Nichiha USA,Inc.
6465 E.Johns Crossing
Johns Creek,GA 30097
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted liy Miami-Dade County RER-
Product
ERProduct Control Section to be used in Miami Dade County and other 'areas where alimved by the'Authority
ITaving Jurisdiction(AIS.
This NOA shall not be valid after theexpiration date stated.below.The Miami i Dade County Product Control
Section(In Miami Dade County)and/or the AIU(in areas other than iVliami Dade County)reserve the right
to have this product or material tested for quality assurance purpose's. If this, product.or material fails to
perform in the accepted manner, the manufacturer will,incur the expense of such testing and the AWmay
immediately revoke, modify, or suspend the use of such product or material -Within iheir jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County product Control
Section that this product or material fails to meet the requirements.of the applicable building code.
This.product is approved as described herein,and has been.designed tocomplyyith the Florida Building,
Code,including the High'Velocity Hurricane Zone.
DESCRIPTION:NichiProduetsTM Fiber-Cement Siding
APPROVAL DOCUMENT:Drawing No.ITS N1090403,titled"NichiBoard&EcoPlank",sheets I and 2
j of 2 and DrawingNo.ITS N2090403,titled"NichiPanel",sheets I andl�2 of 2,d oth dated 03/1612009,
j prepared.by Nichiha USA;Inc,signed and sealed by Carl D.Fussner,P,E.on 07/10/2014,.beating the Miami-
Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by.
the.Miami-Dade County Product Control Section.
MISSILE IMPACT RATING:Large and Small Missile I9pact Resistant,
LABELING:Each unit.shall bear a permanent,label with the manufacturer's name or logo,city,state and
. following statement: "Miami-Dade County Product'Control.Approved"I unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a_renewal.application has been filed and there has been.
j no change in the applicable building codenegatively affecting the pormance.4 this product.
TERMINATION of this NOA will occur after.the expiration date or if there lies been a revision or change
in the'materials,use and/or manufacture of the�product or process.Mrs
any product,for sales,advertising or any other purposes shall automaticuse of this NOA as an endorsement of
ally to ii7matejthis NOA.Failure to
comply with any section of this NOA shall be cause for termination and removal ofNOA:
ADVERT15EMENT:The NOA number_preceded by the words Miami Dade;County,Florida,and followed
by the expiration date may be displayed in advertising literature. If any,portion,of the NOA is displayed,then
it shall be done'in its-entirety.
I
INSPECTION:A copy of this entire NOA shall.be provided-ta the user by the,manufacturer or its
j distributors,and shall be available for inspection at the job site.at the request of the Building Oficial.
This NOA renews and revises NOA#09-0511.01 and consists of this;page I and evidence pages E-1 and E-
2,as well as approval document mentioned above.
The submitted documentation was reviewed by Carlos M.Ut era,P.E.
i NOA No.14-0-715.03
Murrti•nanFeourtrtr Expiration Date:July 22,2019
.••• , Approval Date:January 29,2015
Page 1
I
I
i I
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number: 1�!&– os]w
' I
TIN
Taira
r F
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential ,C
PERMIT APPLICATION FOR:
PRP�SED INPR01%EMENT LC#CATKIN
Address: -Wo Z ,ix i Rr4
Legal Description: '
Property Tax ID#: 1301- (00q-
d 073. 0003 I ! Lot No.
Site Plan Name: ! h.. Block No.
Project Name:
Setbacks Front Back: Right Side: Left Side- I.;
s ., #=� ��
DETAIL--
ED-PEDESCRIPTIQIV:C7F WORK: 9
� r ��
?o-r iJ ie E#/ Ag�, .LL- r7
i
I �
3
CQNSTRUCTIQN INFORMATCON 8
s p
Additional worK to be performed under t is permit–checK all tat appy:
i Mechanical Gas Tank Gas Piping Shutters 1 Windows/Doors
—Electric —Plumbing —Sprinklers —Generator j .—Roof Pitch
I �
Total Sq. Ft of Construction: Sq. Ft. of First Floor:
I
Cost of Construction:$ Utilities: —Sewer _Septic I. Building Height:
ER/LESS" ,
CONTRACIV, g m a
Name f±v t, 4- 6 A4--Tys 2-,,.r X Name:
Address: 71102— 5 -96AsT) /4-r( &9 Company:
City: .C_T_ 12 /.2c F,, State: t'L Address:
Zip Code: 3�6S / Fax: City: ! State:
Phone No. -7 3-7 Zip Code: I Fax:
E-Mail:�.a rry�r hoz v t='T Phone No
Fill in fee simple Title Holder on next page(if different E-Mail
from the Owner listed above) State or County License
I .
