HomeMy WebLinkAboutBuilding Permit Application II
I I
I
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED,
Date: Permit Number:
Building Permit Application
'Planning and Development Services I�
,Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982 �I
Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential
PERMIT APPLICATION FOR:
Roof II
I,ROPOSED.IMPROVE MENT LOCATION,
Address: 80 Ipanema Way, Fort Pierce, FL 34951
I I
Legal Description: Spanish Lakes Country Club,SECT 6 TWP 345 Range 39E II
I� I
Property Tax ID#: 1301-111-0001-000-5 I� Lot No.
Site Plan Name: Block No.
Project Name:
Setbacks Front Back: Right Side: Left Side-.11
DETAILED DESCRIPTION'OF WORK ' .
„.
Reroof- Remove existing roof covering, dry in with self adhering underlayment and install new asphalt
shingles. l
CONSTRUCTION INFORMATION
Additional work to be Pertormed under this permit—check all appy: I!
HVAC Gas Tank ❑Gas Piping Shutters !I Windows/Doors
Electric ❑_Plumbing Sprinklers ElGenerator Roof Roof pitch
Total Sq. Ft of Construction: 1512 S . Ft.o
6,590 f First Floor;
Cost of Construction:$ Utilities: Sewer Septic F Building Height:
,I
:OWNER%LESSEE . CONTRACTOR;!;
Name Wynne Building Corp&Al Martin Name: Michael Miller
Address:12804 SW 122nd Ave Company: Trade Winds Roofing, Inc
City: Miami State:FL Address: P.O. Box''13208 'y
Zip Code: 33186 Fax: City: Fort Pierce I State:FL
Phone No.508-736-2300 Zip Code: 34979 I; Fax. 772-466-9725
E-Mail: Phone No. 772-466-9420 .'
Fill in fee simple Title Holder on next page(if different E-Mail: Mike@tradewindsroofing.com
from the Owner listed above) State or County License: CC C057399
I
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. ;
l
I
l
i
i
I I '
SUPPLEMENTAL._CONSTRUCTION'LI'EN LAW;INF.ORMATfON , f
DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: Not Applicable
Name: Name:
Address: Address:
City: State:, City: State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
'Zip: Phone: Zip: Plione:
' LI
OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the,work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will, in alll respects, perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency, review:,room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first insRection. If you intend to obtain financing, consult with lender or an attorney before
commencing or r recoFding your Notice of Commencement.
I,
Signature ot Owner/Lessee ontractor as Agent for Owner Signature of Contractor/License Holder
STATE OF FLORIDA � STATE OF FLORIDIA�� � ��
COUNTY OF (1 COUNTY OF
The for oing instrument was a jknowledged before me The forgoing i'nstrum'ent was;ac nowledg before me
this day of C VYl�?A Y.20_0by this day of��/r 2d by
_ M � chaj (
Name of person m king statement Name of person making statement
Personally Known OR Produced Identification Personally Known I�,-�OR Produced Identification
Type of Identification Type of Identification
Produced Produced
(Sign ture of Notary Publ -St of Florida) (Signature of Notary'Public-Sta fi Florida)
Felicia Lyne Wilkin
qFR �So y I; p Felicia Lyn ,Wilkin
Commission No. e NOT gUBLIC Commission No. s�NOTALO ELIC
a —STATE OF FLORIDA '+STATE OF FLORIDr�
g Comm#GG103860 i. ,Comm#GG103860'
s o
i' 1D Eacpires 9;'4/2021
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
Rev.8/2/17
,i
,
� li
' TI `ERD
ROOFING COMPONENT EVALUATION:
� i I
1. SCOPE:
Product Category: Roofing 1
Sub-Category: Underlayment 4
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance 'with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of!Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1504.3.1 Wind Uplift UL 1897 2004
1507.2.4,1507.2.8, Physical Properties ASTM D197,0 i 2009
j1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 0. 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103I 1995
TAS 110 Accelerated Weathering TAS 110 i.'If 2000
1507.3.3 Installation Practice FRSA/TRI April 2012('04-12) 2012
i3. REFERENCES: i
Entity Examination Reference Date
ERD(TST6049) ASTM D 19 70/TAS 110 2968.05.042 ; ! 05/14/2004
ERD(TST6049) Physical Properties 2757-02.05' 02/03/2005
ERD(TST6049) ASTM D 19 70/TAS 110 2974.03.05-2 !,, 05/17/2005
ERD(TST6049) Wind Resistance 27 780705 ) I 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.051-R1 I I 04/18/2007
ERD(TST6049) TAS 103/TAS 110 S7120.11.0�7- 2 q 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 S13190 02109-RI 'i 04/01/2010
I ERD(TST6049) ASTM D1970/TAS 110 S31370.031j10-1-R1; 04/07/2010
II
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05!110-R1 ! 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S111S0.051.09-R2 j', 10/05/2010
j ERD(TST6049) ASTM D1970 S37210.111111 `, 11/09/2011
ERD(TST6049) ASTM D1970 540540.0243-1 I,' 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02I:�14-1 ; 02/21/2014
{ ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 i 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 i;I :1 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.1._R1 j 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 f. 09/24/2015
{ ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 j 03/01/2017
