATIONS. ANCHOR LOCATIONS E 114.1J ROSOWSKI HeedlSl6 kc#1 Jamb 5 3)TRACK-TO-TRACK aa P-hook 7 DISTANCE IS 2.376' V2.37V12.376' CERT.OP ALFTH.0202 N FOR ALL HEADS AND SILLS: 1070 TECHNOLOGY DRIVE �a N.VENICE,FL 34275 - -- (941)-480-1600 SGD 6470 NTS I 1S OF 21 XI MD-5470.0 f;? HEAD SPLICE ANCHORS LAYOUT Q INTERLOCK OR ASTRAGAL: SILL SPLICE ANCHORS LAYOUT 0 INTERLOCK OR ASTRAGAL: FIGUR�EES PERRT INNTTOTHI FOLLOWING M� SPLICE SPLSPL ICE LOCATION 4' LOCATION 4' LOCATION LOCATION ]T� 4" 4" EXTERIOR 3.22' E7CTERIOR -- 3.22" EXTERIOR E%TERKM etll9111 C31 2-TRACK SPLICE rFly 2-TRACK SPLICE 2-TRACK SPLICE 2ny 2-TRACK SPLICE Jamb 6 �/ 'G'ANCHOR LOCATIONS v 'CS'ANCHORLOCAiIONS -hDDk 7 'C4'ANCHOR LOCATIONS 'Ca'ANCHOR LOCATIONS (USE WHERE'C3'IS SPECIFIED) (USE WHERE'C5'IS SPECIFIED) (USE WHERE'C3'IS SPECIFIED) (USE WHERE'CS'I3 SPECIFIED) SPLICE SPI.I(;E SPLICE SPI ICE LOCATION - I.00ArICN 4" LOCATION 4" LOCATION 4" 4.76" 0 0 PRODUCT RENEWED -- ying EXTERIOR —4" EXTERIOR -3.22" EXTERIOR —3,22° EXTERIOR 4" Bwith the Florida UIIdIno as complCodi lu 3•TRACKSPLICE 2 y 3-TRACK SPLICE n 3-TMCKBPUCE ANCHOR No�No. 15-1210.02 �v/ 'CO' NS ANCHOR LOCATIONS V 'CS'ANCHOR LOCATIONS �J 'C4'ANCHOR LOCATIONS E W ANCHOR LOCATK IFI (USE VAIEHE'C3'18 SPECIFIED) (USE WHERE'05'IS SPECIFIED) (USE 1ARiERE'C3'I6 SPECIFIED) (USE WHERE'C6'IS SPECIFIED) Expiration Dob 04/21/2021 sy Mlaml roduet ontro SPLICE 4.76" SPLICE SPLICE_ SPLICE__ LOCATION LOCATION 4' LOCATION LOCATION 4- SPLICE 0 0 o e EXTERIOR EXTERIOR EXTERIOR --3.22 EXTERIOR tLtlt I/F��i q" 3.22" —3.22" ��Ny 1YNN i� 4•TRACKSPLICE 4-TRACK SPLICE ANCHORLOCAE ANCHOR SPLICE �`.10,••G�NS •'•`F'p,�i 'C/'ANCHOR LOCATIONS -06*ANCHOR LOCATIONS ANCHORLOCATIONS 'CS'ANCHOR LOCATIONS .�. •�,� N IS SPEC (USE WI IERE'C3'IS SPECIFIED) (VSE (USE WHERE'C3'IS SPECIFIED) (USE WHERE*CV 15 SPECIFIED) WHERE-C6' FIED) 1R.;' '••�(i Wo.607U5 � NOTES: ���'•• lolt�t?!. 1 ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. pill I r / FIGURES PERTAINW TO THE FOLLOWING SPLICED 2)ABOVE FIGURES ARE FOR SPLICES OCCURRING AT THE ASTRAGAL OR INTERLOCK. A.LYNN MILLER,P.E. HEAD ANCHORLGCATwNF: FOR SPLICES OCCURRING INSIDE OF A POCKET,SEE THE EXAMPLE ON SHEET 9. L P.E.a 66705 3)TRACK-TO-TRACK VINYL SLIDING GLASS DOOR NOA A 10106116 DISTANCE IS 2-376" W2-375- 12.376" FOR ALL HEADS AND SILLS: ANCHOR LOCATIONS F J ROSOWSKI OF RUTH.112S2S8 • He III C 1 4)POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND 13 TO BE DESIGNED CERT. � — Jamb BY OTHERS AND REVIEWED BY THE AUTHORITY HAVING JURISDICTION. 