HomeMy WebLinkAboutDrawing i � s
REPLACE DOOR IN 1 OPENING ONLY.
I a ,
NEW(DOOR TO BE IMPACT RESISTANT—
HURRICANE SHUTTERS NOT REQUIRED.
I '
I
f36 80"
I i
OPENING PRODUCT DEiSIGN I
OPENING SQ. WIND PRESSURES APPROVAL PRESSURESICOMMENTS
NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. I NEG
1 36 80 20.00 4 36.1 1 —39.3 FL22384.1 70.0 —70.6 ? ! FRONT ENTRY—LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. i
i
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWSi"INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL CLIME lNTS.
I .
I
t '
f ,
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES i !
i
MEAN ROOF HEIGHT= 11 FT 1 IN I
� I
VEGA RESIDENCE
I ,
2915 SHERWOOD LANE DOOR lREPLACEMENT PLAN
4
� I
FORT PIERCE, FLORIDA
I