I PRI(TST5878) Physical Properties SOP-064-012-01 ;; 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40. 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation, Exp.10/16/2017
4. PRODUCT DESCRIPTION: =I
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS'Imodified bitumen,roof
underlayment. p
p I 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced,j;SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
1i
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethyleii a surfaced,SIDS modified bitumen roof
! underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,LLC. it ?EvaluatiLon Report 518010.06.09-R10
Certifrrnte of Authorization#9503 FBC NON-HVHZ EVAWATION FL2569-1112
Soprema,Inc. it Revision 10:06/12/2017
Page 2of7
1
,i
r � .-
I'l PUNRY;ER
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment,
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene urfaced; SBS modified bitumen 'roof
underlayment available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.7. Lastobond 195 is a self-adhering, I
glass-mat reinforced sand-surfaced;,; SBS modified bitumen roof
underlayment.
4.8 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforce; sand�'surfaced, SBS modified
bitumen roof underlayment.
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-' rfaced,l SBS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced; SBS modified bitumen
roof underlayment.
{ 4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand Isurfaced!!
l
;
TABLE 1::ROOF.COVER OPTIONS,�. J,
Asphalt Nail-On Foam-On Wood Shakes&
Underlayment Metal I Slate
Shingles Tile Tile Shingles
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes No No No Yes Yes
Protector/RESISTO LB1244 I'r
Lastobond Smooth Seal HT Yes No No j Yes ;i Yes Yes
Yes
Colphene FR GR Yes Yes See 55.1 yo Yes Yes
o
5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesive(s) !�'
jLastobond TU HT ICP Adhesives"Polyset AH-160"(FL6332);Dow Chemical"TileBond—Roof Tile Adhesive"(FL717)
Colphene FR GR ICP Adhesives"Polyset AH-160"(FL6332) J
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck: 1
I'
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TO HT, Lastobond Eaves Protection Sheet, Lastobond. 95, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern4Yellow Pine; ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
i Colphene FR GR applied to:
9 �
v Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. i;
Note:
'r
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is�eot slated for installation within
24 hours.
> Soprema requires tongue-and-groove board decking be covered With plywood or OSB prior to
installation of the self-adhering underlayment.
i.
5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR
applied to:
> Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. '
j For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems (Lastobond TU HT only),insulation attachment:shall be designed by a qualified
a design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J. i
I
1 -
I ,
i II
, Y
Exterior Research and Design,LLC. Evaluation Report 518010.06.09-1110
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-R12
Soprema,Inc. i; Revision 10:06/12/2017
'i
�, Page 4 of 7
N'Iff Ela
5.6.3 Bond to Mechanicallv Attached Base Layer:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave&Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
i ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. :l !
For installations under mechanically attached prepared roof coverings, base layer shall be attached.per
minimum codified requirements. For installations under foam-on''the systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12j,"
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications!' FRSA%TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where
the underlayment forms part of the load-path. The following wind ii plift linitations apply to underlayment
i systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications.
j Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margW,of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind
pressures.
5.6.4.1 Maximum Design Pressure=-45.0.psf:
Deck: Min. 15/32-inch plywood to meet project requiremeriks to sl tisfaction of Authority .
Having Jurisdiction. i
Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
I s' it
5.6.4.2 Maximum Design Pressure=-67.5 psf: II
Deck: Structural concrete to meet project requirements to satisfaction Of Authority Having
Jurisdiction.
Primer: Elastocol 600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
i
5.6.4.3 Maximum Design Pressure=-150.0 psf: j I
Deck: Min. 15/32-inch APA-rated BCX plywood (may ibe installed C-side up) to meet project
requirements to satisfaction of Authority Having�1Jurisdicton. fl
Deck Preparation: Plywood shall be thoroughly cleaned to remlove dust;,and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with!I the surface. All sharp
l
splinters and wood projections shall be removed/sanded:. I
,.,, I'
Primer: (Optional)RESISTO EXTERIOR PRIMER
G Underlayment: Lastobond TU HT, self-adhered, shall be tho'roughly,jroll using hand roller and/or
weighted roller to ensure there are no voids, and ensurilE'thereyare no voids/bridging at
'
side and end-laps.
