HomeMy WebLinkAboutProduct Approval I
Florida Building Code Online Page 1 of 2
f
KV
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats S Facts Publications FBC Staff 6CIS Site Map Links Search
I
id WIN
Product Approval
t `i.-xUSER:Public User
�``'` I �
Product Approval Menu>Product or ADDlication Search>Application List>Application Detail
>i _ FL FI-10674-1112
Application Type Revision
Code Version 2014
Application Status Approved !
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary;.
l �� I
i Comments
i
Archived
Product Manufacturer Owens Coming
lAddress/Phone/Email One Owens Coming Parkway I
Toledo,OH 43659'
(740)404-7829
jl greg.keeler@owenscorning.corn
Authorized Signature Greg Keeler ! r
greg.keeler@ owenscomi ng.cpm
Technical Representative Mel Sancrant iI
Address/Phone/Email 1 Owens Corning PKWY
Toledo,OH 43659
(419)-376-8360
mel.sancrant@owenscomig.com
I ,
Quality Assurance Representative
Address/Phone/Email
I
Category Roofing
Subcategory Asphalt Shingles
i f
Compliance Method Evaluation Report from a Florida Registered.Architect or a Licensed
Florida Professional Enginee
Evaluation Report-Harii opy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen I
the Evaluation Report
Florida License PE-59166 I I
Quality Assurance Entity UL'LLC
Quality Assurance Contract Expiration Date 05/16/2020
i
Validated'By John W. Knezevich,PE '
t.
Validation Checklist- Hardcopy Received
I I
Certificate of Independence FL10674 R12 COI 2016 01-1 COI Nieminen.pdf
I
Referenced Standard and Year(of Standard) Standard j Year
ASTM D3161 I 2009
ASTM D3462 iI 2009
ASTM D7158 7008
I I
I
Equivalence of Product Standards I
Certified By
i I
I i
Sections from the Code
I i i
http://www.floridabuildin�.org/pr/pr_app_dtl.aspx?param=wGEVXQwt!DgtBNbEY5 V%2b... 8/4/2017
i
Florida Building Code Online Page 2 of 2
I
Product Approval Method Method 1 Option D
I I
Date Submitted 04/18/2016
Date Validated 04/19/2016 'I I
Date Pending FBC Approval 04/20/2016 !
Date Approved 06/08/2016
Summary of Products
1 �
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tabjI laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions,,,
Approved for use in HVHZ:No FL10674 R12 II 2016 041FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R12.Ddf
Impact Resistant:N/A Verified By: Robert 3. M. Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section S. Evaluation Reports
FL10674 R12 AEII2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R12.pdf.
Created by Independent Third Party:Yes
Back Next
I
i I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone!85D-487-1824
The'State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement:;Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response'to a public-uecords request,do notsend
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any(questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here. I
Product Approval
ffAccepts:
Credit Caid
Safe
RN
t 3 �,
" n�
I � I
I
I I
I
i
I
11 I
II I
II '�
I
I.
ii
I
I
�I
I
littp://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDdtBNbEY V%2b... 8/4/2017
li I
V
I
I
I
I �
EXTERIOR RESEARCFI &DESIGN,LLC.
Certificate of Authorization#9503
TRINIT)
g� 353 CHRISTIAN STREET,UNIT#13
ERS" OXFORD,CT 06478
PHONE:(203)262-9245
j FAX:(203)262-9243
EVALUATION REPORT
Owens Corning II Evaluation Report 037940.02.12-R7
j One Owens Corning Parkway i FL10674-R12
Toledo,OH 43659 Date of Issuance:02/06/2012
i� Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5t' Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
1 CONTINUED COMPLIANCE:, This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement too notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes i TrinitylERD!requires a complete
review of this Evaluation Report relative to updated Code requirements with each lCode Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words ``Trinityl,ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall beldone in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8. I�
Prepared by: iati(rtp• --
�,��`'• -"�1`�:' The Facsimile seal;a
Robert J.M.Nieminen,P.E. %,����.::.•••� .4 ppearingwasauthoritedbyRobertNieminen,
P.E.on 04/16/2016.This does'not serve as an electronically signed
Florida Registration NO.59166,Florida DCA ANE1983 document.signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product. it
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, [6 any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for pei-imitting or design'guidance unless retained
specifically for that purpose.
I '
'i I
- I I
ERDTYTRINIROOFING SYSTEMS EVALUATION:
1. SCOPE: '
Product Category: Roofing f
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida'-Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to,the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Propeirty Standard I Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 i 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 I i 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
� I
3. REFERENCES:
Enti Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 ' 04/18/2006
U L LLC(TST9 628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
Y
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic@ and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire"'are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 DurationTruDefinitions Durations, Durations Premium Cool, TryDefinition0 Duration' Designer Color
Collection, TruDefinition'Oakridges, Oakridges and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshires Hip &Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge!Shingle's, ProEdge Hip & Ridge
Shingles and DuraRidgel Hip&Ridge Shingles are fiberglass reinforced,hip and ridgeiasphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are star ier strips for asphalt roof shingles.
