HomeMy WebLinkAboutBuilding Permit Application i
I
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: Permit Number:
�II
r
Building Permit Application
Planning and Development Services I
Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential
PERMIT APPLICATION FOR: Roof
I,
I _
PROPOSED Ii' OROVEME.NT'LO.CATION;., .
14342 Isla Flores Ave, Fort Pierce FL 34951 I
' Address: � it I
Legal Description: Spanish Lakes Fairways SECT 6&7 TWP 34 RANGE 39
Property Tax ID#: 1306-111-0001-000-0 I Lot No.
Site Plan Name: Block No.
i
Project Name: I'
Setbacks Front Back: Right Side: Left Sider I
I I
`DETAILED DESCRIPTION OF.WORK
fkl i
Reroof- Remove existing roof covering, dry in with self adhering underlaynient and install new asphalt
shingles.
I.
o)9 bywl,L
CONSTRUCTION INFOR IVIATIDN
Additional work to be ne orme un er this permit—check aappy:
I HVAC El Gas Tank ❑Gas Piping _Shutters Windows/Doors
El
ElElectric ❑Plumbing Sprinklers Generator Roof 3 f Z Roof pitch
Total Sq. Ft of Construction: 1540 S . Ft.of First Floors
i
,Cost of Construction:$ 7,080 Utilities: _Sewer FISiptic Building Height:
I�
,.OW-NER/L'ESSEE. . CONTRACTOR I4
..
Name Wynne Building Corp&Robert Beaverson Name: Michael Miller
;Address:12804 SW 122nd Ave Company: Trade Winds Roofing, Inc
'City: Miami State:FL Address: P.O. Boxii13208 i'
Zip Code: 33186 Fax: City: Fort Pierce j State:FL
Phone No.231-250-2420 Zip Code: 34979 Fax: 772-466-9725
E-Mail: Phone No. 772-466-9420 '1
Fill in fee simple Title Holder on next page(if different E-Mail: Mike@trad,ewindsroofing.com
,from the owner listed above) State or County License: CC C057399
i
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required.
.i
SUPPLEMENTAL:CONSTRUCTION LIEN LAW,lNFORMATION
t
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY:! _Not Applicable
Name: Name:
Address: Address:
City: State: City: 1 State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: Not Applicable BONDING COMPANY: _Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone: 1
I L'
OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit. I j
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenantslthat may restrict or prohibit such
'structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room'additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
I�
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first inspectioxx�. If you intend to obtain financing,consult with fender or an attorney before
commencin w k or r c6r our Notice of Commencement.
I
Signature of Owner/Lessee/Contractor as A ent for Owner Signature of Contractor/License Holder
STATE OF FLORIDA STATE OF FLORID
COUNTY OF �,� COUNTY OF �
i I
The f rgoing i ment was acknowledg d before me The for oing instrument wash ac ow ledged before me
this1 day of ( _e In JD (,20�by this�day of � P IrYI/ a/20by
C' ,In,(A)�y. ISI l AA ccs
Name of person ing statement Name of personlnaking statement
Personally Known OR Produced Identification Personally Known OR Produced Identification
Type of Identification Type of Identification j
Pr duced A Prod ced l
N � c
I ,
(Signature of Notary P likIeSi: 96 (Signature of Notary Publ c—Stat of Florida
� a)Lyne Wilkin elicia L e Wilkin
R �S y,n
Commission No. NQ PUBLIC �RYPUBLIC
���t Commission No. I ! �I
S ATE F FLORIDA OF FLORIDA
Comm#GG103860 Comm#GG103860'Pwnirao 1
I j
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION I, SEATURTLE MANGROVE
i COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE I j
RECEIVED
DATE
COMPLETED
Rev.8/2/17
I '
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
353 CHRISTIAN STREET, UNIT#13
! •RIMY ER OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Soprema, Inca Evaluation Report 518010.06.09-R10
1640 rue Haggerty I, ! FL2569-R12
Drummondville,Qu6becJ2C5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 10:06/12/2017
SCOPE: I
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
!
construction materials in the State of Florida. The documentation submitted hasi been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Builtling Code, Residential.Volume. She
!
products described herein have been evaluated for compliance with the 5th Edition (2014)!Florida Building Code
sections noted herein. !
DESCRIPTION: Soprema Roof Underlayments
LABELING:' Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
li herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prodl.ct(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
fADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitVI ERD Evaluated" may be displayed in
f advertising literature. if any portion of the Evaluation Report is displayed,then itlshalt be,done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
i its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
I' I
Prepared by: !