1070 TECHNOLOGY DRIVE P-hook 7 N.VENICE,FL 34275 (941)-480-1800 SGD-6470 NTS 111 16 OF 21 id MD-6470.0 >! PANEL'S RIGHT STILE TYPE SCREEN PANEL TYPES PANEL - - OUTSIDE 90 INSIDE 00' OMSIDE133• INSIDE135' C DOUBLE ASTRAGAL TYPES SINGLE fNGLE FIXED LOCKSTILE ASTRAGAL ASTRAGAL ASTRAGAL ASTRAGAL ASTRAGAL ASTRAGAL IMENLOCK INTERLOCK WTE"LOE STILE WI HANDLE BOX OUT BOX IN RECEIVER RECEIVER IMERIOR OR 011i IN RECEIVER RECEIVER EXTERIOR 0DOUBLE M p --LI+ LCN9TILE MERLOCERLOCK INTERLOCK J LOCKBTILE °RLO E F PP K L L TC TA TV TW r-1 nhvv".n.� ASTRAGAL OUT owwo fwX C _ �•�q BINDLE B H P /� C Cj SIC SA S1/ SW SD INTERLOCK �--I� ci INTERLOCK INTERLOCK /u� �,/ 1/ V�/ LU N PW a"" �eRR R S S FC FD FV FW A INTERLOCK �KSTILEE "m IllX" Uj LOCKSTILE -J WTHANDLE D M J J U ABTRAOAL � � LODKBTILB �wo WXw F NTUL 'LO'B3OMOGUATL LR T U DS INTERLOCK INTERLOCK � /1TDUn JASTRAGALN T U BOXINX N - flimme awfaOIr110 W " CT CS -CF LL.I ASTRAGAL z RECEIVER ASTRAGALT a- RECEIVER A■ AS DF OUT 135• VT VS VF PRODUCT RENEWED ASTRAGAL as cometying with the Florida RECEIVER Building Codi IN.A .WT WS WF NOMNo. 18.1210.02 RAG ASTAL RECEIVER Expiration Ode 04/21/2021 By Ml�m- •Pr oct Con ro LEFT RIGHT PANEL m r PANEL STILE STILE PANEL TYPE"F'SHOWN. PANEL NOTES: 1)SEE DPIANCHOR TABLES 1&2,SHEETS 7-8 FOR PANEL SIZES d DESIGN PRESSURE. 2)PANEL TYPES NOT SHOWN ARE NOT REQUIRED FOR ANY CONFIGURATIONS AND ARE [SG L SLIDING GLASS DOOR NOA 10/05/15 i�' No.58705 NOT AVAILABLE. 111 EL TYPES P J ROSOWSKI ='o IGS ` : 3)MAXIMUM NOMINAL PANEL WIDTH FOR ALL PANEL CONFIGURATIONS IS t10". e � v1 F : 'I4)PANEL TYPE MAY BE EITHER EXTERIOR(STANDARD)OR INTERIOR GLAZED,BOTH CERT.oP AUTH.N2BSBeTYPES QUALIFIED BY THIS APPROVAL,SEE DETAILS SHEET 10. 1070 TECHNOLOGY DRIVEN.VENICE,FL 34275(941)•480-1800 -5470 NTS 17 OF 21i MD-5470,0 # A LYNN ABLLfRPE -- _ _-- P.E.g -P -6.875- r291 081 I yl. 10.836 -►1 540 .125r-.560 1, 782 _ 100 ��� � 1.812 (�- 1.881 JS00 .082 --.930 .301 � � 1�I� 100 d� _-� FILE SCREW � SRT 10 INTERLOCK CAP, Q 2 TRACK HEA01JAM8 Q 4 TRACK SILL COVER{PVC) O ANCHOR PLATE Q TRACK INE O EXTENDED POCKET 5.178 1.000 262 .231 .080 '-'^� 2.080 r- ,100--� �- -- .260 ��� -8.250 082 1.813 r I 080 100 g4g 1.496 X111.883 1.813 1.681 . I �If'-082 T -� .060 rl.lo) + dG��� CJ 111 BOTTOM TRAIL ©ADD FRAME LL 0 COVER SILL CK 1Q P-HOOK ADAPTOR ©P-HOOK Q 3 TRACK HEAD/JAMB `J 3 TRACK SILL SUPP229 084 r 126 I� 640 .291 �, r 2.975 L 2.141 r 10.826 -- - ��_ 6.875 �'I x•640 3.000 :3= p1 .075 nI [ O� O 100 -f 82`8 Ip1 .600 _.082 2.807 •I� 1.400 8 .328 r p . o .100 ❑ -3 A 1 19 ET�DDED ®p KEEPER BAR COVER ®REINFORCEMENT @ FIXED PANEL CLIP P� ORCEMENT TE `J 4 TRACK HEAD/JAMB @ 2 TRACK SILL 2.511 1 � � I►-2.898 -�1.670 V--ii 1.826 1.595 �- - 1.595 r- .309 -2.696 I .080 2.0� 099 T 3.483 A 26 p -.070 .076-� 4.835 4'27 .100 2.833 2.368 Q .768 .400 768 F 10 Ogp 2.118 1 .300 8 2.025 .312 +nf -- j ®INTERIOR JAMB COVER .L-.