5. LIMITATIONS:
' I !
5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, oriprevious versiins thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
i
I '
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
it
Exterior Research and Design,LLC. Evaluati;on Report 037940.02.12-R7
Certificate of Authorization#9503 i FL10674-R12
Revision 7:04/18/2016
I Page 2 of 8
,I I
j .
I
I
TRINFFYERR
j 5_4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasd=150 mph (Val,=194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starte j Strip Plus noted herein are Classified
i in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class f, indicating the shingles are
acceptable for use in all wind zones up to Vasd=150 mph (Vast=194 mph). Refer to Section 6 for installation
requirements to meet this wind rating. j
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
11 1
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit inl accordance with the Florida Building
Code and F.A.C.Rule 61G20-3. j
I I
I '
i6. INSTALLATION: I i
6.1 . Underlayment: l
6.1.1 Underlayment shall be acceptable to Owens Corning and shall holld current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 11507.2.3;,,1507.14 or R905.2.3.
6_2 Asphalt Shingles:
1.
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC SectionsA507.2ior R905.2, with the following
exceptions:
o Berkshire'shingles require minimum five(5)nails per shingle. I
i WeatherGuard'HP shingles require minimum six(6)nails per shingle. '
Devonshire"'shingles require minimum six(6) nails per shingle.
I '
>- Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and Installation limitations.
I
6.2.2 Fasteners shall be in accordance with the manufacturer's published)requirements„but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted. i
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details. j
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: i� {
Felt underlayment Deck Deck "r-adhered
'pr, Felt ucedarfayment I,
Weatherl.ackV
ter•
Sell-adhered ' 2 undedayrnetd
�1WeatherLock- l
underlavment
— `!- Drip edge
Drip Drip edge Drip—
edge
edge
I
Nark located
Wails lactated V-3"nom eave
Y 2'-3"ttum eave S%'/
Install first Self-sealing adhesive >: Sel`.se�ng adhesive
Starter St
Instal fust Starter Strip Plus, •� oiiticned along ease
positioned along ease y / p g
vviilt 6'removed-
shingle wit r l�y
G"removed ti
Starter Strip shkrgle overhangs eaves and rakes',§=?-;' Starr Strip Plus overhangs eaves and rakes ala'-314'
li I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
l Certificate of Authorization#9503 I I FL10674-R12
Revision 7:04/18/2016
Page 3 of 8
, I I
I I
;� I
I
i
I
' i I
I I
TRINFIYERD .
6.2.6 Minimum Nailing—Classic°&Supreme:
D 0 • i � I
Normal Mansard or Area pare (Normal Mansard or Area porn
Wind Areas High Wind desvanes y Wind Areas High Wind desvanos y
Area para vientos normales Areas vientos fuartes Area para vientos normele"s Areaai vientos fuertes
z-� (B t2• 1`� t' (AY II ^,1 T1• IZ"� (B) rZ" 1•-i
x-121 �=1 i v --0z 118"' � I•
5"Exposure 6 5/8"Exposure!)
Expeaicidn Exposition
I I
6.2.7 Minimum Nailing—Berkshire°:
i 1
r I
I
I {
&ealant strip j Sealant strip
/to tirade sd7ada `!a tea Asaffbor
--, ---D o t---3�0 0 0 0 •.-+G-0
B'.
`T,
i
I 8 I
Y I
I I
I
I I
Standard Fastening Pattern 6-Nail Fastening Pattern
0
II I I
I I
I I
I I
&ealam strip
1a:vaoesellador
8 ti4' 8! 8 i." 8 yf i 1,
� r� -
0 6T
2 �
Asphah roofing cement
Cemento de ttc5a d2 asfaho
Mansard or Steep Slope Fastening Pattern q
I ,
I
i I
j
I
i r I
z
'I
I
I I
I r
II
I I I
II I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization tJ9503 i FL10674-RZ2
_ I I
Revision 7:04/18/2016
it I
Page 4of8
i!
, I
I II '
I
: TRINI ERD
I
6.2.8 Minimum Nailing—Devonshire":
I I
I II 'I
' i I
II I
7"
+
Clams I I
Nails
5.518"exposure
' Sealant location "i-�"m" ""• -
. Exposici6n de 5-5/8 pulg Ubfcaci6n del sellador
Ten V Spots of Asphali Roof Cement
Standard 6-Nail Fastening Pattern Mansard 6r Steep Slope Fastening Pattern
I i �
6.2.9 Minimum Nailing—Duration°,TruDefinition° Duration, Duration"' Premium Cool & I ruDefinitionm Duration
Designer Color Collection: l
I i
4-Nail Fastening Pattern it 6-Na11 Fastening Pattern
SureNaiFH tast<ni�uea nMtR I I guraNailEfsstrn{ng area width
!toll.Typical I I Nm47ypWl
1 tr 12" f' t} +x I I 12 r
rt
- .. ' — :---'- �tJa^�s.asmra-i --• ._. IZ •
-a4.