If value of construction is 2500 or more,a RECORDED-Notice of Commencement is required.
i I
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number: 1�!&– os]w
' I
TIN
Taira
r F
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential ,C
PERMIT APPLICATION FOR:
PRP�SED INPR01%EMENT LC#CATKIN
Address: -Wo Z ,ix i Rr4
Legal Description: '
Property Tax ID#: 1301- (00q-
d 073. 0003 I ! Lot No.
Site Plan Name: ! h.. Block No.
Project Name:
Setbacks Front Back: Right Side: Left Side- I.;
s ., #=� ��
DETAIL--
ED-PEDESCRIPTIQIV:C7F WORK: 9
� r ��
?o-r iJ ie E#/ Ag�, .LL- r7
i
I �
3
CQNSTRUCTIQN INFORMATCON 8
s p
Additional worK to be performed under t is permit–checK all tat appy:
i Mechanical Gas Tank Gas Piping Shutters 1 Windows/Doors
—Electric —Plumbing —Sprinklers —Generator j .—Roof Pitch
I �
Total Sq. Ft of Construction: Sq. Ft. of First Floor:
I
Cost of Construction:$ Utilities: —Sewer _Septic I. Building Height:
ER/LESS" ,
CONTRACIV, g m a
Name f±v t, 4- 6 A4--Tys 2-,,.r X Name:
Address: 71102— 5 -96AsT) /4-r( &9 Company:
City: .C_T_ 12 /.2c F,, State: t'L Address:
Zip Code: 3�6S / Fax: City: ! State:
Phone No. -7 3-7 Zip Code: I Fax:
E-Mail:�.a rry�r hoz v t='T Phone No
Fill in fee simple Title Holder on next page(if different E-Mail
from the Owner listed above) State or County License
I .
If value of construction is 2500 or more,a RECORDED-Notice of Commencement is required.
5UPPLEMENTItL CONSTRUCTION LIEN:LAW INF�RlUTATIQN o
DESIGNER/ENGINEER: Not Applicable/ , MORTGAGE COMPANY: Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
OWNER/CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize thepermit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencing work or recording our Notice of Commencement.
Signature of Owner/Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder
STATE OF FLORIDA STATE OF FLORIDA
COUNTYOF S_�_• COUNTYOF
The,fomoing instr ment was acknowledged before me The forgoing instrument was acknowledged before me
this day of 1 201a by this day of 20_ by
(Name of person acknowledging) (Name of person acknowledging)
(Si ature of Notary Public-S to of Florida) (Signature of Notary Public-State of Florida)
Personally Known OR Produced Identification Personally Known OR Produced Identification
Type of Identification Type of Identification
Produced JM `�`� �
L
ASHANNA IN6RANI Produced
tP 9�i
Notary Public-State of Florida
Commission No. hU rt My Con(Seal))ires Dec 20,20-18 Commission No. (Seal)
'N�FOF F4�M` commission#FF 17724° (,
�'• Bonded throuah National Notary Assn !
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
ev.
5UPPLEMENTItL CONSTRUCTION LIEN:LAW INF�RlUTATIQN o
DESIGNER/ENGINEER: Not Applicable/ , MORTGAGE COMPANY: Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
OWNER/CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize thepermit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencing work or recording our Notice of Commencement.
Signature of Owner/Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder
STATE OF FLORIDA STATE OF FLORIDA
COUNTYOF S_�_• COUNTYOF
The,fomoing instr ment was acknowledged before me The forgoing instrument was acknowledged before me
this day of 1 201a by this day of 20_ by
(Name of person acknowledging) (Name of person acknowledging)
(Si ature of Notary Public-S to of Florida) (Signature of Notary Public-State of Florida)
Personally Known OR Produced Identification Personally Known OR Produced Identification
Type of Identification Type of Identification
Produced JM `�`� �
L
ASHANNA IN6RANI Produced
tP 9�i
Notary Public-State of Florida
Commission No. hU rt My Con(Seal))ires Dec 20,20-18 Commission No. (Seal)
'N�FOF F4�M` commission#FF 17724° (,
�'• Bonded throuah National Notary Assn !
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
ev.
