Loading...
HomeMy WebLinkAboutBuilding Permit Application i I ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: �II r Building Permit Application Planning and Development Services I Building and Code Regulation Division 2300 Virginia Avenue,Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential PERMIT APPLICATION FOR: Roof I, I _ PROPOSED Ii' OROVEME.NT'LO.CATION;., . 14342 Isla Flores Ave, Fort Pierce FL 34951 I ' Address: � it I Legal Description: Spanish Lakes Fairways SECT 6&7 TWP 34 RANGE 39 Property Tax ID#: 1306-111-0001-000-0 I Lot No. Site Plan Name: Block No. i Project Name: I' Setbacks Front Back: Right Side: Left Sider I I I `DETAILED DESCRIPTION OF.WORK fkl i Reroof- Remove existing roof covering, dry in with self adhering underlaynient and install new asphalt shingles. I. o)9 bywl,L CONSTRUCTION INFOR IVIATIDN Additional work to be ne orme un er this permit—check aappy: I HVAC El Gas Tank ❑Gas Piping _Shutters Windows/Doors El ElElectric ❑Plumbing Sprinklers Generator Roof 3 f Z Roof pitch Total Sq. Ft of Construction: 1540 S . Ft.of First Floors i ,Cost of Construction:$ 7,080 Utilities: _Sewer FISiptic Building Height: I� ,.OW-NER/L'ESSEE. . CONTRACTOR I4 .. Name Wynne Building Corp&Robert Beaverson Name: Michael Miller ;Address:12804 SW 122nd Ave Company: Trade Winds Roofing, Inc 'City: Miami State:FL Address: P.O. Boxii13208 i' Zip Code: 33186 Fax: City: Fort Pierce j State:FL Phone No.231-250-2420 Zip Code: 34979 Fax: 772-466-9725 E-Mail: Phone No. 772-466-9420 '1 Fill in fee simple Title Holder on next page(if different E-Mail: Mike@trad,ewindsroofing.com ,from the owner listed above) State or County License: CC C057399 i If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. .i SUPPLEMENTAL:CONSTRUCTION LIEN LAW,lNFORMATION t DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY:! _Not Applicable Name: Name: Address: Address: City: State: City: 1 State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: 1 I L' OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. I j St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenantslthat may restrict or prohibit such 'structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit,I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room'additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use I� WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite before the first inspectioxx�. If you intend to obtain financing,consult with fender or an attorney before commencin w k or r c6r our Notice of Commencement. I Signature of Owner/Lessee/Contractor as A ent for Owner Signature of Contractor/License Holder STATE OF FLORIDA STATE OF FLORID COUNTY OF �,� COUNTY OF � i I The f rgoing i ment was acknowledg d before me The for oing instrument wash ac ow ledged before me this1 day of ( _e In JD (,20�by this�day of � P IrYI/ a/20by C' ,In,(A)�y. ISI l AA ccs Name of person ing statement Name of personlnaking statement Personally Known OR Produced Identification Personally Known OR Produced Identification Type of Identification Type of Identification j Pr duced A Prod ced l N � c I , (Signature of Notary P likIeSi: 96 (Signature of Notary Publ c—Stat of Florida � a)Lyne Wilkin elicia L e Wilkin R �S y,n Commission No. NQ PUBLIC �RYPUBLIC ���t Commission No. I ! �I S ATE F FLORIDA OF FLORIDA Comm#GG103860 Comm#GG103860'Pwnirao 1 I j REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION I, SEATURTLE MANGROVE i COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE I j RECEIVED DATE COMPLETED Rev.8/2/17 I ' EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET, UNIT#13 ! •RIMY ER OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Soprema, Inca Evaluation Report 518010.06.09-R10 1640 rue Haggerty I, ! FL2569-R12 Drummondville,Qu6becJ2C5P8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 10:06/12/2017 SCOPE: I This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of ! construction materials in the State of Florida. The documentation submitted hasi been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Builtling Code, Residential.Volume. She ! products described herein have been evaluated for compliance with the 5th Edition (2014)!Florida Building Code sections noted herein. ! DESCRIPTION: Soprema Roof Underlayments LABELING:' Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted li herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prodl.ct(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. fADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitVI ERD Evaluated" may be displayed in f advertising literature. if any portion of the Evaluation Report is displayed,then itlshalt be,done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or i its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. I' I Prepared by: ! ' Robert J.M.Nieminen P.E. 4' = The facsimile se al'appearing%vas authorized by RobertPliemmen, P.E.on orvi2/2617.This does not serve as an electronically signed do11 Florida Re istration No.59166,Florida DCA } CJ ment.Signed,sealed hardcopies have been transmittedto the . - Product Approve!,Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitvlERD does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or ! distributing products it evaluates. ' 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing p oducts it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which'the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. i S. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof,is/was used for permittinglo,r design guidance unless retained specifically for that purpose. I, I y i I i I TRI .CITY 'ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: I i Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, haN e demonstrated compliance with the following sections of the Florida Building Code through testing in acco dance �nrith the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of!Use sets forth herein. 2. STANDARDS: I" Section Property Standard I Year 1504.3.1 Wind Resistance FM 4474 2004 1504.3.1 Wind Uplift UL 1897 2004 1507.2.4,1507.2.8, Physical Properties ASTM D1970 I' 2009 1507.2.9.2,1507.4.5.1, 1507.5.3,1507.7.3 1507.11.2 Physical Properties ASTM D6163 I 2000 j 1507.11.2 Physical Properties ASTM D6164 I 2005 1523.6.5.2.1 Physical Properties TAS 103 1 1995 TAS 110 Accelerated Weathering TAS 110 2000 1507.3.3 Installation Practice FRSA/TRI April 20121('04-12) 2012 3. REFERENCES: 9 Entity Examination Reference! Date ERD(TST6049) ASTM D1970/TAS 110 2968.05;04-2 I 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05=R1 04/18/2007 ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 I 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 S13190.02109-R1 04/01/2010 1 ERD(TST6049) ASTM D1970/TAS 110 531370.03110-1-R'1 I 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.051!0-R1 09/09/2010 ERD(TST6049) Physical Properties[Tensile Adhesion 511150,05109-R2 10/05/2010 ERD(TST6049) ASTM D1970 S37210.11�11 11/09/2011 ERD(TST6049) ASTM D1970 540540.0213-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile AdhesionS43530.02i14-1 ;; 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 I ! 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 �I I 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 I, 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 401 05/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. I PRODUCT DESCRIPTION: I� 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS!modified bitumen roof underlayment. 4.2 Lastobond Shield is a self-adhering, woven polyethylene s rfaced, "SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced,SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls. Exterior Research and Design,LLC, Evaluation Report S18010.06.09-1110 j Certificate of Authorization 519503 FBC NON-HVHZ EVALUATION FL2569-1112 Soprema,Inc. Revision 10:06/12/2017 1 Page 2 of 7 i ' I I l I j � I I� I INI , ;E .D I I 4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. ' 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available In two widths;36 and 45 inch. I' ! ! 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene sur aced, high temperature, SBS modified bitumen roof underlayment. I' 4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment. 4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sandisurfaced, SBS modified bitumen roof underlayment. ` I 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment. 4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-Iurfaced, SBS modified bitumen roof underlayment. I 4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand surfaced', SBS modified bitumen roof underlayment,with a 36-inch sheet width. I' I 4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat{reinforced,sand-surfaced,SBS modified bitumen roof underlayment,with a 36-inch sheet width. I 4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand surfaced; SBS modified bitumen roof underlayment,with a 44-inch sheet width. I 4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS!modified bitumen roof underlayment. i 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, PE. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose-. 5.2 This Evaluation Report is not for use in the HVHZ. I' 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. I 5.4 Soprema Roof Underlayments may be used with any prepared roof)cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be:made.to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. L, 5.5 Allowable roof covers applied atop the underlayments are follows: TABLE'1. ROOF COVER;OPTIONS 1 Underla ment Asphalt Nail-On Foam-On I; Wood Shakes& y Shingles Tile Tile I Metal i Shingles Slate LastobondTU HT Yes Yes Yes Yes Yes Yes See Lastobond Shield/Pro HT-N/ RESISTO SA SMOOTH PLY 40 Yes No No No Yes Yes Lastobond Shield HT/Pro HT-S Yes No No j Yes Yes Yes Lastobond Eaves Protection Yes No No j No Yes Yes Sheet/Lastobond 195 I Exterior Research and Design,LLC. Evaluation Report518010.06.09-R10 Certificate ofAuthorizotion#9503 FBC NON-HVHZ EVALUATION FL2569-1112 Soprema,Inc. i Revision 10:06/12/2017 Page 3 of 7 i i I � I i ' I .1 --RINITY ERD TABLE.1 -ROOFFCOVER•OPTIONSII i, I Asphalt Nail-On Foam-On Wood Shakes& Underlayment Shingles Tile Tile MI Ral ' Shingles Slate Lastobond ECO /RESISTO i LB1236,Grip-Rite Eave&Valley Yes No . NoNo ( Yes Yes Protector/RESISTO LB1244 I, Lastobond Smooth Seal HT Yes No No I Yes Yes Yes Colphene FR GR Yes Yes Yes I No Yes Yes See 5.5.1 I i 5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless(tensile adhesiop/long term aging data from an accredited testing laboratory is provided. ' Underlayment Adhesive(s) Lastobond TU HT ICP Adhesives"Polyset AH-160"(FL6332);Dow Chemical"TileBond""Roof Tile Adhesive"(FL717) Colphene FR GR lCP Adhesives"Polyset AH-160"(FL6332) II; I 5.6 Allowable substrates are noted below: I 5.6.1 Direct-Bond to Deck: i Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond ,195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal.HT applied to: ➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. I Colphene FR GR applied to: Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. ' I f Note: Y While not required over plywood, OSB or Southern Yellow (line substrates; Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover Is not slated for installation within 24 hours. j > Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering Underlayment. j5.6.2 Bond-to-Insulation: r Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY i�0, Lasto,bond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond ;195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR applied to: i I > Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. j For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. 