HomeMy WebLinkAboutOwens Corning Shingle NOAFL #
FL10674-R12
Application Type
Revision
Code Version
2014
Application Status
Approved
05/16/2020
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
John W. Knezevich, PE
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owen5corning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License
PE -59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
05/16/2020
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL10674 R12 COI 2016 01 COI Nieminen odf
Standard
ASTM D3161
ASTM 03462
ASTM D715B
Year
2009
2009
2008
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
of
Method 1 Option D
04/18/2016
04/19/2016
04/20/2016
06/08/2016
10/10/2017
FL # Model, Number or Name I Description
10674.1 Owens Corning Asphalt Roofing
3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge shingles
Shingles and Starters
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other; Refer to ER, Section S.
Installation Instructions
FL10674 R12 II 2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-1112.odf
Verified By: Robert 3. M. Nieminen PE - 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R12.pdf
Created by Independent Third Party: Yes
0 0
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-1824
The Rate of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-recorGs request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to section
455.275(1), Flgrida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S.,
please click here .
Product approval Accept:
' O H
Credit Card
Safe
e
TRINITY. ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Report 037940.02.12-R7
FL10674-1112
Date of Issuance: 02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert 1.M. Nleminen, P.E.
Florida Registration No, 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on W/13/2016. This does nm serve as an electrunically signed
document Signed, sealed ha,dcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
'TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D71SS 2008
3. REFERENCES:
Entity Examination Reference Date
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter 02/13/2014
UL LLC (TST9628) Physical Properties Classification letter 10/02/2015
Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp. 08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles.
4.1.3 Devonshire T" are fiberglass reinforced, S -tab asphalt roof shingles.
4.1.4 Duration , TruDefinition Duration, Duration Premium Cool, TruDefinition' Duration' Designer Color
Collection, TruDefinition Oakridge, Oakridge and WeatherGuard� HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgeT" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
S.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7
Certllftc eo/Authorization #9503 F1.10674.1112
Revision 7:04/18/2016
Page 2 of 8
i
`` ' TRINITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are
acceptable for use in all wind zones up to Va,d = 150 mph (Vu,s = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61620-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard HP shingles require minimum six (6) nails per shingle.
➢ Devonshire'" shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Fet underteyment Deck
SeWadiared
Wsathasloek'
(; urderkgmnn
Drip edge
�9e
Wits lontad
2-r from "Ye
hntell l6etrptpp
SeR.sealinge&wsia,
S"" svitlr
poshimmA alae sere
r removed
Starter Snip shingle crethsatV eaves and takes'A'4,'
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7
certfT.te of tharlratlan#9503 FL10674-R12
Revision 7:04/18/2016
Page 3 of 8
6.2.6 Minimum Nailing— Classic® & Supreme:
Nomul Mansard or Arw ppa
Yt8ro1 Arora. NIah lMad d"wou ss r
Am Mn vion0os nolrna"s Ares viontoo /cartes
s
6.2.7 Minimum Nailing— Berkshire®:
Standard Fastening Pattern
Exterior Research and Design, LLC.
Cortiflrute of Authorization #9$63
TRINITY ERD
Narrow Mansard or A~ pars
WWad Am" leap "nd
A. d..ren.e y
Apen WeMoe nomusW Ansa WIMoe Iwrtss
a � Y t" Y • g) x• P
1
a ua" axpaaara
FrpoaiNdn
6 -Nail Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Evaluation Report 037940.02.12-R7
FLID674-R32
Revision 7: 04/18/2016
Page 4 of
6.2.8 Minimum Nailing—Devonshire':
1- i 7- i $. 8" 8„ 7. i t�
'amu
Mir exposure sww keaRon
&posi fM de 5 4M puk INdaOW del sePador
Standard 6 -Nail Fastening Pattern
4 TRINITY ERo
ss
q.,
Ten t" d k hah Pouf Cement
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinitione Duration, Duration® Premium Cool & Tru Definition Duration'
Designer Color Collection:
"as Fastening Fath rn
AfWYWfsM�a�YaMia0ln
MeO I)ykal
atT sdY
Standard Fastening Pattern
au�aa.ln+eam�9....mn
Mansard or Steep Slope Fastening Pattern
6 -Nail Fastening Pattern
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
GrAi tate ofAuehorbation#9503 FL10674-1132
Revision 7:04/18/2016
Page 5 of 8
6.2.1 Minimum Nailing —TruDefinition�Oakridge°,Oakridge®:
4 Nall Proem
Esquana tta 4 Daws
s 518" Exposvw '
Erpvskm do 66/6puig,
Standard Fastening Pattern
1wrr
"t
J TRINITY' ERa
6Nall Pattern
Fsquana tat 6ckWs
t- r
safe" UpamwCbm 6618" Eepoww
Sgxn cf5n de 66lg pWq. Erymfolbn di 6 &TPW9
miw.asr.wwnov..vaa
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing— WeatherGuarde HP:
N-- 1 —
•l �r�ti'r
Exterior Research and Design, U.C.
CerNffmte of AuthorktOlon x9503
6 -Nail Fastening Pattern
/IwOM YJa view
Yih IMrd
69Jwr. �lei�i�dr
Evaluation Report 037940.02.12-R7
F1.10674 -R12
Revision 7: 04/18/2016
Page 6 of 8
TRINITY ERo
6_3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuarda HP Hip and Ridge Shingles and
ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of Dura Ridge'" Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing— Berkshire® Hip & Ridge and High Ridge:
Fig. 1 4
`.
CifetlYP �\\�
YeYn � v\\ `\ p
Fig. 2
1oP'<eX SYeNr
t W,L Y�1�
�1
i YI
333e1
I
6.3.4 Minimum Nailing — WeatherGuarde HP Hip and Ridge:
Fig. A v v
PXXw WM
~Gnctya / A.
A
w1Y `
A
\�1 A
1 1
�10�W�a N
Exterior Research and Design, LLC.
Certificate ofAuthonzatlan #9503
Fig. C Hip
.& Ridge Shingle Fastening
TOPYYw
' XNY Wlla
R� R
S' E@aaxc
�
III
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7:04/18/2016
Page 7 of 9
6.3.5 Minimum Nailing - Pro Edge Hip & Ridge Shingles:
Pmvaiing
YAW Diroction BeYant>
W
\�J TRINITY ERD
6.3.6 Minimum Nailing — Dura Ridge" Hip & Ridge Shingles:
Nate: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
*— o .aldvr�il d�r.n
Dinoim dd arro pdanianu
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann(&ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
CertUlmte ofAlWhorlratlon 49503 FL30674-1132
Revision 7: 04/18/2016
Page 8 of 8