�•�.168 -` �F.-2.710 ` 1.876 PRODUCT RENEWED .110 1+ .120 -rIF+-.182 .120 1-.-.182 .2287 .100 arc qo TOP,BOTTOM TOP,BOTTOM INTERLOCK.300 o pl ing with the Florida INTERLOCK.400 4),ASTRAGAL 0 E%TENDED POCKET 3 INTERLOCK 2 ASTRAGAL ADD-ON (@ PANEL STILE TOP NOA'NO.�oda 15.1210.02 AND STILE AND STILE ©REINFORCEMENT, ®REINFORCEMENT, REINFORCEMENT ®INTERLOCKADAPTER ©ADAPTER © ©AND BOTTOM RAIL REINFORCEMENT COMPOSITE STANDARD HEAVY-DUTY Explratlon Date 04/21/2021 REINFORCEMENT 3.328 e Imo--3.345- NOTES: Mian1- rodue Control -3.462 --- 1.472 919 1)SEE SHEET 4 FOR .126 3.208 3.713 .090 SILL RISERS. 080 2.17625 .048li20 0 3.247 3.946 2)SEE SHEET 20 .070 1 .086 •919 FOR SCREEN PARTS. 300 1.170 1 - 135'CORNER 136'CORNER 135'CORNER 135•CORNER 90'CORNER 90'CORNER 90'CORNER 3)ALL DIMENSIONS ASTRAGAL �PASSIVEMOUNT ®ASTRAGAL CAP, ®ASTRAGAL CAP, ASTRAGAL 40 ASTRAGAL CAP, ®ASTRAGAL CAP, IN INCHES. ```ttl1IIIIItt���' EXTERIOR INTERIOR EXTERIOR INTERIOR �� 14 LYNN •dol'........... 210p� 252 VINYL SLIDING GLASS DOOR NOA 10!06116 = h �No.50705�, )p1.281 1281 EXTRUSIONS 3 J ROSOWSKI p /�tf�-� I( _ r 1-1/18" S6 •'••.EZORIDt;.•'• \ C� CO3� CERT. _- .. ..• �C9` BEVELED BEAD OGEE BEAD o � 'i�'S n ' - 1070 TECHNOLOGY DRIVE N.VENICE,FL 34275Lt t l l l t l t l (941)-480-1600 SGD-5470 NTS 18 OF 21 MD-5470.0 p f " VRE'y p py p� 1)INSTALL 0"1-.1 2)INSTALL CLIP HEADER BLOCK TO HEAD JAMB TO HEAD (4)ANCHOR CLIP INTO INTO FRAME ATTACHMENT _- TYPE AS USED PANEL ° ° JAMB& INSTALL ONE BLOCK AT 84 HEADER ASSEMBLY IN INSTALLATION, STILE SUBSTRATE,SEE EACH INTERLOCK. BLOCK TABLE A,SHEET 1 TABLE 1 AT ASTRAGAL,INSTALL (3)#10 X ° ONE BLOCK THAT 1.61' SMS SPANS BOTH PANELS. (3)#8 X (9°�1"SMS i NO FIXED PANEL CLIP l FIXED INSTALL ONE CLIP AT THE 23 PANEL MIDSPAN OF EACH FIXED (2)1/4" CLIP PANEL-TO-FRAME JAMB LOCATION. X 2-1/4"SMS #8S boa) 2i BAR COVER X 2"SMS ®° 22 REINF.BAR #8 X 1-1/4"SMS i \ KEEPER 1e �1 - JAMB TO O SILL ASSEMBLY KEEPER TO JAMB\\ I ATTACHMENT LOCKING JAMB PRODUCT RENEWED REINFORCEMENT PLATE as complying with the Florida t\ [ Building Code ATTACH WITH#8 X 1-1/4" 4-PANEL,2-TRACK1, Non-No. 15.1210.02 34-1/2"MAX O.C. OXXX SHOWN KEEPER t9 Expiration Date 04/21/2021 l� By - 1 Mlatnl-D iroduct