Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 iA BQS Home ; Log In 3 User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map i Links Search a i �Product Publi Approval oval U Product Approval Menu>Product or Application Search>Application List>Application Detail i t, m � FL# FL2569-R12 I ' '- Application Type Revision Code Version 2014 Application Status Approved `, ! Comments Archived ` Is P Product Manufacturer Soprema,Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (319)478-2400 memathieu@sop rema.ca i Authorized Signature Marc-Etienne Mathieu memathieu@soprema.ca 1 Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON-US 00000 (819)478-2400 Ext33271 j memathieu@soprema.ca Quality Assurance Representative Jean-Francois Cote,Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville 4' (888)811-3145 jfcote@soprema.ca I ; I Category Roofing Subcategory Underlayments ' Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed ! Florida Professional Engineer Evaluation Report-liar py RecYeived II Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report 5 f, Florida License PE-59166 Quality Assurance Entity UL LLC j Quality Assurance Contract Expiration Date 07/17/2020 Validated By John W. Knezevich,PE V% Validation Checklist-Hardcopy Received 4, Certificate of Independence FL2569 R12 COI 2017 OS COI Nieininen.pdf Referenced Standard and Year(of Standard) Standard • Year ASTM D1970 2009 ASTM D6163 2000 I ASTM D6164 2005 FM 4474 I 2004 FRSA/TRI April 2012(04-112) 2012 TAS 103 I ? 1995 TAS 110 2000 UL 1897 2004 http://www.floridAbuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEn�cicB 10... 11/1/2017 li � ' I Florida Building Code Online Page 2 of 2 i I; Equivalence of Product Standards Certified By i Sections from the Code I ii i, II I Product Approval Method Method 1 Option D .I .i I. i! Date Submitted 06/12/2017 ! Date Validated 06/13/2017 Date Pending FBC Approval 06/15/2017 Date Approved 08/08/2017 Date Revised 10/09/2017 Summary of Products ' � I•I u FL# Model,Number or Description T Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments I Limits of Use Installation Instructions y Approved for use in HVHZ:No FL2569 R12 II 2017 06 FINAL ERI SOPREMA' CA UNDERLAYMENTS FL2569- ! Approved for use outside HVHZ:Yes R12.pdf Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party:Yes Other: 1.)Refer to ER Section 5 for Evaluation Reports j l Limits of Use.2.1 The design pressure FL2569 R12 AE 2017 06 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- noted herein pertains to underlayment R12.pdf ; ( systems used beneath adhesive-set tile Created by Independent Third Party:Yes systems.Refer to ER Section 5.6.4 for details. j Back Next � � t � I� 'I Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Pho e:850-487-1.824 I The Stale of Florida is an AA/EEO employer.Coovrlaht 2007-2013 State of Florida.::Privacy Statejment::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address releasleld in responses to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have ad,questions,!please contact 850.487.1395."Pursuant to ( Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455, :S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However'jemail addresses arepublic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made avail able to the public.To determine if you are a licensee under Giapter 455,F.S.,please click here I Product Approval Accepts: I. I9 t li Credit Card �II Safe (' t i II j ii II I �I i' I it I http://www.flon'dabuilding.org/pr/pr_app_dtl.aspx?paraln=WGEVXQwtDgsKQFEn'ckB 10... 11/1/2017 1 I ' I EXTERIOR RESEARCH&DESIGN, LLC. �I l'Certificate of Authorization#9503 ` f' 353 CHRISTIAN STREET,UNIT#13 INI � � :ERD l; OXFORD, CT 06478 (203)262-9245 EVALUATION REPORT Soprema, Inc. IEvaluat(on Report 518010.06.09-1110 1640 rue Haggerty I FL2569-R12 Drummondville,Quebec J2C 5P8 Canada Date cli Issuance:06/15/2009 (819)478-2400 ( Revision 10:06/12/2017 SCOPE: ?I This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of { construction materials in the State of Florida. The documentation submitted has,been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The` products described herein have been evaluated for compliance with the 5`h Edition (2014),Florida Building Code sections noted herein. ?' ; r DESCRIPTION: Soprema Roof Underlayments LABELING:: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named prodsct(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product;change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes, Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity ERD Evaluated" may be displayed in advertising literature. if any portion of the Evaluation Report is displayed,then it,shall be`done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request Of the Building;Official. This Evaluation Report consists of pages 1 through 7. Iii Ij Prepared by: ;€, I ,,ti?y�;,:�� • �y% Mrd I = 1 .•N. I The faaimile seal appearing vas authorized 6y Robert Nieminen,J.M. Nieminen,P.E. %�P'- +:.its = P.Lon06/12/2017.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 document.Slgnetl,sealedhircicopies have been transmitted to the rlJlJ,,,J'irr{" Prloduct Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest!in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. I III1 J 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are,J in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. I ;j it i I, i ,i I I �1,