'
Robert J.M.Nieminen P.E. 4' = The facsimile se al'appearing%vas authorized by RobertPliemmen,
P.E.on orvi2/2617.This does not serve as an electronically signed
do11
Florida Re istration No.59166,Florida DCA
} CJ ment.Signed,sealed hardcopies have been transmittedto the
. - Product Approve!,Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitvlERD does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or
! distributing products it evaluates.
' 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing p oducts it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which'the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
i
S. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof,is/was used for permittinglo,r design guidance unless retained
specifically for that purpose.
I, I
y i
I
i
I
TRI .CITY
'ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE: I
i
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, haN e demonstrated compliance with the
following sections of the Florida Building Code through testing in acco dance �nrith the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of!Use sets forth herein.
2. STANDARDS: I"
Section Property Standard I Year
1504.3.1 Wind Resistance FM 4474 2004
1504.3.1 Wind Uplift UL 1897 2004
1507.2.4,1507.2.8, Physical Properties ASTM D1970 I' 2009
1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 I 2000
j 1507.11.2 Physical Properties ASTM D6164 I 2005
1523.6.5.2.1 Physical Properties TAS 103 1 1995
TAS 110 Accelerated Weathering TAS 110 2000
1507.3.3 Installation Practice FRSA/TRI April 20121('04-12) 2012
3. REFERENCES:
9
Entity Examination Reference! Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05;04-2 I 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05=R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 I 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190.02109-R1 04/01/2010
1 ERD(TST6049) ASTM D1970/TAS 110 531370.03110-1-R'1 I 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.051!0-R1 09/09/2010
ERD(TST6049) Physical Properties[Tensile Adhesion 511150,05109-R2 10/05/2010
ERD(TST6049) ASTM D1970 S37210.11�11 11/09/2011
ERD(TST6049) ASTM D1970 540540.0213-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile AdhesionS43530.02i14-1 ;; 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 I ! 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 �I I 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01 I, 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 401 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. I PRODUCT DESCRIPTION:
I�
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS!modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene s rfaced, "SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced,SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,LLC, Evaluation Report S18010.06.09-1110
j Certificate of Authorization 519503 FBC NON-HVHZ EVALUATION FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
1 Page 2 of 7
i
' I I
l
I
j � I
I� I
INI , ;E .D
I I
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment. '
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available In two widths;36 and 45 inch. I'
!
! 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene sur aced, high temperature, SBS modified
bitumen roof underlayment. I'
4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sandisurfaced, SBS modified
bitumen roof underlayment. ` I
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-Iurfaced, SBS modified bitumen
roof underlayment. I
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand surfaced', SBS modified bitumen roof
underlayment,with a 36-inch sheet width.
I' I
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat{reinforced,sand-surfaced,SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
I
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand surfaced; SBS modified bitumen roof
underlayment,with a 44-inch sheet width. I
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS!modified bitumen roof
underlayment. i
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, PE. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose-.
5.2 This Evaluation Report is not for use in the HVHZ. I'
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
I
5.4 Soprema Roof Underlayments may be used with any prepared roof)cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be:made.to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering. L,
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE'1. ROOF COVER;OPTIONS
1 Underla ment Asphalt Nail-On Foam-On I; Wood Shakes&
y Shingles Tile Tile I Metal i Shingles Slate
LastobondTU HT Yes Yes Yes Yes Yes Yes
See
Lastobond Shield/Pro HT-N/
RESISTO SA SMOOTH PLY 40 Yes No No No Yes Yes
Lastobond Shield HT/Pro HT-S Yes No No j Yes Yes Yes
Lastobond Eaves Protection Yes No No j No Yes Yes
Sheet/Lastobond 195 I
Exterior Research and Design,LLC. Evaluation Report518010.06.09-R10
Certificate ofAuthorizotion#9503 FBC NON-HVHZ EVALUATION FL2569-1112
Soprema,Inc. i Revision 10:06/12/2017
Page 3 of 7
i
i
I
� I i
' I
.1
--RINITY ERD
TABLE.1 -ROOFFCOVER•OPTIONSII i, I
Asphalt Nail-On Foam-On Wood Shakes&
Underlayment Shingles Tile Tile MI Ral ' Shingles Slate
Lastobond ECO /RESISTO i
LB1236,Grip-Rite Eave&Valley Yes No . NoNo ( Yes Yes
Protector/RESISTO LB1244 I,
Lastobond Smooth Seal HT Yes No No I Yes Yes Yes
Colphene FR GR Yes Yes Yes I No Yes Yes
See 5.5.1
I i
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless(tensile adhesiop/long term aging data
from an accredited testing laboratory is provided.