Control — (4)#10 X�_ o� 2"SMS eo INTERLOCK - INTERIOR CLIP COVER INTERLOCK NOTES EXTERIOR (24)INTERLOCK PLATE 1)DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. ° #10 X 2)SEE SHEETS 11-18 FOR ANCHOR LOCATION&SPACING. IVYNN BOTTOM RAIL/t 1 ��� 3)SEE TABLES 1 6 2 FOR REINFORCEMENT REQUIREMENTS. SUPPORT) 2-1/2"SMS 4)CONTINUOUS ANCHOR PLATE,ITEM#8,IS REQUIRED AT ALL FRAME ANCHOR LOCATIONS.:' J4FNSe '`c9 #H 1" (2) X SMS A 10/06/16 - THROUGH SUPPORT,9x VINYL SLIDING GLASS DOOR INCA = "� No.`'B70' INTO PANEL ` PANEL 93#1 o X ACCESSORIES INSTALLATION atJ ROSOWSKI ;•ri Q [>:- INTERLOCK SILL RETAINER 1-1/2"SMs ASSEMBLY ;Pn'. ZPA�5�l6 lig, ALL PANEL CORNERS CERT.OF AUTH.12Y290F[olro�.• CLIP ATTACHMENT WELDED,NO ASSEMBLY °+ — -- '%cSt ..v I INSTALL ONE ASSEMBLY AT EACH INTERLOCK FASTENERS 1070 TECHNOLOGY DRIVE i' 0NA%- � 1 1G�\ N.VENICE,FL 34275 -- ��..11 n n ll`� (941)-480-1600 SGD-13470 NTS 19 OF 21 4 MD-6470.0 �i n LYNi1MILLEK PE. BOX SCREEN DETAILS: STANDARD SCREEN DETAILS: 1 3 5 O 121 _ 10e 6 125 132 1N of HORIZONTAL SECTION - HORIZONTAL SECTION EXAMPLE . 130 EXAMPLE Its I 33 102 1N 2 131 � - a "& 117 �/- �2z 3 s ,te ' � HORIZONTAL SECTION EXAMPLE too 112 ftp ,w HORIZONTAL SECTION 117 1,981 102 EXAMPLE 1.081 �-f 1.202 1.7l78 1.778 .� 876 �.. 876 Y� 1.020 I�- ' 060 .�It-050 045 OSCREEN 1Y18CREEN 122 SCREEN OXO 1.993 1.993 1.8174 FRAME SIDE RAIL, ASTRAGAL L L L RAIL LATCH ADAPTER 002 -�II .062 .062 PRODUCT RENEWED STOPSCREEN 10f BOXSCREEN tp BOX SCREEN an-o PI Jag Ith the llorldo TOP RAIL BOTTOM RAIL SIDE RAIL I� 725 }+-11.436 F� NuIlding OMNo.� 15.1210.02 tv 786' 7P+.0-62 ExWAtlon Dot.04/21/2021 OR 1.020C72 --- 1.593 --.-11.9731--- 12a 12D040 Mtl.,ni �d- o.ko. 101 - SCREEN VINYL FRAME SILL 2 • ` .003 �7-'ASTRAGAL 121 SCREEN 1. 2 + e 1,833 ADAPTER ADD-ON O y 12+ ,07 8 +-.062 11 r-.372 I_ g ,05 BOX BOX SCREEN 10+SCREEN 10S OXOSCREEN Q INTERLOCK SNAP-ON ASTRAGAL VERTICAL SECTION BUG FLAP ADAPTER 111 EXAMPLE VERTICAL SECTION \�.` Ny LYNN, ro,5,0 08 EXAMPLE NOTES: U<<i`➢ 056 1'4871)ALL DIMENSIONS IN INCHES. �- 1.467 1� 1.610ro VINYL SLIDING GLASS DOOR NOA �14, J 10106/15 140.98705 tib — 0 SCREEN DETAILS SOWSKI 7 BOX SCREEN BOX SCREEN BOX SCREEN HEAD 100 ASTRAGAL 107 SILL ADD-ON 100 AND JAMB ADD-ON • - - � Fr fC r c4� CERT.OF AUTH. ADAPTER 1070 TECHNOLOGY DRIVE %,`,10NA%_ 'No"�\ N.VENICE,FL 34276 tiLYNN tNUPRP.e (941}480-1600 SGD-5470 1 NTS 20 OF 21 f MD-5470.0 —. _. P.E#3!706 TABLE C: TABLE D.BOX SCREEN 0 Party Description Material 0 Part0 Description Material 0 I Part8 Desedp0on Material 1 10001 