I L ,
Nichiha USA,Inc. I
1
• NOTICE OF ACCEPTANCE: EVIDEISUBMITTED
I, t
NCE SUBMITTED
j
A.. DRA'WIN'GS i
1. Drawing No.ITS N1090403,titled"NichiBoard&EcoPlank",sheets 1 and 2 of 2 and
Drawing No.ITS 1`F2090403,titled"NichiPanel",sheets I f and 2 hof 2 both,dated
03116/2009,prepared by Nicliiha USA,Inc,signed Wand sealed by;Carl D.Fussner,P.E.
on 07%10/2014.
B. TESTS."Submitted undterNOA#09-051.1.01"
1. Test reports on 1)Air Infiltration Test,per FBC,TAS.202=54
2)Uniform Static Air Pressure Test1 Loading per�FBC TAS 242-94
3}Water Resistance Test,per FBC,;TAS 202-94;
4)Large Missile Impact Test per FBC,TAS;201=94
11
5) Cyclic Wind Pressure Loading per 1713 01";TAS 203-94
along with marked up drawings and installation diagram of NichiProducts Fiber-
CementPanels,prepared by Intertek Testing'Services NA,LTD,Deport No.
3145127COQ-004A,dated 08/07/08,signed and sealed by„RicklCurkeet,P.E.
2. Test reports on 1)Uniform Static Air Pressure Test,'I Loading per,FBC TAS 202-94
2}Large.Missile Impact Test per FBC,TARS 201;94
3)Cyclic Wind Pressure Loading per FBC,TAS 203-94
along with marked-up drawings and installation diagram'cif,NieliiBoards and
EcoPlanks,prepared by Intertek Testing,Services NA LTD;Report No.
3145127COQ-W!3B dated 10/24/08,signed ai4sealed by Rick1Curkeet,P.E.
3. Test report on Standard Specification for Flat Non-;Asbestos Fiber=Cement-Sheets of
NichiProducts Fiber-Cement Panels,per ASTM 61186-6 prepared by'Intertek
Testing Services NA LTD,Report No.,31451123GOQ-045;dated 05120/08,witha,
revision dated 02/02/09,signed andsealed by Rick 16u skeet P.E.
-4, Test report on Surface Bui-ging Characteristics of N” Finer-Cement Panels,
per ASTM E84'08,prepared.by Intertek Testing Services rNA LTD,Report No.
3145123COQ-U06,dated 06/25/08,with a revision dated�04/03/,09,signed and-sealed
I by Rick Curkeet,P.E. I .I
5. Test report on Standard Test Method for Behavior,of Materials in a Vertical Tube
Furnace at 750*C of Nichiha M series unprirned cementitious;per ASTM E136-99,
prepared by Intertek Testing Services NA LTD,Report No.3105885COQ-002,.dated
I� 10/26/06,with a revision dated 03/30/09,signed ar'l seal{ed.by(tick Curkeet,P.E.
• i', � Carlos:M.Utters,T.E.
Product Control._ninnies
NUA N6..14-0715,03
i Expiration Date-July 22,2019
Approval Dates January 29,2015
1
Nlebiha USA,Inc.
i
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
i
C. CALCULATIONS
1. Anchor calculations prepared by Progressive Engineering,.1nc.,dated
10/22/2014,-signed and sealed by Carl D.Fussner,P.E.
"Submitted wider NOA#09-0511.01"
2. Anchor analyses prepared by Category 5 Engineering Services,1c.,dated
04/0372009,signed and sealed by Emma T.Mellinger,P.E:',
D. QUALITY ASSURANCE
1.' Miami-Dade Department of Regulatory and Economic Resource'(REX)
:a
E. MATERIAL CERTIFICATIONS
1. None. s
F. STATEMENTS
1. Drawing No.ITS N1090403 and ITS N2090403 statements of code conformance to
2010 FBC issued by Nich ha USA,Inc,dated 03/16/2009signed and sealed by Carl
D.Fussner,P.E.on 07/10/2014. a
2. Statement letter of no financial interest issued by Pr'ogies axve Engineering,Inc.,dated
07/10/2014,signed and sealed by Carl D.Fussner,P.E.
i
i
i
{ i Carlos K Utrera,P.B.