, .
Standard Fastening Pattern 6-Nail Fastening Pattern
rFastening for Slopes Greater Than 27:12
SuretJag?tastanfng srea rrie:a
nul,Typical
b.t/8"
lr, 711 f�.```
Four 1-+pato;dsphattfiaetutg CSR.eat ' I
Mansard or Steep Slope Fastening Patternll {
II '
I ,
r
.I I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117
Certificate of Authorization#9503 I FL10674-R12
Revision 7:04118/2016
Page 5 of 8
I 'I
. I
,I
I I
I
w
li
•
TPUNITY
i
I
I
6.2.1 Minimum Nailing—Tru Definition Oakridge®,Oakridge":
I
4 Nall Pattern 6 Nail Pattern
Esauema con 4 claws Esquema con 6 clavas
' II
12-
5
2•
5518"ExposureNaffs 5518"Exposule Nails
Expasicida de Sig ping. C(avos Exposition de 5518pu1g. 5 5i8"Exposwe arms5 518"Exposura
£xposfcfon de 5 Qg palg. Exposicfd,•r de 56518 pa4g.
I
Standard Fastening Pattern 6I Nail Fastening Pattern
Fastening far Slopes Greaterlban 21:12
r sluermw tnstanme area w Wh
1 Ilan1yp I'M .
r tr• •�_}�._ � , Ir I � l i
6-tib•5.5:5" - .. I '
Fa-I"Spat%of n%Phall Roafln9 Corvert! I f
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard"HP:
I I
Cbm
I
17
Exterior
�;,�•.� i; , �
.•� :•1 F�aiee FPawal Nall&ir
�11bu !
I
I I �
I
Ii
II I
I
II I
I
� I
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7
Certificate of Authorization#9503 FL10674-R12
Revision 7:04/18/2016
Page 6 of 8
I �
,I •
I
I
li I
� I
I ,
I
TRINI
6.3 Hip&Ridge Shingles:
i 6.3.1 Installation of Berkshire}Hip and Ridge Shingles, High Ridge, WeatheGuardo-AHP Hip and Ridge Shingles and
ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published1ristruction5,using four
(4) nails per shingle. Installation of DuraRidgel" Hip & Ridge Shingles)shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer ,to Owens Corning published
information on wind resistance and installation limitations, including the ;use of;hand-sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire°Hip&Ridge and High Ridge:
Fig.1�— Fig.2
lk PrevairmDWnd
Direction �4 \\P�� IIPVrnv ` sideVieu
hails \\� z j nsls nails i
I �
Lmnimlod , r• t
,Piece
I d
1
•_
j
6.3.4 Minimum Nailing—WeatherGuard°HP Hip and Ridge:
Fig-C Hip&Ridge Shingle Fastening
Fig.A 4 TopVLnv
PluJalll(1g V.-Ind�ireclbn i pi
nails -���—A44 tt7 I
'°
71
Exposure � I I I
i
I
I ,
i
I
I
I
I I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-117
j Certificate of Authorization#9503 FL10674-R12
I + I
Revision 7:04/18/2016
Page 7 of 8
I i
t ,
,I
II ;ED
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: I
s
Prevaiiling Standard I 11
Wind Dfrec4ion Fastening
Sealant strip pattflrn
6-Exposure \` ii
12• Sealant
1
� 7 Ye f
_
Fasten 71' I � 6"ErPosura I
Cover Exposed 1
_-� Fastecrers with i i
' Roof Cement.\ �I I 02-11
-
6.3.6 Minimum Nailing—DuraRidger" Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
II I
Preniind Wird Dim:dai �l np Y Ew j
a—DiroaiondcrnirunEadu nc - IVn enplmr
Dirocdtndolvirntoprodrrniranw rtrll zasuperior' i Lrr
ky I_
flail;
Claras-� ,
rYAPT,
ez–•I
sa
li 1
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein. �
7.2' Asphalt shingle wrappers shall indicate compliance with one of the Required,classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS: i
I ,
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product. !!
9. WIANUFACTURING PLANTS:
i
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements. it
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann-@ILI-.com
END OF EVALUATION REPORT-
'I S
I �
� I
I i I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization#950 j Fl-10674-1112
Revision 7:04/1812016
! Page 8 of 8