2-Took Hs Jamb Rlgl PVC 40 HOW 90'Comer Astragal Cap-Ext. Rigid PVC 100 1 12268 Ism Screen Top Roll 5083 T6 AI 2 10002 2-Took$III Rigid PVC 41 10062 90'Comer Astragal Cep-Int. Rlpld PVC 101 12267 Box Screen Bottom Roil 8083 75 At 3 10025 3-Track Hoo d/Jamb Rigid PVC 42 19085 SItt Riser-(2-117) 6083-T8 Alum. 102 12268 Box Screen Side Reg WM T6 At 4 10028 3-hack Sol Rigid PVC 43 19022A SIII Riser-(3417) 8083-T8 Alum. 103 84428 Box Screen Interlock 6053 TO At 6 1902-/ 4-Treak Head/Jamb Rigid PVC 44 19023A 810 Riser-(44118') 6083-TE Num 104 17347A Boot Screen 8nspon Bug Flap 8063 T8 At 6 19028 4-Track SIN Rigid PVC 46 19024A SIN Riser-(4!/8•) 8083-T8 Akxn 105 04346 Box Screen OXO AsingU Adapter am T8 AI 7 19009 Frame Screw Cover Rigid PVC 60 710009W .187'x.320'Finseal(81118) 1011 7349 Box Screen Ashegal Adapter 6053 TS At 8 19031 Anchor Plate 8063-T8 Alum. 61 71695K 1-1/21 x 1'x 314•Fin Seal Dust Plug 107 18038 Box Screen Frame Bill Add•m BOBS 76 Al 9 19007 Track Insert 6083.78 Alum. 52 71698 Dust Plug 108 19036 Box Screen HaedlJamb Add-on e083 78 Al 10 19084 Intedock Cap-Extended Pocket Rigid PVC 60 419041 Interlock Clip Cover PVC log 72=X 014-20 x 1"MS Q Top Nall as 11 19038 Bottom Rall Support 0063-T6 Alum. at 781 63)( Tandem Roller Assembly SS 110 720X112)( 01420 x 1-117 MS 0 Bottom Rall as 12 19008A Outer SIN Cover 8063-T6 Alum. 82 78163N Tandem Roller Assembly Nylon 177 717830 Welp,•270"x AW'-Fin Seel 13 10011 8111 Track Coter Rigid PVC 83 7BX75FPTX 08 x 314'Ph.FH SMS 0 Roller&Reinf. as 112 61B06K Walp,All?"x.600'0 Bug Flop 17 19032IP-Hook Adopter 806348 Alum. 64 419042 Frame Header Block Nylon 113 7BRAZ Standard Roller Nylon 18 19020 P+Hook 8063-TB Alum. 85 48052 Roller Ad).Hole Plug PVC 114 7SRAX HO Roller Be 19 19047M Extended Keeper 0063-Ta Alum. 88 44385 4 Hole Bumper Slop PVC 116 tadw Screen Locking Hardman Steel 20 19029M Keeper 0063 TB Alum. 67 70X114FPIX k8 x 1414'Ph.FH SMS®Bumper Slop SS 116 418063 Sown Keeper steel 21 10014 Reinforcement BarCoter Rigid PVC 88 718080 SIN Plug PVC 117 76XIPPA NO It l"Ph.PH SMS Sled 22 10030 Reinforcement Bar 8005-T6 Alum. 89 78l86X Geminl Morgan Look vdiong Trim plate 8led/S8 718 1682/3/4 Screw Spline-.160 &.186 Vinyl 23 IDD37M Fixed Panel Clip 6063-TO Alum. 70 71D32)0FPFX 1032 x l"Ph.FH MS 0 Look gg 119 1818020 Semen oath F ass 24 19036M Reinforcement Plate 6083-78 Ak,m. 71 tad" Hands K8 Cut Zino TABLE E:STANDARD SCREEN 25 10017M Top Reil,Bottom Rail and Laksllls 8006-T6 Alum. 76 Kommeding 480 TP8 Spacer System 0 Part 0 Description Material 2a 19046 