Product Control Examiner
NUA No.14=0715.03
Expiration Date:July 12,2019
Approval Date:January 29,2015
• 1 s.,
-
12"Panels Shown 51/4"Panels:Shown DESCRIPTION'and SPECIFICATION NichiBoard&
EcoPlank lap siding material is a.nori-asbastos fiber cement
2"x Studs product tested In accordance with ASTM 0-1185&ASTM
@ 16"o/c 0-1186 Type A meeting the requirements of the 2010 Florida
(Typ.) Building Code(HVHZ). Planks:are available in.a variety of
widthswithin the maximum and minimum dimensions
specified below.
8"Max.
oIc Spacing
(TyP.) Plank Dimensions
Width Le- nath Thickness
5&Min: 12' 5s°
t2"Max:. IT is"
Desian Pressure Rating. -125 psf
"Max. LIMITATIONS
o/o Spacing 1. All installation.shall be done,in accordance
(Typ;) with this Notice of Acceptance,the
manufacturer's installation recommendations,
and the applicable sections of the 2010
71 4"oIc Spacing Florida Building Code including High Velocity
(TYP) Hurricane Zone where Required,
2. Wood stuft and plywood:sheathing
supporting NichiSoard-and EcoPlank siding
shall confonritO the 2010 Flotida Building
Code.(inciuding.the HVHZVvhere-required).
• and the requirements of this Notice of
- — -----------=----------- Acceptance(See Note Sheet 2).
•-- �.- -
- 3:--Sldirtg-instaliedes.sPeci8ed:heWn�
.shaU-be—
Panel Height ass eas rg MisilImpact
�
(TYP
S
12"Panel Height - _ - = - - - u —w'''G�Q` •C
{TYPO Q*
-- - --- _ + No 71947 •= ��-
--- — 7q IZ,
-
w *=
1�Overlap 1„ 8q ...� � � *, • � - -- --
(pyp) �1 Overlap l►t tali Tr duatCalow
(TYP•) STATE OF
°"a iTS NtOBp403 PMM4
,ax NichiBoard& EcoPlankNICHIHA USA, INC. JUL 1.0 2414
o Fib$r Cement Siding sass E.Johns Crashing,Johns Crock,Ck SMI
Nirc HIrHA- �,a r,�,rdr.ts.x000 �
NICHIBOARD&ECOPLANK SIDING INSTALLATION.
• The planks shall be applied horizontally commencing from the
bottom course of the wall.
• Each successive course shall overlap the prior course by 1 Ya".
• Any vertical joints shall be=over framing members,with
fasteners either side of the joint..
• The.planks shall be installed over%8'APA rated exterior-grade
plywood(SG=0.50 min;).,supported.by 2"x 4"minimum wood
NlchiBoard orEcoPlank Siding studs spaced a maximum of 16",o.c.
weather-Restsanraarrter . The:siding shall be fastened through:over-Zapping planks with
ed x 2 Y"Common Nall Q 8d x 2 Ya"long'common nails over wood'studs.
5 ys"c/o vertically,8-0/c • A row of fasteners shall be:placed.in the overlap of each
Horizontatty. Ye Mtn., course,spaced 8"O/C in the hoeizonteil direction.
21 Mm Edge Distance.'
• Successive rows of fasteners shall be spaced not more than 5
3/"o/c.(Planks greater than.6%"in width shall require an
%"Plywood sheathing additional row of fasteners in the center of the plank).
Fastened to Studs per2010 A distance of between%a"and.2"from the edges shall.always
Florida Building Code be observed.
PLYWOOD SHEATHING NOTE
NichiScard and EcoPlank Fiber-Cement Lap Siding is designed
NichiBoard or EcoPlank to be installed'to plywood sheathing. Such plywood shall be%"
weathei-Rosisant Barrier (5-ply)minimum,APA rated sheathing,Structural 1 grade,with a
ed•x 2YJ'Common Nail @ specified specific gravity of 0.50 or greater(e.g.Douglas .
5.%"o/c Vertically,s'Cie
Horizontally. %'Min., Fir.-Larch or Southern Pine). Use of other grade plywood.shall
2`M=Edge Distance. require a-site-specific fastener design for the siding attachment,
signed and'sealed by-a Florida Registered Professional
-- ------- ------------ ----- - - - ____ �-
RlywppdSheathing— — -- — — --- ----- ---- ---- —--- -- ----- ------- ---- ----------- --
Fastened to Studs per 2010 Such plywood sheathing shall be supported by framing
Florida Building Code
studs,-e_ach -minimum_mum woo suds,or_2"x 6"18ga met
at
COrSrstn of 2"x4"
at� 6o/c-
-
Plywood'shall=be aittached fo-theframin PSV, • - S;SiV� --
y�;a, studs in accordance with the 2010 Florida Building Code(Higlj,%.rj �GE N ,F=F�Q��i
- - -- - - --t-- ----- - -- - -- Veloci - .-- --- - -- -- -- - -- -Z--:-No - -
rKo ,—ZISo * 7-1907—
Velocity-Hunicane-Zone) '
2
�Q
8>Mrmnu !+•rod�c1 t�otdtrsl �0 S I ATE OF.00
RU`
,. ..o0 RA
ma.