' Underlayment Adhesive(s)
Lastobond TU HT ICP Adhesives"Polyset AH-160"(FL6332);Dow Chemical"TileBond""Roof Tile Adhesive"(FL717)
Colphene FR GR lCP Adhesives"Polyset AH-160"(FL6332) II; I
5.6 Allowable substrates are noted below:
I
5.6.1 Direct-Bond to Deck:
i
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond ,195, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal.HT applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete. I
Colphene FR GR applied to:
Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
' I
f Note:
Y While not required over plywood, OSB or Southern Yellow (line substrates; Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover Is not slated for installation within
24 hours.
j > Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering Underlayment.
j5.6.2 Bond-to-Insulation:
r Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY i�0, Lasto,bond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond ;195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR
applied to: i I
> Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. j
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
1
Exterior Research and Design,LLC. II I ,Evaluation Report 518010.06.09-1110
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
Page 4 of 7
1 i
I
I i
I
i
i
T TYRINI
;ESD
5.6.3 Bond to Mechanically Attached Base Laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 7.95, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
i ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. !
For installations under mechanically attached prepared roof cove rings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12),! j
5.6.4 Wind Resistance for UnderlaVment Systems in Foam-On Tile Applications' FRSA%TRI April 2012 (04-12)
does not address wind uplift resistance of.all underlayment systems beneath foam-on tile systems, where
the underlayment forms part of the load-path. The following wind 1 plift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foram-on the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to i1 margin of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012(04-12)or FBCi 1609 fogy determination of design wind
pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction. `: f
Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction. i
j Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Havingilurisdiction. j
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust'and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
i splinters and wood projections shall be removed/sanded.;
j Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,' self-adhered, shall be tholioughlyi roll us'ing hand roller and/or
weighted roller to ensure there are no voids, and ensurE!,there fare no voids/bridging at
side and end-laps.
5.6.4.4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps andj6-inch o.c. in three (3),
equally spaced rows in the center of the sheet. !
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered I
I; I
i I
Exterior Research and Design,LLC. Evalua lion Report 518010.06.09-R10
Certificate of Authorization 49503 FBC NON-HVHZ EVALUATION FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
Page 5 of 7
t
I I;
I I
I
TRINFrY ERD
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shalli not be left exposed for longer than 30-
days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY i140' Last obond;Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Sbprema published installation
11 requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail eads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol
j 600c or RESISTO EXTERIOR PRIMER (if applicable),
6.3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOTH PLY 40,Lastobond Shield
HT, Lastobond Pro HT-S, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970�,underli yment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation)within i24 hou S.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed partto the substrate and unroll the remaining,membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve a bond,
I
Horizontal seams should be minimum 3-inches,•configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the(course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back nailing iii the overlap area at the top of
'the sheet at 12-inch O.C.
i
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the'arelease paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and',work upward.
6:3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual,and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
I i
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-1110
Certificate of Authorization ti9503 FBC NON-HVHZ EVALUATION FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
Page 6 of 7
i
' a
I� ,
i I
!
I' IAINITYIERD
6.3.3.1 Lastobond TU HT has met the tile slippage test requirements specified in FRSA/TRI April 2012(04-12) up
to a 10-tile stack to a maximum roof pitch of 6:12 for flat tiles and 512 for lugged tiles. Lugged tiles staged
at pitch>5:12 may use alternate staging method (bottom 2-tile stack shall be inverted,followed by 8 tiles
high on slope,as shown below) it
4 "
i I i
L.
G.
Figure 1: Alternate Staging Method f� i
i
Alternatively, at roof slopes greater than these limitations, all tileslshall be loaded onto a nominal 1"x 2"
horizontal batten to prevent slippage or damage to the underlayment
6.3.3.2 Colphene FR GR has met the tile slippage test requirements specified in FiSA/TRI jApril 2012(04-12)up to
a 10-tile stack to a maximum roof pitch of 5:12 for flat tiles and 6:112 for lugged tiles. At roof slopes greater
than these limitations, all tiles shall be loaded onto a nominal 1"x 2" horizontal batten to prevent slippage
or damage to the underlayment.
I
f 7. BUILDING PERMIT REQUIREMENTS: I,
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
tHis product.
i 8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on ilants covered under Rule 61G20-3 QA
{ requirements.
I 9. QUALITY ASSURANCE ENTITY: !
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com I'a
I
j -END OF EVALUATION REPORT-
I
i
i
Exterior Research and Design,LLC. I Evaluation Report S18010.06.09-1110
i Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-R12
Soprema,Inc. I' Revision 10:06/12/2017
i
Page 7 of 7
i