Reinforcement Composite 76 Quanex Super Spacer NO'wah Hot MoR Butyl See Sheet 27 19018M Intedock.300 Reinforcement,Sid. 6005-T5 Alum. 77 Quarox Duraseel 10 for 120 12033 Screen Frame Rall W63 T5 Al Materials 121 12028A Screen Frame-Side Reil(Latch) 0083 T5 At 28 19013M Intedock.400 Reinforcement,HO 0005-76 Alum. 78 Cardinal X.Edge Spacer 122 17363 Screen OXO Astragal Adapter W63 T8 At 20 10019M Astragal Reinforcement 8006-T6 Alum. 79 Dow Coming 995 a GE-7700 Beckbedding Silicone 123 4853K Screen Vinyl Astragal Adapter Rigid PVC 30 19093 Extended Pocket Warlock Adaptor 6063-T8 Alm. 82 19044 1-1/18'Bowled Beed Rigid PVC 124 190128 Frame 6111 Screen Add-on 6083 T6 At 31 18008 Interlock Adaptor Rigid PVC 83 18045 1-1116.Oges Bead Rigd PVC 426 6FP95K Bug Flap,96+/-6 duro. Vinyl 32 10008 Astragal Add-on Rigid PVC Be 71726K Setting Block V x 4'x 11191,e6+/-6 duet. Neoprene 120 78X112P8AT8 118 x 1-1/Y Ph.PH SMS(Assembly) 68 33 1900{ Panel Stile,Top/Bottom Rail Rigid PVC 90 781PSTX 08 x 1'Ph,PH BMS®Frame Assembly SS 127 712027 Coiner Key Wheal Assembly(Standard) Nylon 34 19040 Interior Jamb Cover 6063-TB Alum. 91 78X114PHPT410X 08 x 1-1/4'Ph.PH SMS 0 Relnf Bar SS 126 71202753 Caner Key Wheel Assembly(HD) 88 36 19078 136•ComerAslragal 6(163-76 Alm. 92 710XIPHPTIM 010 x V Ph.PH SMS 0 Rail Support SS 129 varies Screen Locking Hardware sled 39 19077 135•CornorAstragal Penske Mount 6083-Te Alum. 93 710X115PPX 010 x 1412'Ph.PH SMS 0 Fxd.Pnl•Gip as 130 710X34PPODAX 010 x 314'Ph.PH SMS 0 Screen AM. 88 37 19079 136'Corner Astragal Cap-Ext. Rlgld PVC 94 710 0.5PHPT1641X 010 x 24/2'Ph.PH SM8 0 Relnf.PlielotAsl. as 38 19080 136'Com rAelagal Cap-Int. Rigid PVC 96 71420X2.26FPFX 012 x 2-114'Ph.PH SMS 0 Hdr.Block as 131 78X12112JY4 08 r 1/Y lin -.SMS DoaAsl. 33 39 19078 90•Comer Ashagd 8083-TB Alum. gB 710X1.75PPX 010 x 1.814'Ph.FH SMS 0 Keeper its 132 18021314 Screen Spline-.145' Vinyl 133 1818020 Screen Goth Flbergese 97 710X34PPX 010 x 314'Ph PH SMS 0 Ext.Pkt.Int. SS PRODUCTRENEWEDtRENEWEDo. h the riaa t�`�tt•(II.YNf4rrr7�/� Building Code •••.••.'N4'tF NOA-No. 15-1210.02 �tCt.N,SF'••, .p Expiration On 04/21/2021 ;1• • No.50705 - VINYL SLIDING GLASS DOOR NOA 10/06/15 By 7 Mia -_ ro uct Co trot -13 PARTS LIST J ROSOWSKI =•)3 •. l b :.�v' () STA NOTES: CERT.of AUTH./211296 �UNnI_ 1070 TECHNOLOGY DRIVE 1)ITEMS 014-16,46.49,53-59,72-74,80,81,84,85.87-89.08&99 ARE NOT }4 USED AND ARE NOT PART OF THIS APPROVAL. N.VENICE,FL 34275 (941)-48071800 SGD-5470 NTSill 21 OF 21 P i� MD-6470.0 1 A LYEl MILLER.P.F. If . .a 68705