1 Exterior Research and Design,LLC. II I ,Evaluation Report 518010.06.09-1110 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-1112 Soprema,Inc. Revision 10:06/12/2017 Page 4 of 7 1 i I I i I i i T TYRINI ;ESD 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 7.95, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: i ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. ! For installations under mechanically attached prepared roof cove rings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12),! j 5.6.4 Wind Resistance for UnderlaVment Systems in Foam-On Tile Applications' FRSA%TRI April 2012 (04-12) does not address wind uplift resistance of.all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind 1 plift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foram-on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to i1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBCi 1609 fogy determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. `: f Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. i j Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Havingilurisdiction. j Deck Preparation: Plywood shall be thoroughly cleaned to remove dust'and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp i splinters and wood projections shall be removed/sanded.; j Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT,' self-adhered, shall be tholioughlyi roll us'ing hand roller and/or weighted roller to ensure there are no voids, and ensurE!,there fare no voids/bridging at side and end-laps. 5.6.4.4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps andj6-inch o.c. in three (3), equally spaced rows in the center of the sheet. ! Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered I I; I i I Exterior Research and Design,LLC. Evalua lion Report 518010.06.09-R10 Certificate of Authorization 49503 FBC NON-HVHZ EVALUATION FL2569-1112 Soprema,Inc. Revision 10:06/12/2017 Page 5 of 7 t I I; I I I TRINFrY ERD 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shalli not be left exposed for longer than 30- days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY i140' Last obond;Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Sbprema published installation 11 requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail eads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol j 600c or RESISTO EXTERIOR PRIMER (if applicable), 6.3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970�,underli yment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation)within i24 hou S. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed partto the substrate and unroll the remaining,membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond, I Horizontal seams should be minimum 3-inches,•configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the(course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back nailing iii the overlap area at the top of 'the sheet at 12-inch O.C. i For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the'arelease paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and',work upward. 6:3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual,and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. I i Exterior Research and Design,LLC. Evaluation Report 518010.06.09-1110 Certificate of Authorization ti9503 FBC NON-HVHZ EVALUATION FL2569-1112 Soprema,Inc. Revision 10:06/12/2017 Page 6 of 7 i ' a I� , i I ! I' IAINITYIERD 6.3.3.1 Lastobond TU HT has met the tile slippage test requirements specified in FRSA/TRI April 2012(04-12) up to a 10-tile stack to a maximum roof pitch of 6:12 for flat tiles and 512 for lugged tiles. Lugged tiles staged at pitch>5:12 may use alternate staging method (bottom 2-tile stack shall be inverted,followed by 8 tiles high on slope,as shown below) it 4 " i I i L. G. Figure 1: Alternate Staging Method f� i i Alternatively, at roof slopes greater than these limitations, all tileslshall be loaded onto a nominal 1"x 2" horizontal batten to prevent slippage or damage to the underlayment 6.3.3.2 Colphene FR GR has met the tile slippage test requirements specified in FiSA/TRI jApril 2012(04-12)up to a 10-tile stack to a maximum roof pitch of 5:12 for flat tiles and 6:112 for lugged tiles. At roof slopes greater than these limitations, all tiles shall be loaded onto a nominal 1"x 2" horizontal batten to prevent slippage or damage to the underlayment. I f 7. BUILDING PERMIT REQUIREMENTS: I, As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of tHis product. i 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on ilants covered under Rule 61G20-3 QA { requirements. I 9. QUALITY ASSURANCE ENTITY: ! UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com I'a I j -END OF EVALUATION REPORT- I i i Exterior Research and Design,LLC. I Evaluation Report S18010.06.09-1110 i Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-R12 Soprema,Inc. I' Revision 10:06/12/2017 i Page 7 of 7 i