���5 ..........- ��..
ffS
Mo�
W2,oso4o9 NichiBoard:& EcoPlank NIC.HIHA USA, INC. JUL 10 2014
Fiber Cement Siding sass E.Johns crossing;Johns Creek,Gi.►.30097
r NICHIH
ceten=tt , Mamh16,2c00 c-o ff,,4:,Q wA 7
1ltier
n. J
�•--48"Pane[Width 48"Panel Width I DESCRIPTION g,mate al is a. TION
on-as
!E NichiPanel siding;materiai isanon-asbestos
fiber cement product.tested in accordance
_ with ASTM.C-1185&ASTM C-1188 Type A
2"xStuds - meeting the requirements'of the 2010
@ 16"o% Florida Building Code(HVHZ). Panels are
�'yp,� available in four-foot widths within the
maximum and minimum dimensions
specified below.
• Plank Dimensions
• . • Width Length Thickness
. 48" B' %s"
6"Max. 48" 10• %e"
o1c Spacing. `
48" 12' s�6"
(Typ•) .
. Design Pressure Rating -104 psf
LIMITATIONS
I All installation shall be done in accordance
With this Notice.of.Acceptance,the
• manufacturer's installation
recommendationsiAnd the-applicable
61,Max, g sections of the 20.10 Florida Building Code
old Spacing Including High Velocity Hurricane Zone
(Typ;) where Required.
• 2: Wood'stud§and plywood sheathing
supporting NichiPanel siding shall conform
. to the 2010 Florida Building Code
(including the HVHZwhere required),and
• the'requirements of this.Notice of
--- _- _ - - -- - - — _ = =- =_::- -= —_ -
Acceptance See Note Sheet 2).- - - -
-= --_--_-__- -- Accep _
• 3. Siding.installed as specified.herein shall be'11%1511118'r"�
• Missile Impact
..
- -- - --- ---- -- - - ----- fit -- �--- -----
classified as Large m a � F ��
-
� a
* 9
- - - - - - --- - - -- -- - - - - - - - A-
-Dim
-
Na No 7 7 L
-- rq
:cc:
. M�iatn ProductCeeead :'A: STATE OF
�/•
OR
AL
o rM
IG NichiPanel NICHIHA USA, INC. JUL 1` 0 2014
c Fiber Cement Siding 6465 E.Johns Crossing,Johns Creety.GAA0097
Hoer cemeat
NICHIHA. ;,,". Wth10..-4o9
NICHIBOARD S:ECOPLANK SIDING INSTALLATION
The planks shall be applied vertically,avoiding horizontal
joints.
The planks shall be installed over e"APA rated
exterior-grade plywood.(SG=0.50 min.)supported by
2"x4"minimum wood studs spaced a maAmum.of 16"o.c.
• Fasteners shall be placed at 6"o/c In the vertical direction
and 6"o/c in thehorizontal direction.
• A distance of between%4"and 3"from the edges shall
always be observed.
NichiPanel Siding
Weather-Resisant-8anier
PLYWOOD SHEATHING-NOTE
6d 2"Common Nail @ NichiPanel Fiber-Cement Siding is designed to be Installed.to
6"o/c VerticaW.6"old
Hodzontaily. %4'Min., plywood sheathing. -Such plywood shall be%"(5-ply)minimum,
3"Max:Edge Distance. APA-rated sheathing,Structural 1 grade,with aspectfied
specific gravity of 0.50 or greater(e.g.Douglas Fir-Larch or
%"Plywood Sheathing Southern Pine). Use of other gradeplywood shall require a
Fastened to Studs per-2010
Fiodda Building code site=specific fastener.design.for the siding.attachment,signed
and sealed by`a Florida Registered Professional Engineer.
Such,plywood.sheeithing shall be.supported by framing.
consisting of 2"-x 4"minimum wood studs,.or 2"x 6 18ga metal
- - -