5.6.4.4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requiremen'Its to satisfaction of Authority
Having Jurisdiction. I
I
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and;6-inch o.c. in three (3),
equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
I,
Exterior Research and Design,I.I.C. "Evaluation Report S18010.06.09-1110
Certificate of Authorization#950.3 FBC NON-HVHZ EVALUATION j FL2569-1112
Soprema,Inc, Revision 10:0611212017
I Page 5 of 7
I' ;I
I ,
I ,
RINI
ERD
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO
LB1236, Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-
days after installation. II +
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY!0 , Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after installation.!.' 1
1
Lastobond TU HT or Colphene FR GR shall not be left exposed for lo, ger than 180-days after installation.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail Beads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the Isubstrat&with Elastocol Stick, Elastocol
600c or RESISTO EXTERIOR PRIMER (if applicable). l
I I
6.3 Lastobond TU HT,Lastobond Shield,Lastobond Pro HT-N,RESISTO.SA SMOOTH PLY 40,Lastobond Shield
IHT, Lastobond Pro HT-S, Lastobond Eaves Protection Sheet, Lastobond i95, Lastobond Eco, Lastobond
Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&ValleV Protector,RESISTO 1.131244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970!'underlayment in FBC Sections
1507 for the.type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications: r
While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO
EXTERIOR PRIMER if the final roof cover is not slated for installation within 244 hours.
I I
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film. !"
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
�p
! Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into.place to achieve a bond.
1 Horizontal seams should be minimum 3-inches, configured to shied water. Vertical seams should be 6-
Ji
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
I
i When installing at slopes above 8:12, Soprema recommends back mailing in the overlap area at the top of
the sheet at 12-inch D.C.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
I over valley or ridge. Drape and press sheet into place, working from theICenter'of the valley or ridge in
I . each direction. For valleys,apply the sheet starting at the lowest point andwork upward.
I 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation 'Manual!and Table 1 herein, using the
instructions noted above as a guideline. i�
I
For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
1 fall outside the scope of FRSA/TRI April 2012(04-12). R
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
f underiayment.
I
• I
Exterior Research and Design,LLC. ,,Evaluation Report S18010.06.09-1110
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION i FL2569-1112
Soprema,Inc. Revision 10:06/12/2017
Page 6 of 7
I
I' i
i
it II; I
I rl
,I
I.
' TKINITYIERD
I
I
I
6.3.3.1 Lastobond TU HT has met the tile slippage test requirements specified in FRSA/TRI April 2012(04-12) up
to a 10-tile stack to a maximum roof pitch of 6:12 for flat tiles and 512 for lugged tiles. Lugged tiles staged
at pitch>5:12 may use alternate staging method (bottom 2-tile stalck shall!6e inverted,followed by 8 tiles
high on slope,as shown below). r'
21"�
- a, 4
ISG ,
I G
t
$!"5e._.-...__...s..�.-.-.._-w__..u..-.-.-......_.,..�-`_ -.�..-rti..•.�_.3.�..�.�.,_._f+..�s b�..�-a.l�i -_.-._ .I�.. _.. �' ..�.s�.r_..�_ :.!
Figure 1: Alternate Staging Met od ;, it
l Alternatively, at roof slopes greater than these limitations,all tiles shall belloaded onto a nominal 1"x 2"
1 horizontal batten to prevent slippage or damage to the underlayment I `
I N
6.3.3.2 Colphene FR GR has met the file slippage test requirements specified in FR AJTRI;April 2012(04-12)up to
a 10-tile stack to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tilers. At roof slopes greater
than these limitations,all tiles shall be loaded onto a nominal 1"x�2"horizontal batten to prevent slippage
or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to pro I'erly evaluate the installation of
this product.
8. MANUFACTURING PLANTS: i
Contact the manufacturer or the named QA entity for information on plants cc eyed under Rule 61G20-3 QA
requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
I'
-END OF EVALUATION REPORT- it
III
r. I
I I
I,
Exterior Research and Design,LLC. f i' Evaluation Report S18010.06.09-R10
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2569-R12
soprema,Inc. j Revision 10:06 /12/2017
l Page 7 of 7
I'' i